{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T12:01:09Z","timestamp":1785326469024,"version":"3.55.0"},"reference-count":23,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To comparatively analyze visual quality after cataract surgery with implantation of the extended depth of focus (EDOF) refractive-diffractive hybrid bifocal intraocular lens (IOL) AM3UH and the refractive-diffractive hybrid trifocal intraocular lens AT LISA tri 839MP.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This was a multicenter, retrospective and prospective bidirectional cohort study. Sixty-nine patients (69 eyes) with AM3UH IOL implantation were enrolled in the AM3UH group. Sixty-two patients (62 eyes) implanted with AT LISA tri 839MP IOL were enrolled in the 839MP group. Uncorrected distance visual acuity (UDVA, logMAR), uncorrected intermediate visual acuity (UIVA, logMAR), uncorrected near visual acuity (UNVA, logMAR) and best corrected distance visual acuity (BCDVA) were assessed before and 3 months after surgery. The visual function index 11R (VF-11R) was used to evaluate the quality of life after cataract surgery. Light interference, spectacle independence and postoperative satisfaction were evaluated by questionnaires.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The preoperative UDVA of AM3UH group and 839MP group was (0.93 \u00b1 0.38) logMAR and (0.90 \u00b1 0.47) logMAR, respectively. At 3 months postoperatively, the UDVA, UIVA, UNVA and BCDVA of the AM3UH group were (0.14 \u00b1 0.19) logMAR, (0.13 \u00b1 0.12) logMAR, (0.15 \u00b1 0.1) logMAR, and (0.09 \u00b1 0.11) logMAR, respectively; and those of the 839MP group were (0.90 \u00b1 0.47) logMAR, (0.12 \u00b1 0.08) logMAR, (0.07 \u00b1 0.08) logMAR, (0.12 \u00b1 0.06) logMAR, and (0.05 \u00b1 0.04) logMAR, respectively. Both IOLs (AM3UH and 839MP) significantly improved postoperative UDVA. No significant differences were observed between groups regarding distance, near, or best-corrected distance visual acuity (\n                      <jats:italic>P<\/jats:italic>\n                      &amp;gt; 0.05); however, the trifocal 839MP group demonstrated significantly superior UIVA. Patient satisfaction with intermediate and near vision was also higher in the 839MP group, though far vision satisfaction was similar. Both lenses showed low and comparable levels of glare and halos (the majority of patients were either asymptomatic or reported only mild symptoms), with a slight trend toward less glare and more halos in the 839MP group. Rates of spectacle independence at all distances did not differ significantly (\n                      <jats:italic>P<\/jats:italic>\n                      &amp;gt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Both lenses offer good visual quality and increased spectacle independence. The AT LISA tri 839MP provides superior intermediate vision and related patient satisfaction, with a similar overall side-effect profile.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1872773","type":"journal-article","created":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T11:10:52Z","timestamp":1785323452000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of visual quality between the refractive-diffractive hybrid bifocal EDOF and the refractive-diffractive hybrid trifocal IOL"],"prefix":"10.3389","volume":"13","author":[{"given":"Yanfeng","family":"Zeng","sequence":"first","affiliation":[{"name":"Cataract Department, Lixiang Eye Hospital of Soochow University","place":["Suzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiyao","family":"Ma","sequence":"additional","affiliation":[{"name":"Cataract Department, Lixiang Eye Hospital of Soochow University","place":["Suzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuancheng","family":"Qu","sequence":"additional","affiliation":[{"name":"School of Medicine, Shanghai University of Medicine and Health Sciences","place":["Shanghai, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lie","family":"Ma","sequence":"additional","affiliation":[{"name":"Cataract Department, Lixiang Eye Hospital of Soochow University","place":["Suzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jipu","family":"Bu","sequence":"additional","affiliation":[{"name":"Cataract Department, ChangSha BoShi Eye Hospital","place":["ChangSha, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoli","family":"Zhou","sequence":"additional","affiliation":[{"name":"Cataract Department, Lixiang Eye Hospital of Soochow University","place":["Suzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Sheng","sequence":"additional","affiliation":[{"name":"Cataract Department, Lixiang Eye Hospital of Soochow University","place":["Suzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiping","family":"Yin","sequence":"additional","affiliation":[{"name":"Cataract Department, Lixiang Eye Hospital of Soochow University","place":["Suzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,29]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1097\/apo.0000000000000590","article-title":"Latest development in extended depth-of-focus intraocular lenses: an update.","volume":"12","author":"Barnir","year":"2023","journal-title":"Asia Pac J Ophthalmol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1709","DOI":"10.1007\/s10792-017-0652-x","article-title":"Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.","volume":"38","author":"Pedrotti","year":"2017","journal-title":"Int Ophthalmol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1285947","DOI":"10.1155\/2021\/1285947","article-title":"Intraoperative and postoperative intraocular lens opacifications: analysis of 42545 cases.","volume":"2021","author":"Wang","year":"2021","journal-title":"JOphthalmol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"2867","DOI":"10.4103\/ijo.IJO_2921_21","article-title":"Comparison of clinical outcomes of trifocal intraocular lens (AT LISA, Eyecryl SERT trifocal) versus extended depth of focus intraocular lens (Eyhance, Eyecryl SERT EDOF).","volume":"70","author":"Karuppiah","year":"2022","journal-title":"Indian J Ophthalmol."