{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T17:50:24Z","timestamp":1792605024045,"version":"4.5.0"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006095","name":"Helse S\u00f8r-\u00d8st RHF","doi-asserted-by":"publisher","award":["2019010"],"award-info":[{"award-number":["2019010"]}],"id":[{"id":"10.13039\/501100006095","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Optic nerve sheath diameter (ONSD) has shown promise as a noninvasive parameter for estimating intracranial pressure (ICP). In this study, we evaluated a novel automated method of measuring the ONSD in transorbital ultrasound imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>From adult traumatic brain injury (TBI) patients with invasive ICP monitoring, bedside manual ONSD measurements and ultrasound videos of the optic nerve sheath complex were simultaneously acquired. Automatic ONSD measurements were obtained by the processing of the ultrasound videos by a novel software based on a machine learning approach for segmentation of the optic nerve sheath. Agreement between manual and automated measurements, as well as their correlation to invasive ICP, was evaluated. Furthermore, the ability to distinguish dichotomized ICP for manual and automatic measurements of ONSD was compared, both for ICP dichotomized at \u226520 mmHg and at the 50th percentile (\u226514 mmHg). Finally, we performed an exploratory subgroup analysis based on the software's judgment of optic nerve axis alignment to elucidate the reasons for variation in the agreement between automatic and manual measurements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 43 ultrasound examinations were performed on 25 adult patients with TBI, resulting in 86 image sequences covering the right and left eyes. The median pairwise difference between automatically and manually measured ONSD was 0.06 mm (IQR \u22120.44 to 0.38 mm;\n                      <jats:italic>p<\/jats:italic>\n                      = 0.80). The manually measured ONSD showed a positive correlation with ICP, while automatically measured ONSD showed a trend toward, but not a statistically significant correlation with ICP. When examining the ability to distinguish dichotomized ICP, manual and automatic measurements performed with similar accuracy both for an ICP cutoff at 20 mmHg (manual: AUC 0.74, 95% CI 0.58\u20130.88; automatic: AUC 0.83, 95% CI 0.66\u20130.93) and for an ICP cutoff at 14 mmHg (manual: AUC 0.70, 95% CI 0.52\u20130.85; automatic: AUC 0.68, 95% CI 0.48\u20130.83). In the exploratory subgroup analysis, we found that the agreement between measurements was higher in the subgroup where the automatic software evaluated the optic nerve axis alignment as good as compared to intermediate\/poor.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The novel automated method of measuring the ONSD on the ultrasound videos using segmentation of the optic nerve sheath showed a reasonable agreement with manual measurements and performed equally well in distinguishing high and low ICP.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fneur.2023.1064492","type":"journal-article","created":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:48:52Z","timestamp":1675212532000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":16,"title":["Noninvasive intracranial pressure assessment by optic nerve sheath diameter: Automated measurements as an alternative to clinician-performed measurements"],"prefix":"10.3389","volume":"14","author":[{"given":"Dag Ferner","family":"Netteland","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mads","family":"Aarhus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Smistad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Else Charlotte","family":"Sandset","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Llewellyn","family":"Padayachy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eirik","family":"Helseth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reidar","family":"Brekken","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,2,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1227\/NEU.0000000000001432","article-title":"Guidelines for the management of severe traumatic brain injury, fourth edition","volume":"80","author":"Carney","year":"2017","journal-title":"Neurosurgery."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.1007\/s00134-022-06786-y","article-title":"Intracranial pressure: current perspectives on physiology and monitoring","volume":"48","author":"Hawryluk","year":"2022","journal-title":"Intensive Care Med."},{"key":"B3","doi-asserted-by":"publisher","first-page":"E6","DOI":"10.3171\/2017.8.FOCUS17450","article-title":"Complications of invasive intracranial pressure monitoring devices in neurocritical care","volume":"43","author":"Tavakoli","year":"2017","journal-title":"Neurosurg Focus."},{"key":"B4","doi-asserted-by":"publisher","first-page":"34","DOI":"10.3171\/jns.1997.87.1.0034","article-title":"Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests","volume":"87","author":"Hansen","year":"1997","journal-title":"J Neurosurg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","article-title":"Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients","volume":"34","author":"Geeraerts","year":"2008","journal-title":"Intensive Care Med."},{"key":"B6","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1007\/s12028-011-9606-8","article-title":"Optic nerve ultrasound for the detection of raised intracranial pressure","volume":"15","author":"Rajajee","year":"2011","journal-title":"Neurocrit Care."},{"key":"B7","doi-asserted-by":"publisher","first-page":"e1002356","DOI":"10.1371\/journal.pmed.1002356","article-title":"Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study","volume":"14","author":"Robba","year":"2017","journal-title":"PLoS Med."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1007\/s00134-018-5305-7","article-title":"Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis","volume":"44","author":"Robba","year":"2018","journal-title":"Intensive Care Med."},{"key":"B9","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/S0929-8266(02)00036-8","article-title":"Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults","volume":"15","author":"Ballantyne","year":"2002","journal-title":"Eur J Ultrasound."},{"key":"B10","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1111\/j.1552-6569.2010.00546.x","article-title":"Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults","volume":"22","author":"B\u00e4uerle","year":"2012","journal-title":"J Neuroimaging."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.7863\/ultra.16.05055","article-title":"Inter-rater reliability of sonographic optic nerve sheath diameter measurements by emergency medicine physicians","volume":"36","author":"Oberfoell","year":"2017","journal-title":"J Ultrasound Med."},{"key":"B12","doi-asserted-by":"publisher","first-page":"2191","DOI":"10.1001\/jama.2013.281053","article-title":"World medical association declaration of Helsinki: ethical principles for medical research involving human subjects","volume":"310","year":"2013","journal-title":"JAMA"},{"key":"B13","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1227\/01.NEU.0000156609.95596.24","article-title":"Clinical experience with the intraparenchymal intracranial pressure monitoring Codman microsensor system","volume":"56","author":"Koskinen","year":"2005","journal-title":"Neurosurgery."},{"key":"B14","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/S0140-6736(74)91639-0","article-title":"Assessment of coma and impaired consciousness. A practical scale","volume":"2","author":"Teasdale","year":"1974","journal-title":"Lancet"}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2023.1064492\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:48:54Z","timestamp":1675212534000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2023.1064492\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,1]]},"references-count":14,"alternative-id":["10.3389\/fneur.2023.1064492"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2023.1064492","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,1]]},"article-number":"1064492"}}