{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T06:13:16Z","timestamp":1788415996977,"version":"build-2803163510"},"reference-count":63,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med. Technol."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Conventional ultrasound safety monitoring relies on the Mechanical Index (MI) and Thermal Index (TI), which lack tissue-specificity. Consequently, real-time safety profiling remains imprecise. Dynamic, tissue-specific corrections such as tissue perfusion rate (TPR) aim to address this limitation. This narrative review examines how integrating these corrections with quantum-cloud computational frameworks may enable enhanced safety and image quality in ultrasonic applications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>We assessed the potential of an integrated quantum-cloud framework to reduce ultrasound-related bioeffects without compromising image quality, compared to standard MI\/TI monitoring in patients undergoing clinical ultrasound imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A narrative synthesis of the eligible literature was performed, guided by thematic analysis frameworks. Quantitative outcomes were descriptively summarized with medians and ranges; formal meta-analysis was not conducted because heterogeneity in TPR measurement protocols, device manufacturers, and outcome definitions violated the commutability assumption required for statistical pooling.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Qualitative synthesis indicated that tissue-specific, multi-parameter correction strategies were consistently associated with more conservative acoustic exposure and heightened safety awareness than static MI\/TI monitoring alone, although the consistency and clinical magnitude of these benefits varied across anatomical applications and study designs. The certainty of the current evidence was judged low to moderate, limited by non-standardized TPR measurement protocols and heterogeneous outcome definitions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Together, these data suggest that multi-parameter acoustic correction coupled with cloud computing holds promise for improving ultrasound safety profiling and imaging precision. However, the current low-to-moderate certainty of evidence, due to methodological heterogeneity, necessitates future validation of edge-cloud synergies to realize robust, personalized monitoring systems.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmedt.2026.1775679","type":"journal-article","created":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T05:21:38Z","timestamp":1788412898000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Quantum-edge synergy for dynamic acoustic compensation in ultrasound safety: a narrative review of tissue heterogeneity challenges"],"prefix":"10.3389","volume":"8","author":[{"given":"Bin","family":"Hu","sequence":"first","affiliation":[{"name":"Medical Examination Center, Hubei Provincial Hospital of Integrated Chinese and Western Medicine","place":["Wuhan, Hubei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Shi","sequence":"additional","affiliation":[{"name":"Department of Nephrology, Xiangyang Hospital Affiliated to Hubei University of Chinese Medicine","place":["Xiangyang, Hubei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shihong","family":"Xiong","sequence":"additional","affiliation":[{"name":"Department of Nephrology, Tianyou Hospital Affiliated to Wuhan University of Science and Technology","place":["Wuhan, Hubei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Songlin","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Nephrology, Tianyou Hospital Affiliated to Wuhan University of Science and Technology","place":["Wuhan, Hubei, China"]},{"name":"School of Medicine, Wuhan University of Science and Technology","place":["Wuhan, Hubei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelun","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Nephrology, Tianyou Hospital Affiliated to Wuhan University of Science and Technology","place":["Wuhan, Hubei, China"]},{"name":"School of Medicine, Wuhan University of Science and Technology","place":["Wuhan, Hubei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Na","family":"Gong","sequence":"additional","affiliation":[{"name":"Medical Examination Center, Hubei Provincial Hospital of Integrated Chinese and Western Medicine","place":["Wuhan, Hubei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1002\/jum.15323","article-title":"Safety assessment of an A-scan ultrasonic system for ophthalmic use","volume":"39","author":"Petrella","year":"2020","journal-title":"J