{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:03:36Z","timestamp":1781071416152,"version":"3.54.1"},"reference-count":43,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T00:00:00Z","timestamp":1781049600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Hyperthermia has emerged as a versatile modality in oncology, rehabilitation, and aesthetic medicine, yet conventional RF devices often suffer from insufficient penetration and collateral epidermal heating. This study proposes a miniaturized stacked cavity-backed antenna operating in the 2.4-2.5 GHz ISM band for depth-confined heating of facial subcutaneous fat.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>By leveraging the strong dielectric contrast at the skin-fat boundary, the design enhances the normal electric-field component in adipose tissue to promote preferential power deposition without active epidermal cooling. Electromagnetic simulations quantify field and SAR confinement, and multiphysics thermal simulations evaluate short-pulse therapeutic operation. The methodology is validated through ex vivo porcine experiments and a preliminary in vivo human feasibility test (10 W, surface thermography).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The results confirm reproducible superficial warming at the target depth without adverse skin reactions. The study successfully demonstrates single-element hardware feasibility and effective depth-selective energy confinement within the subcutaneous fat layer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This research establishes the fundamental hardware capability for targeted facial hyperthermia. However, macroscopic treatment-uniformity protocols and long-term clinical efficacy remain topics for future clinical studies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmedt.2026.1768771","type":"journal-article","created":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T05:37:52Z","timestamp":1781069872000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A stacked cavity-backed metamaterial antenna for confined hyperthermia of subcutaneous fat in ISM band"],"prefix":"10.3389","volume":"8","author":[{"given":"Dong-Min","family":"Lee","sequence":"first","affiliation":[{"name":"RFIC Bio Center, Kwangwoon University","place":["Seoul, Republic of Korea"]},{"name":"Department Electronic Engineering, Kwangwoon University","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun-Jae","family":"Jung","sequence":"additional","affiliation":[{"name":"RFIC Bio Center, Kwangwoon University","place":["Seoul, Republic of Korea"]},{"name":"Department Electronic Engineering, Kwangwoon University","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ikhwan","family":"Kim","sequence":"additional","affiliation":[{"name":"RFIC Bio Center, Kwangwoon University","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyujin","family":"Cho","sequence":"additional","affiliation":[{"name":"RFIC Bio Center, Kwangwoon University","place":["Seoul, Republic of Korea"]},{"name":"Department Electronic Engineering, Kwangwoon University","place":["Seoul, Republic of Korea"]},{"name":"R&D Center, APR Co., Ltd.","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingzhou","family":"Wang","sequence":"additional","affiliation":[{"name":"RFIC Bio Center, Kwangwoon University","place":["Seoul, Republic of Korea"]},{"name":"Department Electronic Engineering, Kwangwoon University","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seongwoog","family":"Oh","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, University of Seoul","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eun-Seong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Molecular Medicine and Biopharmaceutical Sciences, Seoul National University","place":["Seoul, Republic of Korea"]},{"name":"Department of Medical and Digital Engineering, College of Engineering, Hanyang University","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nam-Young","family":"Kim","sequence":"additional","affiliation":[{"name":"RFIC Bio Center, Kwangwoon University","place":["Seoul, Republic of Korea"]},{"name":"Department Electronic Engineering, Kwangwoon University","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,6,10]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"3557","DOI":"10.1002\/mp.17836","article-title":"Optimization of microwave hyperthermia system for focused breast cancer treatment: a study using realistic digital breast phantoms","volume":"52","author":"Acar","year":"2025","journal-title":"Med Phys"},{"key":"B2","doi-asserted-by":"publisher","first-page":"6592","DOI":"10.3390\/s23146592","article-title":"Comparison of microwave hyperthermia applicator designs with fora dipole and connected array","volume":"23","author":"Yildiz","year":"2023","journal-title":"Sensors"},{"key":"B3","doi-asserted-by":"publisher","first-page":"155","DOI":"10.3390\/cancers9110155","article-title":"Current and prospective protein biomarkers of lung cancer","volume":"9","author":"Zamay","year":"2017","journal-title":"Cancers (Basel)"},{"key":"B4","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1080\/0265673031000119006","article-title":"Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia","volume":"19","author":"Dewhirst","year":"2003","journal-title":"Int J Hyperthermia"},{"key":"B5","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1109\/JERM.2021.3066103","article-title":"Efficacy of a lung-tuned monopole antenna for microwave ablation: analytical solution and validation in a ventilator-controlled ex vivo porcine lung