{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T14:48:12Z","timestamp":1792853292538,"version":"4.5.0"},"reference-count":71,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T00:00:00Z","timestamp":1652745600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:p>Hypertension remains the leading risk factor for death worldwide. Despite its prevalence, success of blood pressure (BP) management efforts remains elusive, and part of the difficulty lies in the tool still used to diagnose, measure, and treat hypertension: the sphygmomanometer introduced by Samuel Siegfried Karl von Basch in 1867. In recent years, there has been an explosion of devices attempting to provide estimates of BP without a cuff, overcoming many limitations of cuff-based BP monitors. Unfortunately, the differences in underlying technologies between traditional BP cuffs and newer cuffless devices, as well as hesitancy of changing a well-implemented standard, still generate understandable skepticism about and reluctance to adopt cuffless BP monitors in clinical practice. This guidance document aims to navigate the scientific and medical communities through the types of cuffless devices and present examples of robust BP data collection which are better representations of a person's true BP. It highlights the differences between data collected by cuffless and traditional cuff-based devices and provides an initial framework of interpretation of the new cuffless datasets using, as an example, a CE-marked continual cuffless BP device (Aktiia BP Monitor, Aktiia, Switzerland). Demonstration of novel BP metrics, which have the potential to change the paradigm of hypertension diagnosis and treatment, are now possible for the first time with cuffless BP monitors that provide continual readings over long periods. Widespread adoption of continual cuffless BP monitors in healthcare will require a collaborative and thoughtful process, acknowledging that the transition from a legacy to a novel medical technology will be slow. Finally, this guidance concludes with a call to action to international scientific and expert associations to include cuffless BP monitors in original scientific research and in future versions of guidelines and standards.<\/jats:p>","DOI":"10.3389\/fmedt.2022.899143","type":"journal-article","created":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T07:48:44Z","timestamp":1652773724000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":30,"title":["Guidance for the Interpretation of Continual Cuffless Blood Pressure Data for the Diagnosis and Management of Hypertension"],"prefix":"10.3389","volume":"4","author":[{"given":"Josep","family":"Sola","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meritxell","family":"Cortes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Perruchoud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastien","family":"De Marco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melvin D.","family":"Lobo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Pellaton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregoire","family":"Wuerzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naomi D. L.","family":"Fisher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Shah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,5,17]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1038\/s41581-019-0244-2","article-title":"The global epidemiology of hypertension","volume":"16","author":"Mills","year":"2020","journal-title":"Nature Rev. Nephrology."},{"key":"B2","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/S0140-6736(21)01330-1","article-title":"Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participants","volume":"398","year":"2021","journal-title":"Lancet."},{"key":"B3","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1001\/jama.2016.13614","article-title":"Temporal changes in the association between modifiable risk factors and coronary heart disease incidence","volume":"316","author":"Navar","year":"2016","journal-title":"JAMA"},{"key":"B4","doi-asserted-by":"publisher","first-page":"e008731","DOI":"10.1161\/JAHA.118.008731","article-title":"Trends in healthcare expenditures among US adults with hypertension: National Estimates, 2003-2014","volume":"7","author":"Kirkland","year":"2018","journal-title":"J Am Heart Assoc."},{"key":"B5","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1007\/s11906-013-0340-9","article-title":"High blood pressure: the leading global burden of disease risk factor and the need for worldwide prevention programs","volume":"15","author":"Bromfield","year":"2013","journal-title":"Curr Hypertens Rep."},{"key":"B6","volume-title":"Crossing the Quality Chasm: A New Health System for the 21st Century.","year":"2001"},{"key":"B7","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1161\/01.HYP.13.5_Suppl.I13","article-title":"Blood pressure as a risk factor for cardiovascular disease. The Framingham Study\u221230 years of follow-up","volume":"13","author":"Stokes","year":"1989","journal-title":"Hypertension."},{"key":"B8","doi-asserted-by":"crossref","DOI":"10.4159\/harvard.9780674492097","volume-title":"The Framingham Study: The Epidemiology of Atherosclerotic Disease","author":"Dawber","year":"1980"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1097\/HJH.0000000000002843","article-title":"European Society of Hypertension practice guidelines for office and out-of-office blood pressure measurement","volume":"39","author":"Stergiou","year":"2021","journal-title":"J Hypertens."