{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T11:45:17Z","timestamp":1782992717361,"version":"3.54.5"},"reference-count":16,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Analytical consistency in complete blood count (CBC) testing is essential when introducing new hematology analyzers into routine clinical use. This study evaluated the agreement between the Atellica HEMA 580 and the Sysmex XN-1000 using a standardized method-comparison approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 100 residual K\u2082EDTA whole-blood samples were analyzed on both systems between April and June 2025. Method comparison followed CLSI EP09c guidelines, including Passing\u2013Bablok regression, Spearman correlation, bias estimation at predefined medical-decision levels, and Bland\u2013Altman analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Strong analytical agreement was observed for most parameters, with correlation coefficients exceeding 0.98 for key indices including RBC (\n                      <jats:italic>r<\/jats:italic>\n                      \u202f=\u202f0.999), HGB (\n                      <jats:italic>r<\/jats:italic>\n                      \u202f=\u202f0.998), WBC (\n                      <jats:italic>r<\/jats:italic>\n                      \u202f=\u202f0.996), and PLT-I (\n                      <jats:italic>r<\/jats:italic>\n                      \u202f=\u202f0.995), and regression slopes close to unity. Bias estimates at medical-decision levels were within allowable limits for the majority of parameters. WBC at 0.5\u202f\u00d7\u202f10\n                      <jats:sup>9<\/jats:sup>\n                      \/L and PLT-I at 100\u202f\u00d7\u202f10\n                      <jats:sup>9<\/jats:sup>\n                      \/L achieved Outcome A, indicating optimal agreement at clinically critical thresholds. In contrast, MCV showed proportional deviation with bias exceeding allowable limits at both 80\u202ffL and 100\u202ffL, and RDW-CV demonstrated lower correlation (\n                      <jats:italic>r<\/jats:italic>\n                      \u202f=\u202f0.848) and greater dispersion. Bland\u2013Altman analysis confirmed small mean bias for most parameters, with narrow limits of agreement for RBC (\u22121.48%, LoA\u202f\u2212\u202f4.19 to 1.36) and HGB (1.54%, LoA\u202f\u2212\u202f1.37 to 4.19), while wider limits were observed for WBC (\u221212.62 to 1.70) and PLT-I (\u221216.55 to 9.51). RDW-CV exhibited the broadest limits of agreement (\u221217.76 to 10.38). Among differential parameters, lymphocyte count showed optimal agreement (bias \u22121.12%, Outcome A), while other indices remained within acceptable ranges.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The Atellica HEMA 580 shows acceptable analytical agreement with the Sysmex XN-1000 for RBC, HGB, WBC, PLT-I, and the evaluated neutrophil and lymphocyte differential parameters, and can be applied in clinical laboratory practice. In contrast, MCV and RDW-CV demonstrated analyzer-dependent differences that warrant cautious interpretation when comparing results across platforms or during longitudinal assessment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1878534","type":"journal-article","created":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T11:10:13Z","timestamp":1782990613000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Analytical agreement and clinical interchangeability of routine complete blood count parameters between the Atellica HEMA 580 and Sysmex XN-1000 analyzers: a CLSI EP09c study"],"prefix":"10.3389","volume":"13","author":[{"given":"Quang Tung","family":"Nguyen","sequence":"first","affiliation":[{"name":"Department of Hematology, Hanoi Medical University","place":["Hanoi, Vietnam"]},{"name":"Department of Hematology and Transfusion Medicine, Hanoi Medical University Hospital","place":["Hanoi, Vietnam"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Van Tuan","family":"Pham","sequence":"additional","affiliation":[{"name":"Department of Hematology and Transfusion Medicine, Hanoi Medical University Hospital","place":["Hanoi, Vietnam"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chi Thanh","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Department of Hematology and Transfusion Medicine, Hanoi Medical University Hospital","place":["Hanoi, Vietnam"]},{"name":"Department of Hematology Laboratory, Hanoi Medical University","place":["Hanoi, Vietnam"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phuc Minh Hoang","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Department of