model","volume":"5","author":"Chiang","year":"2021","journal-title":"IEEE J Electromagn RF Microw Med Biol"},{"key":"B6","doi-asserted-by":"publisher","first-page":"10662","DOI":"10.1021\/acsomega.9b01030","article-title":"Radiofrequency hyperthermia of cancer cells enhanced by silicic acid ions released during the biodegradation of porous silicon nanowires","volume":"4","author":"Gongalsky","year":"2019","journal-title":"ACS Omega"},{"key":"B7","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.biomaterials.2018.01.024","article-title":"Bacteria-responsive intelligent wound dressing: simultaneous in situ detection and inhibition of bacterial infection for accelerated wound healing","volume":"161","author":"Zhou","year":"2018","journal-title":"Biomaterials"},{"key":"B8","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.biomaterials.2017.10.034","article-title":"Mitochondrial specific photodynamic therapy by rare-earth nanoparticles mediated near-infrared graphene quantum dots","volume":"153","author":"Zhang","year":"2018","journal-title":"Biomaterials"},{"key":"B9","doi-asserted-by":"publisher","first-page":"119456","DOI":"10.1016\/j.biomaterials.2019.119456","article-title":"Chiral geometry regulates stem cell fate and activity","volume":"222","author":"Dong","year":"2019","journal-title":"Biomaterials"},{"key":"B10","doi-asserted-by":"publisher","first-page":"47","DOI":"10.2147\/CCID.S69118","article-title":"Noninvasive skin tightening: focus on new ultrasound techniques","volume":"8","author":"Guillen Fabi","year":"2015","journal-title":"Clin Cosmet Investig Dermatol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1055\/s-0033-1363756","article-title":"Skin tightening technologies","volume":"30","author":"Greene","year":"2014","journal-title":"Facial Plast Surg"},{"key":"B12","first-page":"9","article-title":"Noninvasive radio frequency for skin tightening and body contouring","volume":"32","author":"Weiss","year":"2013","journal-title":"Semin Cutaneous Med Surg"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.3390\/v15071443","article-title":"SARS-CoV-2 inactivation in aerosol by means of radiated microwaves","volume":"15","author":"Manna","year":"2023","journal-title":"Viruses"},{"key":"B14","doi-asserted-by":"publisher","first-page":"S39","DOI":"10.1016\/j.descs.2006.08.006","article-title":"Efficacy of thermal stimulation on wrinkle removal via the enhancement of collagen synthesis","volume":"2","author":"Yamamoto","year":"2006","journal-title":"J Derm Sci Suppl"},{"key":"B15","first-page":"24","article-title":"Body contouring and skin tightening using a unique novel multisource radiofrequency energy delivery method","volume":"10","author":"Rousseaux","year":"2017","journal-title":"J Clin Aesthet Dermatol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1007\/s00266-011-9783-z","article-title":"Treatment of overweight patients by radiofrequency-assisted liposuction (RFAL) for aesthetic reshaping and skin tightening","volume":"36","author":"Hurwitz","year":"2012","journal-title":"Aesthetic Plast Surg"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/9685476","article-title":"Role of simulations in the treatment planning of radiofrequency hyperthermia therapy in clinics","volume":"2019","author":"Prasad","year":"2019","journal-title":"J Oncol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1111\/ddg.13736","article-title":"The efficacy of micro-insulated needle radiofrequency system for the treatment of lower eyelid fat bulging","volume":"17","author":"Shin","year":"2019","journal-title":"J Dtsch Dermatol Ges"},{"key":"B19","first-page":"E58","article-title":"Skin tightening following multisource, phase-controlled radiofrequency treatments with novel unique concentric electrodes in Asian patients","volume":"12","author":"Tanaka","year":"2019","journal-title":"J Clin Aesthet Dermatol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1002\/lsm.20925","article-title":"Hyperthermic injury to adipocyte cells by selective heating of subcutaneous fat with a novel radiofrequency device: feasibility studies","volume":"42","author":"Franco","year":"2010","journal-title":"Lasers Surg Med"},{"key":"B21","doi-asserted-by":"publisher","first-page":"63715","DOI":"10.1109\/ACCESS.2022.3183223","article-title":"Dual-band on-body near field antenna for measuring deep core temperature with a microwave radiometer","volume":"10","author":"Kim","year":"2022","journal-title":"IEEE Access"},{"key":"B22","doi-asserted-by":"publisher","first-page":"32944","DOI":"10.1109\/ACCESS.2023.3262997","article-title":"Compact dual-band on-body near field antenna with reflector for measuring deep core temperature","volume":"11","author":"Kim","year":"2023","journal-title":"IEEE Access"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1378084","DOI":"10.3389\/fbioe.2024.1378084","article-title":"Radio frequency hyperthermia system for skin tightening effect by filled waveguide aperture antenna with compact metamaterials","volume":"12","author":"Kim","year":"2024","journal-title":"Front Bioeng Biotechnol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"64","DOI":"10.25289\/ML.2019.8.2.64","article-title":"The effectiveness of 448-khz capacitive resistive monopolar radiofrequency for subcutaneous fat reduction in a porcine model","volume":"8","author":"Kwon","year":"2019","journal-title":"Med Lasers"},{"key":"B25","first-page":"1","article-title":"Circular antenna array design for breast cancer detection","author":"Ouerghi","year":"2017"},{"key":"B26","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1016\/j.medengphy.2010.12.011","article-title":"Analysis