{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T10:43:23Z","timestamp":1780742603588,"version":"3.54.1"},"reference-count":25,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,2,9]],"date-time":"2021-02-09T00:00:00Z","timestamp":1612828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:p><jats:bold>Background and Aims:<\/jats:bold> Colonoscopy surveillance depends on effective bowel preparation. Inadequate bowel preparation can lead to inaccurate clinical diagnosis, insufficient visualization of the colon and increased risk of missed diagnosis. This study aimed to compare the efficacy and safety of a novel Capsule Bowel Preparation (RitePrep), high-volume (2L) polyethylene glycol electrolyte solution (MoviPrep\u00ae) and low-volume (1L) polyethylene glycol electrolyte solution (Plenvu\u2122).<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Patients (<jats:italic>n<\/jats:italic> = 120) were divided into three groups and were administered either RitePrep, MoviPrep\u00ae or Plenvu\u2122 as a pre-colonoscopy bowel preparation followed by a colonoscopy at a single center. Validated Boston Bowel Preparation Score (BBPS) and bubble score were used to evaluate bowel cleanliness. Blood tests were also evaluated. The scores and the blood results were analyzed using Kruskal-Wallis and Chi-squared tests.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> A total of 120 patients (median age of 55; 57 males) [RitePrep (<jats:italic>n<\/jats:italic> = 40), MoviPrep\u00ae (<jats:italic>n<\/jats:italic> = 40) and Plenvu\u2122 (<jats:italic>n<\/jats:italic> = 40)] were included in the study. RitePrep was the most effective method for cleansing the bowel, with a significantly higher median BBPS compared to MoviPrep\u00ae and Plenvu\u2122 (<jats:italic>p<\/jats:italic> = 0.006 and 0.024, respectively). Nearly 50% of the patients in Plenvu\u2122 group showed increased serum osmolality disturbance. Nausea and vomiting were higher in Plenvu\u2122 and MoviPrep\u00ae groups than RitePrep group.<\/jats:p><jats:p><jats:bold>Conclusions:<\/jats:bold> RitePrep was demonstrated to be a more effective and safe preparation than the other two preparations. RitePrep was not only well-tolerated by all patients; the preparation sufficiently cleared the ascending, transverse, and descending colon, enabling optimal visualization for the clinician. RitePrep was also much safer than the comparators, with no alteration in electrolytes measured. For both the clinician and the patient, RitePrep was the preferred preparation.<\/jats:p>","DOI":"10.3389\/fmedt.2020.622252","type":"journal-article","created":{"date-parts":[[2021,2,9]],"date-time":"2021-02-09T08:39:05Z","timestamp":1612859945000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["A Comparative Clinical Study of a Novel Pre-colonoscopy Bowel Capsule Preparation Against Two Commercially Available Liquid Preparations"],"prefix":"10.3389","volume":"2","author":[{"given":"Harriet","family":"Kingston-Smith","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anoja W.","family":"Gunaratne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Saxon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjay","family":"Ramrakha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie Vic M.","family":"Dawson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annabel","family":"Clancy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antony","family":"Wettstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas J.","family":"Borody","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,2,9]]},"reference":[{"key":"B1","first-page":"3","article-title":"Current issues in optimal bowel preparation: excerpts from a roundtable discussion among colon-cleansing experts","volume":"5","author":"Cohen","year":"2009","journal-title":"J Gastroenterol Hepatol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1067\/mge.2003.294","article-title":"Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia","volume":"58","author":"Harewood","year":"2003","journal-title":"Gastrointest Endosc"},{"key":"B3","doi-asserted-by":"publisher","first-page":"63","DOI":"10.3348\/kjr.2009.10.1.63","article-title":"Gastrointestinal tract perforation: MDCT findings according to the perforation sites","volume":"10","author":"Kim","year":"2009","journal-title":"Korean J Radiol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1155\/2011\/628786","article-title":"Seeking the ultimate bowel preparation for colonoscopy: is the end in sight?","volume":"25","author":"Hilsden","year":"2011","journal-title":"Can J Gastroenterol Hepatol"},{"key":"B5","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1067\/mge.2002.129221","article-title":"Carbohydrate-electrolyte rehydration protects against intravascular volume contraction during colonic cleansing with orally administered sodium phosphate","volume":"56","author":"Barclay","year":"2002","journal-title":"Gastrointest Endosc"},{"key":"B6","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1097\/01.SGA.0000310933.54551.ca","article-title":"Key safety issues of bowel preparations for colonoscopy and importance of adequate hydration","volume":"31","author":"Dykes","year":"2008","journal-title":"Gastroenterol Nurs."