{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:57:11Z","timestamp":1793199431337,"version":"4.5.0"},"reference-count":58,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>The Voxel-based Specific Regional Analysis System for Alzheimer\u2019s Disease (VSRAD), a voxel-based morphometry tool quantifying medial temporal lobe atrophy as region-specific <jats:italic>Z<\/jats:italic>-scores, is widely used in clinical practice for detection of Alzheimer\u2019s disease (AD). However, it typically require high-resolution 3D T1-weighted MRI, which is often difficult to acquire in elderly or cognitively impaired patients. This study aimed to evaluate whether 3D volumes generated by SynthSR from 2D T1-weighted MRI can yield volumetric and VSRAD-derived indices that are comparable to those from standard 3D images, by assessing agreement, rank consistency, and diagnostic performance.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In this retrospective single-center study, MRI data from 75 patients were analyzed using both standard 3D T1-weighted images and SynthSR-generated 3D volumes reconstructed from 2D T1-weighted sequences. Regional brain volumes and four key Z-score indices from VSRAD were compared using Wilcoxon signed-rank tests with Bonferroni correction, robust Bland\u2013Altman analysis, Spearman\u2019s rank correlation, and receiver operating characteristic (ROC) curve analysis focusing on Score 1 \u201cSeverity.\u201d<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>All Z-score indices and segmented volumes showed significant absolute differences between the two methods (<jats:italic>p<\/jats:italic>\u202f&amp;lt;\u202f0.0071), with SynthSR-based data generally yielding larger volume estimates. Despite these differences, Spearman\u2019s <jats:italic>\u03c1<\/jats:italic> remained consistently high (<jats:italic>\u03c1<\/jats:italic>\u202f&amp;gt;\u202f0.7) for brain volume and Score 3 \u201cRatio,\u201d and other clinically relevant indices also demonstrated moderate correlations. ROC analysis demonstrated high value of the area under the curve (AUC) values for both standard 3D volumes (0.90) and SynthSR-generated 3D volumes (0.96), with no statistically significant difference between the two methods (<jats:italic>Z<\/jats:italic>\u202f=\u202f0.009, <jats:italic>p<\/jats:italic>\u202f=\u202f0.99, DeLong\u2019s test).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Although SynthSR-based images produced systematically different absolute values, they preserved rank-order correlations and maintained diagnostic performance comparable to that of standard 3D volumes in VSRAD analysis. Considering that conventional 3D acquisitions are often difficult to obtain in elderly patients undergoing dementia screening, SynthSR-based reconstruction may represent a practical alternative in routine clinical practice, particularly for Score 1 \u201cSeverity,\u201d the most clinically relevant marker of hippocampal atrophy.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fneur.2025.1645891","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T04:17:09Z","timestamp":1760588229000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["SynthSR-generated 3D T1-weighted MRI from routine 2D clinical images: Validation for VSRAD analysis"],"prefix":"10.3389","volume":"16","author":[{"given":"Tsukasa","family":"Koike","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akio","family":"Morita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuro","family":"Sekine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuya","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Tsuchiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsumi","family":"Takenobu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Teraoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,10,16]]},"reference":[{"key":"ref1","volume-title":"World Alzheimer report 2023: The global impact of dementia","year":"2023"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"a006239","DOI":"10.1101\/cshperspect.a006239","article-title":"Epidemiology of Alzheimer disease","volume":"2","author":"Mayeux","year":"2012","journal-title":"Cold Spring Harb Perspect Med"},{"key":"ref3","article-title":"Ageing and health","year":"2024"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"2964","DOI":"10.1001\/archinte.160.19.2964","article-title":"The detection of dementia in the primary care setting","volume":"160","author":"Valcour","year":"2000","journal-title":"Arch Intern Med"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1016\/S0140-6736(06)68542-5","article-title":"Mild cognitive impairment","volume":"367","author":"Gauthier","year":"2006","journal-title":"Lancet"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1038\/nrneurol.2011.2","article-title":"Epidemiology of Alzheimer disease","volume":"7","author":"Reitz","year":"2011","journal-title":"Nat Rev Neurol"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1985","DOI":"10.1001\/archneur.58.12.1985","article-title":"Current concepts in mild cognitive impairment","volume":"58","author":"Petersen","year":"2001","journal-title":"Arch Neurol"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1001\/archneurol.2009.266","article-title":"Mild cognitive impairment: ten years later","volume":"66","author":"Petersen","year":"2009","journal-title":"Arch Neurol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.arr.2016.01.003","article-title":"MRI morphometry in Alzheimer's disease","volume":"30","author":"Matsuda","year":"2016","journal-title":"Ageing Res Rev"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.3174\/ajnr.A2935","article-title":"Automatic voxel-based morphometry of