of signal propagation in an elastic-tube flow model","volume":"33","author":"Akman","year":"2011","journal-title":"Med Eng Phys"},{"key":"B27","doi-asserted-by":"publisher","first-page":"2010","DOI":"10.1109\/TAP.2016.2535498","article-title":"A low-profile high-gain and wideband filtering antenna with metasurface","volume":"64","author":"Pan","year":"2016","journal-title":"IEEE Trans Antennas Propag"},{"key":"B28","doi-asserted-by":"publisher","first-page":"93338","DOI":"10.1109\/ACCESS.2022.3203431","article-title":"Design of multiresonance flexible antenna array applicator for breast cancer hyperthermia treatment","volume":"10","author":"Mahmoud","year":"2022","journal-title":"IEEE Access"},{"key":"B29","doi-asserted-by":"publisher","first-page":"737","DOI":"10.3109\/02656736.2015.1068957","article-title":"Design and characterisation of miniaturised cavity-backed patch antenna for microwave hyperthermia","volume":"31","author":"Chakaravarthi","year":"2015","journal-title":"Int J Hyperthermia"},{"key":"B30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.11648\/j.ajea.20241301.11","article-title":"Design and optimization of a miniaturized antenna for targeted hyperthermia in tumor therapy","volume":"13","author":"Mishra","year":"2025","journal-title":"Am J Electromagn Appl"},{"key":"B31","doi-asserted-by":"publisher","first-page":"1952","DOI":"10.1109\/TAP.2019.2891220","article-title":"A new method for achieving miniaturization and gain enhancement of cicaldi antenna array based on anisotropic metasurface","volume":"67","author":"Zhu","year":"2019","journal-title":"IEEE Trans Antennas Propag"},{"key":"B32","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1109\/MAP.2013.6735515","article-title":"Extraction of material parameters for metamaterials using a full-wave simulator [education column]","volume":"55","author":"Numan","year":"2013","journal-title":"IEEE Antennas Propag Mag"},{"key":"B33","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1002\/bem.22081","article-title":"Wearable slot antenna at 2.45\u2005GHz for off-body radiation: analysis of efficiency, frequency shift, and body absorption","volume":"39","author":"Fernandez","year":"2018","journal-title":"Bioelectromagnetics"},{"key":"B34","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1080\/09205071.2023.2216394","article-title":"Compact conformal metasurface antenna for hyperthermia applications","volume":"37","author":"Singh","year":"2023","journal-title":"J Electromagn Waves Appl"},{"key":"B35","doi-asserted-by":"publisher","first-page":"5287","DOI":"10.1088\/0031-9155\/59\/18\/5287","article-title":"Development of a new generation of high-resolution anatomical models for medical device evaluation: the virtual population 3.0","volume":"59","author":"Gosselin","year":"2014","journal-title":"Phys Med Biol"},{"key":"B36","doi-asserted-by":"publisher","first-page":"5806753","DOI":"10.1155\/2018\/5806753","article-title":"Feasibility of using a novel 2.45\u2005GHz double short distance slot coaxial antenna for minimally invasive cancer breast microwave ablation therapy: computational model, phantom, and in vivo swine experimentation","volume":"2018","author":"Ortega-Palacios","year":"2018","journal-title":"J Healthc Eng"},{"key":"B37","doi-asserted-by":"publisher","first-page":"2411842","DOI":"10.1002\/adfm.202411842","article-title":"Microwave hyperthermia technology based on near-field focused metasurfaces: design and implementation","volume":"35","author":"Xiong","year":"2025","journal-title":"Adv Funct Mater"},{"key":"B38","doi-asserted-by":"publisher","first-page":"511","DOI":"10.3390\/electronics11040511","article-title":"Wireless electromagnetic radiation assessment based on the specific absorption rate (sar); A review case study","volume":"11","author":"Abdul-Al","year":"2022","journal-title":"Electronics (Basel)"},{"key":"B39","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1109\/LAWP.2013.2241722","article-title":"Dielectric properties of porcine skin tissue and in vivo testing of implantable antennas using pigs as model animals","volume":"11","author":"Karacolak","year":"2012","journal-title":"IEEE Antennas Wirel Propag Lett"},{"key":"B40","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1109\/LAWP.2022.3174872","article-title":"A minimally invasive microwave ablation antenna with highly localized ablation zone","volume":"21","author":"Wang","year":"2022","journal-title":"IEEE Antennas Wirel Propag Lett"},{"key":"B41","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1016\/j.asj.2005.09.017","article-title":"Thermage: monopolar radiofrequency","volume":"25","author":"Burns","year":"2005","journal-title":"Aesthetic Surg J"},{"key":"B42","author":"Hasgall","year":"2022"},{"key":"B43","first-page":"1","article-title":"IEEE Recommended practice for measurements and computations of electric, magnetic, and electromagnetic fields with respect to human exposure to such fields, 0\u2005Hz to 300\u2005GHz","year":"2021"}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2026.1768771\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T05:37:53Z","timestamp":1781069873000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2026.1768771\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,10]]},"references-count":43,"alternative-id":["10.3389\/fmedt.2026.1768771"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2026.1768771","relation":{},"ISSN":["2673-3129"],"issn-type":[{"value":"2673-3129","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,10]]},"article-number":"1768771"}}