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1016\/j.cgh.2012.08.029","article-title":"4-Liter split-dose polyethylene glycol is superior to other bowel preparations, based on systematic review and meta-analysis","volume":"10","author":"Enestvedt","year":"2012","journal-title":"Clin Gastroenterol Hepatol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1111\/j.1463-1318.2006.00970.x","article-title":"Which is the optimal bowel preparation for colonoscopy - a meta-analysis","volume":"8","author":"Tan","year":"2006","journal-title":"Colorectal Dis"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1007\/s10350-004-0559-2","article-title":"Carbohydrate-electrolyte (E-Lyte) solution enhances bowel preparation with oral fleet phospho-soda","volume":"47","author":"Tjandra","year":"2004","journal-title":"Dis Colon Rectum"},{"key":"B10","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/S0016-5107(04)02776-2","article-title":"Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European panel of appropriateness of gastrointestinal endoscopy European multicenter study","volume":"61","author":"Froehlich","year":"2005","journal-title":"Gastrointest Endosc"},{"key":"B11","doi-asserted-by":"publisher","first-page":"3186","DOI":"10.1111\/j.1572-0241.2002.07129.x","article-title":"A prospective, controlled assessment of factors influencing acceptance of screening colonoscopy","volume":"97","author":"Harewood","year":"2002","journal-title":"Am J Gastroenterol"},{"key":"B12","unstructured":"Preparation Instruction Manual for Plenuv2018"},{"key":"B13","unstructured":"Preparation Instruction Manual for MOVIPREP2018"},{"key":"B14","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1159\/000485567","article-title":"Clinical practice impact of the boston bowel preparation scale in a European country","volume":"25","author":"Massinha","year":"2018","journal-title":"GE Port J Gastroenterol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"AB274","DOI":"10.1016\/j.gie.2010.03.640","article-title":"The incidence, severity and distribution of colonic bubbles after bowel preparation with split dose 2L polyethylene glycol-electrolyte solution with sodium sulfate, sodium ascorbate and ascorbic acid (PEG-ELS): a pilot study","volume":"71","author":"Rubin","year":"2010","journal-title":"Gastrointest Endosc"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/j.gie.2012.01.005","article-title":"Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy","volume":"75","author":"Chokshi","year":"2012","journal-title":"Gastrointest Endosc"},{"key":"B17","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1093\/jnci\/djp436","article-title":"Protection from right- and left-sided colorectal neoplasms after colonoscopy: population-based study","volume":"102","author":"Brenner","year":"2010","journal-title":"J Natl Cancer Inst"},{"key":"B18","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.gie.2011.04.005","article-title":"Miss rate of right-sided colon examination during colonoscopy defined by retroflexion: an observational study","volume":"74","author":"Hewett","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"B19","doi-asserted-by":"publisher","first-page":"219","DOI":"10.4103\/1319-3767.136950","article-title":"A Korean experience of the use of Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research","volume":"20","author":"Kim","year":"2014","journal-title":"Saudi J Gastroenterol."},{"key":"B20","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.gie.2014.10.032","article-title":"Good is better than excellent: bowel preparation quality and adenoma detection rates","volume":"81","author":"Calderwood","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"B21","first-page":"127","article-title":"Treatment of chronic constipation with a contact laxative in pearl form: bisoxatin acetate","volume":"27","author":"Mattivi","year":"1972","journal-title":"Atti Accad Med Lomb"},{"key":"B22","first-page":"386","article-title":"Treatment of acute and chronic constipation with bisoxatin acetate and bisacodyl. Double-blind crossover study","volume":"13","author":"Rider","year":"1971","journal-title":"Curr Ther Res Clin Exp"},{"key":"B23","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/01.mcg.0000212662.66644.76","article-title":"Tolerability and patient acceptance of sodium phosphate tablets compared with 4-L PEG solution in colon cleansing: combined results of 2 identically designed, randomized, controlled, parallel group, multicenter phase 3 trials","volume":"41","author":"Kastenberg","year":"2007","journal-title":"J Clin Gastroenterol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1111\/j.1365-2036.2007.03496.x","article-title":"Clinical trial: sodium phosphate tablets are preferred and better tolerated by patients compared to polyethylene glycol solution plus bisacodyl tablets for bowel preparation","volume":"26","author":"Lichtenstein","year":"2007","journal-title":"Aliment Pharmacol Ther"},{"key":"B25","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1016\/j.gie.2018.11.009","article-title":"Hyperosmotic low-volume bowel preparations: Is NER1006 safe?","volume":"89","author":"Rex","year":"2019","journal-title":"Gastrointest Endosc."}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2020.622252\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,9]],"date-time":"2021-02-09T08:39:12Z","timestamp":1612859952000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2020.622252\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,9]]},"references-count":25,"alternative-id":["10.3389\/fmedt.2020.622252"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2020.622252","relation":{},"ISSN":["2673-3129"],"issn-type":[{"value":"2673-3129","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,9]]},"article-number":"622252"}}