Ultrasound Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1817","DOI":"10.1007\/s11548-025-03489-9","article-title":"Real-time 3D US-CT fusion-based semi-automatic puncture robot system: clinical evaluation","volume":"20","author":"Nakayama","year":"2025","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/EMBC40787.2023.10341168","article-title":"Robust 3D breast reconstruction based on monocular images and artificial intelligence for robotic guided oncological interventions","author":"Duarte","year":"2023","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"B4","doi-asserted-by":"publisher","first-page":"8529","DOI":"10.1038\/s41467-024-52912-3","article-title":"Nonlocal photonic quantum gates over 7.0\u2005km","volume":"15","author":"Liu","year":"2024","journal-title":"Nat Commun"},{"key":"B5","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1016\/S2215-0366(23)00183-9","article-title":"Brain-based correlates of antidepressant response to ketamine: a comprehensive systematic review of neuroimaging studies","volume":"10","author":"Medeiros","year":"2023","journal-title":"Lancet Psychiatry"},{"key":"B6","doi-asserted-by":"publisher","first-page":"6679","DOI":"10.1109\/TCYB.2024.3420958","article-title":"Process manufacturing intelligence empowered by industrial metaverse: a survey","volume":"54","author":"Luo","year":"2024","journal-title":"IEEE Trans Cybern"},{"key":"B7","doi-asserted-by":"publisher","first-page":"101557","DOI":"10.1016\/j.nantod.2022.101557","article-title":"Fully implantable batteryless soft platforms with printed nanomaterial-based arterial stiffness sensors for wireless continuous monitoring of restenosis in real time","volume":"46","author":"Herbert","year":"2022","journal-title":"Nano Today"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1038\/s41592-024-02400-9","article-title":"Self-inspired learning for denoising live-cell super-resolution microscopy","volume":"21","author":"Qu","year":"2024","journal-title":"Nat Methods"},{"key":"B9","doi-asserted-by":"publisher","first-page":"115650","DOI":"10.1016\/j.bios.2023.115650","article-title":"Soft implantable printed bioelectronic system for wireless continuous monitoring of restenosis","volume":"241","author":"Rigo","year":"2023","journal-title":"Biosens Bioelectron"},{"key":"B10","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s40820-025-01890-2","article-title":"Wearable ultrasound devices for therapeutic applications","volume":"18","author":"Chen","year":"2025","journal-title":"Nanomicro Lett"},{"key":"B11","doi-asserted-by":"publisher","first-page":"2439","DOI":"10.1016\/j.jcin.2025.08.031","article-title":"Artificial intelligence in valvular heart disease: innovations and future directions","volume":"18","author":"Maznyczka","year":"2025","journal-title":"JACC Cardiovasc Interv"},{"key":"B12","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1055\/a-1538-6295","article-title":"Safety aspects of perinatal ultrasound","volume":"42","author":"Sande","year":"2021","journal-title":"Ultraschall Med"},{"key":"B13","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00117-020-00659-5","article-title":"[Safety aspects of ultrasound diagnostics]","volume":"60","author":"Jenderka","year":"2020","journal-title":"Radiologe"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.2174\/1573405620666230817092327","article-title":"Safety of ultrasound exposure: awareness of ultrasound bioeffects among Saudi sonographers","volume":"20","author":"Gareeballah","year":"2023","journal-title":"Curr Med Imaging"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.3390\/brainsci12101277","article-title":"Safety of clinical ultrasound neuromodulation","volume":"12","author":"Radjenovic","year":"2022","journal-title":"Brain Sci"},{"key":"B16","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1055\/a-1074-0722","article-title":"Safety indices of ultrasound: adherence to recommendations and awareness during routine obstetric ultrasound scanning","volume":"41","author":"Drukker","year":"2020","journal-title":"Ultraschall Med"},{"key":"B17","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1002\/ajum.12169","article-title":"Do current Philips ultrasound systems exceed the recommended safety limits during routine prenatal ultrasounds?","volume":"22","author":"Ong","year":"2019","journal-title":"Australas J Ultrasound Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1111\/echo.14344","article-title":"Safety profile of ultrasound enhancing agents in echocardiography","volume":"36","author":"Kumar","year":"2019","journal-title":"Echocardiography"},{"key":"B19","doi-asserted-by":"publisher","first-page":"2469","DOI":"10.1007\/s11548-025-03496-w","article-title":"Point