{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T06:16:01Z","timestamp":1788156961073,"version":"build-2803163510"},"reference-count":59,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T00:00:00Z","timestamp":1788134400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare the short-term clinical and radiographic outcomes of a 3D-printed trabecular titanium acetabular cup system (AK Medical, Beijing, China) with a conventional porous titanium-coated acetabular cup system (Pinnacle Gription Sector Acetabular System, DePuy Synthes\/Johnson &amp;amp; Johnson, USA) in primary total hip arthroplasty (THA) for Crowe type I\u2013III developmental dysplasia of the hip (DDH) with limited acetabular bone defects not requiring metal augments or structural bone grafting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective study included 104 patients (105 hips) who underwent primary THA for DDH between January 2022 and July 2023, including 51 hips in the 3D-printed trabecular titanium cup group and 54 hips in the conventional porous titanium-coated cup group, with a mean follow-up of approximately 24 months. The primary outcome was the proportion of cups meeting at least 3 of the 5 Moore radiographic criteria at final follow-up, with early revision classified as failure of the index cup. VAS and HHS were analyzed using patient-clustered generalized estimating equations (GEE). The primary radiographic endpoint was compared using Fisher's exact test, with stabilized inverse probability of treatment weighting (IPTW) used as an adjusted sensitivity analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Operative time, intraoperative blood loss, length of stay, and postoperative acetabular cup position parameters were similar between groups. VAS scores were lower in the 3D-printed cup group at 1 week, 1 month, and 3 months postoperatively. A significant group-by-time interaction was observed for HHS; HHS was higher in the 3D-printed group at 1 and 6 months, the between-group difference at 3 months did not reach statistical significance, and outcomes were similar between groups from 12 months onward. In the primary analysis, which conservatively classified early revision as failure, the proportions meeting the prespecified final-follow-up radiographic criterion were 46\/51 (90.2%) and 40\/54 (74.1%), respectively (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.042; crude OR\u2009=\u20093.22, 95% CI: 1.07\u20139.73). After stabilized IPTW, the weighted proportions were 92.9% and 75.7%, with a weighted OR of 4.21 (95% CI: 1.35\u201313.17,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.013). In the serial-radiograph subset of 82 hips, the proportions meeting the \u22653\/5 Moore criterion at 3 and 6 months were similar between groups and increased over time;\n                      <jats:italic>P<\/jats:italic>\n                      for the group-by-time interaction was 0.097. Complication events were infrequent, and safety findings were interpreted descriptively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In primary THA for Crowe type I\u2013III DDH with limited acetabular bone defects not requiring augments or structural bone grafting, the 3D-printed trabecular titanium acetabular cup system was associated with a higher proportion of hips meeting the final-follow-up radiographic integration endpoint and with better early VAS and HHS outcomes. No clear early between-group difference in the radiographic endpoint was observed at 3 or 6 months. This study compared two specific implant systems; longer follow-up is required to evaluate long-term fixation and implant survivorship.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1906028","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T05:41:47Z","timestamp":1788154907000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Short-term clinical and radiographic outcomes of a 3D-printed trabecular titanium acetabular cup in primary total hip arthroplasty for Crowe type I\u2013III developmental dysplasia of the hip with limited acetabular bone defects: a retrospective comparative study"],"prefix":"10.3389","volume":"13","author":[{"given":"Chengxiao","family":"Li","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lilei","family":"Song","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junheng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Hebei Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine","place":["Cangzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhaolong","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongqiang","family":"Fan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Binquan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiding","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Xiang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifan","family":"Niu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guangyang","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huijie","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Third Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,31]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e2227638","DOI":"10.1001\/jamanetworkopen.2022.27638","article-title":"Incidence