{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T15:49:04Z","timestamp":1790092144579,"version":"4.0.1"},"reference-count":22,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T00:00:00Z","timestamp":1606953600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100014996","name":"Health Commission of Zhejiang Province","doi-asserted-by":"publisher","award":["WKJ-ZJ-2014"],"award-info":[{"award-number":["WKJ-ZJ-2014"]}],"id":[{"id":"10.13039\/501100014996","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Self-expanding devices, such as the Enterprise VRD (EP-VRD) have widely used for stent-assisted coiling treatment in wided-necked aneuryms while some thromboembolic complications were reported due to its incomplete stent apposition (ISA). We report our experiences on the novel Enterprise2 (EP-VRD2) stent <jats:italic>in vivo<\/jats:italic> in the treatment of intracranial and cranial cervical junction aneurysms.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Twenty-five consecutive patients with intracranial or cranial cervical junction aneurysms were treated with EP-VRD2 stents retrospectively collected in our institution. We use the \u2018jailing' technique in all cases and deployed the stent by using pushing over the outer curve technique. The 3- or 6-monthS follow-up was done regularly by DSA.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Twenty-five EP-VRD2 stents were implanted to treat 21 aneurysms at the siphon segment of internal carotid artery (ICA), one at the petrous segment, two at the cervical segment, one at the verteral artery with five accompanied with stenosis. Two patients had kinking during the procedure and were solved by microwire or microcatheter massaging. Four patients with a larger arc angle and a smaller radius of the parent vessel was detected ISA. No patient underwent the ischemic event after the operation. Twenty-three of 25 patients were evaluated after 3- or 6-months by DSA, 22 showed complete occlusion (RROC1), one slight re-stenosis in the follow-up within those five patients with stenosis. A length of 23 mm seemed associated with ISA (<jats:italic>p<\/jats:italic> &amp;lt; 0.01).<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> The EP-VRD2 performed well in our small patient series; however, ISA could still occur with a sharp angle of the parent vessel.<\/jats:p>","DOI":"10.3389\/fneur.2020.589689","type":"journal-article","created":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T08:04:03Z","timestamp":1606982643000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["The Enterprise2 Stent for Endovascular Treatment of Intracranial Aneurysms: Short-Term Results From a Single Center Experience"],"prefix":"10.3389","volume":"11","author":[{"given":"Linhui","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaobo","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiong","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Gong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhai","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shu","family":"Wan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2020,12,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"339","DOI":"10.3174\/ajnr.A3658","article-title":"Analysis of complications and recurrences of aneurysm coiling with special emphasis on the stent-assisted technique","volume":"35","author":"Nishido","year":"2014","journal-title":"AJNR Am J Neuroradiol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"2497","DOI":"10.1161\/STROKEAHA.107.512756","article-title":"Immediate clinical outcome of patients harboring unruptured intracranial aneurysms treated by endovascular approach: results of the ATENA study","volume":"39","author":"Pierot","year":"2008","journal-title":"Stroke"},{"key":"B3","doi-asserted-by":"publisher","first-page":"2046","DOI":"10.1161\/STROKEAHA.113.000733","article-title":"Endovascular treatment of intracranial aneurysms: current status","volume":"44","author":"Pierot","year":"2013","journal-title":"Stroke."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.3174\/ajnr.A2453","article-title":"Better outcomes with treatment by coiling relative to clipping of unruptured intracranial aneurysms in the United States, 2001-2008","volume":"32","author":"Brinjikji","year":"2011","journal-title":"AJNR Am J Neuroradiol."},{"key":"B5","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1177\/159101991201800408","article-title":"Enterprise stent-assisted coiling of wide-necked intracranial aneurysms: clinical and angiographic follow-up","volume":"18","author":"Jia","year":"2012","journal-title":"Interv Neuroradiol J Peritherapeutic Neuroradiol Surg Proced Relat Neurosci."},{"key":"B6","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1186\/s12883-015-0443-9","article-title":"Enterprise stent for the treatment of symptomatic intracranial atherosclerotic stenosis: an initial experience of 44 patients","volume":"15","author":"Feng","year":"2015","journal-title":"BMC Neurol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1177\/1591019915609165","article-title":"Undersized angioplasty and stenting of symptomatic intracranial tight stenosis with Enterprise: evaluation of clinical and vascular outcome","volume":"22","author":"Lee","year":"2016","journal-title":"Interv Neuroradiol J Peritherapeutic Neuroradiol Surg Proced Relat Neurosci."