{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T05:47:09Z","timestamp":1758088029593,"version":"3.44.0"},"reference-count":31,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T00:00:00Z","timestamp":1757980800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>The primary objective of this study was to evaluate the efficiency and ergonomic benefits of a novel surgical lighting system developed within the <jats:italic>SmartOT<\/jats:italic> project. The developed system aims to automatically prevent shadows on the surgical field, eliminating the need for frequent manual adjustments, which is common with conventional surgical lights. Additionally, the study seeks to explore the feasibility of using EEG recordings as an objective method for assessing workplace strain in clinical settings, thereby laying the groundwork for future studies focused on reducing the workload of medical personnel.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>To achieve these objectives, we conducted a passive Oddball experiment involving EEG measurements to assess the impact of the new lighting system on workplace strain. Participants performed a task requiring them to identify specific LEGO\u00ae pieces. The study involved 30 participants (13 females, 17 males), with errors being tracked as an additional measure of cognitive load. The experimental setup was informed by previous research, which established a method for objectively determining workload generated by AR and VR technologies in clinical settings. In that research, EEG signals were recorded during surgical planning under different conditions, revealing trends in cognitive load and validating the utility of EEG for workload assessment.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The NASA Task Load Index (NASA-TLX) analysis revealed significantly lower mental demand, temporal demand, effort, and frustration scores for the smart surgical lamp compared to the manual lamp conditions, with mandatory and optional adjustments. However, there were no significant differences between the smart and conventional lamp in the dimensions of physical demand and performance. Similarly, EEG recordings indicated a higher P300 amplitude at electrode Fz following the smart lamp condition (<jats:italic>p<\/jats:italic>\u2009=\u20090.037), reflecting less cognitive load; latencies did not differ between conditions. Error analysis confirmed fewer errors and shorter processing times for the smart lamp.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The measurements of NASA-TLX and EEG after running simulated surgical tasks showed that the <jats:italic>SmartOT<\/jats:italic> prototype significantly reduced errors and workload compared to the conventional surgical lamp. These findings reflect the capability of smart surgical lighting in improving patient safety and efficiency within operating theaters.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fmedt.2025.1584606","type":"journal-article","created":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T04:14:04Z","timestamp":1757996044000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluating the efficiency and ergonomics of a novel smart surgical lighting system: a passive oddball experiment with EEG measurements to assess workplace strain in clinical settings"],"prefix":"10.3389","volume":"7","author":[{"given":"Tim","family":"Schneider","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk","family":"Weyhe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Merle","family":"Schlender","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timur","family":"Cetin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Navid","family":"Tabriz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Verena","family":"Uslar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2025,9,16]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e87","DOI":"10.1055\/s-0040-1710529","article-title":"Current state of surgical lighting","volume":"6","author":"Curlin","year":"2020","journal-title":"Surg J"},{"key":"B2","doi-asserted-by":"publisher","first-page":"267","DOI":"10.3109\/13645706.2010.534169","article-title":"Indicating shortcomings in surgical lighting systems","volume":"20","author":"Knulst","year":"2011","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"421","DOI":"10.3944\/AOTT.2015.14.0401","article-title":"Surgical light handles: a source of contamination in the surgical field","volume":"49","author":"Schweitzer","year":"2015","journal-title":"ACTA Orthop Traumatol Turc"},{"key":"B4","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1016\/j.surge.2023.05.004","article-title":"A timeline of surgical lighting\u2014is automated lighting the future?","volume":"21","author":"Sharma","year":"2023","journal-title":"Surgeon"},{"key":"B5","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1007\/978-981-16-6775-6_24","article-title":"Optimizing the illumination of a surgical site in new autonomous module-based surgical lighting systems","volume-title":"Medical Imaging and Computer-Aided Diagnosis","author":"M\u00fchlenbrock","year":"2023"},{"key":"B6","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.surg.2009.10.007","article-title":"The impact of stress on surgical performance: a systematic review of the literature","volume":"147","author":"Arora","year":"2010","journal-title":"Surgery"},{"key":"B7","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1002\/bjs.10795","article-title":"Systematic review of measurement tools to assess surgeons\u2019 intraoperative cognitive workload","volume":"105","author":"Dias","year":"2018","journal-title":"Br J Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"611962","DOI":"10.3389\/fnins.2021.611962","article-title":"Adaptive filtering for improved EEG-based mental workload assessment of ambulant users","volume":"15","author":"Rosanne","year":"2021","journal-title":"Front Neurosci"},{"key":"B9","doi-asserted-by":"publisher","first-page":"e62740","DOI":"10.2196\/62740","article-title":"Measuring bound attention during Complex liver surgery planning: feasibility study","volume":"9","author":"Schneider","year":"2025","journal-title":"JMIR Form Res"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1145\/3696670","article-title":"A novel, autonomous, module-based surgical lighting system","volume":"6","author":"M\u00fchlenbrock","year":"2025","journal-title":"ACM Trans Comput Healthc"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1055053","DOI":"10.3389\/fsurg.2023.1055053","article-title":"A virtual reality simulation of a novel way to illuminate