{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T23:26:14Z","timestamp":1792020374499,"version":"4.4.0"},"reference-count":22,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T00:00:00Z","timestamp":1691971200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81601583"],"award-info":[{"award-number":["81601583"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>The present study aimed to investigate the application of the aneurysm embolization microcatheter plasticity method based on computational fluid dynamics (CFD) to simulate cerebral blood flow in the interventional treatment of posterior communicating aneurysms in the internal carotid artery and to evaluate its practicality and safety.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A total of 20 patients with posterior internal carotid artery communicating aneurysms who used CFD to simulate cerebral flow lines from January 2020 to December 2022 in our hospital were analyzed. Microcatheter shaping and interventional embolization were performed according to the main cerebral flow lines, and the success rate, stability, and effect of the microcatheter being in place were analyzed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Among the 20 patients, the microcatheters were all smoothly placed and the catheters were stable during the <jats:italic>in vitro<\/jats:italic> model test. In addition, the microcatheters were all smoothly placed during the operation, with a success rate of 100%. The catheter tips were stable and well-supported intraoperatively, and no catheter prolapse was registered. The aneurysm was completely embolized in 19 cases immediately after surgery, and a small amount of the aneurysm neck remained in one case. There were no intraoperative complications related to the embolization catheter operation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Microcatheter shaping based on CFD simulation of cerebral blood flow, with precise catheter shaping, leads to a high success rate in catheter placing, stability, and good support, and greatly reduces the difficulty of catheter shaping. This catheter-shaping method is worthy of further study and exploration.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fneur.2023.1221686","type":"journal-article","created":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T11:07:22Z","timestamp":1692011242000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Application of microcatheter shaping based on computational fluid dynamics simulation of cerebral blood flow in the intervention of posterior communicating aneurysm of the internal carotid artery"],"prefix":"10.3389","volume":"14","author":[{"given":"Gangqin","family":"Xu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yueyang","family":"Ba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongyang","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bowen","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tongyuan","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiangyu","family":"Xue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,8,14]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"e183","DOI":"10.1016\/j.wneu.2019.01.037","article-title":"The outcome of ruptured posterior communicating artery aneurysm treatment comparing between clipping and coiling techniques","volume":"125","author":"Taweesomboonyat","year":"2019","journal-title":"World Neurosurg"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"E130","DOI":"10.1148\/radiol.2020204013","article-title":"Intraoperative complications of endovascular treatment of intracranial aneurysms with coiling or balloon-assisted coiling in a prospective Multicenter cohort of 1088 participants: analysis of recanalization after endovascular treatment of intracranial aneurysm (Areta) study","volume":"296","author":"Pierot","year":"2020","journal-title":"Radiology"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1148\/radiol.2015142496","article-title":"Intracranial aneurysms: recurrences more than 10 years after endovascular treatment-a prospective cohort study, systematic review, and Meta-analysis","volume":"277","author":"Lecler","year":"2015","journal-title":"Radiology"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1148\/radiol.10091982","article-title":"Endovascular treatment of intracranial Unruptured aneurysms: systematic review and Meta-analysis of the literature on safety and efficacy","volume":"256","author":"Naggara","year":"2010","journal-title":"Radiology"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.jimed.2020.07.006","article-title":"Safety and efficacy of complete versus near-complete coiling in treatment of intracranial aneurysms","volume":"3","author":"Zhang","year":"2020","journal-title":"J Interv Med"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1227\/01.NEU.0000370891.67129.2F","article-title":"Shaping and navigating methods of microcatheters for endovascular treatment of Paraclinoid aneurysms","volume":"67","author":"Kwon","year":"2010","journal-title":"Neurosurgery"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"649","DOI":"10.3174\/ajnr.A2841","article-title":"Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle Remodeling","volume":"33","author":"Gao","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1136\/neurintsurg-2013-010920","article-title":"Endovascular treatment of intracranial aneurysms with detachable coils: correlation between aneurysm volume, packing, and angiographic recurrence","volume":"6","author":"Leng","year":"2014","journal-title":"J Neurointerv Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"249","DOI":"10.25259\/SNI_443_2019","article-title":"Epidemiological analysis of 1404 patients with intracranial aneurysm followed in a single Brazilian institution","volume":"10","author":"J\u00fanior","year":"2019","journal-title":"Surg Neurol Int"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"848","DOI":"10.3171\/2019.12.JNS192755","article-title":"Volumes, outcomes, and complications after surgical versus endovascular treatment of aneurysms in the United States (1993-2015): continued evolution versus steady-state after more than 2 decades of practice","volume":"134","author":"Golnari","year":"2020","journal-title":"J Neurosurg"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"308","DOI":"10.3174\/ajnr.A1374","article-title":"Coil embolization of very small (2 mm or smaller) berry aneurysms: feasibility and technical issues","volume":"30","author":"Gupta","year":"2009","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s00234-010-0735-0","article-title":"Endovascular coil embolization of very small intracranial aneurysms","volume":"53","author":"Hwang","year":"2011","journal-title":"Neuroradiology"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1159\/000345264","article-title":"Preoperative three-dimensional model creation of magnetic resonance brain images as a tool to assist neurosurgical planning","volume":"91","author":"Spottiswoode","year":"2013","journal-title":"Stereotact Funct Neurosurg"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1136\/neurintsurg-2018-014259","article-title":"A new method to statistically describe microcatheter tip position in patient-specific aneurysm models","volume":"11","author":"Nawka","year":"2019","journal-title":"J Neurointerv Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1177\/1591019917689926","article-title":"Microcatheter shaping using intravascular placement during intracranial aneurysm coiling","volume":"23","author":"Yamaguchi","year":"2017","journal-title":"Interv Neuroradiol"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1136\/neurintsurg-2017-013087","article-title":"A patient-specific intracranial aneurysm model with endothelial lining: a novel in vitro approach to bridge the gap between biology and flow dynamics","volume":"10","author":"Kaneko","year":"2018","journal-title":"J Neurointerv Surg"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1136\/neurintsurg-2015-011686","article-title":"Three-dimensional printing of anatomically accurate, patient specific intracranial aneurysm models","volume":"8","author":"Anderson","year":"2016","journal-title":"J Neurointerv Surg"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.wneu.2015.03.006","article-title":"Microcatheter shaping for intracranial aneurysm coiling using the 3-dimensional printing rapid prototyping technology: preliminary result in the first 10 consecutive cases","volume":"84","author":"Namba","year":"2015","journal-title":"World Neurosurg"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.compbiomed.2016.07.005","article-title":"Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization","volume":"77","author":"Ishibashi","year":"2016","journal-title":"Comput Biol Med"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1136\/neurintsurg-2019-015346","article-title":"Microcatheter shaping using three-dimensional printed models for intracranial aneurysm coiling","volume":"12","author":"Xu","year":"2020","journal-title":"J Neurointerv Surg"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1007\/s10143-021-01703-1","article-title":"Three-dimensional printing-assisted precision microcatheter shaping in intracranial aneurysm coiling","volume":"45","author":"Song","year":"2022","journal-title":"Neurosurg Rev"},{"key":"ref22","first-page":"2610","article-title":"Shapability, memory, and luminal changes in microcatheters after steam shaping: a comparison of 11 different microcatheters","volume":"26","author":"Kiyosue","year":"2005","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2023.1221686\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T11:07:28Z","timestamp":1692011248000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2023.1221686\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,14]]},"references-count":22,"alternative-id":["10.3389\/fneur.2023.1221686"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2023.1221686","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,14]]},"article-number":"1221686"}}