{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T11:58:58Z","timestamp":1785239938744,"version":"3.55.0"},"reference-count":45,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T00:00:00Z","timestamp":1785196800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The early detection of idiopathic corneal endothelial compromise, a common yet underdiagnosed pre-cataract finding, remains a challenge. This study aimed to investigate the association between corneal biomechanical parameters and endothelial status, identify potential biomechanical markers, and explore the biomechanical manifestations of idiopathic endothelial impairment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this cross-sectional study, cataract patients with normal endothelium or idiopathic endothelial abnormality underwent Corneal Visualization Scheimpflug Technology (Corvis ST) tonometry and specular microscopy. Beyond conventional statistics, we employed stability selection\u2014a machine learning method with explicit error control\u2014to identify the most reproducible predictors from a multitude of biomechanical parameters, while rigorously accounting for central corneal thickness (CCT) via stratified analysis and propensity score matching (PSM).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Among 241 patients (35 with endothelial abnormality), five biomechanical parameters (SSI, HCR, A2L, A1T, cTBI) significantly differed between groups, even after PSM for CCT. Stratified analysis revealed the strongest biomechanical-endothelial correlations specifically within the mid-range CCT (530\u2013570\u202f\u03bcm). A2L was identified as an independent protective factor (OR: 0.202, 95%CI: 0.051\u20130.731,\n                      <jats:italic>p<\/jats:italic>\n                      \u202f=\u202f0.018). Stability selection confirmed A2L and cTBI as the most robust markers. A novel DASC model (incorporating A2L, DA, SSI, and CCT) achieved an AUC of 0.711 for detecting endothelial abnormalities, comparable to the cTBI score (AUC: 0.683, 95%CI: 0.565\u20130.800).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Corneal biomechanics reflect early endothelial alterations. A2L, cTBI, and the DASC model serve as promising, noninvasive tools for risk stratification. Our findings suggest that subclinical endothelial impairment manifests as reduced corneal stiffness-related response and impaired deformation behavior.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1899851","type":"journal-article","created":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T11:10:19Z","timestamp":1785237019000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Stability selection machine learning identifies biomechanical markers for subclinical idiopathic corneal endothelial abnormalities"],"prefix":"10.3389","volume":"13","author":[{"given":"Chengjie","family":"Feng","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miaomiao","family":"Chi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shaofeng","family":"Gu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,28]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1755","DOI":"10.1167\/iovs.05-1139","article-title":"The balance between corneal transparency and edema the proctor lecture","volume":"47","author":"Edelhauser","year":"2006","journal-title":"Investig Opthalmology Vis Sci"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1113\/jphysiol.1972.sp009737","article-title":"The location of the fluid pump in the cornea","volume":"221","author":"Maurice","year":"1972","journal-title":"J Physiol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1097\/j.jcrs.0000000000000650","article-title":"The corneal endothelium: clinical review of endothelial cell health and function","volume":"47","author":"Gupta","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"6951","DOI":"10.1038\/s41598-017-07534-9","article-title":"Acute ocular hypertension disrupts barrier integrity and pump function in rat corneal endothelial cells","volume":"7","author":"Li","year":"2017","journal-title":"Sci Rep"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"108068","DOI":"10.1016\/j.exer.2020.108068","article-title":"12. Endothelial pump and barrier function","volume":"198","author":"Klyce","year":"2020","journal-title":"Exp Eye Res"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"365","DOI":"10.3109\/02713688908996384","article-title":"A correlative electron microscopic and freeze-fracture examination of cat corneal endothelial wound repair","volume":"8","author":"Tuberville","year":"1989","journal-title":"Curr Eye Res"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1574","DOI":"10.1016\/s0886-3350(01)00925-7","article-title":"Behavior of corneal endothelial density over a lifetime","volume":"27","author":"Abib","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"2593","DOI":"10.1007\/s00417-023-06079-0","article-title":"Semiautomatic assessment of endothelial density and morphology in organ-cultured corneas - potential predictors for transplantation suitability and clinical outcome?","volume":"261","author":"Filev","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"11884","DOI":"10.3390\/ijms252211884","article-title":"Factors