{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:03:53Z","timestamp":1790744633364,"version":"4.1.0"},"reference-count":20,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,2,5]],"date-time":"2021-02-05T00:00:00Z","timestamp":1612483200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:p><jats:bold>Introduction:<\/jats:bold> In confirming the clinical diagnosis of carpal tunnel syndrome (CTS), ultrasonography (US) is the recommended first diagnostic test in The Netherlands. One of the most important parameters for an abnormal US result is an increase of the CSA of the median nerve at the carpal tunnel inlet. An earlier study showed that a wrist-circumference dependent cut-off for the upper limit of normal of this CSA might be superior to a fixed cut-off of 11 mm<jats:sup>2<\/jats:sup>. In this study we compared three ultrasonography (US) parameters in three large Dutch hospitals.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Patients with a clinical suspicion of CTS and with reasonable exclusion of other causes of their symptoms were prospectively included. A total number of 175 patients were analysed. The primary goal was to compare the number of wrists with an abnormal US result while using a fixed cut-off of 11 mm<jats:sup>2<\/jats:sup> (FC), a wrist circumference-dependent cut-off (y = 0.88 <jats:sup>*<\/jats:sup> x\u22124, where y = ULN and x = wrist circumference in centimetres; abbreviated as WDC), and an intraneural flow related cut-off (IFC).<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> The WDC considered more US examinations to be abnormal (55.4%) than the FC (50.3%) did, as well as the IFC (46.9%), with a statistically significant difference of <jats:italic>p<\/jats:italic> = 0.035 and <jats:italic>p<\/jats:italic> = 0.001, respectively. The WDC detected 12 abnormal median nerves while the FC did not, and 18 while the IFC did not. The wrist circumference of the patients of these subgroups turned out to be significantly smaller (<jats:italic>p<\/jats:italic> &amp;lt; 0.001) when compared with the rest of the group.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> According to these study results, the wrist-circumference dependent cut-off value for the CSA of the median nerve at the wrist appears to have a higher sensitivity than either a fixed cut-off value of 11 mm<jats:sup>2<\/jats:sup> or cut-off values based on intraneural flow, and may add most value in patients with a smaller wrist circumference.<\/jats:p>","DOI":"10.3389\/fneur.2021.625565","type":"journal-article","created":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T04:38:44Z","timestamp":1612759124000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Wrist Circumference-Dependent Upper Limit of Normal for the Cross-Sectional Area Is Superior Over a Fixed Cut-Off Value in Confirming the Clinical Diagnosis of Carpal Tunnel Syndrome"],"prefix":"10.3389","volume":"12","author":[{"given":"Tom B. G.","family":"Olde Dubbelink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Floriaan G. C. M.","family":"De Kleermaeker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roy","family":"Beekman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juerd","family":"Wijntjes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald H. M. A.","family":"Bartels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Meulstee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wim I. M.","family":"Verhagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,2,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1001\/jama.282.2.153","article-title":"Prevalence of carpal tunnel syndrome in a general population","volume":"282","author":"Atroshi","year":"1999","journal-title":"J Am Med Assoc."},{"key":"B2","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1016\/0895-4356(92)90038-O","article-title":"Carpal tunnel syndrome: prevalence in the general population","volume":"45","author":"De Krom","year":"1992","journal-title":"J Clin Epidemiol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1056\/NEJMcp013018","article-title":"Clinical practice. Carpal tunnel syndrome","volume":"346","author":"Katz","year":"2002","journal-title":"N Engl J Med."},{"key":"B4","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1097\/CND.0b013e31824619ad","article-title":"Interobserver agreement in case history evaluation in carpal tunnel syndrome","volume":"13","author":"Westerman","year":"2012","journal-title":"J Clin Neuromuscul Dis."},{"key":"B5","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/J.JHSE.2007.09.007","article-title":"Current practice in the use of nerve conduction studies in carpal tunnel syndrome by surgeons in the netherlands","volume":"32","author":"Claes","year":"2007","journal-title":"J Hand Surg Eur Vol."