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1161\/HYPERTENSIONAHA.120.15026","article-title":"International society of hypertension global hypertension practice guidelines","volume":"75","author":"Unger","year":"2020","journal-title":"Hypertension."},{"key":"B11","doi-asserted-by":"publisher","first-page":"e127","DOI":"10.1016\/j.jacc.2017.11.006","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Pr","volume":"71","author":"Whelton","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1161\/01.HYP.0000150859.47929.8e","article-title":"Recommendations for blood pressure measurement in humans and experimental animals part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the american heart association coun","volume":"45","author":"T","year":"2005","journal-title":"Hypertension."},{"key":"B13","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1161\/HYPERTENSIONAHA.115.06818","article-title":"Snapshot hemodynamics and clinical outcomes in hypertension precision in the measurements is key","volume":"67","author":"Pandit","year":"2016","journal-title":"Hypertension."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.2215\/CJN.03680320","article-title":"Cuffless blood pressure monitoring promises and challenges","volume":"15","author":"Pandit","year":"2020","journal-title":"Clin J Am Soc Nephrol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"3021","DOI":"10.1097\/HJH.0000000000001961","article-title":"2018 ESC\/ESH Guidelines for the management of arterial hypertension: The Task Force for the management of arterial hypertension of the European Society of Cardiology (ESC) and the European Society of Hypertension (ESH)","volume":"39","author":"Williams","year":"2018","journal-title":"Eur. Heart J."},{"key":"B16","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1016\/j.jash.2014.09.015","article-title":"The use of ambulatory blood pressure monitoring among Medicare beneficiaries in 2007-2010","volume":"8","author":"Shimbo","year":"2014","journal-title":"J Am Soc Hypertens."},{"key":"B17","doi-asserted-by":"publisher","first-page":"e344","DOI":"10.1097\/01.hjh.0000748512.79946.01","article-title":"What are the preferred blood pressure measurement methods by doctors to detect diagnose and treat hypertension? A survey study in a Chinese population","volume":"39","author":"Lee","year":"2021","journal-title":"J Hypertens"},{"key":"B18","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/j.jash.2017.06.012","article-title":"Barriers to conducting ambulatory and home blood pressure monitoring during hypertension screening in the United States","volume":"11","author":"Kronish","year":"2017","journal-title":"J Am Soc Hypertens"},{"key":"B19","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-030-24701-0","volume-title":"The Handbook of Cuffless Blood Pressure Monitoring, A Practical Guide for Clinicians, Researchers, and Engineers","author":"Sol\u00e0","year":"2019"},{"key":"B20","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4684-7170-0","volume-title":"Handbook of Blood Pressure Measuremen.","author":"Geddes","year":"1991"},{"key":"B21","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-319-40501-8","volume-title":"Pulse Waves","author":"Salvi","year":"2017"},{"key":"B22","volume-title":"Photoplethysmography","author":"Kyriacou","year":"2021"},{"key":"B23","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1515\/bmt-2017-0119","article-title":"Cardiovascular assessment by imaging photoplethysmography \u2013 a review","volume":"63","author":"Zaunseder","year":"2018","journal-title":"J Biomed Eng"},{"key":"B24","volume-title":"Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields","author":"Malmivuo","year":"2012"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.3390\/s20051454","article-title":"Human vital signs detection methods and potential using radars: a review","volume":"20","author":"Kebe","year":"2020","journal-title":"Sensors"},{"key":"B26","volume-title":"Continuous non-invasive blood pressure estimation, e ETH Zurich Research Collection","author":"Sola","year":"2011"},{"key":"B27","year":"2018"},{"key":"B28","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1161\/HYPERTENSIONAHA.117.10237","article-title":"A universal standard for the validation of blood pressure measuring devices","volume":"71","author":"Stergiou","year":"2018","journal-title":"Hypertension"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1161\/HYPERTENSIONAHA.121.17747","article-title":"Evaluation of the accuracy of cuffless blood pressure measurement devices: challenges and proposals","volume":"78","author":"Mukkamala","year":"2021","journal-title":"Hypertension"},{"key":"B30","volume-title":"1708 - IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices","year":"2019"},{"key":"B31","year":"2021"},{"key":"B32","year":"2019","journal-title":"Factors to Consider When Making Benefit-Risk Determinations in Medical Device Premarket Approval and De Novo Classifications, U.S. Department of Health and Human Services - Food and Drug Administration."