{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T05:54:01Z","timestamp":1781589241915,"version":"3.54.5"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>This paper reports a case of accidental entry of an internal jugular vein catheter into the cervical spinal canal. A male patient in his fifties sustained injuries in a road traffic accident. During the placement of a catheter into the right internal jugular vein, the catheter inadvertently entered the cervical spinal canal, though no damage was caused to the spinal cord or nerves. A second successful puncture and catheter placement was performed under ultrasound guidance, and the patient eventually made a full recovery and was discharged. This case is extremely rare and of particular clinical significance, highlighting the importance of monitoring during the insertion and removal of catheters for internal jugular vein puncture.<\/jats:p>","DOI":"10.3389\/fmed.2026.1845016","type":"journal-article","created":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T05:37:41Z","timestamp":1781588261000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Internal jugular vein catheterization and catheter insertion slipped into the cervical spinal canal: a special case report"],"prefix":"10.3389","volume":"13","author":[{"given":"Jinshuai","family":"Zhai","sequence":"first","affiliation":[{"name":"The Department of Orthopedics, Hebei General Hospital, Shijiazhuang","place":["Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teng","family":"Huang","sequence":"additional","affiliation":[{"name":"The Department of Orthopedics, Hebei General Hospital, Shijiazhuang","place":["Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Zheng","sequence":"additional","affiliation":[{"name":"The Department of Orthopedics, Hebei General Hospital, Shijiazhuang","place":["Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Gao","sequence":"additional","affiliation":[{"name":"The Department of Orthopedics, Hebei General Hospital, Shijiazhuang","place":["Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Long","family":"Zhang","sequence":"additional","affiliation":[{"name":"The Department of Orthopedics, Hebei General Hospital, Shijiazhuang","place":["Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenyi","family":"Li","sequence":"additional","affiliation":[{"name":"The Department of Orthopedics, Hebei General Hospital, Shijiazhuang","place":["Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,6,16]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"86","DOI":"10.3969\/j.issn.1673-9701.2024.09.021","article-title":"The application of ultrasound guidance in standardised training on central venous catheterisation for anaesthesia residents.","volume":"62","author":"Zhang","year":"2024","journal-title":"China Modern Doctor."},{"key":"B2","doi-asserted-by":"publisher","first-page":"8925","DOI":"10.1038\/s41598-024-59749-2","article-title":"Impact of insertion into the left internal jugular vein in chemoport-associated infections: a retrospective single-center study of 1690 cases.","volume":"14","author":"Kim","year":"2024","journal-title":"Sci Rep"},{"key":"B3","first-page":"152","article-title":"Analysis of the clinical application value of ultrasound-guided internal jugular vein puncture and catheter insertion procedure.","volume":"6","author":"Meng","year":"2019","journal-title":"Electr J Clin Med Liter."},{"key":"B4","first-page":"505","article-title":"Comparison of the effect and complications of central venous catheterization in different sites under real-time ultrasound guidance.","volume":"36","author":"Pengfei","year":"2021","journal-title":"J N Sichuan Med Coll."},{"key":"B5","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1007\/s00134-019-05651-9","article-title":"Complications in internal jugular vs subclavian ultrasound-guided central venous catheterization: a comparative randomized trial.","volume":"45","author":"Shin","year":"2019","journal-title":"Intensive Care Med"},{"key":"B6","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1097\/ALN.0b013e31827bd172","article-title":"Real-time two-dimensional ultrasound guidance for central venous cannulation: a meta-analysis.","volume":"118","author":"Wu","year":"2013","journal-title":"Anesthesiology"},{"key":"B7","doi-asserted-by":"publisher","first-page":"955","DOI":"10.12173\/j.issn.1004-4337.202309011","article-title":"The construction and analysis of learning curve for ultrasound-guided internal jugular vein catheterization.","volume":"36","author":"Zhang","year":"2023","journal-title":"J Math Med."},{"key":"B8","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1007\/s11239-019-01877-y","article-title":"Catheter-related right internal jugular vein large thrombus formation after inadvertently malposition in the cranial direction.","volume":"48","author":"Ma","year":"2019","journal-title":"J Thromb Thrombolysis"},{"key":"B9","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s40981-023-00649-1","article-title":"Inadvertent catheter misplacement into the subclavian artery during ultrasound-guided internal jugular venous catheterization: a case report.","volume":"9","author":"Kohyama","year":"2023","journal-title":"JA Clin Rep"},{"key":"B10","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1186\/s13019-023-02194-5","article-title":"Massive hemothorax secondary to internal jugular vein central venous catheter placement in a patient undergoing spinal surgery complicated by chest trauma: a case report.","volume":"18","author":"Gong","year":"2023","journal-title":"J Cardiothorac Surg"},{"key":"B11","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1177\/1129729820910304","article-title":"Massive hemoptysis following cannulation of right internal jugular vein for insertion of cuffed hemodialysis catheter: a rare complication of central venous catheterization.","volume":"22","author":"Ghoddusi Johari","year":"2021","journal-title":"J Vasc Access"},{"key":"B12","doi-asserted-by":"publisher","first-page":"CD006962","DOI":"10.1002\/14651858.CD006962.pub2","article-title":"Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.","volume":"1","author":"Brass","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"B13","doi-asserted-by":"publisher","first-page":"3643","DOI":"10.1097\/JS9.0000000000003699","article-title":"Comparison of the success rate and complications in internal jugular vein cannulation in the first attempt between two ultrasound-guided and 22G needle-guided methods in university hospitals in Zahedan during 2023-2024.","volume":"112","author":"Khazaei","year":"2026","journal-title":"Int J Surg"},{"key":"B14","first-page":"13","article-title":"Ultrasound-guided internal jugular vein catheterization: a randomized controlled trial.","volume":"6","author":"Rando","year":"2014","journal-title":"Heart Lung Vessel."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1845016\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T05:37:46Z","timestamp":1781588266000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1845016\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,16]]},"references-count":14,"alternative-id":["10.3389\/fmed.2026.1845016"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1845016","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,16]]},"article-number":"1845016"}}