structural MRI by SPM8 plus diffeomorphic anatomic registration through exponentiated lie algebra improves the diagnosis of probable Alzheimer disease","volume":"33","author":"Matsuda","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"731","DOI":"10.3174\/ajnr.A0398","article-title":"Automated discrimination between very early Alzheimer disease and controls using an easy Z-score imaging system for multicenter brain perfusion single-photon emission tomography","volume":"28","author":"Matsuda","year":"2007","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1111\/j.1440-1819.2010.02085.x","article-title":"Correlations between Z-scores of VSRAD and regional cerebral blood flow of SPECT in patients with Alzheimer's disease and mild cognitive impairment","volume":"64","author":"Li","year":"2010","journal-title":"Psychiatry Clin Neurosci"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1016\/j.neuroimage.2012.01.021","article-title":"FreeSurfer","volume":"62","author":"Fischl","year":"2012","journal-title":"NeuroImage"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"118206","DOI":"10.1016\/j.neuroimage.2021.118206","article-title":"Joint super-resolution and synthesis of 1 mm isotropic MP-RAGE volumes from clinical MRI exams with scans of different orientation, resolution and contrast","volume":"237","author":"Iglesias","year":"2021","journal-title":"NeuroImage"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"3607","DOI":"10.1126\/sciadv.add3607","article-title":"SynthSR: a public AI tool to turn heterogeneous clinical brain scans into high-resolution T1WI for 3D morphometry","volume":"9","author":"Iglesias","year":"2023","journal-title":"Sci Adv"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"18358","DOI":"10.1038\/s41598-023-45193-1","article-title":"Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images","volume":"13","author":"Islam","year":"2023","journal-title":"Sci Rep"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"2747","DOI":"10.1038\/s41467-024-45514-3","article-title":"Portable, low-field MRI for evaluation of Alzheimer\u2019s disease","volume":"15","author":"Sorby-Adams","year":"2024","journal-title":"Nat Commun"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"1273906","DOI":"10.3389\/fneur.2024.1273906","article-title":"Bridging the gap: improving correspondence between low-field and high-field MR images in young people","volume":"15","author":"Cooper","year":"2024","journal-title":"Front Neurol"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"e70013","DOI":"10.1111\/jon.70013","article-title":"Utilizing quantitative analysis of CSF volume from clinical T1-weighted MRI to predict thrombectomy outcomes","volume":"35","author":"Kawas","year":"2025","journal-title":"J Neuroimaging"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1155\/2000\/421719","article-title":"Stereotaxic display of brain lesions","volume":"12","author":"Rorden","year":"2000","journal-title":"Behav Neurol"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","article-title":"3D slicer as an image computing platform for the quantitative imaging network","volume":"30","author":"Fedorov","year":"2012","journal-title":"Magn Reson Imaging"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.neuroimage.2007.07.007","article-title":"A fast diffeomorphic image registration algorithm","volume":"38","author":"Ashburner","year":"2007","journal-title":"NeuroImage"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"2216","DOI":"10.1016\/j.neuroimage.2009.10.066","article-title":"Intra- and interscanner variability of automated voxel-based volumetry based on a 3D probabilistic atlas of human cerebral structures","volume":"49","author":"Huppertz","year":"2010","journal-title":"NeuroImage"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"755","DOI":"10.14336\/AD.2017.0818","article-title":"Voxel-based specific regional analysis system for Alzheimer's disease (VSRAD) on 3-tesla normal database: diagnostic accuracy in two independent cohorts with early Alzheimer's disease","volume":"9","author":"Sone","year":"2018","journal-title":"Aging Dis"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1007\/s00259-004-1490-8","article-title":"Effects of partial volume correction on discrimination between very early Alzheimer's dementia and controls using brain perfusion SPECT","volume":"31","author":"Kanetaka","year":"2004","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"377","DOI":"10.2147\/IJGM.S18866","article-title":"Diagnosis of depression by MRI scans with the use of VSRAD - a promising auxiliary means of diagnosis: a report of 10 years research","volume":"4","author":"Niida","year":"2011","journal-title":"Int J Gen Med"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"2715","DOI":"10.2147\/NDT.S222966","article-title":"Differentiation between dementia with Lewy bodies and Alzheimer's disease using voxel-based morphometry of structural MRI: a multicenter study","volume":"15","author":"Matsuda","year":"2019","journal-title":"Neuropsychiatr Dis Treat"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"300060520917270","DOI":"10.1177\/0300060520917270","article-title":"Utility of VSRAD for diagnosing Alzheimer's disease in patients screened for dementia","volume":"48","author":"Oshikubo","year":"2020","journal-title":"J Int Med Res"},{"key":"ref29","volume-title":"R: A language and environment for statistical computing","year":"2024"},{"key":"ref30","volume-title":"RStudio: integrated development for R","year":"2024"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1093\/biomet\/52.3-4.591","article-title":"An analysis of variance test for normality (complete