},{"key":"B33","year":"2020","journal-title":"MDCG 2020-13 Clinical evaluation assessment report template, EU - Medical Devices Coordination Group Document"},{"key":"B34","volume-title":"ISO 14971:2019 Medical devices \u2014 Application of risk management to medical devices.","year":"2019"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1111\/jch.13304","article-title":"Blood pressure variability: clinical relevance and application","volume":"20","author":"Parati","year":"2018","journal-title":"J Clini Hypertens"},{"key":"B36","doi-asserted-by":"publisher","first-page":"2095","DOI":"10.1097\/HJH.0000000000002522","article-title":"Short-term reproducibility of ambulatory blood pressure measurements: a systematic review and meta-analysis of 35 observational studies","volume":"38","author":"Bo","year":"2020","journal-title":"J Hypertens"},{"key":"B37","unstructured":"Neuchatel. Rockville, MDU.S. National Library of MedicineNCT04548986 - Single-center Prospective Study to Validate the Performance of the Aktiia Optical Blood Pressure Monitoring (OBPM) Device at the Wrist Against Ambulatory Blood Pressure Monitoring (ABPM) (OBPM_ABPM2020)2020"},{"key":"B38","doi-asserted-by":"publisher","first-page":"2061","DOI":"10.1097\/00004872-200411000-00005","article-title":"Assessing circadian blood pressure and heart rate changes: advantages and limitations of different methods of mathematical modelling","volume":"22","author":"Parati","year":"2004","journal-title":"J Hypertens"},{"key":"B39","doi-asserted-by":"publisher","first-page":"1810","DOI":"10.1161\/CIRCULATIONAHA.120.049730","article-title":"Nighttime blood pressure phenotype and cardiovascular prognosis","volume":"142","author":"Kario","year":"2020","journal-title":"Circulation"},{"key":"B40","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1001\/archinte.160.9.1251","article-title":"Home blood pressure monitoring","volume":"160","author":"Yarows","year":"2000","journal-title":"JAMA Int Med"},{"key":"B41","doi-asserted-by":"publisher","first-page":"e007131","DOI":"10.1161\/JAHA.117.007131","article-title":"Time in therapeutic range, as a determinant of all-cause mortality in patients with hypertension","volume":"6","author":"Doumas","year":"2017","journal-title":"J Am Heart Assoc"},{"key":"B42","doi-asserted-by":"publisher","first-page":"1290","DOI":"10.1016\/j.jacc.2021.01.014","article-title":"Systolic blood pressure time in target range and cardiovascular outcomes in patients with hypertension","volume":"77","author":"Fatani","year":"2021","journal-title":"JACC"},{"key":"B43","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.1016\/j.jacc.2021.01.019","article-title":"Time in therapeutic range: redefining optimalblood pressure control","volume":"77","author":"Bakris","year":"2021","journal-title":"JACC"},{"key":"B44","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1023\/B:THRO.0000011377.78585.63","article-title":"Quality assessment of anticoagulation dose management: comparative evaluation of measures of time-in-therapeutic range","volume":"15","author":"Schmitt","year":"2003","journal-title":"J Thrombosis Thromboly."},{"key":"B45","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1161\/01.HYP.0000170138.56903.7a","article-title":"Superiority of ambulatory over clinic blood pressure measurement in predicting mortality","volume":"46","author":"Dolan","year":"2005","journal-title":"Hypertension"},{"key":"B46","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1161\/01.CIR.0000160923.04524.5B","article-title":"Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population","volume":"111","author":"Sega","year":"2005","journal-title":"Circulation"},{"key":"B47","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1038\/ajh.2012.49","article-title":"Nocturnal hypertension and organ damage in dippers and nondippers","volume":"25","author":"Cuspidi","year":"2012","journal-title":"Am J Hypertens"},{"key":"B48","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/S0895-7061(97)00497-4","article-title":"Limited reproducibility of circadian variation in blood pressure dippers and nondippers","volume":"11","author":"Mochizuki","year":"1998","journal-title":"Am J Hypertens"},{"key":"B49","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1161\/HYPERTENSIONAHA.120.16827","article-title":"Short- and long-term reproducibility of nighttime blood pressure phenotypes and nocturnal blood pressure reduction","volume":"77","author":"Mancia","year":"2021","journal-title":"Hypertension"},{"key":"B50","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2288-11-59","article-title":"Tolerability of the oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study","volume":"11","author":"Viera","year":"2011","journal-title":"BMC Med Res Methodol"},{"key":"B51","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1097\/MBP.0000000000000354","article-title":"Ambulatory blood pressure monitoring tolerability and blood pressure status in adolescents: the SHIP AHOY study","volume":"24","author":"Hamdani","year":"2019","journal-title":"Blood Press Monit"},{"key":"B52","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1161\/01.HYP.0000258215.26755.20","article-title":"Ambulatory blood pressure and cardiovascular outcome in relation to perceived sleep deprivation","volume":"49","author":"Verdecchia","year":"2007","journal-title":"Hypertension"},{"key":"B53","doi-asserted-by":"publisher","first-page":"1871","DOI":"10.1111\/j.1475-6773.2006.00689.x","article-title":"Time allocation in primary care office visits","volume":"42","author":"Tai-Seale","year":"2007","journal-title":"Health Serv Res."