of neonatal developmental dysplasia of the hip and late detection rates based on screening strategy","volume":"5","author":"Kuitunen","year":"2022","journal-title":"JAMA Netw Open"},{"key":"B2","doi-asserted-by":"publisher","first-page":"91","DOI":"10.5435\/Jaaos-D-18-00533","article-title":"Developmental dysplasia of the hip in adolescents and young adults","volume":"28","author":"Schmitz","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1302\/2058-5241.4.180019","article-title":"Developmental dysplasia of the hip: update of management","volume":"4","author":"Vaquero-Picado","year":"2019","journal-title":"Efort Open Rev"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1002\/jor.25165","article-title":"The biomechanical disadvantage of dysplastic hips","volume":"40","author":"Shahbazi","year":"2022","journal-title":"J Orthop Res"},{"key":"B5","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1051\/sicotj\/2023020","article-title":"Developmental dysplasia of the hip is common in patients undergoing total hip arthroplasty under 50 years of age","volume":"9","author":"Muddaluru","year":"2023","journal-title":"Sicot J"},{"key":"B6","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1111\/os.12846","article-title":"Minimum 7-year follow-up of a porous-coated trabecular titanium cup manufactured with electron beam melting technique in primary total hip arthroplasty","volume":"13","author":"Huang","year":"2021","journal-title":"Orthop Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"2401","DOI":"10.1111\/os.14143","article-title":"Integrated acetabular prosthesis versus bone grafting in total hip arthroplasty for crowe type ii and iii hip dysplasia: a retrospective case-control study","volume":"16","author":"Cheng","year":"2024","journal-title":"Orthop Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1186\/s13018-020-01913-1","article-title":"A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients","volume":"15","author":"Geng","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00590-023-03635-6","article-title":"The outcomes of total hip arthroplasty in developmental dysplasia of hip versus osteoarthritis: a systematic review and meta-analysis","volume":"34","author":"Salman","year":"2024","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"B10","first-page":"61","article-title":"Acetabular reconstruction using morcellised bone with ring support: medium-term results at three to nine years","volume":"77","author":"Harris","year":"2011","journal-title":"Acta Orthop Belg"},{"key":"B11","doi-asserted-by":"publisher","first-page":"495","DOI":"10.3390\/ma12030495","article-title":"Materials for hip prostheses: a review of wear and loading considerations","volume":"12","author":"Merola","year":"2019","journal-title":"Materials (Basel"},{"key":"B12","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1007\/s13534-018-0080-5","article-title":"Design and 3D-printing of titanium bone implants: brief review of approach and clinical cases","volume":"8","author":"Popov","year":"2018","journal-title":"Biomed Eng Lett"},{"key":"B13","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1016\/j.actbio.2017.09.013","article-title":"Mechanical characterization of structurally porous biomaterials built via additive manufacturing: experiments, predictive models, and design maps for load-bearing bone replacement implants","volume":"63","author":"Castagnini","year":"2017","journal-title":"Acta Biomater"},{"key":"B14","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1186\/s12891-022-05596-z","article-title":"Use of a new off-the-shelf 3D-printed trabecular titanium acetabular cup in Chinese patients undergoing hip revision surgery: short- to mid-term clinical and radiological outcomes","volume":"23","author":"Shang","year":"2022","journal-title":"Bmc Musculoskelet Disord"},{"key":"B15","doi-asserted-by":"publisher","first-page":"15","DOI":"10.2106\/00004623-197961010-00004","article-title":"Total hip replacement in congenital dislocation and dysplasia of the hip","volume":"61","author":"Crowe","year":"1979","journal-title":"J Bone Joint Surg Am"},{"key":"B16","doi-asserted-by":"publisher","first-page":"683","DOI":"10.2106\/00004623-199605000-00007","article-title":"Congenital