{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T06:20:25Z","timestamp":1783405225461,"version":"3.54.6"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:00:00Z","timestamp":1783382400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to conduct a training-phase evaluation of a novel continuous automated non-invasive sphygmomanometer, oCare\u2122 BP100, in intensive care unit (ICU) Taiwanese patients according to ISO 81060-3:2022 in Type T mode. The evaluation included stability testing and blood pressure change tracking.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of forty ICU patients were recruited from the National Taiwan University Hospital Hsin-Chu Branch. All enrolled patients had undergone unilateral radial artery catheterization in the forearm as part of routine clinical care. The catheter was connected to Philips patient monitors (Models: IntelliVue MX800 and X2) to obtain invasive blood pressure measurements for calibration purposes. Each subject underwent simultaneous monitoring with oCare\u2122 BP100 sensors placed on the fingers of both hands. Paired measurements of the same side were further processed and followed ISO 81060-3:2022, for the defined Type T blood pressure monitor, the well-established stability method and the blood pressure change method were implemented and analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The present study belongs to the training phase and therefore the study was not carried out completely according to the ISO 81060-3:2022 protocol, e.g., the distribution of gender and the eligible subject in BP change test not fulfilled. For all 6 analysis periods, for the corrected standard deviations of SBP, DBP, and MAP parameter defined ISO target thresholds (A) s\n                      <jats:sub>corr<\/jats:sub>\n                      \u2009\u2264\u20096\u2005mmHg for each analysis period. In the Blood Pressure Change Test, at most 22 subjects the minimum requirement of 50 change points per subject, the for the change requirements were (B1)\n                      <jats:inline-formula>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM1\">\n                          <mml:msub>\n                            <mml:mrow>\n                              <mml:mover>\n                                <mml:mi>E<\/mml:mi>\n                                <mml:mo stretchy=\"false\">\u00af<\/mml:mo>\n                              <\/mml:mover>\n                            <\/mml:mrow>\n                            <mml:mrow>\n                              <mml:mn>50<\/mml:mn>\n                              <mml:mi>t<\/mml:mi>\n                              <mml:mi>h<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                          <mml:mo>\u2264<\/mml:mo>\n                          <mml:mn>25<\/mml:mn>\n                          <mml:mtext>%<\/mml:mtext>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                      and (B2)\n                      <jats:inline-formula>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"IM2\">\n                          <mml:msub>\n                            <mml:mrow>\n                              <mml:mover>\n                                <mml:mi>E<\/mml:mi>\n                                <mml:mo stretchy=\"false\">\u00af<\/mml:mo>\n                              <\/mml:mover>\n                            <\/mml:mrow>\n                            <mml:mrow>\n                              <mml:mn>85<\/mml:mn>\n                              <mml:mi>t<\/mml:mi>\n                              <mml:mi>h<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                          <mml:mo>\u2264<\/mml:mo>\n                          <mml:mn>50<\/mml:mn>\n                          <mml:mtext>%<\/mml:mtext>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                      error for blood pressure.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The present study demonstrated that a training-phase evaluation of Type T mode continuous automated non-invasive sphygmomanometer repeated SBP, DBP, and MAP measurement of oCare\u2122 BP100 in Type T mode are stable across various analysis periods and patients. oCare\u2122 BP100 in Type T Mode can track blood pressure changes in ICU patients during different activities. Even with the absence of females in the sex ratio and an insufficient number of participants in the blood pressure change test, the exploratory study still showed training-phase results that were within ISO target thresholds, full ISO validation remains to be completed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmedt.2026.1681323","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T05:45:09Z","timestamp":1783403109000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Continuous BP monitoring of ICU Taiwanese patients: training-phase evaluation of oCare\u2122 BP100 according to ISO 81060-3: 