},{"key":"B54","doi-asserted-by":"publisher","first-page":"e4","DOI":"10.2196\/jmir.8.1.e4","article-title":"What Is eHealth (6): perspectives on the evolution of eHealth research","volume":"8","author":"Ahern","year":"2006","journal-title":"JMIR"},{"key":"B55","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/S1386-5056(02)00048-5","article-title":"CHESS: 10 years of research and development in consumer health informatics for broad populations, including the underserved","volume":"65","author":"Gustafson","year":"2002","journal-title":"Int J Med Inform"},{"key":"B56","unstructured":"Pew Research Center.2021"},{"key":"B57","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1197\/jamia.M2492","article-title":"Patient-centered applications: use of information technology to promote disease management and wellness. A white paper by the AMIA knowledge in motion working group","volume":"15","author":"Demiris","year":"2008","journal-title":"J Am Med Inform Assoc"},{"key":"B58","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1136\/jamia.1998.0050257","article-title":"Improving health care by understanding patient preferences the role of computer technology","volume":"5","author":"Brennan","year":"1998","journal-title":"J Am Med Inform Assoc"},{"key":"B59","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.amjmed.2016.07.029","article-title":"Improving hypertension control and patient engagement using digital tools","volume":"130","author":"Milani","year":"2017","journal-title":"Am J Med"},{"key":"B60","doi-asserted-by":"publisher","first-page":"e2127009","DOI":"10.1001\/jamanetworkopen.2021.27008","article-title":"Assessment of hypertension control among adults participating in a mobile technology blood pressure self-management program","volume":"4","author":"Gazit","year":"2021","journal-title":"JAMA Netw Open"},{"key":"B61","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1161\/01.HYP.0000200702.76436.4b","article-title":"Therapeutic inertia is an impediment to achieving the healthy people 2010 blood pressure control goals","volume":"47","author":"Okonofua","year":"2006","journal-title":"Hypertension"},{"key":"B62","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.amjmed.2014.10.047","article-title":"Health care 2020: reengineering health care delivery to combat chronic disease","volume":"128","author":"Milani","year":"2015","journal-title":"Am J of Medicine"},{"key":"B63","doi-asserted-by":"publisher","first-page":"2185","DOI":"10.1016\/j.jacc.2013.07.083","article-title":"Lipid control in the modern era: an orphan's tale of rags to riches","volume":"62","author":"Milani","year":"2013","journal-title":"JACC"},{"key":"B64","doi-asserted-by":"publisher","first-page":"e13555","DOI":"10.2196\/13555","article-title":"Clinicians' role in the adoption of an oncology decision support app in europe and its implications for organizational practices: qualitative case study","volume":"7","author":"Jacob","year":"2019","journal-title":"JMIR Mhealth Uhealth"},{"key":"B65","doi-asserted-by":"publisher","first-page":"e18072","DOI":"10.2196\/18072","article-title":"Understanding clinicians' adoption of mobile health tools: a qualitative review of the most used frameworks","volume":"8","author":"Jacob","year":"2020","journal-title":"JMIR Mhealth Uhealth"},{"key":"B66","doi-asserted-by":"publisher","first-page":"3729","DOI":"10.1007\/s00520-018-4234-x","article-title":"Using patient-reported outcome measures to deliver enhanced supportive care to people with lung cancer: feasibility and acceptability of a nurse-led consultation mode","volume":"26","author":"Kotronoulas","year":"2018","journal-title":"Support Care Cancer"},{"key":"B67","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1159\/000507345","article-title":"Consilium smartphone app for real-world electronically captured patient-reported outcome monitoring in cancer patients undergoing anti-pd-l1-directed treatment","volume":"13","author":"Trojan","year":"2020","journal-title":"Case Rep Oncol"},{"key":"B68","doi-asserted-by":"publisher","first-page":"2510","DOI":"10.1016\/j.mayocp.2019.04.018","article-title":"Barriers to use of telepsychiatry: clinicians as gatekeepers","volume":"94","author":"Cowan","year":"2019","journal-title":"Mayo Clinic Proc"},{"key":"B69","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1186\/s12992-017-0275-z","article-title":"Beyond pilotitis: taking digital health interventions to the national level in China and Uganda","volume":"13","author":"Huang","year":"2017","journal-title":"Global Health"},{"key":"B70","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1111\/j.1365-2575.2010.00358.x","article-title":"Towards consistent modes of e-health implementation: structurational analysis of a telecare programmes limited success","volume":"20","author":"Boonstra","year":"2010","journal-title":"Informat. Systems J"},{"key":"B71","doi-asserted-by":"publisher","first-page":"e321","DOI":"10.3399\/bjgp19X702401","article-title":"GPs' and practice staff's views of a telephone first approach to demand management: a qualitative study in primary care","volume":"69","author":"Newbould","year":"2019","journal-title":"Br J of General Practice"}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2022.899143\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T07:49:00Z","timestamp":1652773740000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2022.899143\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,17]]},"references-count":71,"alternative-id":["10.3389\/fmedt.2022.899143"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2022.899143","relation":{},"ISSN":["2673-3129"],"issn-type":[{"value":"2673-3129","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,17]]},"article-number":"899143"}}