hip disease in adults. Classification of acetabular deficiencies and operative treatment with acetabuloplasty combined with total hip arthroplasty","volume":"78","author":"Schmidt","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"B17","doi-asserted-by":"publisher","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","article-title":"Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation","volume":"51","author":"Harris","year":"1969","journal-title":"J Bone Joint Surg Am"},{"key":"B18","doi-asserted-by":"publisher","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","article-title":"Dislocations after total hip-replacement arthroplasties","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J Bone Joint Surg Am"},{"key":"B19","doi-asserted-by":"publisher","first-page":"4937151","DOI":"10.1155\/2017\/4937151","article-title":"Minimum lateral bone coverage required for securing fixation of cementless acetabular components in hip dysplasia","volume":"2017","author":"Fujii","year":"2017","journal-title":"Biomed Res Int"},{"key":"B20","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/00003086-197611000-00003","article-title":"Radiological demarcation of cemented sockets in total hip replacement","volume":"12","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"B21","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1007\/s13244-015-0438-5","article-title":"Postoperative radiograph of the hip arthroplasty: what the radiologist should know","volume":"6","author":"Vanrusselt","year":"2015","journal-title":"Insights Imaging"},{"key":"B22","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/01.blo.0000201149.14078.50","article-title":"Radiographic signs of osseointegration in porous-coated acetabular components","volume":"444","author":"Moore","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.1016\/j.arth.2017.12.037","article-title":"Accuracy of digital tomosynthesis with metal artifact reduction for detecting osteointegration in cementless hip arthroplasty","volume":"33","author":"Guo","year":"2018","journal-title":"J Arthroplasty"},{"key":"B24","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1186\/s12891-018-2259-4","article-title":"Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an uncemented acetabular cup component","volume":"19","author":"Jacobsen","year":"2018","journal-title":"Bmc Musculoskelet Disord"},{"key":"B25","doi-asserted-by":"publisher","first-page":"3063","DOI":"10.1007\/s00264-023-05949-w","article-title":"Risk factors for dislocation following total hip arthroplasty in developmental dysplasia of the hip: a systematic review and meta-analysis","volume":"47","author":"Nossa","year":"2023","journal-title":"Int Orthop"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1279194","DOI":"10.3389\/fsurg.2024.1279194","article-title":"A prospective and consecutive study assessing short-term clinical and radiographic outcomes of Chinese domestically manufactured 3D printing trabecular titanium acetabular cup for primary total hip arthroplasty: evaluation of 236 cases","volume":"11","author":"Chen","year":"2024","journal-title":"Front Surg"},{"key":"B27","doi-asserted-by":"publisher","first-page":"e0308813","DOI":"10.1371\/journal.pone.0308813","article-title":"Multiple risk factors are associated with an incremental increase in acute venous thromboembolism risk after total joint arthroplasty: a PearlDiver cohort study","volume":"19","author":"Kumar","year":"2024","journal-title":"PLoS One"},{"key":"B28","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1302\/0301-620X.108B5.Bjj-2025-0710.R2","article-title":"Acetabular components and additive manufacturing: does it all add up? A literature review of the current themes around the use of additive manufacturing in orthopaedic acetabular implants","author":"Aro","year":"2026","journal-title":"Bone Joint J"},{"key":"B29","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.jos.2018.03.007","article-title":"Initial stability of a highly porous titanium cup in an acetabular bone defect model","volume":"23","author":"Yoshimoto","year":"2018","journal-title":"J Orthop Sci"},{"key":"B30","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1302\/2046-3758.107.Bjr-2020-0462.R1","article-title":"Osseointegration of retrieved 3D-printed, off-the-shelf acetabular implants","volume":"10","author":"Dall\u2019Ava","year":"2021","journal-title":"Bone Joint Res"},{"key":"B31","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1016\/j.msec.2015.10.069","article-title":"Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment","volume":"59","author":"Kumar","year":"2016","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"B32","doi-asserted-by":"publisher","first-page":"682","DOI":"10.5312\/wjo.v14.i9.682","article-title":"Comparative