{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T10:16:01Z","timestamp":1789121761851,"version":"build-2803163510"},"reference-count":37,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T00:00:00Z","timestamp":1789084800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100016077","name":"Dongguan Science and Technology Bureau","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100016077","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>Artificial airway placement bypasses the physiological warming and humidifying functions of the upper airway. This produces a distal shift of the isothermic saturation boundary and exposes the tracheobronchial mucosa to additional evaporative stress. When inspired gas is inadequately conditioned, the resulting evaporative stress can deplete airway surface liquid, concentrate mucus, impair mucociliary clearance, and promote secretion retention and mucus plugging. Airway hydration imbalance is not simply a problem of insufficient water delivery. Rather, it reflects a dynamic interaction among gas thermodynamics, epithelial ion transport, mucin network organization, inflammatory burden, secretion biophysics, and ventilator-patient conditions. Current humidification strategies, mainly heated humidifiers and heat-and-moisture exchangers, provide essential support during invasive and non-invasive ventilation. However, their performance is often constrained by open-loop operation, device-related limitations, and heterogeneous patient requirements. This review summarizes the physiological basis of airway hydration, the mechanisms by which artificial airways disturb hydration homeostasis, clinical assessment approaches, and current humidification strategies. It also discusses newer approaches, including ventilator waveform-derived indices, microrheological assays, artificial cilia sensors, microfluidic platforms, and closed-loop humidification frameworks. Future studies should determine whether integrating patient characteristics, secretion properties, ventilatory conditions, and device performance can support more individualized humidification strategies. Technologies that remain at the model or prototype stage should be interpreted cautiously.<\/jats:p>","DOI":"10.3389\/fmed.2026.1922639","type":"journal-article","created":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T09:12:40Z","timestamp":1789117960000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Airway hydration homeostasis in artificial airways: from mucus biophysics to monitoring and humidification strategies in critical care: a narrative review"],"prefix":"10.3389","volume":"13","author":[{"given":"Haishao","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Binhaiwan Central Hospital of Dongguan","place":["Dongguan, Guangdong, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xunbin","family":"Qiu","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Binhaiwan Central Hospital of Dongguan","place":["Dongguan, Guangdong, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaisheng","family":"Ye","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, The First Affiliated Hospital of Jinan University","place":["Guangzhou, Guangdong Province, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qun","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Binhaiwan Central Hospital of Dongguan","place":["Dongguan, Guangdong, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,11]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3390\/medsci12020026","article-title":"Humidification during invasive and non-invasive ventilation: a starting tool kit for correct setting","volume":"12","author":"Re","year":"2024","journal-title":"Med Sci (Basel)"},{"key":"B2","doi-asserted-by":"publisher","first-page":"782","DOI":"10.4187\/respcare.01766","article-title":"Humidification during invasive and noninvasive mechanical ventilation: 2012","volume":"57","author":"Restrepo","year":"2012","journal-title":"Respir Care"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1920","DOI":"10.1097\/00003246-199611000-00025","article-title":"Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa","volume":"24","author":"Williams","year":"1996","journal-title":"Crit Care Med"},{"key":"B4","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1126\/science.1223012","article-title":"A periciliary brush promotes lung health by separating the mucus layer from airway epithelia","volume":"337","author":"Button","year":"2012","journal-title":"Science"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/S0092-8674(00)81724-9","article-title":"Evidence for periciliary liquid layer depletion, not abnormal ion