{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T20:38:23Z","timestamp":1778186303613,"version":"3.51.4"},"reference-count":40,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T00:00:00Z","timestamp":1739404800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Right-to-left shunt (RLS) associated with patent foramen ovale (PFO) is common among cryptogenic strokes. Current diagnostic tools have limitations. Transthoratic echocardiography (TTE) is not as sensitive as Transesophageal echocardiography (TEE), TEE is invasive, and manual transcranial Doppler (TCD) requires trained staff to operate. Robotic automated TCD (raTCD) may be feasible and comparable to manual TCD. The study's purpose was to determine the rate of RLS detection using raTCD and combine the Spencer Logarithmic Scale (SLS) with the Risk of Paradoxical Embolism (RoPE) to identify patients at risk of PFO associated stroke or TIA.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This single-center retrospective cohort study included adult patients (\u226518 y\/o) admitted from December 2021 to December 2022 with a stroke or transient ischemic attack. Those with no bone window or stroke mimics were excluded. Patients with an RLS on raTCD received a second scan at the physician's discretion. The SLS combined with the RoPE score was used to generate a modified screening PFO-Associated Stroke Causal Likelihood (msPASCAL) classification.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Of 212 patients who received raTCD, the mean age was 56, 14% were &amp;gt;65 years old, most were white (72%), predominantly male (59%), 52% had cryptogenic strokes, and 59% had an RLS. Most patients were able to perform Valsalva (89%) during raTCD. Of those with an RLS, 56% had an SLS of 1\u20132, while 44% had an SLS of 3\u20135. There were no significant differences in characteristics by SLS. Most patients with SLS grades 1\u20132 were classified using msPASCAL as unlikely to have PFO as stroke etiology (<jats:italic>n<\/jats:italic> = 55, 44%). A small number of large SLS grades 3\u20135 were considered probable for having a PFO-associated stroke while the rest were classified as possible (<jats:italic>n<\/jats:italic> = 38, 30.4%). Eight patients with positive RLS on raTCD had a negative TTE with bubbles; most of those had small RLS on raTCD (<jats:italic>n<\/jats:italic> = 5, 63%) or could not Valsalva due to sedation ((<jats:italic>n<\/jats:italic> = 6, 75%).<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>This study supports the feasibility of utilizing raTCD for RLS detection. The modified screening PASCAL classification can be generated for RLS patients and may be used to guide subsequent evaluation and management.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fneur.2024.1481817","type":"journal-article","created":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T05:13:50Z","timestamp":1739423630000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Incorporation of robotic automated transcranial Doppler to screen for patent foramen ovale (PFO) and quantify right-to-left shunt severity in the evaluation of ischemic stroke patients for etiology and PFO management"],"prefix":"10.3389","volume":"15","author":[{"given":"Ira","family":"Chang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasaman","family":"Pirahanchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Izaguirre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Rodriguez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alyssa","family":"Wicknick","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2025,2,13]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1161\/JAHA.117.007146","article-title":"Patent foramen ovale closure for stroke prevention and other disorders","volume":"7","author":"Collado","year":"2018","journal-title":"J Am Heart Assoc."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1056\/NEJM198805053181802","article-title":"Prevalence of patent foramen ovale in patients with stroke","volume":"318","author":"Lechat","year":"1988","journal-title":"New Engl J Med."},{"key":"B3","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.iccl.2017.05.002","article-title":"Identification and quantification of patent foramen ovale-mediated shunts","volume":"6","author":"Mahmoud","year":"2017","journal-title":"Int Cardiol Clin."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1322","DOI":"10.1161\/01.STR.29.7.1322","article-title":"The need to quantify right-to-left shunt in acute ischemic stroke a case-control study","volume":"29","author":"Serena","year":"1998","journal-title":"Stroke."},{"key":"B5","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1136\/hrt.2004.052233","article-title":"When and how to diagnose patent foramen ovale","volume":"91","author":"Pinto","year":"2005","journal-title":"Heart."