cloud registration algorithm using liver vascular skeleton feature with computed tomography and ultrasonography image fusion","volume":"20","author":"Miura","year":"2025","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"B20","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1007\/s11548-024-03247-3","article-title":"Semi-automatic robotic puncture system based on deformable soft tissue point cloud registration","volume":"20","author":"Zhang","year":"2025","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.3233\/SHTI240782","article-title":"Remote monitoring, AI, machine learning and mobile ultrasound integration upon 5G internet in the prehospital care to support the golden hour principle and optimize outcomes in severe trauma and emergency surgery","volume":"316","author":"Mammas","year":"2024","journal-title":"Stud Health Technol Inform"},{"key":"B22","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1055\/a-1978-5575","article-title":"Best practice recommendations for the safe use of lung ultrasound","volume":"44","author":"Wolfram","year":"2023","journal-title":"Ultraschall Med"},{"key":"B23","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.mcna.2024.08.003","article-title":"Safety, ergonomics and patient centered point-of-care ultrasound","volume":"109","author":"Fowlkes","year":"2025","journal-title":"Med Clin North Am"},{"key":"B24","doi-asserted-by":"publisher","first-page":"2161","DOI":"10.1007\/s00247-021-05223-4","article-title":"Contrast-enhanced ultrasound: a comprehensive review of safety in children","volume":"51","author":"Ntoulia","year":"2021","journal-title":"Pediatr Radiol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"NP263","DOI":"10.1093\/asj\/sjad377","article-title":"Augmented safety profile of ultrasound-guided gluteal fat transfer: retrospective study with 1815 patients","volume":"44","author":"Vidal-Laureano","year":"2024","journal-title":"Aesthet Surg J"},{"key":"B26","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1177\/01617346241307637","article-title":"Study on a strategy to improve the image quality and imaging depth for novel synthetic aperture schemes: an experimental investigation","volume":"47","author":"Seetharaman","year":"2025","journal-title":"Ultrason Imaging"},{"key":"B27","doi-asserted-by":"publisher","first-page":"624","DOI":"10.3390\/s22020624","article-title":"Acoustic power measurement and thermal bioeffect evaluation of therapeutic langevin transducers","volume":"22","author":"Kim","year":"2022","journal-title":"Sensors (Basel)"},{"key":"B28","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1016\/j.ultrasmedbio.2025.02.005","article-title":"Acoustic cavitation emissions predict near-complete\/complete histotripsy treatment in soft tissues","volume":"51","author":"Haskell","year":"2025","journal-title":"Ultrasound Med Biol"},{"key":"B29","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1002\/jcu.70154","article-title":"Assessing acoustic safety in prenatal ultrasound: a comparative study of Doppler and B-mode examinations","volume":"54","author":"Farzanegan","year":"2026","journal-title":"J Clin Ultrasound."},{"key":"B30","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1007\/s10396-021-01187-y","article-title":"Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver","volume":"49","author":"Yang","year":"2022","journal-title":"J Med Ultrason (2001)"},{"key":"B31","doi-asserted-by":"publisher","first-page":"107699","DOI":"10.1016\/j.ultras.2025.107699","article-title":"Study of heat transfer and flow within atherosclerotic plaques in a focused ultrasound field","volume":"154","author":"Lei","year":"2025","journal-title":"Ultrasonics"},{"key":"B32","doi-asserted-by":"publisher","first-page":"107263","DOI":"10.1016\/j.ultras.2024.107263","article-title":"The impact of ischemic vascular stenosis on LIPU hyperthermia efficacy investigated based on in vivo rabbit limb ischemia model","volume":"138","author":"Zhang","year":"2024","journal-title":"Ultrasonics"},{"key":"B33","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1109\/RBME.2021.3081180","article-title":"Recent advances in atherosclerotic disease screening using pervasive healthcare","volume":"15","author":"Luo","year":"2022","journal-title":"IEEE Rev Biomed Eng"},{"key":"B34","doi-asserted-by":"publisher","first-page":"1348","DOI":"10.1016\/j.ultrasmedbio.2022.02.024","article-title":"B\/A measurement of clear cell renal cell carcinoma versus healthy kidney tissue","volume":"48","author":"Panfilova","year":"2022","journal-title":"Ultrasound