2022"],"prefix":"10.3389","volume":"8","author":[{"given":"Chao-Lun","family":"Lai","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch","place":["Hsin-Chu, Taiwan"]},{"name":"Department of Internal Medicine, College of Medicine, National Taiwan University","place":["Taipei, Taiwan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeh-Wen","family":"Lee","sequence":"additional","affiliation":[{"name":"Taiwan Biophotonic Corporation (tBPC)","place":["Zhubei, Hsinchu County, Taiwan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chia-Fang","family":"Chang","sequence":"additional","affiliation":[{"name":"Taiwan Biophotonic Corporation (tBPC)","place":["Zhubei, Hsinchu County, Taiwan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang-Sheng","family":"Chu","sequence":"additional","affiliation":[{"name":"Taiwan Biophotonic Corporation (tBPC)","place":["Zhubei, Hsinchu County, Taiwan"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1849","DOI":"10.1001\/jama.2022.19590","article-title":"Treatment of hypertension: a review","volume":"328","author":"Carey","year":"2022","journal-title":"JAMA"},{"key":"B2","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1038\/s41569-022-00690-0","article-title":"Blood pressure and its variability: classic and novel measurement techniques","volume":"19","author":"Schutte","year":"2022","journal-title":"Nat Rev Cardiol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1089\/tmj.2017.0068","article-title":"A literature review on current and proposed technologies of noninvasive blood pressure measurement","volume":"24","author":"Mukherjee","year":"2018","journal-title":"Telemed J E Health"},{"key":"B4","doi-asserted-by":"publisher","first-page":"2133","DOI":"10.3390\/ma16062133","article-title":"Wearable continuous blood pressure monitoring devices based on pulse wave transit time and pulse arrival time: a review","volume":"16","author":"Zhou","year":"2023","journal-title":". Materials (Basel)"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1827","DOI":"10.3390\/jcm8111827","article-title":"Multi-site photoplethysmography technology for blood pressure assessment: challenges and recommendations","volume":"8","author":"Chan","year":"2019","journal-title":"J Clin Med"},{"key":"B6","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/MBP.0b013e3283360e98","article-title":"Working group on blood pressure monitoring of the European society of hypertension. European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults","volume":"15","author":"O\u2019Brien","year":"2010","journal-title":"Blood Press Monit"},{"key":"B7","volume-title":"ISO 81060\u20132:2013 Non-invasive sphygmomanometers\u2014part 2: Clinical Investigation of Automated Measurement Type","year":"2013"},{"key":"B8","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1007\/s10439-011-0467-2","article-title":"Continuous and noninvasive measurement of systolic and diastolic blood pressure by one mathematical model with the same model parameters and two separate pulse wave velocities","volume":"40","author":"Chen","year":"2012","journal-title":"Ann Biomed Eng"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1514","DOI":"10.1109\/TBME.2018.2874957","article-title":"Multi-wavelength photoplethysmography enabling continuous blood pressure measurement with compact wearable electronics","volume":"66","author":"Liu","year":"2019","journal-title":"IEEE Trans Biomed Eng"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1464473","DOI":"10.3389\/fmedt.2024.1464473","article-title":"A prototype photoplethysmography-based cuffless device shows promising results in tracking changes in blood pressure","volume":"6","author":"Hove","year":"2024","journal-title":"Front Med Technol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"111763","DOI":"10.1016\/j.jclinane.2025.111763","article-title":"Comparison of continuous non-invasive blood pressure measurement using vitalstream\u2122 to invasive intraarterial pressure in pediatric surgery","volume":"102","author":"Boretsky","year":"2025","journal-title":"J Clin Anesth"},{"key":"B12","year":""},{"key":"B13","year":""},{"key":"B14","doi-asserted-by":"publisher","first-page":"A485","DOI":"10.1093\/sleep\/zsae067.01131","article-title":"1131: a novel sensor to track transient blood pressure changes during sleep","volume":"47","author":"Khayat","year":"2024","journal-title":"Sleep"}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2026.1681323\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T05:45:10Z","timestamp":1783403110000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2026.1681323\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,7]]},"references-count":14,"alternative-id":["10.3389\/fmedt.2026.1681323"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2026.1681323","relation":{},"ISSN":["2673-3129"],"issn-type":[{"value":"2673-3129","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,7]]},"article-number":"1681323"}}