},{"key":"B6","doi-asserted-by":"publisher","first-page":"567","DOI":"10.3389\/fneur.2020.00567","article-title":"Patent foramen ovale in cryptogenic ischemic stroke: direct cause, risk factor, or incidental finding?","volume":"11","author":"Ioannidis","year":"2020","journal-title":"Front Neurol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1016\/j.jacc.2017.12.059","article-title":"Cryptogenic stroke and patent foramen ovale","volume":"71","author":"Mojadidi","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fneur.2020.00434","article-title":"A narrative and critical review of randomized-controlled clinical trials on patent foramen ovale closure for reducing the risk of stroke recurrence","volume":"11","author":"Safouris","year":"2020","journal-title":"Front Neurol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1161\/STROKEAHA.117.018153","article-title":"Patent foramen ovale closure versus medical therapy for cryptogenic ischemic stroke a topical review","volume":"44","author":"Saver","year":"2018","journal-title":"Stroke."},{"key":"B10","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1001\/jama.2021.20956","article-title":"Heterogeneity of treatment effects in an analysis of pooled individual patient data from randomized trials of device closure of patent foramen ovale after stroke","volume":"326","author":"Kent","year":"2021","journal-title":"JAMA."},{"key":"B11","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1002\/ana.24609","article-title":"Transcranial Doppler versus transthoracic echocardiography for the detection of patent foramen ovale in patients with cryptogenic cerebral ischemia: a systemic review and diagnostic test accuracy meta-analysis","volume":"79","author":"Katsanos","year":"2016","journal-title":"Ann Neurol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1159\/000430998","article-title":"The RoPE score and right-to-left shunt severity by transcranial Doppler in the CODICIA study","volume":"40","author":"Wessler","year":"2015","journal-title":"Cerebrov Dis."},{"key":"B13","doi-asserted-by":"publisher","first-page":"879","DOI":"10.7863\/ultra.34.5.879","article-title":"Importance of an adequately performed valsalva maneuver for detecting a right-to-left shunt indicating foramen ovale reopening","volume":"34","author":"Wei","year":"2015","journal-title":"J Ultras Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1476-7120-12-16","article-title":"Transcranial doppler ultrasonography should it be the first choice for persistent foramen ovale screening?","volume":"12","author":"Komar","year":"2014","journal-title":"Cardiovasc Ultrasound."},{"key":"B15","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1002\/jum.15724","article-title":"The prevalence of microembolic signals in transcranial Doppler sonography with bubble test in acute ischemic stroke","volume":"41","author":"Cho","year":"2022","journal-title":"J Ultrasound Med."},{"key":"B16","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1111\/j.1552-6569.2007.00218.x","article-title":"Detection of right-to-left shunts: comparison between the international consensus and spencer logarithmic scale criteria","volume":"18","author":"Lao","year":"2008","journal-title":"J Neuroimag."},{"key":"B17","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.jstrokecerebrovasdis.2008.12.001","article-title":"Transcranial Doppler and transesophageal echocardiography: comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection","volume":"18","author":"Caputi","year":"2009","journal-title":"J Stroke Cerebrov Dis."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1161\/01.STR.25.6.1265","article-title":"A comparison of transesophageal echocardiography and transcranial doppler sonography with contrast medium for detection of patent foramen ovale","volume":"25","author":"Jauss","year":"1994","journal-title":"Stroke."},{"key":"B19","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1590\/S0004-282X2008000600001","article-title":"Transcranial Doppler for paTenT foramen ovale screening is there a good correlation with transesophageal echocardiography?","volume":"66","author":"Lange","year":"2008","journal-title":"Arq Neuropsiquiatr."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1016\/0002-9149(91)90285-S","article-title":"Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts","volume":"68","author":"Nemec","year":"1991","journal-title":"Am J Cardiol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1111\/j.1540-8175.2008.00852.x","article-title":"Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine","volume":"26","author":"Zito","year":"2009","journal-title":"Echocardiography."},{"key":"B22","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1212\/WNL.44.9.1603","article-title":"Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale Experiences with 111 patients","volume":"44","author":"Kl\u00f6tzsch","year":"1994","journal-title":"Neurology."},{"key":"B23","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1177\/8756479318816983","article-title":"Comparison of transthoracic echocardiography, transesophageal echocardiography, and transcranial Doppler in the detection of patent foramen ovale as the etiology for cryptogenic stroke","volume":"35","author":"Stafford","year":"2019","journal-title":"J Diagnostic Med Sonogr."