},{"key":"B5","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/j.jcrs.2017.03.037","article-title":"Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: trifocal versus extended range of vision.","volume":"43","author":"Monaco","year":"2017","journal-title":"J Cataract Refract Surg."},{"key":"B6","doi-asserted-by":"publisher","first-page":"2449.e","DOI":"10.1016\/j.ophtha.2013.07.048","article-title":"Randomized trial of multifocalintraocular lenses versus monovision after bilateral cataract surgery.","volume":"120","author":"Wilkins","year":"2013","journal-title":"Ophthalmology."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1016\/j.jcrs.2019.06.005","article-title":"Visual and refractive outcomes, spectacle independence, and visual disturbances after cataract or refractive lens exchange surgery: comparison of 2 trifocal intraocular lenses.","volume":"45","author":"Asena","year":"2019","journal-title":"J Cataract Refract Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1709","DOI":"10.1007\/s10792-017-0652-x","article-title":"Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.","volume":"38","author":"Pedrotti","year":"2018","journal-title":"Int Ophthalmol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1001\/archopht.1994.01090170074026","article-title":"The VF-14. an index of functional impairment in patients with cataract.","volume":"112","author":"Steinberg","year":"1994","journal-title":"Arch Ophthalmol."},{"key":"B10","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/j.jcrs.2017.03.037","article-title":"Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: trifocal versus extended range of vision.","volume":"43","author":"Monaco","year":"2017","journal-title":"J Cataract Refract Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1055\/a-1111-9380","article-title":"[Current review: multifocal intraocular lenses and extended depth of focus intraocular lenses].","volume":"237","author":"Breyer","year":"2020","journal-title":"Klin Monbl Fur Augenheil K."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.jcrs.2013.01.048","article-title":"Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench.","volume":"39","author":"Gatinel","year":"2013","journal-title":"J Cataract Refract Surg."},{"key":"B13","doi-asserted-by":"publisher","first-page":"8386","DOI":"10.1038\/s41598-024-58653-z","article-title":"Visual outcomes and patient satisfaction after implantations of three types of presbyopia-correcting intraocular lenses that have undergone corneal refractive surgery.","volume":"14","author":"Ni","year":"2024","journal-title":"Sci Rep."},{"key":"B14","first-page":"245","article-title":"1-year follow-up study on visual quality after implantation of trifocal versus bifocal intraocular lenses.","volume":"44","author":"Bian","year":"2024","journal-title":"J Nantong Univ."},{"key":"B15","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.jcrs.2015.06.040","article-title":"In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens","volume":"42","author":"Vicent","year":"2016","journal-title":"J Cataract Refract Surg."},{"key":"B16","doi-asserted-by":"publisher","first-page":"228","DOI":"10.3928\/1081597X-20180125-01","article-title":"Visual performance of a new extended depth-of-focus intraocular lens compared to a distance-dominant diffractive multifocal intraocular lens.","volume":"34","author":"Savini","year":"2018","journal-title":"J Refract Surg."},{"key":"B17","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/j.jcrs.2017.03.037","article-title":"Comparison of the intermediate distance of a trifocal IOL with an extended depth-of-focus IOL: results of a prospective randomized trial.","volume":"43","author":"Webers","year":"2017","journal-title":"J Cataract Refract Surg."},{"key":"B18","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1016\/j.jcrs.2006.02.006","article-title":"History and development of the apodized diffractive intraocular lens.","volume":"32","author":"Davison","year":"2006","journal-title":"J Cataract Refract Surg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"CD014891","DOI":"10.1002\/14651858.CD014891.pub2","article-title":"Trifocal versus extended depth of focus (EDOF) intraocular lenses after cataract extraction.","volume":"7","author":"Tavassoli","year":"2024","journal-title":"Cochrane Database Syst Rev."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.jcrs.2007.02.037","article-title":"Functional outcomes after implantation of Tecnis ZM900 and Array SA40 multifocal intraocular lenses.","volume":"33","author":"Mester","year":"2007","journal-title":"J Cataract Refrac Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/j.jcrs.2008.10.043","article-title":"Visual performance and contrast sensitivity after phacoemulsification with implantation of aspheric foldable intraocular lenses.","volume":"35","author":"Nabh","year":"2009","journal-title":"J Cataract Refrac Surg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"4413","DOI":"10.1167\/iovs.14-14017","article-title":"Translation cultural adaptation, and rasch analysis of the visual function (VF-14) questionnaire.","volume":"55","author":"Khadka","year":"2014","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"B23","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.ebiom.2018.03.002","article-title":"Visual restoration after cataract surgery promotes functional and structural brain recovery.","volume":"30","author":"Lin","year":"2018","journal-title":"E Bio Medi."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1872773\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T11:10:53Z","timestamp":1785323453000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1872773\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,29]]},"references-count":23,"alternative-id":["10.3389\/fmed.2026.1872773"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1872773","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,29]]},"article-number":"1872773"}}