{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T06:06:04Z","timestamp":1784786764366,"version":"3.55.0"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T00:00:00Z","timestamp":1784764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Radial artery catheterization can be challenging in elderly patients. The clinical value of integrated system combining a wireless ultrasound probe and smart glasses remains unclear. This study evaluated whether this approach improves first puncture success compared with conventional ultrasound guidance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>This prospective randomized controlled trial enrolled 194 patients aged \u226565\u202fyears with American Society of Anesthesiologists physical status I\u2013III who were scheduled for elective surgery requiring radial artery catheterization. Patients were randomly assigned to the smart glasses group or conventional ultrasound group in a 1:1 ratio. The primary outcome was the first puncture success rate. Secondary outcomes included procedure-related behavioral indicators of hand\u2013eye coordination, procedure time, and operator satisfaction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 194 patients were analyzed. The first puncture success rate was significantly higher in the smart glasses group than in the ultrasound group [88\/97, 90.72% vs. 66\/97, 68.04%;\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001; relative risk (RR)\u202f=\u202f1.333; 95% confidence interval (CI), 1.147\u20131.550]. Compared with the ultrasound group, the smart glasses group showed fewer head rotations [0 (0, 0) vs. 2 (1, 3);\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001], ultrasound probe repositionings [0 (0, 1) vs. 1 (0, 2);\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001], and needle redirections [2 (0, 2) vs. 2 (1, 3);\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001]. Operator satisfaction, measured using a visual analog scale (VAS), was higher in the smart glasses group than in the ultrasound group [86 (79\u201390) vs. 70 (60\u201379); median difference, 13.00; 95% CI, 10.00\u201317.00;\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.001].\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Compared with conventional ultrasound guidance, integrated wireless ultrasound and smart glasses system improved the first puncture success rate of radial artery catheterization in elderly patients and enhanced procedure-related behavioral indicators associated with hand\u2013eye coordination, including head rotations, ultrasound probe repositioning, and needle angle adjustments. This approach also shortened procedure time and improved operator satisfaction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1884099","type":"journal-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T05:39:01Z","timestamp":1784785141000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Smart glasses integrated with a wireless ultrasound system for radial artery catheterization in elderly patients: a randomized controlled trial"],"prefix":"10.3389","volume":"13","author":[{"given":"Wudong","family":"Zhuang","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Hebei Province Key Laboratory of Integrated Traditional and Western Medicine in Neurological Rehabilitation, Hebei Key Laboratory of Integrated Traditional and Western Medicine in Osteoarthrosis Research (Preparing)","place":["Cangzhou, Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruizhao","family":"Lyu","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Hebei Province Key Laboratory of Integrated Traditional and Western Medicine in Neurological Rehabilitation, Hebei Key Laboratory of Integrated Traditional and Western Medicine in Osteoarthrosis Research (Preparing)","place":["Cangzhou, Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyuan","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Hebei Province Key Laboratory of Integrated Traditional and Western Medicine in Neurological Rehabilitation, Hebei Key Laboratory of Integrated Traditional and Western Medicine in Osteoarthrosis Research (Preparing)","place":["Cangzhou, Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Hebei Province Key Laboratory of Integrated Traditional and Western Medicine in Neurological Rehabilitation, Hebei Key Laboratory of Integrated Traditional and Western Medicine in Osteoarthrosis Research (Preparing)","place":["Cangzhou, Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Hebei Province Key Laboratory of Integrated Traditional and Western Medicine in Neurological Rehabilitation, Hebei Key Laboratory of Integrated Traditional and Western Medicine in Osteoarthrosis Research (Preparing)","place":["Cangzhou, Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianhua","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Hebei Province Key Laboratory of Integrated Traditional and Western Medicine in Neurological Rehabilitation, Hebei Key Laboratory of Integrated Traditional and Western Medicine in Osteoarthrosis Research (Preparing)","place":["Cangzhou, Hebei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1197\/j.aem.2006.07.015","article-title":"A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters","volume":"13","author":"Shiver","year":"2006","journal-title":"Acad Emerg Med"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1016\/j.ajem.2013.01.029","article-title":"Ultrasound guidance for radial arterial puncture: a randomized controlled trial","volume":"31","author":"Bobbia","year":"2013","journal-title":"Am J Emerg Med"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1097\/EJA.0000000000001180","article-title":"European Society of Anaesthesiology guidelines on peri-operative use of ultrasound-guided for vascular access (PERSEUS vascular access)","volume":"37","author":"Lamperti","year":"2020","journal-title":"Eur J Anaesthesiol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1093\/bja\/aew097","article-title":"Ultrasound-guided radial artery cannulation in adult and paediatric populations: a systematic review and meta-analysis","volume":"116","author":"White","year":"2016","journal-title":"Br J Anaesth"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"2495","DOI":"10.1002\/jum.14291","article-title":"Ultrasound versus traditional palpation to guide radial artery cannulation in critically ill children: a randomized trial","volume":"36","author":"Anantasit","year":"2017","journal-title":"J Ultrasound Med"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"e0251712","DOI":"10.1371\/journal.pone.0251712","article-title":"Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: a prospective randomized controlled study","volume":"16","author":"Kim","year":"2021","journal-title":"PLoS