study in vivo of the osseointegration of 3D-printed and plasma-coated titanium implants","volume":"14","author":"Polus","year":"2023","journal-title":"World J Orthop"},{"key":"B33","doi-asserted-by":"publisher","first-page":"48","DOI":"10.3109\/17453674.2015.1115312","article-title":"Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density: a 2-year rsa and 8-year radiographic follow-up study of 34 patients","volume":"87","author":"Finnil\u00e4","year":"2016","journal-title":"Acta Orthop"},{"key":"B34","doi-asserted-by":"publisher","first-page":"107","DOI":"10.3109\/17453674.2012.678798","article-title":"Low Bmd affects initial stability and delays stem osseointegration in cementless total hip arthroplasty in women: a 2-year rsa study of 39 patients","volume":"83","author":"Nam","year":"2012","journal-title":"Acta Orthop"},{"key":"B35","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1080\/17453670610046299","article-title":"Periacetabular bone changes after uncemented total hip arthroplasty evaluated by quantitative computed tomography","volume":"77","author":"Taniguchi","year":"2006","journal-title":"Acta Orthop"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1016\/j.arth.2011.09.031","article-title":"Periacetabular cortical and cancellous bone mineral density loss after press-fit cup fixation: a prospective 7-year follow-up","volume":"27","author":"Mueller","year":"2012","journal-title":"J Arthroplasty"},{"key":"B37","doi-asserted-by":"publisher","first-page":"583","DOI":"10.3109\/17453674.2012.745353","article-title":"Early proximal migration of cups is associated with late revision in tha: a systematic review and meta-analysis of 26 rsa studies and 49 survival studies","volume":"83","author":"Hartofilakidis","year":"2012","journal-title":"Acta Orthop"},{"key":"B38","doi-asserted-by":"publisher","first-page":"319","DOI":"10.2340\/17453674.2026.45784","article-title":"Early acetabular cup migration is associated with long-term aseptic loosening: investigation of 1-year and 2-year radiostereometric analysis cohort migration thresholds against acetabular cup survivorship from two national registries","volume":"97","author":"Pijls","year":"2026","journal-title":"Acta Orthop"},{"key":"B39","doi-asserted-by":"publisher","first-page":"2938","DOI":"10.1016\/j.arth.2025.05.024","article-title":"Application of three-dimensional printing integrated acetabular prosthesis in the treatment of hip dysplasia in total hip arthroplasty","volume":"40","author":"Bondarenko","year":"2025","journal-title":"J Arthroplasty"},{"key":"B40","doi-asserted-by":"publisher","first-page":"00610","DOI":"10.1016\/j.arth.2026.06.011","article-title":"Comparing clinical and radiological outcomes for a three-dimensional printed highly porous cup and a hydroxyapatite-coated non-highly porous cup in total hip arthroplasty using propensity score matching","author":"Okazaki","year":"2026","journal-title":"J Arthroplasty"},{"key":"B41","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1007\/s00264-021-05219-7","article-title":"The use of acetabular screws in total hip arthroplasty and its influence on wear and periacetabular osteolysis in the long-term follow-up","volume":"46","author":"Brodt","year":"2022","journal-title":"Int Orthop"},{"key":"B42","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1186\/s13018-023-03845-y","article-title":"Is the construct stability of the acetabular cup affected by the acetabular screw configuration in bone defect models?","volume":"18","author":"Brodt","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"B43","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1186\/s12891-024-07449-3","article-title":"Is ai 3D-printed psi an accurate option for patients with developmental dysplasia of the hip undergoing tha?","volume":"25","author":"Zheng","year":"2024","journal-title":"Bmc Musculoskelet Disord"},{"key":"B44","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1111\/os.13183","article-title":"Restoring rotation center in total hip arthroplasty for developmental dysplasia of the hip with the assistance of three dimensional printing technology: a pilot study","volume":"14","author":"Zhang","year":"2022","journal-title":"Orthop Surg"},{"key":"B45","doi-asserted-by":"publisher","first-page":"e92","DOI":"10.2106\/Jbjs.16.00729","article-title":"Morphological analysis of true acetabulum in hip dysplasia (crowe classes I-iv) via 3-D implantation simulation","volume":"99","author":"Fahlbusch","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"B46","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1302\/0301-620X.99B4.Bjj-2016-0041.R1","article-title":"Can