{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T06:30:42Z","timestamp":1786516242565,"version":"build-2736575974"},"reference-count":26,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Rationale<\/jats:title>\n                    <jats:p>Epidural analgesia (EA) medication errors are rare but serious adverse events in anesthesia and pain management. Previous literature has predominantly reported errors involving drug types or routes of administration, whereas those caused by infusion devices are uncommon. This case highlights the potential hazard of dose overdose resulting from an abnormal \u201cocclusion\u201d alarm when using a syringe pump for EA bolus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient concerns<\/jats:title>\n                    <jats:p>A 36-year-old male with recurrent hyperlipidemic severe acute pancreatitis, third episode, was admitted to the intensive care unit (ICU). On admission, the pain score was 7\/10 (visual analog scale, VAS). Thoracic epidural analgesia (T8-T9) was administered, with continuous infusion and intermittent boluses of a local anesthetic mixture for pain relief.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Diagnosis<\/jats:title>\n                    <jats:p>Extensive sympathetic blockade due to EA local anesthetic overdose, manifested as acute hypotension, tachycardia, and bilateral lower limb numbness after EA bolus administration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions<\/jats:title>\n                    <jats:p>Given that the patient's pain score was as high as 8\/10 on day 4, a 5 ml EA bolus of the analgesic mixture was prescribed. The nurse used a syringe pump for the bolus. Due to high catheter resistance, the pump repeatedly triggered an \u201cocclusion\u201d alarm. The nurse misinterpreted this as no drug infusion and continued the procedure after repeatedly clearing the alarm, ultimately administering approximately 10 ml. Upon recognition, the EA route was immediately closed, and rapid intravenous infusion of 500 ml of compound sodium chloride solution was administered, along with intravenous norepinephrine at 0.2 \u03bcg\/kg\/min via a syringe pump.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcomes<\/jats:title>\n                    <jats:p>Hemodynamics recovered within 10 min, and sensation in both lower limbs gradually returned to normal within 30 min. The patient was transferred to another department 5 days after the event, with no long-term sequelae.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Lessons<\/jats:title>\n                    <jats:p>Misinterpretation of a syringe pump's \u201cocclusion\u201d alarm during nurse-led epidural bolus administration can lead to local anesthetic overdose. This case underscores the need for improved training on device characteristics and alarm management.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1854450","type":"journal-article","created":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T05:55:29Z","timestamp":1786514129000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Local anesthetic overdose during nurse-led epidural analgesia due to occlusion alarm misinterpretation: a case report and literature review"],"prefix":"10.3389","volume":"13","author":[{"given":"You","family":"Yuan","sequence":"first","affiliation":[{"name":"Department of Critical Care Medicine, Affiliated Hospital of Zunyi Medical University","place":["Zunyi, Guizhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Affiliated Hospital of Zunyi Medical University","place":["Zunyi, Guizhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feiyu","family":"Yan","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Affiliated Hospital of Zunyi Medical University","place":["Zunyi, Guizhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenbo","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Affiliated Hospital of Zunyi Medical University","place":["Zunyi, Guizhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rujun","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Affiliated Hospital of Zunyi Medical University","place":["Zunyi, Guizhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,12]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1002\/ejp.1885","article-title":"The characteristics and prognostic role of acute abdominal on-admission pain in acute pancreatitis: a prospective cohort analysis of 1432 cases","volume":"26","author":"F\u00f6ldi","year":"2022","journal-title":"Eur J Pain."},{"key":"B2","doi-asserted-by":"publisher","first-page":"104754","DOI":"10.1016\/j.jpain.2024.104754","article-title":"Genetics of constant and severe pain in the naps2 cohort of recurrent acute and chronic pancreatitis patients","volume":"27","author":"Dunbar","year":"2025","journal-title":"J Pain."},{"key":"B3","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1186\/s13054-016-1292-7","article-title":"Thoracic epidural analgesia: a new approach for the treatment of acute pancreatitis?","volume":"20","author":"Windisch","year":"2016","journal-title":"Critic Care."},{"key":"B4","doi-asserted-by":"publisher","first-page":"e13740","DOI":"10.1111\/eci.13740","article-title":"Impact of early thoracic epidural analgesia in patients with severe acute pancreatitis","volume":"52","author":"Wang","year":"2022","journal-title":"Eur J Clin Invest."},{"key":"B5","doi-asserted-by":"publisher","first-page":"e198","DOI":"10.1097\/CCM.0000000000002874","article-title":"Thoracic epidural analgesia and mortality in acute pancreatitis: a multicenter propensity analysis","volume":"46","author":"Jabaudon","year":"2018","journal-title":"Crit Care Med."},{"key":"B6","doi-asserted-by":"publisher","first-page":"e0337803","DOI":"10.1371\/journal.pone.0337803","article-title":"Effectiveness and safety of nurse-led different epidural analgesia methods based on symptom management theory in patients with severe acute pancreatitis: a single-center Rct protocol","volume":"21","author":"Yuan","year":"2026","journal-title":"PLoS ONE."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.mayocp.2014.05.007","article-title":"Medication errors: an overview for clinicians","volume":"89","author":"Wittich","year":"2014","journal-title":"Mayo Clinic proceedings."