Hematology and Transfusion Medicine, Hanoi Medical University Hospital","place":["Hanoi, Vietnam"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dieu Huong","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Department of Hematology and Transfusion Medicine, Hanoi Medical University Hospital","place":["Hanoi, Vietnam"]},{"name":"Department of Hematology Laboratory, Hanoi Medical University","place":["Hanoi, Vietnam"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huong Lan","family":"Tong","sequence":"additional","affiliation":[{"name":"Department of Hematology and Transfusion Medicine, Hanoi Medical University Hospital","place":["Hanoi, Vietnam"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,2]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1111\/ijlh.12201","article-title":"ICSH guidelines for the evaluation of blood cell analyzers including those used for differential leucocyte and reticulocyte counting","volume":"36","author":"Briggs","year":"2014","journal-title":"Int J Lab Hematol"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1111\/ijlh.12254","article-title":"Performance evaluation of the new hematology analyzer Sysmex XN-series","volume":"37","author":"Seo","year":"2015","journal-title":"Int J Lab Hematol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1136\/jclinpath-2014-202223","article-title":"Immature granulocyte count in peripheral blood by the Sysmex XN hematology series compared with microscopic differentiation","volume":"67","author":"Maenhout","year":"2014","journal-title":"J Clin Pathol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1111\/ijlh.14170","article-title":"Performance evaluation of the new automated Atellica HEMA 580 hematology analyzer","volume":"46","author":"Schapkaitz","year":"2024","journal-title":"Int J Lab Hematol"},{"key":"ref5","volume-title":"Validation, Verification, and Quality Assurance of Automated Hematology Analyzers; Approved Guideline-Second Edition (H26-A2)","year":"2010"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1111\/ijlh.12503","article-title":"Verification and quality control of routine hematology analyzers","volume":"38","author":"Vis","year":"2016","journal-title":"Int J Lab Hematol"},{"key":"ref7","volume-title":"Measurement Procedure Comparison and Bias Estimation Using Patient Samples (EP09c)","year":"2018"},{"key":"ref8","first-page":"15.21","volume-title":"Automated Hematology Analyzer XN Series (XN-1000): Instruction for Use","year":"2017"},{"key":"ref9","volume-title":"XN-Series White Paper: Fluorescence Flow Cytometry and Hydrodynamic Focusing Technology","year":"2020"},{"key":"ref10","volume-title":"Atellica HEMA 580 Analyzer Operator\u2019s Guide","year":"2024"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation coefficients: appropriate use and interpretation","volume":"126","author":"Schober","year":"2018","journal-title":"Anesth Analg"},{"key":"ref12","year":""},{"key":"ref13","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.clinbiochem.2018.01.014","article-title":"Performance evaluation of the new measurement channels on the automated Sysmex XN-9000 hematology analyzer","volume":"53","author":"Schapkaitz","year":"2018","journal-title":"Clin Biochem"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1111\/ijlh.14149","article-title":"Comparison of Atellica HEMA 580 and Beckman coulter DxH 800 hematology analyzers","volume":"45","author":"Bello-Rego","year":"2023","journal-title":"Int J Lab Hematol"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"A289","DOI":"10.21276\/apalm.2411","article-title":"A study of storage related changes and effect of refrigeration on hematological parameters and blood cell morphology in EDTA anticoagulated blood","volume":"6","author":"Basu","year":"2019","journal-title":"Ann Pathol Lab Med"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"625","DOI":"10.18231\/j.ijpo.2020.123","article-title":"Effect of room temperature and refrigerated storage on automated hematological parameters","volume":"7","author":"Sree Ramya","year":"2020","journal-title":"Indian J Pathol Oncol"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1878534\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T11:10:15Z","timestamp":1782990615000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1878534\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,2]]},"references-count":16,"alternative-id":["10.3389\/fmed.2026.1878534"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1878534","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,2]]},"article-number":"1878534"}}