One"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jclinane.2018.03.019","article-title":"Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: an updated meta-analysis of randomized controlled trials","volume":"47","author":"Bhattacharjee","year":"2018","journal-title":"J Clin Anesth"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.ajem.2014.10.008","article-title":"Effects of ultrasound-guided radial artery catheterization: an updated meta-analysis","volume":"33","author":"Gao","year":"2015","journal-title":"Am J Emerg Med"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1378\/chest.10-0919","article-title":"Ultrasound-guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trials","volume":"139","author":"Shiloh","year":"2011","journal-title":"Chest"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1378\/chest.15-1784","article-title":"Ultrasound guidance facilitates radial artery catheterization: a Meta-analysis with trial sequential analysis of randomized controlled trials","volume":"149","author":"Gu","year":"2016","journal-title":"Chest"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1755","DOI":"10.1111\/echo.14451","article-title":"Point-of-care ultrasound with pocket-size devices in emergency department","volume":"36","author":"Mancusi","year":"2019","journal-title":"Echocardiography"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1186\/s12871-024-02828-8","article-title":"The effect of smart glasses combined with ultrasound on radial arterial catheterization: a randomized controlled trial","volume":"24","author":"Wang","year":"2024","journal-title":"BMC Anesthesiol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"350","DOI":"10.4274\/TJAR.2025.252052","article-title":"The effect of using smart glasses integrated ultrasonography in radial artery catheterization: a prospective randomized trial","volume":"53","author":"G\u00f6zen","year":"2025","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1097\/ALN.0000000000003914","article-title":"Smart glasses for radial arterial catheterization in pediatric patients: a randomized clinical trial","volume":"135","author":"Jang","year":"2021","journal-title":"Anesthesiology"},{"key":"ref15","first-page":"83","article-title":"Ultrasound-guided regional anesthesia using a head-mounted video display: a randomized clinical study","volume":"24","author":"Przkora","year":"2021","journal-title":"Pain Physician"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"356","DOI":"10.15441\/ceem.19.029","article-title":"Use of smart glasses for ultrasound-guided peripheral venous access: a randomized controlled pilot study","volume":"6","author":"Lim","year":"2019","journal-title":"Clin Exp Emerg Med"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"2201","DOI":"10.2147\/JMDH.S424487","article-title":"Smart glasses to facilitate ultrasound guided peripheral intravenous access in the simulation setting for Thai emergency medical service providers","volume":"16","author":"Ienghong","year":"2023","journal-title":"J Multidiscip Healthc"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1097\/EJA.0000000000001985","article-title":"Effectiveness of head-mounted ultrasound display for radial arterial catheterisation in paediatric patients by anaesthesiology trainees","volume":"41","author":"Kim","year":"2024","journal-title":"Eur J Anaesthesiol"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"1635","DOI":"10.1007\/s12630-023-02532-0","article-title":"Laser guidance for ultrasound-guided radial artery catheterization using smart glasses: a randomized trial","volume":"70","author":"Kim","year":"2023","journal-title":"Can J Anaesth"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1097\/SIH.0000000000000636","article-title":"Virtual reality head-mounted displays in medical education","volume":"18","author":"Turs\u00f8-Finnich","year":"2023","journal-title":"Simul Healthc"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1016\/j.jemermed.2014.07.045","article-title":"Ultrasound-guided central venous access using Google glass","volume":"47","author":"Wu","year":"2014","journal-title":"J Emerg Med"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"E321","DOI":"10.1055\/s-0032-1312824","article-title":"Dynamic needle tip positioning - ultrasound guidance for peripheral vascular access. A randomized, controlled and blinded study in phantoms performed by ultrasound novices","volume":"33","author":"Clemmesen","year":"2012","journal-title":"Ultraschall Med"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1053\/j.jvca.2012.07.007","article-title":"Ultrasound-guided vascular access: a comprehensive review","volume":"27","author":"Weiner","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1097\/ALN.0000000000003308","article-title":"Subcutaneous nitroglycerin for radial arterial catheterization in pediatric patients: a randomized controlled trial","volume":"133","author":"Jang","year":"2020","journal-title":"Anesthesiology"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"101096","DOI":"10.1016\/j.accpm.2022.101096","article-title":"Preventing radial arterial catheter failure in critical care \u2014 factoring updated clinical strategies and techniques","volume":"41","author":"Imbr\u00ecaco","year":"2022","journal-title":"Anaesth Crit Care Pain Med"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1186\/s12909-022-03345-3","article-title":"The application of the acoustic shadowing facilitates guidance in radial artery puncture and cannulation teaching in standardized training for residents: a randomized controlled trial","volume":"22","author":"Dong","year":"2022","journal-title":"BMC Med Educ"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1186\/s12889-024-17757-x","article-title":"Work-related musculoskeletal complaints and ergonomic risk factors among Egyptian anesthesiologists: a cross-sectional study","volume":"24","author":"Fouad","year":"2024","journal-title":"BMC Public Health"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"515","DOI":"10.3390\/s24206515","article-title":"Effects of smart glasses on the visual acuity and eye strain of employees in logistics and picking: a six-month observational study","volume":"24","author":"Herold","year":"2024","journal-title":"Sensors (Basel)"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1884099\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T05:39:02Z","timestamp":1784785142000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1884099\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,23]]},"references-count":28,"alternative-id":["10.3389\/fmed.2026.1884099"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1884099","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,23]]},"article-number":"1884099"}}