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1016\/S0301-5629(97)00077-X","article-title":"Technical limits in transcranial Doppler recording: inadequate acoustic windows","volume":"23","author":"Marinoni","year":"1997","journal-title":"Ultrasound Med Biol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1016\/j.cjca.2015.12.009","article-title":"Transcranial Doppler is complementary to echocardiography for detection and risk stratification of patent foramen ovale","volume":"32","author":"Tobe","year":"2016","journal-title":"Canadian J Cardiol"},{"key":"B26","doi-asserted-by":"publisher","first-page":"2842","DOI":"10.1161\/STROKEAHA.123.043380","article-title":"Robot-assisted transcranial Doppler versus transthoracic echocardiography for right to left shunt detection","volume":"54","author":"Rubin","year":"2023","journal-title":"Stroke."},{"key":"B27","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.echo.2005.09.023","volume":"19","year":"2006","journal-title":"J Am Soc Echocardiogr."},{"key":"B28","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1161\/01.STR.24.1.35","article-title":"Classification of subtype of acute ischemic stroke definitions for use in a multicenter clinical trial","volume":"24","author":"Adams","year":"1993","journal-title":"Stroke."},{"key":"B29","doi-asserted-by":"publisher","first-page":"3119","DOI":"10.1161\/STROKEAHA.120.029350","article-title":"Risk of paradoxical embolism (RoPE)-estimated attributable fraction correlates with the benefit of patent foramen ovale closure: an analysis of 3 trials","volume":"51","author":"Kent","year":"2020","journal-title":"Stroke."},{"key":"B30","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1212\/WNL.0b013e3182a08d59","article-title":"An index to identify stroke-related vs incidental patent foramen ovale in cryptogenic stroke","volume":"81","author":"Kent","year":"2013","journal-title":"Neurology."},{"key":"B31","article-title":"All PFO are right-left shunts, but not all right-left shunts are PFO: a case study","author":"Chang","year":"2022","journal-title":"Neurocritical Care Society Meeting"},{"key":"B32","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1111\/j.1552-6569.2007.00117.x","article-title":"Suitability of temporal bone acoustic window: conventional TCD versus transcranial color-coded duplex sonography","volume":"17","author":"Krejza","year":"2007","journal-title":"J Neuroimag."},{"key":"B33","doi-asserted-by":"publisher","first-page":"27","DOI":"10.31728\/jnn.2021.00110","article-title":"Fully automated transcranial Doppler ultrasound for middle cerebral artery insonation","volume":"14","author":"O'Brien","year":"2022","journal-title":"J Neurosonol Neuroimag."},{"key":"B34","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1016\/0301-5629(96)00032-4","article-title":"Effect of transcranial Doppler intensity on successful recording in Japanese patients","volume":"22","author":"Yagita","year":"1996","journal-title":"Ultrasound Med Biol."},{"key":"B35","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1016\/j.ultrasmedbio.2007.11.022","article-title":"Inadequate acoustical temporal bone window in patients with a transient ischemic attack or minor stroke: role of skull thickness and bone density","volume":"34","author":"Wijnhoud","year":"2008","journal-title":"Ultrasound Med Biol."},{"key":"B36","doi-asserted-by":"publisher","first-page":"3419","DOI":"10.1161\/STROKEAHA.121.034451","article-title":"Patent foramen ovale closure decreases the incidence but not the size of new brain infarction on magnetic resonance imaging: an analysis of the REDUCE trial","volume":"52","author":"Mess\u00e9","year":"2021","journal-title":"Stroke."},{"key":"B37","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1056\/NEJMoa1610057","article-title":"Long-term outcomes of patent foramen ovale closure or medical therapy after stroke","volume":"377","author":"Saver","year":"2017","journal-title":"New Engl J Med."},{"key":"B38","doi-asserted-by":"publisher","first-page":"22","DOI":"10.31728\/jnn.2019.00042","article-title":"Patent foramen ovale: risk factors and diagnostic comparison of transcranial Doppler versus echocardiography for secondary stroke prevention","volume":"11","author":"Malhotra","year":"2019","journal-title":"J Neurosonol Neuroimag."},{"key":"B39","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1136\/thx.2007.087452","article-title":"Primary determinants of ischaemic stroke\/brain abscess risks are independent of severity of pulmonary arteriovenous malformations in hereditary haemorrhagic telangiectasia","volume":"63","author":"Shovlin","year":"2008","journal-title":"Thorax."},{"key":"B40","doi-asserted-by":"publisher","first-page":"383","DOI":"10.4330\/wjc.v8.i7.383","article-title":"Transcranial Doppler ultrasonography: from methodology to major clinical applications","volume":"8","author":"D'Andrea","year":"2016","journal-title":"World J Cardiol."}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2024.1481817\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T13:25:46Z","timestamp":1739453146000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2024.1481817\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,13]]},"references-count":40,"alternative-id":["10.3389\/fneur.2024.1481817"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2024.1481817","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,13]]},"article-number":"1481817"}}