},{"key":"B6","unstructured":"Richtlijn carpaletunnelsyndroom2017"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1016\/j.ultrasmedbio.2012.02.026","article-title":"Ultrasonography for diagnosing carpal tunnel syndrome: a meta-analysis of diagnostic test accuracy","volume":"38","author":"Tai","year":"2012","journal-title":"Ultrasound Med Biol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"793","DOI":"10.2214\/ajr.159.4.1529845","article-title":"Carpal tunnel syndrome: diagnosis with high-resolution sonography","volume":"159","author":"Buchberger","year":"1992","journal-title":"Am J Roentgenol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1002\/mus.23528","article-title":"Reasons for using swelling ratio in sonographic diagnosis of carpal tunnel syndrome and a reliable method for its calculation","volume":"47","author":"Ula\u015fli","year":"2013","journal-title":"Muscle and Nerve."},{"key":"B10","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1002\/mus.24241","article-title":"Doppler sonography for the diagnosis of carpal tunnel syndrome: a critical review","volume":"50","author":"Vanderschueren","year":"2014","journal-title":"Muscle and Nerve."},{"key":"B11","doi-asserted-by":"publisher","first-page":"577052","DOI":"10.3389\/fneur.2020.577052","article-title":"Augmented diagnostic accuracy of ultrasonography for diagnosing carpal tunnel syndrome using an optimised wrist circumference-dependent cross-sectional area equation","volume":"11","author":"Olde Dubbelink","year":"2020","journal-title":"Front Neurol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.jns.2014.06.044","article-title":"Treatment outcome in carpal tunnel syndrome: does distribution of sensory symptoms matter?","volume":"344","author":"Claes","year":"2014","journal-title":"J Neurol Sci."},{"key":"B13","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1136\/jnnp.2007.115337","article-title":"High-resolution sonography versus EMG in the diagnosis of carpal tunnel syndrome","volume":"79","author":"Visser","year":"2008","journal-title":"J Neurol Neurosurg Psychiatry."},{"key":"B14","doi-asserted-by":"publisher","first-page":"938","DOI":"10.1002\/mus.24655","article-title":"High prevalence of increased nerve vascularization in healthy individuals","volume":"51","author":"Houben","year":"2015","journal-title":"Muscle and Nerve."},{"key":"B15","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.cnp.2018.02.005","article-title":"Nerve conduction studies and EMG in carpal tunnel syndrome: do they add value?","volume":"3","author":"Sonoo","year":"2018","journal-title":"Clin Neurophysiol Pract."},{"key":"B16","doi-asserted-by":"publisher","first-page":"2394","DOI":"10.1007\/s00415-017-8637-2","article-title":"Treatment outcome in patients with clinically defined carpal tunnel syndrome but normal electrodiagnostic test results: a randomized controlled trial","volume":"264","author":"De Kleermaeker","year":"2017","journal-title":"J Neurol."},{"key":"B17","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1080\/01616412.2016.1275455","article-title":"Diagnosing carpal tunnel syndrome with Doppler ultrasonography: a comparison of ultrasonographic measurements and electrophysiological severity","volume":"39","author":"Kutlar","year":"2017","journal-title":"Neurol Res."},{"key":"B18","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1007\/s10072-010-0258-9","article-title":"Usefulness of additional measurements of the median nerve with ultrasonography","volume":"31","author":"Claes","year":"2010","journal-title":"Neurol Sci."},{"key":"B19","doi-asserted-by":"publisher","first-page":"1713","DOI":"10.1002\/1097-4598(200011)23:11<1713::AID-MUS7>3.0.CO;2-G","article-title":"Enlarged median nerve in idiopathic carpal tunnel syndrome","volume":"23","author":"Nakamichi","year":"2000","journal-title":"Muscle Nerve."},{"key":"B20","doi-asserted-by":"publisher","first-page":"2985","DOI":"10.1007\/s10072-020-04405-6","article-title":"The hyperchoic rim of the normal nerve in ultrasound: how significant is it?","volume":"41","author":"Coraci","year":"2020","journal-title":"Neurol Sci."}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2021.625565\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T04:38:47Z","timestamp":1612759127000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2021.625565\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,5]]},"references-count":20,"alternative-id":["10.3389\/fneur.2021.625565"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2021.625565","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,5]]},"article-number":"625565"}}