Med Biol"},{"key":"B35","doi-asserted-by":"publisher","first-page":"946","DOI":"10.3390\/bioengineering12090946","article-title":"Experimental validation of time-explicit ultrasound propagation models with sound diffusivity or viscous attenuation in biological tissues using COMSOL multiphysics","volume":"12","author":"Fernandes","year":"2025","journal-title":"Bioengineering (Basel"},{"key":"B36","doi-asserted-by":"publisher","first-page":"106455","DOI":"10.1016\/j.ultsonch.2023.106455","article-title":"Weakly nonlinear focused ultrasound in viscoelastic media containing multiple bubbles","volume":"97","author":"Kagami","year":"2023","journal-title":"Ultrason Sonochem"},{"key":"B37","doi-asserted-by":"publisher","first-page":"2045","DOI":"10.1002\/jum.16223","article-title":"A multivariable model based on ultrasound imaging features of gastrocnemius muscle to identify patients with sarcopenia","volume":"42","author":"Xu","year":"2023","journal-title":"J Ultrasound Med"},{"key":"B38","doi-asserted-by":"publisher","first-page":"1963","DOI":"10.1002\/jum.15578","article-title":"Optimization of mechanical indices for clinical contrast-enhanced ultrasound","volume":"40","author":"Piskunowicz","year":"2021","journal-title":"J Ultrasound Med"},{"key":"B39","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1109\/TBME.2023.3321743","article-title":"Nonlinear frequency mixing ultrasound imaging of nanoscale contrast agents","volume":"71","author":"Karlinsky","year":"2024","journal-title":"IEEE Trans Biomed Eng"},{"key":"B40","doi-asserted-by":"publisher","first-page":"37562","DOI":"10.1021\/acsami.5c05638","article-title":"The role of acoustic parameters in droplet vaporization of perfluoropentane nanodroplets for in vivo applications","volume":"17","author":"Eom","year":"2025","journal-title":"ACS Appl Mater Interfaces"},{"key":"B41","doi-asserted-by":"publisher","first-page":"045013","DOI":"10.1088\/2632-2153\/ac9bcc","article-title":"Improving breast cancer diagnosis by incorporating raw ultrasound parameters into machine learning","volume":"3","author":"Baek","year":"2022","journal-title":"Mach Learn Sci Technol"},{"key":"B42","doi-asserted-by":"publisher","first-page":"112.e1","DOI":"10.1016\/j.ajog.2024.07.021","article-title":"Deep learning-assisted two-dimensional transperineal ultrasound for analyzing bladder neck motion in women with stress urinary incontinence","volume":"232","author":"Wang","year":"2025","journal-title":"Am J Obstet Gynecol"},{"key":"B43","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1186\/s12931-025-03325-3","article-title":"Open-access ultrasonic diaphragm dataset and an automatic diaphragm measurement using deep learning network","volume":"26","author":"Li","year":"2025","journal-title":"Respir Res"},{"key":"B44","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1186\/s12859-022-04794-9","article-title":"A state-of-the-art technique to perform cloud-based semantic segmentation using deep learning 3D U-net architecture","volume":"23","author":"Shaukat","year":"2022","journal-title":"BMC Bioinformatics"},{"key":"B45","doi-asserted-by":"publisher","first-page":"4188","DOI":"10.1158\/0008-5472.CAN-21-0950","article-title":"NCI Imaging data commons","volume":"81","author":"Fedorov","year":"2021","journal-title":"Cancer Res"},{"key":"B46","doi-asserted-by":"publisher","first-page":"109037","DOI":"10.1016\/j.cmpb.2025.109037","article-title":"DECODE: an open-source cloud-based platform for the noninvasive management of peripheral artery disease","volume":"272","author":"AboArab","year":"2025","journal-title":"Comput Methods Programs Biomed"},{"key":"B47","doi-asserted-by":"publisher","first-page":"103639","DOI":"10.1016\/j.media.2025.103639","article-title":"An orchestration learning framework for ultrasound imaging: prompt-guided hyper-perception and attention-matching downstream synchronization","volume":"104","author":"Lin","year":"2025","journal-title":"Med Image Anal"},{"key":"B48","doi-asserted-by":"publisher","first-page":"8326","DOI":"10.3390\/s22218326","article-title":"Computer-Aided diagnosis methods for high-frequency ultrasound data analysis: a review","volume":"22","author":"Czajkowska","year":"2022","journal-title":"Sensors (Basel)"},{"key":"B49","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1109\/TUFFC.2022.3163621","article-title":"Lightweight and amplitude-free ultrasonic imaging using single-bit digitization and instantaneous phase coherence","volume":"69","author":"Gauthier","year":"2022","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"B50","doi-asserted-by":"publisher","first-page":"giab018","DOI":"10.1093\/gigascience\/giab018","article-title":"Rapid