},{"key":"B8","doi-asserted-by":"publisher","first-page":"453","DOI":"10.3171\/2014.10.JNS141361","article-title":"Complication analysis in nitinol stent-assisted embolization of 486 intracranial aneurysms","volume":"123","author":"Johnson","year":"2015","journal-title":"J Neurosurg."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.3171\/2013.2.JNS121427","article-title":"Incomplete stent apposition in Enterprise stent-mediated coiling of aneurysms: persistence over time and risk of delayed ischemic events","volume":"118","author":"Heller","year":"2013","journal-title":"J Neurosurg."},{"key":"B10","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s00701-015-2666-3","article-title":"In vitro experiments of vessel wall apposition between the Enterprise and Enterprise 2 stents for treatment of cerebral aneurysms","volume":"158","author":"Kono","year":"2016","journal-title":"Acta Neurochir (Wien)."},{"key":"B11","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1136\/neurintsurg-2016-012400","article-title":"Deployment technique that takes advantage of the characteristics of Enterprise VRD2: an in vitro study","volume":"9","author":"Chihara","year":"2017","journal-title":"J Neurointerventional Surg."},{"key":"B12","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s00062-016-0545-9","article-title":"First experiences with the new enterprise2\u00ae stent","volume":"28","author":"Herweh","year":"2018","journal-title":"Clin Neuroradiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1998","DOI":"10.1161\/hs0901.095600","article-title":"Endovascular treatment of unruptured aneurysms","volume":"32","author":"Roy","year":"2001","journal-title":"Stroke."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1714","DOI":"10.3174\/ajnr.A2584","article-title":"Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling","volume":"32","author":"Heller","year":"2011","journal-title":"AJNR Am J Neuroradiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1136\/neurintsurg-2014-011457","article-title":"Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with Enterprise and Neuroform stents: a comparative analysis of the literature","volume":"7","author":"King","year":"2015","journal-title":"J Neurointerventional Surg."},{"key":"B16","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.wneu.2016.04.057","article-title":"LVIS stent versus enterprise stent for the treatment of unruptured intracranial aneurysms","volume":"91","author":"Ge","year":"2016","journal-title":"World Neurosurg."},{"key":"B17","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1097\/00006123-199603000-00001","article-title":"Segments of the internal carotid artery: a new classification","volume":"38","author":"Bouthillier","year":"1996","journal-title":"Neurosurgery."},{"key":"B18","doi-asserted-by":"publisher","first-page":"301","DOI":"10.7461\/jcen.2015.17.4.301","article-title":"Outcomes of stent-assisted coil embolization of wide-necked intracranial aneurysms using the solitairetm AB neurovascular remodeling device","volume":"17","author":"Jeong","year":"2015","journal-title":"J Cerebrovasc Endovasc Neurosurg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1161\/STROKEAHA.113.003038","article-title":"Extending the indications of flow diversion to small, unruptured, saccular aneurysms of the anterior circulation","volume":"45","author":"Chalouhi","year":"2014","journal-title":"Stroke."},{"key":"B20","first-page":"823","article-title":"Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study","volume":"28","author":"Ebrahimi","year":"2007","journal-title":"AJNR Am J Neuroradiol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"624","DOI":"10.3171\/2011.4.JNS102050","article-title":"Crescent sign on magnetic resonance angiography revealing incomplete stent apposition: correlation with diffusion-weighted changes in stent-mediated coil embolization of aneurysms","volume":"115","author":"Heller","year":"2011","journal-title":"J Neurosurg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1136\/jnis.2010.002444","article-title":"Proximal migration and compaction of an Enterprise stent into a coiled basilar apex aneurysm: a posterior circulation phenomenon?","volume":"2","author":"Dashti","year":"2010","journal-title":"J Neurointerventional Surg."}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2020.589689\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T08:04:04Z","timestamp":1606982644000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2020.589689\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,3]]},"references-count":22,"alternative-id":["10.3389\/fneur.2020.589689"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2020.589689","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,3]]},"article-number":"589689"}}