{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:19:12Z","timestamp":1787026752877,"version":"build-2736575974"},"reference-count":33,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T00:00:00Z","timestamp":1747008000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Quantitative computed tomography (QCT) has received growing attention for its utility in bone mineral density (BMD) assessment and osteoporosis diagnosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To assess the accuracy and precision of lumbar spine BMD measurements obtained using low-dose iCare QCT, based on the European Spine Phantom (ESP).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Paired\n                      <jats:italic>t<\/jats:italic>\n                      -test was employed to compare BMD values measured under normal-dose and low-dose scan protocols using Mindways and iCare QCT systems. Accuracy was evaluated using relative measurement error (RME), and precision was assessed via relative standard deviation (RSD). Pearson correlation coefficients and Bland-Altman analysis were used to examine measurement correlation and agreement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>For Mindways QCT, RMEs of L1\u2013L3 were 11.89%, 6.94%, and 6.72% under normal-dose, and 6.65%, 10.5%, and 6.31% under low-dose, respectively. For iCare QCT, RMEs were 1.21%, 4.28%, and 8.88% under normal-dose, and 2.14%, 4.96%, and 8.59% under low-dose, respectively. RSDs of L1\u2013L3 for Mindways QCT were 5.16%, 2.85%, and 0.47% under normal-dose, and 9.08%, 4.69%, and 0.49% under low-dose, respectively. For iCare QCT, RSDs were 1.11%, 0.81%, and 0.45% under normal-dose, and 2.34%, 0.85%, and 0.33% under low-dose, respectively. The radiation dose in the low-dose protocol was significantly reduced compared with the normal-dose protocol.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Low-dose iCare QCT exhibited high accuracy and precision in measuring lumbar spine BMD, achieving an approximately 85% reduction in radiation dose. These findings highlight its potential as a safer and reliable tool for clinical application.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmedt.2025.1575553","type":"journal-article","created":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T04:43:14Z","timestamp":1747111394000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparative evaluation of accuracy, precision, and radiation dose between mindways and low-dose iCare QCT for lumbar spine BMD using the European spine phantom"],"prefix":"10.3389","volume":"7","author":[{"given":"Yujie","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiantian","family":"Yin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiushi","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heli","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zeguo","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanjiang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,5,12]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"9465","DOI":"10.3390\/ijms23169465","article-title":"Current status of the diagnosis and management of osteoporosis","volume":"23","author":"Aibar-Almaz\u00e1n","year":"2022","journal-title":"Int J Mol Sci"},{"key":"B2","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/j.mcna.2020.06.004","article-title":"Osteoporosis in older adults","volume":"104","author":"Johnston","year":"2020","journal-title":"Med Clin North Am"},{"key":"B3","doi-asserted-by":"publisher","first-page":"e2121106","DOI":"10.1001\/jamanetworkopen.2021.21106","article-title":"Prevalence of osteoporosis and fracture in China: the China osteoporosis prevalence study","volume":"4","author":"Wang","year":"2021","journal-title":"JAMA Netw Open"},{"key":"B4","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1016\/s0140-6736(18)32112-3","article-title":"Osteoporosis","volume":"393","author":"Compston","year":"2019","journal-title":"Lancet"},{"key":"B5","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1186\/s13018-023-04174-w","article-title":"Performance of iCare quantitative computed tomography in bone mineral density assessment of the hip and vertebral bodies in European spine phantom","volume":"18","author":"Liu","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"B6","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1007\/s11657-022-01061-5","article-title":"UK clinical guideline for the prevention and treatment of osteoporosis","volume":"17","author":"Gregson","year":"2022","journal-title":"Arch Osteoporos"},{"key":"B7","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1186\/s13018-021-02772-0","article-title":"The global prevalence of osteoporosis in the world: a comprehensive systematic review and meta-analysis","volume":"16","author":"Salari","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"B8","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1016\/S2213-8587(20)30159-5","article-title":"Treatment-related changes in bone mineral density as a surrogate biomarker for fracture risk reduction: meta-regression analyses of individual patient data from multiple randomised controlled trials","volume":"8","author":"Black","year":"2020","journal-title":"Lancet Diabetes Endocrinol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/s11926-020-00892-w","article-title":"Update on imaging-based measurement of bone mineral density and quality","volume":"22","author":"Link","year":"2020","journal-title":"Curr Rheumatol Rep"},{"key":"B10","doi-asserted-by":"publisher","first-page":"3875","DOI":"10.1007\/s00586-023-07917-9","article-title":"The correlation between osteoporotic vertebrae fracture risk and bone mineral density measured by quantitative computed tomography and dual energy x-ray absorptiometry: a systematic review and meta-analysis","volume":"32","author":"Chen","year":"2023","journal-title":"Eur Spine J"},{"key":"B11","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1111\/ejh.13847","article-title":"The role of opportunistic quantitative computed tomography in the evaluation of bone disease and risk of fracture in thalassemia major","volume":"109","author":"Carnevale","year":"2022","journal-title":"Eur J Haematol"},{"key":"B12","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1016\/j.jocd.2019.05.005","article-title":"Quantitative computed tomography (QCT) of the distal forearm in men using a spiral whole-body CT scanner\u2013description of a method and reliability assessment of the QCT pro software","volume":"23","author":"Hanusch","year":"2020","journal-title":"J Clin Densitom"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1007\/s00198-008-0820-y","article-title":"Comparison of QCT-derived and DXA-derived areal bone mineral density and T