the surgical field\u2014a feasibility study on the use of automated lighting systems in the operating theatre","volume":"10","author":"Cetin","year":"2023","journal-title":"Front Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"e0287885","DOI":"10.1371\/journal.pone.0287885","article-title":"Dry EEG measurement of P3 to evaluate cognitive load during sitting, standing, and walking","volume":"18","author":"Swerdloff","year":"2023","journal-title":"PLoS One"},{"key":"B13","doi-asserted-by":"publisher","first-page":"5230","DOI":"10.1016\/j.promfg.2015.07.594","article-title":"EEG\/ERP as a measure of mental workload in a simple piloting task","volume":"3","author":"Causse","year":"2015","journal-title":"Procedia Manuf"},{"key":"B14","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1177\/154193120605000909","article-title":"Nasa-task load index (NASA-TLX); 20 years later","volume":"50","author":"Hart","year":"2006","journal-title":"Proc Hum Factors Ergon Soc Annu Meet"},{"key":"B15","first-page":"139","article-title":"Development of NASA-TLX (task load index): results of empirical and theoretical research","volume-title":"Advances in Psychology","author":"Hart","year":"1988"},{"key":"B16","doi-asserted-by":"publisher","first-page":"101424","DOI":"10.1016\/j.ienj.2024.101424","article-title":"Quantifying emergency department nursing workload at the task level using NASA-TLX: an exploratory descriptive study","volume":"74","author":"Park","year":"2024","journal-title":"Int Emerg Nurs"},{"key":"B17","doi-asserted-by":"publisher","first-page":"683388","DOI":"10.3389\/fpubh.2021.683388","article-title":"Mental workload and job satisfaction in healthcare workers: the moderating role of job control","volume":"9","author":"Rostami","year":"2021","journal-title":"Front Public Health"},{"key":"B18","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1016\/j.ijmedinf.2015.03.003","article-title":"Cognitive workload changes for nurses transitioning from a legacy system with paper documentation to a commercial electronic health record","volume":"84","author":"Colligan","year":"2015","journal-title":"Int J Med Inf"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1401005","DOI":"10.3389\/fpsyg.2024.1401005","article-title":"Which ERP components are effective in measuring cognitive load in multimedia learning? A meta-analysis based on relevant studies","volume":"15","author":"Yu","year":"2024","journal-title":"Front Psychol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"e2269","DOI":"10.1002\/brb3.2269","article-title":"Using electrophysiological measures to evaluate the sense of presence in immersive virtual environments: an event-related potential study","volume":"11","author":"Grassini","year":"2021","journal-title":"Brain Behav"},{"key":"B21","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1518\/001872008X288394","article-title":"Multiple resources and mental workload","volume":"50","author":"Wickens","year":"2008","journal-title":"Hum Factors"},{"key":"B22","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.biopsycho.2014.07.014","article-title":"Effects of mental workload and fatigue on the P300, alpha and theta band power during operation of an ERP (P300) brain\u2013computer interface","volume":"102","author":"K\u00e4thner","year":"2014","journal-title":"Biol Psychol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"57","DOI":"10.3389\/fnhum.2019.00057","article-title":"A review of psychophysiological measures to assess cognitive states in real-world driving","volume":"13","author":"Lohani","year":"2019","journal-title":"Front Hum Neurosci"},{"key":"B24","doi-asserted-by":"publisher","first-page":"2128","DOI":"10.1016\/j.clinph.2007.04.019","article-title":"Updating P300: an integrative theory of P3a and P3b","volume":"118","author":"Polich","year":"2007","journal-title":"Clin Neurophysiol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.biopsycho.2007.10.014","article-title":"Workload assessment of computer gaming using a single-stimulus event-related potential paradigm","volume":"77","author":"Allison","year":"2008","journal-title":"Biol Psychol"},{"key":"B26","first-page":"1067","article-title":"Neural correlates of simulated driving: auditory oddball responses dependent on workload","volume-title":"Foundations of Augmented Cognition","author":"Raabe","year":"2005"},{"key":"B27","doi-asserted-by":"publisher","first-page":"771533","DOI":"10.3389\/fnins.2021.771533","article-title":"Working with environmental noise and noise-cancelation: a workload assessment with EEG and subjective measures","volume":"15","author":"Pieper","year":"2021","journal-title":"Front Neurosci"},{"key":"B28","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1007\/978-3-319-94866-9_2","article-title":"Use of dry electrode electroencephalography (EEG) to monitor pilot workload and distraction based on P300 responses to an auditory oddball task","volume-title":"Advances in Neuroergonomics and Cognitive Engineering","author":"Gibson","year":"2019"},{"key":"B29","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1136\/bmjqs-2017-007333","article-title":"Task errors by emergency physicians are associated with interruptions, multitasking, fatigue and working memory capacity: a prospective, direct observation study","volume":"27","author":"Westbrook","year":"2018","journal-title":"BMJ Qual Saf"},{"key":"B30","doi-asserted-by":"publisher","first-page":"7172","DOI":"10.3390\/s24227172","article-title":"Investigation of possible sources of electrodermal activity in surgical personnel to assess workplace stress levels","volume":"24","author":"Schlender","year":"2024","journal-title":"Sensors"},{"key":"B31","doi-asserted-by":"publisher","first-page":"729197","DOI":"10.3389\/fnrgo.2021.729197","article-title":"Measuring correlates of mental workload during simulated driving using cEEGrid electrodes: a test\u2013retest reliability analysis","volume":"2","author":"Getzmann","year":"2021","journal-title":"Front Neuroergonomics"}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2025.1584606\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T04:14:06Z","timestamp":1757996046000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2025.1584606\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,16]]},"references-count":31,"alternative-id":["10.3389\/fmedt.2025.1584606"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2025.1584606","relation":{},"ISSN":["2673-3129"],"issn-type":[{"type":"electronic","value":"2673-3129"}],"subject":[],"published":{"date-parts":[[2025,9,16]]},"article-number":"1584606"}}