},{"key":"B8","first-page":"75","article-title":"Inadvertent epidural injection of drugs for intravenous use. A review","volume":"63","author":"Beckers","year":"2012","journal-title":"Acta anaesthesiologica Belgica."},{"key":"B9","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1111\/hex.13029","article-title":"The views and experiences of patients and health-care professionals on the disclosure of adverse events: a systematic review and qualitative meta-ethnographic synthesis","volume":"23","author":"Sattar","year":"2020","journal-title":"Health Expect."},{"key":"B10","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1136\/rapm-2020-101836","article-title":"Neuraxial and peripheral misconnection events leading to wrong-route medication errors: a comprehensive literature review","volume":"46","author":"Viscusi","year":"2021","journal-title":"Reg Anesth Pain Med."},{"key":"B11","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.aat.2010.04.002","article-title":"Sudden transient paraplegia shortly after preoperative thoracic epidural catheterization\u2013a case report","volume":"48","author":"Liao","year":"2010","journal-title":"Acta anaesthesiologica Taiwanica."},{"key":"B12","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1007\/s40122-024-00701-7","article-title":"A systematic review of antibiotic administration incidents involving neuraxial routes: clinical analysis, contributing factors and prevention approaches","volume":"14","author":"Patel","year":"2025","journal-title":"Pain Ther."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1007\/s12630-022-02276-3","article-title":"Accidental administration of tranexamic acid into the epidural space: a case report","volume":"69","author":"Pysyk","year":"2022","journal-title":"Canadian J Anaesth."},{"key":"B14","doi-asserted-by":"publisher","first-page":"e65371","DOI":"10.7759\/cureus.65371","article-title":"Unintentional infusion of insulin into the epidural space during labor","volume":"16","author":"Neves","year":"2024","journal-title":"Cureus."},{"key":"B15","doi-asserted-by":"publisher","first-page":"00185787251408703","DOI":"10.1177\/00185787251408703","article-title":"Inadvertent administration of oxytocin via epidural","volume":"5","author":"Tcherepanova","year":"2026","journal-title":"Hospital Pharm."},{"key":"B16","doi-asserted-by":"publisher","first-page":"135","DOI":"10.4103\/ijabmr.IJABMR_96_19","article-title":"Medication errors: is it the hidden part of the submerged iceberg in our health-care system?","volume":"9","author":"Ambwani","year":"2019","journal-title":"Int J Appl Basic Med Res."},{"key":"B17","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1016\/j.pharma.2024.02.015","article-title":"Strategy to secure the neuraxial route in anaesthesia: risk mapping and feedback from the application of the Iso 80369-6 standard Nrfit\u00ae connectors","volume":"82","author":"Amiot","year":"2024","journal-title":"Ann Pharm Fr."},{"key":"B18","doi-asserted-by":"publisher","first-page":"249","DOI":"10.4103\/sja.SJA_218_19","article-title":"Cardiac arrhythmia from epinephrine overdose in epidural test dose","volume":"13","author":"Borden","year":"2019","journal-title":"Saudi J Anaesth."},{"key":"B19","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1186\/s12912-025-03084-y","article-title":"Exploring icu nurses' response to alarm management and strategies for alleviating alarm fatigue: a meta-synthesis and systematic review","volume":"24","author":"Xu","year":"2025","journal-title":"BMC Nurs."},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.1136\/ejhpharm-2025-004533","article-title":"Tackling medication errors: how a systems approach improves patient safety","author":"Guntschnig","year":"2025","journal-title":"Eur J Hospital Pharm."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1566335","DOI":"10.3389\/frhs.2025.1566335","article-title":"Hospital managers' experiences of conducting a root cause analysis: a case study following a sentinel event","volume":"5","author":"Liepelt","year":"2025","journal-title":"Front Health Serv."},{"key":"B22","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.hrtlng.2025.09.013","article-title":"Exploring intensive care unit nurses' decision-making in alarm management: a qualitative study","volume":"75","author":"Haskell","year":"2026","journal-title":"Heart Lung."},{"key":"B23","doi-asserted-by":"publisher","first-page":"230","DOI":"10.4037\/aacnacc2025998","article-title":"Optimizing patient safety: intravenous smart pump usability in acute and critical care","volume":"36","author":"Giuliano","year":"2025","journal-title":"AACN Adv Crit Care."},{"key":"B24","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.cnc.2018.02.004","article-title":"Intravenous smart pumps: usability issues, intravenous medication administration error, and patient safety","volume":"30","author":"Giuliano","year":"2018","journal-title":"Crit Care Nurs Clin North Am."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.3390\/nursrep14030117","article-title":"Predisposing factors to medication errors by nurses and prevention strategies: a scoping review of recent literature","volume":"14","author":"Coelho","year":"2024","journal-title":"Nursing reports."},{"key":"B26","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1016\/j.sapharm.2019.12.005","article-title":"Interventions to improve reporting of medication errors in hospitals: a systematic review and narrative synthesis","volume":"16","author":"Gleeson","year":"2020","journal-title":"Res Social Adm Pharm."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1854450\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T05:55:30Z","timestamp":1786514130000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1854450\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,12]]},"references-count":26,"alternative-id":["10.3389\/fmed.2026.1854450"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1854450","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,12]]},"article-number":"1854450"}}