scores","volume":"20","author":"Khoo","year":"2009","journal-title":"Osteoporos Int"},{"key":"B14","doi-asserted-by":"publisher","first-page":"e23131","DOI":"10.7759\/cureus.23131","article-title":"Comparison of quantitative computed tomography and dual x-ray absorptiometry: osteoporosis detection rates in diabetic patients","volume":"14","author":"Dheeraj","year":"2022","journal-title":"Cureus"},{"key":"B15","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1016\/j.jocd.2021.01.002","article-title":"Structural factors associated with femoral neck fractures and its prediction in Chinese males","volume":"24","author":"Khoo","year":"2021","journal-title":"J Clin Densitom"},{"key":"B16","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.jocd.2021.02.004","article-title":"Accuracy, linearity and precision of spine QCT vBMD phantom measurements for different brands of CT scanner: a multicentre study","volume":"25","author":"Zhao","year":"2022","journal-title":"J Clin Densitom"},{"key":"B17","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1186\/s12880-023-01115-1","article-title":"Feasibility analysis of low-dose CT with asynchronous quantitative computed tomography to assess vBMD","volume":"23","author":"Hu","year":"2023","journal-title":"BMC Med Imaging"},{"key":"B18","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.jocd.2019.02.005","article-title":"Liquid calibration phantoms in ultra-low-dose QCT for the assessment of bone mineral density","volume":"23","author":"Malekzadeh","year":"2020","journal-title":"J Clin Densitom"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1016\/j.acra.2023.08.030","article-title":"Combining deep learning and radiomics for automated, objective, comprehensive bone mineral density assessment from low-dose chest computed tomography","volume":"31","author":"Wang","year":"2024","journal-title":"Acad Radiol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"4914","DOI":"10.21037\/qims-22-72","article-title":"Effect of abdominal adipose content on spine phantom bone mineral density measured by rapid kilovoltage-switching dual-energy CT and quantitative CT","volume":"12","author":"Ye","year":"2022","journal-title":"Quant Imaging Med Surg"},{"key":"B21","doi-asserted-by":"publisher","first-page":"320.e9","DOI":"10.1016\/j.crad.2019.11.008","article-title":"The accuracy of bone mineral density measurement using dual-energy spectral CT and quantitative CT: a comparative phantom study","volume":"75","author":"Li","year":"2020","journal-title":"Clin Radiol"},{"key":"B22","doi-asserted-by":"publisher","first-page":"2278","DOI":"10.21037\/qims-22-575","article-title":"Quantitative assessment of zonal trabecular volumetric bone mineral density in middle-aged and elderly women using quantitative computed tomography","volume":"13","author":"Yang","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"B23","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/0720-048x(95)00631-y","article-title":"The European spine phantom\u2013a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT","volume":"20","author":"Kalender","year":"1995","journal-title":"Eur J Radiol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"e79","DOI":"10.1016\/j.crad.2012.10.007","article-title":"Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study","volume":"68","author":"Schindera","year":"2013","journal-title":"Clin Radiol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"352","DOI":"10.21037\/qims-23-855","article-title":"Opportunistic screening for osteoporosis using enhanced images based on dual-energy computed tomography material decomposition: a comparison with quantitative computed tomography","volume":"14","author":"Tong","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.21037\/qims.2019.06.16","article-title":"The study protocol for the China health big data (China biobank) project","volume":"9","author":"Wu","year":"2019","journal-title":"Quant Imaging Med Surg"},{"key":"B27","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1007\/s00223-024-01303-3","article-title":"Long-term reproducibility of BMD-measurements with clinical QCT using simultaneous and asynchronous calibration methods and different measurement and reconstruction protocols","volume":"115","author":"du Mont","year":"2024","journal-title":"Calcif Tissue Int"},{"key":"B28","doi-asserted-by":"publisher","first-page":"2707","DOI":"10.1007\/s00330-010-1845-0","article-title":"Radiation exposure in x-ray-based imaging techniques used in osteoporosis","volume":"20","author":"Damilakis","year":"2010","journal-title":"Eur Radiol"},{"key":"B29","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1007\/s00198-013-2544-x","article-title":"A low-radiation exposure protocol for 3D QCT of the spine","volume":"25","author":"Museyko","year":"2014","journal-title":"Osteoporos Int"},{"key":"B30","doi-asserted-by":"publisher","first-page":"60","DOI":"10.21037\/qims.2018.01.05","article-title":"Quantitative imaging techniques for the assessment of osteoporosis and sarcopenia","volume":"8","author":"Guerri","year":"2018","journal-title":"Quant Imaging Med Surg"},{"key":"B31","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.spinee.2022.10.014","article-title":"Discordance in lumbar bone mineral density measurements by quantitative computed tomography and dual-energy x-ray absorptiometry in postmenopausal women: a prospective comparative study","volume":"23","author":"Lin","year":"2023","journal-title":"Spine J"},{"key":"B32","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s00402-023-05070-y","article-title":"Quantitative computed tomography has higher sensitivity detecting critical bone mineral density compared to dual-energy x-ray absorptiometry in postmenopausal women and elderly men with osteoporotic fractures: a real-life study","volume":"144","author":"Boehm","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"B33","doi-asserted-by":"publisher","first-page":"6887","DOI":"10.2147\/IJGM.S381857","article-title":"Application of dual-energy spectral computed tomography in bone mineral density measurement: phantom and clinical research","volume":"15","author":"Wang","year":"2022","journal-title":"Int J Gen Med"}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2025.1575553\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T04:43:15Z","timestamp":1747111395000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2025.1575553\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,12]]},"references-count":33,"alternative-id":["10.3389\/fmedt.2025.1575553"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2025.1575553","relation":{},"ISSN":["2673-3129"],"issn-type":[{"value":"2673-3129","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,12]]},"article-number":"1575553"}}