development of cloud-native intelligent data pipelines for scientific data streams using the HASTE toolkit","volume":"10","author":"Blamey","year":"2021","journal-title":"Gigascience"},{"key":"B51","doi-asserted-by":"publisher","first-page":"707437","DOI":"10.3389\/fmed.2021.707437","article-title":"Deep learning assisted detection of abdominal free fluid in Morison's pouch during focused assessment with sonography in trauma","volume":"8","author":"Cheng","year":"2021","journal-title":"Front Med (Lausanne)"},{"key":"B52","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1053\/j.ackd.2021.07.004","article-title":"Deep learning in kidney ultrasound: overview, frontiers, and challenges","volume":"28","author":"De Jesus-Rodriguez","year":"2021","journal-title":"Adv Chronic Kidney Dis"},{"key":"B53","doi-asserted-by":"publisher","first-page":"bpaf083","DOI":"10.1093\/biomethods\/bpaf083","article-title":"Limited echocardiogram acquisition by novice clinicians aided with deep learning: a randomized controlled trial","volume":"10","author":"Kumar","year":"2025","journal-title":"Biol Methods Protoc"},{"key":"B54","doi-asserted-by":"publisher","first-page":"102878","DOI":"10.1016\/j.media.2023.102878","article-title":"Robotic ultrasound imaging: state-of-the-art and future perspectives","volume":"89","author":"Jiang","year":"2023","journal-title":"Med Image Anal"},{"key":"B55","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11596-021-2459-2","article-title":"A review of clinical applications for super-resolution ultrasound localization microscopy","volume":"42","author":"Yi","year":"2022","journal-title":"Curr Med Sci"},{"key":"B56","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1055\/a-2157-2587","article-title":"EFSUMB Technical review - update 2023: dynamic contrast-enhanced ultrasound (DCE-CEUS) for the quantification of tumor perfusion","volume":"45","author":"Dietrich","year":"2024","journal-title":"Ultraschall Med"},{"key":"B57","doi-asserted-by":"publisher","first-page":"e20454","DOI":"10.1002\/adma.202520454","article-title":"Ultrasound in Women's Health: mechanisms, applications, and emerging opportunities","volume":"38","author":"Ornellas","year":"2026","journal-title":"Adv Mater"},{"key":"B58","doi-asserted-by":"publisher","first-page":"113703","DOI":"10.1016\/j.jconrel.2025.113703","article-title":"Efficacy and safety of ultrasound combined with microbubbles for treating retinal artery occlusion in rats","volume":"382","author":"Fan","year":"2025","journal-title":"J Control Release"},{"key":"B59","doi-asserted-by":"publisher","first-page":"eadk4321","DOI":"10.1126\/sciadv.adk4321","article-title":"Fast and converged classical simulations of evidence for the utility of quantum computing before fault tolerance","volume":"10","author":"Begu\u0161i\u0107","year":"2024","journal-title":"Sci Adv"},{"key":"B60","doi-asserted-by":"publisher","first-page":"3279","DOI":"10.1039\/d3sc05807g","article-title":"Machine learning assisted construction of a shallow depth dynamic ansatz for noisy quantum hardware","volume":"15","author":"Halder","year":"2024","journal-title":"Chem Sci"},{"key":"B61","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1136\/bmjebm-2020-111499","article-title":"Quality of early evidence on the pathogenesis, diagnosis, prognosis and treatment of COVID-19","volume":"26","author":"Yang","year":"2021","journal-title":"BMJ Evid Based Med"},{"key":"B62","doi-asserted-by":"publisher","first-page":"e474","DOI":"10.1161\/CIR.0000000000001385","article-title":"Genetic and genomic testing in cardiovascular disease: a policy statement from the American Heart Association","volume":"152","author":"Landstrom","year":"2025","journal-title":"Circulation"},{"key":"B63","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1038\/s41586-022-04623-2","article-title":"Transitioning organizations to post-quantum cryptography","volume":"605","author":"Joseph","year":"2022","journal-title":"Nature"}],"container-title":["Frontiers in Medical Technology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2026.1775679\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T05:21:40Z","timestamp":1788412900000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmedt.2026.1775679\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":63,"alternative-id":["10.3389\/fmedt.2026.1775679"],"URL":"https:\/\/doi.org\/10.3389\/fmedt.2026.1775679","relation":{},"ISSN":["2673-3129"],"issn-type":[{"value":"2673-3129","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]},"article-number":"1775679"}}