composition, in the pathogenesis of cystic fibrosis airways disease","volume":"95","author":"Matsui","year":"1998","journal-title":"Cell"},{"key":"B6","doi-asserted-by":"publisher","first-page":"2233","DOI":"10.1056\/NEJMra0910061","article-title":"Airway mucus function and dysfunction","volume":"363","author":"Fahy","year":"2010","journal-title":"N Engl J Med"},{"key":"B7","doi-asserted-by":"publisher","first-page":"e87681","DOI":"10.1371\/journal.pone.0087681","article-title":"A biophysical basis for mucus solids concentration as a candidate biomarker for airways disease","volume":"9","author":"Hill","year":"2014","journal-title":"PLoS One"},{"key":"B8","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1165\/rcmb.2015-0090OC","article-title":"Glandular proteome identifies antiprotease cystatin C as a critical modulator of airway hydration and clearance","volume":"54","author":"Evans","year":"2016","journal-title":"Am J Respir Cell Mol Biol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.rmed.2009.07.002","article-title":"Neutrophilic inflammation is associated with altered airway hydration in stable asthmatics","volume":"104","author":"Loughlin","year":"2010","journal-title":"Respir Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"6559","DOI":"10.1096\/fj.201800345R","article-title":"Cigarette smoke modifies and inactivates SPLUNC1, leading to airway dehydration","volume":"32","author":"Moore","year":"2018","journal-title":"FASEB J"},{"key":"B11","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.addr.2008.09.012","article-title":"Micro- and macrorheology of mucus","volume":"61","author":"Lai","year":"2009","journal-title":"Adv Drug Deliv Rev"},{"key":"B12","doi-asserted-by":"publisher","first-page":"7585","DOI":"10.1039\/d1sm00512j","article-title":"Magnetic wire active microrheology of human respiratory mucus","volume":"17","author":"Radiom","year":"2021","journal-title":"Soft Matter"},{"key":"B13","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1007\/s00134-020-05980-0","article-title":"Ventilator-associated pneumonia in adults: a narrative review","volume":"46","author":"Papazian","year":"2020","journal-title":"Intensive Care Med"},{"key":"B14","doi-asserted-by":"publisher","first-page":"R93","DOI":"10.1186\/cc11357","article-title":"Implications of endotracheal tube biofilm in ventilator-associated pneumonia response: a state of concept","volume":"16","author":"Gil-Perotin","year":"2012","journal-title":"Crit Care"},{"key":"B15","doi-asserted-by":"publisher","first-page":"CD004711","DOI":"10.1002\/14651858.CD004711.pub3","article-title":"Heat and moisture exchangers versus heated humidifiers for mechanically ventilated adults and children","volume":"9","author":"Gillies","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"key":"B16","doi-asserted-by":"publisher","first-page":"2481","DOI":"10.1002\/hed.24917","article-title":"Heated air humidification versus cold air nebulization in newly tracheostomized patients","volume":"39","author":"Birk","year":"2017","journal-title":"Head Neck"},{"key":"B17","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1177\/19433654251360619","article-title":"Management of body temperature via the respiratory tract","volume":"71","author":"Ring","year":"2026","journal-title":"Respir Care"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.4187\/respcare.12084","article-title":"Consequences of pausing heated humidification during invasive ventilation","volume":"69","author":"Lellouche","year":"2024","journal-title":"Respir Care"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1582","DOI":"10.1007\/s00134-002-1518-9","article-title":"Effect of the humidification device on the work of breathing during noninvasive ventilation","volume":"28","author":"Lellouche","year":"2002","journal-title":"Intensive Care Med"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.4187\/respcare.12007","article-title":"AARC Clinical practice guideline: patient-ventilator assessment","volume":"69","author":"Goodfellow","year":"2024","journal-title":"Respir Care"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1612501","DOI":"10.3389\/fphys.2025.1612501","article-title":"A feedback-driven ventilation model for assessing airway secretions in mechanically ventilated patients","volume":"16","author":"Anand","year":"2025","journal-title":"Front Physiol"},{"key":"B22","doi-asserted-by":"publisher","first-page":"e2412086121","DOI":"10.1073\/pnas.2412086121","article-title":"Sensory artificial cilia for in situ monitoring of airway physiological properties","volume":"121","author":"Wang","year":"2024","journal-title":"Proc Natl Acad Sci U S