affecting the density of corneal endothelial cells cultured from donor corneas","volume":"25","author":"Bertolin","year":"2024","journal-title":"Int J Mol Sci"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0002-9394(82)90693-6","article-title":"Clinical investigations on the corneal endothelium-XXXVIII Edward Jackson memorial lecture","volume":"93","author":"Mishima","year":"1982","journal-title":"Am J Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1982","DOI":"10.1016\/s0886-3350(02)01502-x","article-title":"Risk factors for reduced corneal endothelial cell density before cataract surgery","volume":"28","author":"Ishikawa","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1016\/S0161-6420(97)30134-1","article-title":"Corneal endothelial photography. Three-year revision. American Academy of ophthalmology","volume":"104","author":"Kenneth","year":"1997","journal-title":"Ophthalmology"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1016\/S0161-6420(84)34168-9","article-title":"Pseudophakic bullous keratopathy. Relationship to preoperative corneal endothelial status","volume":"91","author":"Rao","year":"1984","journal-title":"Ophthalmology"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"517","DOI":"10.4103\/ijo.IJO_574_20","article-title":"Specular microscopy in clinical practice","volume":"69","author":"Chaurasia","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/ICO.0b013e31815892da","article-title":"Review of corneal endothelial specular microscopy for FDA clinical trials of refractive procedures, surgical devices, and new intraocular drugs and solutions","volume":"27","author":"McCarey","year":"2008","journal-title":"Cornea"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/0002-9394(76)90247-6","article-title":"Specular microscopy of human corneal endothelium in VIVO","volume":"81","author":"Bourne","year":"1976","journal-title":"Am J Ophthalmol"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1167\/iovs.66.5.33","article-title":"Assessment of corneal endothelial barrier function based on \u201cY-junctions\u201d: a finite element analysis","volume":"66","author":"Li","year":"2025","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1016\/j.bioactmat.2025.10.029","article-title":"ECM stiffness governs endothelial barrier integrity through YAP-mediated stabilization of ZO-1","volume":"56","author":"Chi","year":"2026","journal-title":"Bioact Mater"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/j.oftal.2020.03.024","article-title":"Descemet membrane endothelial keratoplasty and corneal biomechanics","volume":"95","author":"Hern\u00e1ndez Esteban","year":"2020","journal-title":"Arch Soc Esp Oftalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"e0238395","DOI":"10.1371\/journal.pone.0238395","article-title":"Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma","volume":"15","author":"Nakao","year":"2020","journal-title":"PLoS One"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"625","DOI":"10.3928\/1081597X-20170621-03","article-title":"Comparison of corneal deformation parameters in keratoconic and normal eyes using a non-contact tonometer with a dynamic ultra-high-speed Scheimpflug camera","volume":"33","author":"Mercer","year":"2017","journal-title":"J Refract Surg"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"757959","DOI":"10.3389\/fmed.2021.757959","article-title":"Rate of cornea endothelial cell loss and biomechanical properties in Fuchs\u2019 endothelial corneal dystrophy","volume":"8","author":"Reinprayoon","year":"2021","journal-title":"Front Med"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1111\/opo.12768","article-title":"Dynamic corneal biomechanics in different cell layers: in keratoconus and normal eyes","volume":"41","author":"Alvani","year":"2021","journal-title":"Ophthalmic Physiol Opt"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/j.jcrs.2018.03.036","article-title":"Quantifying the effects of hydration on corneal stiffness with noncontact optical coherence elastography","volume":"44","author":"Singh","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.ophtha.2018.07.005","article-title":"Determining subclinical edema in Fuchs endothelial corneal dystrophy: revised classification using Scheimpflug tomography for preoperative assessment","volume":"126","author":"Sun","year":"2019","journal-title":"Ophthalmology"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1001\/jamaophthalmol.2018.0786","article-title":"Identification and description of reliable evidence for 2016 American Academy of ophthalmology preferred practice pattern guidelines for cataract in the adult eye","volume":"136","author":"Golozar","year":"2018","journal-title":"JAMA Ophthalmol"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"2270","DOI":"10.3390\/jcm10112270","article-title":"Accelerated corneal endothelial cell loss after phacoemulsification in patients with mildly low endothelial cell density","volume":"10","author":"Chen","year":"2021","journal-title":"J Clin Med"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1016\/j.jcrs.2011.02.025","article-title":"Cataract surgery in eyes with low corneal endothelial cell