we predict which dysplastic hips will require acetabular augmentation during total hip arthroplasty based on pre-operative radiographs?","author":"Yang","year":"2017","journal-title":"Bone Joint J"},{"key":"B47","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1097\/Corr.0000000000001618","article-title":"Does cup position at the high hip center or anatomic hip center in tha for developmental dysplasia of the hip result in better harris hip scores and revision incidence? A systematic review","volume":"479","author":"Melancon","year":"2021","journal-title":"Clin Orthop Relat Res"},{"key":"B48","doi-asserted-by":"publisher","first-page":"254","DOI":"10.5301\/hipint.5000577","article-title":"Leg length discrepancy after total hip arthroplasty: comparison of 3 intraoperative measurement methods","volume":"28","author":"Stirling","year":"2018","journal-title":"Hip Int"},{"key":"B49","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1016\/j.arth.2019.02.017","article-title":"High hip center reduces the dynamic hip range of motion and increases the hip load: a gait analysis study in hip arthroplasty patients with unilateral developmental dysplasia","volume":"34","author":"Zhang","year":"2019","journal-title":"J Arthroplasty"},{"key":"B50","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1177\/11207000231164711","article-title":"Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis","volume":"34","author":"Cho","year":"2024","journal-title":"Hip Int"},{"key":"B51","doi-asserted-by":"publisher","first-page":"6609","DOI":"10.1007\/s00402-023-04970-3","article-title":"Long-term outcomes of total hip arthroplasty in patients with developmental dysplasia of the hip: a minimum 21-year follow-up","volume":"143","author":"Okazaki","year":"2023","journal-title":"Arch Orthop Trauma Surg"},{"key":"B52","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1186\/s12891-015-0822-9","article-title":"Clinical and radiographic outcomes of a trabecular titanium acetabular component in hip arthroplasty: results at minimum 5 years follow-up","volume":"16","author":"Perticarini","year":"2015","journal-title":"Bmc Musculoskelet Disord"},{"key":"B53","doi-asserted-by":"publisher","first-page":"e103","DOI":"10.2106\/Jbjs.K.00011","article-title":"Adverse outcomes in hip arthroplasty: long-term trends","volume":"94","author":"Wolf","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"B54","doi-asserted-by":"publisher","first-page":"626","DOI":"10.2340\/17453674.2023.24580","article-title":"Migration patterns of acetabular cups: a systematic review and meta-analysis of Rsa studies","volume":"94","author":"Cho","year":"2023","journal-title":"Acta Orthop"},{"key":"B55","doi-asserted-by":"publisher","first-page":"103136","DOI":"10.1016\/j.otsr.2021.103136","article-title":"Liner type has no impact on bone mineral density changes around a 3D printed trabecular titanium acetabular component","volume":"109","author":"Finnil\u00e4","year":"2023","journal-title":"Orthop Traumatol Surg Res"},{"key":"B56","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1159\/000500876","article-title":"Highly porous titanium cups versus hydroxyapatite-coated sockets: midterm results in metachronous bilateral total hip arthroplasty","volume":"28","author":"Klasan","year":"2019","journal-title":"Med Princ Pract"},{"key":"B57","doi-asserted-by":"publisher","first-page":"376","DOI":"10.5312\/wjo.v12.i6.376","article-title":"Off-the-shelf 3D printed titanium cups in primary total hip arthroplasty","volume":"12","author":"Marsh","year":"2021","journal-title":"World J Orthop"},{"key":"B58","doi-asserted-by":"publisher","first-page":"393","DOI":"10.52198\/21.Sti.38.Os1398","article-title":"A new additive-manufactured cementless highly porous titanium acetabular cup for primary total hip arthroplasty: early two-year follow up","volume":"38","author":"Castagnini","year":"2021","journal-title":"Surg Technol Int"},{"key":"B59","doi-asserted-by":"publisher","first-page":"501","DOI":"10.5312\/wjo.v15.i6.501","article-title":"Dislocation of primary total hip arthroplasty: analysis of risk factors and preventive options","volume":"15","author":"Abdelaal","year":"2024","journal-title":"World J Orthop"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1906028\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T05:41:49Z","timestamp":1788154909000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1906028\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,31]]},"references-count":59,"alternative-id":["10.3389\/fmed.2026.1906028"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1906028","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,31]]},"article-number":"1906028"}}