A"},{"key":"B23","doi-asserted-by":"publisher","first-page":"051503","DOI":"10.1063\/5.0161809","article-title":"Bio-inspired microfluidics: a review","volume":"17","author":"Raj","year":"2023","journal-title":"Biomicrofluidics"},{"key":"B24","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/j.ifacol.2021.10.274","article-title":"Digital twins in critical care: what, when, how, where, why?","volume":"54","author":"Chase","year":"2021","journal-title":"IFAC-PapersOnLine"},{"key":"B25","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.ccc.2018.03.012","article-title":"Automation of mechanical ventilation","volume":"34","author":"Branson","year":"2018","journal-title":"Crit Care Clin"},{"key":"B26","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1097\/EJA.0000000000001972","article-title":"Effects of closed loop ventilation on ventilator settings, patient outcomes and ICU staff workloads: a systematic review","volume":"41","author":"Goossen","year":"2024","journal-title":"Eur J Anaesthesiol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"1640","DOI":"10.1126\/science.1226325","article-title":"A physically transient form of silicon electronics","volume":"337","author":"Hwang","year":"2012","journal-title":"Science"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JMW.2025.3477655","article-title":"Innovations and challenges in RF antenna technologies for implantable medical devices communication","volume":"5","author":"Benaissa","year":"2025","journal-title":"IEEE J Microw"},{"key":"B29","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1007\/s13546-015-1131-x","article-title":"Quelle technique d'humidification pour la ventilation invasive et non invasive?","volume":"25","author":"Lellouche","year":"2016","journal-title":"R\u00e9animation"},{"key":"B30","doi-asserted-by":"publisher","first-page":"e59324","DOI":"10.7759\/cureus.59324","article-title":"The role of bronchoscopy and chest physiotherapy in postoperative patients with acute lung atelectasis due to airway mucus plugging: a case series and review of entity","volume":"16","author":"Athish","year":"2024","journal-title":"Cureus"},{"key":"B31","doi-asserted-by":"publisher","first-page":"29768675251349632","DOI":"10.1177\/29768675251349632","article-title":"Ventilator-associated pneumonia: an update on the role of lung ultrasound in adult, pediatric, and neonatal ICU practice","volume":"20","author":"Adri\u00e3o","year":"2025","journal-title":"Ther Adv Pulm Crit Care Med"},{"key":"B32","volume-title":"ISO 80601-2-74:2026 Medical Electrical Equipment\u2014Part 2-74: Particular Requirements for Basic Safety and Essential Performance of Respiratory Humidifying Equipment","year":"2026"},{"key":"B33","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1183\/09031936.00000208","article-title":"Comparison of two humidification systems for long-term noninvasive mechanical ventilation","volume":"32","author":"Nava","year":"2008","journal-title":"Eur Respir J"},{"key":"B34","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1164\/rccm.200309-1245OC","article-title":"Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers","volume":"170","author":"Lellouche","year":"2004","journal-title":"Am J Respir Crit Care Med"},{"key":"B35","doi-asserted-by":"publisher","first-page":"157","DOI":"10.4187\/respcare.09314","article-title":"Impact of airway humidification strategy in mechanically ventilated COVID-19 patients","volume":"67","author":"Lavoie-B\u00e9rard","year":"2022","journal-title":"Respir Care"},{"key":"B36","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1177\/0885066620981891","article-title":"Endotracheal tube obstruction among patients mechanically ventilated for ARDS due to COVID-19: a case series","volume":"36","author":"Wiles","year":"2021","journal-title":"J Intensive Care Med"},{"key":"B37","doi-asserted-by":"publisher","first-page":"e63","DOI":"10.1097\/SLA.0000000000004031","article-title":"Tracheobronchial slough, a potential pathology in endotracheal tube obstruction in patients with coronavirus disease 2019 (COVID-19) in the intensive care setting","volume":"272","author":"Rubano","year":"2020","journal-title":"Ann Surg"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1922639\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T09:12:42Z","timestamp":1789117962000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1922639\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,11]]},"references-count":37,"alternative-id":["10.3389\/fmed.2026.1922639"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1922639","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,11]]},"article-number":"1922639"}}