density","volume":"37","author":"Hayashi","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.tjem.2018.08.001","article-title":"User\u2019s guide to correlation coefficients","volume":"18","author":"Akoglu","year":"2018","journal-title":"Turk J Emerg Med"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"20626","DOI":"10.1038\/s41598-024-71676-w","article-title":"Corneal biomechanical properties and potential influencing factors in varying degrees of myopia","volume":"14","author":"Sun","year":"2024","journal-title":"Sci Rep"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"863240","DOI":"10.3389\/fbioe.2022.863240","article-title":"In vivo corneal biomechanical properties in a selected Chinese population, measured using the corneal visualization Scheimpflug technology","volume":"10","author":"Li","year":"2022","journal-title":"Front Bioeng Biotechnol"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1186\/s12886-024-03435-4","article-title":"Corneal endothelial cell density and associated factors among adults at a regional referral hospital in Uganda: a cross-sectional study","volume":"24","author":"Namwase","year":"2024","journal-title":"BMC Ophthalmol"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ajo.2024.01.036","article-title":"Association between endothelial cell density and corneal thickness in medium, short, and long eyes of Han Chinese cataract patients","volume":"262","author":"Miao","year":"2024","journal-title":"Am J Ophthalmol"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.exer.2016.09.004","article-title":"Biomechanical relationships between the corneal endothelium and Descemet\u2019s membrane","volume":"152","author":"Ali","year":"2016","journal-title":"Exp Eye Res"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"505","DOI":"10.3390\/cells14070505","article-title":"Preclinical models for studying Fuchs endothelial corneal dystrophy","volume":"14","author":"Sun","year":"2025","journal-title":"Cells"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"109303","DOI":"10.1016\/j.exer.2022.109303","article-title":"Cell derived matrices from bovine corneal endothelial cells as a model to study cellular dysfunction","volume":"226","author":"Jalilian","year":"2023","journal-title":"Exp Eye Res"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"100863","DOI":"10.1016\/j.preteyeres.2020.100863","article-title":"Fuchs endothelial corneal dystrophy: the vicious cycle of Fuchs pathogenesis","volume":"80","author":"Ong Tone","year":"2021","journal-title":"Prog Retin Eye Res"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"1445","DOI":"10.2147\/CIA.S51693","article-title":"Age-related changes in corneal thickness and endothelial characteristics","volume":"8","author":"Galgauskas","year":"2013","journal-title":"Clin Interv Aging"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.2147\/OPTH.S31821","article-title":"Central corneal thickness and corneal endothelial characteristics in healthy, cataract, and glaucoma patients","volume":"6","author":"Galgauskas","year":"2012","journal-title":"Clin Ophthalmol"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"178","DOI":"10.3390\/jfb4040178","article-title":"Tissue engineering of the corneal endothelium: a review of carrier materials","volume":"4","author":"Teichmann","year":"2013","journal-title":"J Funct Biomater"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"130","DOI":"10.3760\/cma.j.issn.2095-0160.2018.02.011","article-title":"Research of diagnostic value of corneal biomechanical parameters based on Corvis ST in keratoconus","volume":"36","author":"Wu","year":"2018","journal-title":"Zhonghua Shiyan Yanke Zazhi"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s40662-020-0174-x","article-title":"Biomechanical diagnostics of the cornea","volume":"7","author":"Esporcatte","year":"2020","journal-title":"Eye Vis"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1136\/bjophthalmol-2017-311627","article-title":"Biomechanical assessment of healthy and keratoconic corneas (with\/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L-A2L)","volume":"103","author":"Fuchsluger","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"ref44","doi-asserted-by":"publisher","first-page":"193","DOI":"10.3760\/CMA.J.ISSN.1674-845X.2019.03.007","article-title":"Evaluation of corneal biomechanical properties in high myopia using the Corivs ST and its correlation factors","volume":"3","author":"Shen","year":"2019","journal-title":"Chin J Optom Ophthalmol"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.ajo.2023.04.002","article-title":"Detection of keratoconus with a new Corvis biomechanical index optimized for Chinese populations","volume":"252","author":"Vinciguerra","year":"2023","journal-title":"Am J Ophthalmol"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1899851\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T11:10:21Z","timestamp":1785237021000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1899851\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,28]]},"references-count":45,"alternative-id":["10.3389\/fmed.2026.1899851"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1899851","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,28]]},"article-number":"1899851"}}