samples)","volume":"52","author":"Shapiro","year":"1965","journal-title":"Biometrika"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"80","DOI":"10.2307\/3001968","article-title":"Individual comparisons by ranking methods","volume":"1","author":"Wilcoxon","year":"1945","journal-title":"Biom Bull"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1080\/01621459.1961.10482090","article-title":"Multiple comparisons among means","volume":"56","author":"Dunn","year":"1961","journal-title":"J Am Stat Assoc"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1002\/sim.2993","article-title":"Why Bland\u2013Altman plots should use X, not (Y+X)\/2 when X is a reference method","volume":"27","author":"Krouwer","year":"2008","journal-title":"Stat Med"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1046\/j.1440-1681.2002.03686.x","article-title":"Statistical techniques for comparing measurers and methods of measurement: a critical review","volume":"29","author":"Ludbrook","year":"2002","journal-title":"Clin Exp Pharmacol Physiol"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"72","DOI":"10.2307\/1412159","article-title":"The proof and measurement of association between two things","volume":"15","author":"Spearman","year":"1904","journal-title":"Am J Psychol"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"1285","DOI":"10.1126\/science.3287615","article-title":"Measuring the accuracy of diagnostic systems","volume":"240","author":"Swets","year":"1988","journal-title":"Science"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1148\/radiology.143.1.7063747","article-title":"The meaning and use of the area under a receiver operating characteristic (ROC) curve","volume":"143","author":"Hanley","year":"1982","journal-title":"Radiology"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3","article-title":"Index for rating diagnostic tests","volume":"3","author":"Youden","year":"1950","journal-title":"Cancer"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"837","DOI":"10.2307\/2531595","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong","year":"1988","journal-title":"Biometrics"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.neulet.2005.03.038","article-title":"Voxel-based morphometry to discriminate early Alzheimer's disease from controls","volume":"382","author":"Hirata","year":"2005","journal-title":"Neurosci Lett"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s11682-012-9203-2","article-title":"Voxel-based morphometry of brain MRI in normal aging and Alzheimer's disease","volume":"4","author":"Matsuda","year":"2013","journal-title":"Aging Dis"},{"key":"ref44","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1212\/WNL.0b013e3181c3f293","article-title":"Age, Alzheimer disease, and brain structure","volume":"73","author":"Raji","year":"2009","journal-title":"Neurology"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"1676","DOI":"10.1093\/cercor\/bhi044","article-title":"Regional brain changes in aging healthy adults: general trends, individual differences and modifiers","volume":"15","author":"Raz","year":"2005","journal-title":"Cereb Cortex"},{"key":"ref46","doi-asserted-by":"publisher","first-page":"e70027","DOI":"10.1002\/hbm.70027","article-title":"Comparing automated subcortical volume estimation methods; amygdala volumes estimated by FSL and FreeSurfer have poor consistency","volume":"45","author":"Sadil","year":"2024","journal-title":"Hum Brain Mapp"},{"key":"ref47","doi-asserted-by":"publisher","first-page":"e0247427","DOI":"10.1371\/journal.pone.0247427","article-title":"The combination of MMSE with VSRAD and eZIS has greater accuracy for discriminating mild cognitive impairment from early Alzheimer's disease than MMSE alone","volume":"16","author":"Tokumitsu","year":"2021","journal-title":"PLoS One"},{"key":"ref48","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1006\/nimg.2002.1076","article-title":"Motion artifact in magnetic resonance imaging: implications for automated analysis","volume":"16","author":"Blumenthal","year":"2002","journal-title":"NeuroImage"},{"key":"ref49","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1016\/j.mri.2004.08.012","article-title":"Geometric distortion in clinical MRI systems part I: evaluation using a 3D phantom","volume":"22","author":"Wang","year":"2004","journal-title":"Magn Reson Imaging"},{"key":"ref50","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s00234-023-03264-0","article-title":"Automatic estimation of brain parenchymal fraction in patients with multiple sclerosis: a comparison between synthetic MRI and an established automated brain segmentation software based on FSL","volume":"66","author":"Yazici","year":"2024","journal-title":"Neuroradiology"},{"key":"ref51","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1007\/s00330-018-5710-x","article-title":"Repeatability and reproducibility of FreeSurfer, FSL-SIENAX and SPM brain volumetric measurements and the effect of lesion filling in multiple sclerosis","volume":"29","author":"Guo","year":"2019","journal-title":"Eur Radiol"},{"key":"ref52","doi-asserted-by":"publisher","first-page":"102434","DOI":"10.1016\/j.mex.2024.102434","article-title":"Crop filling: a pipeline for repairing memory clinic MRI corrupted by partial brain coverage","volume":"11","author":"Leal","year":"2024","journal-title":"MethodsX"},{"key":"ref53","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1162\/imag_a_00446","article-title":"FastSurfer-LIT: lesion inpainting tool for whole-brain MRI segmentation with tumors, cavities and abnormalities","volume":"3","author":"Pollak","year":"2025","journal-title":"Imaging Neurosci"},{"key":"ref54","doi-asserted-by":"publisher","DOI":"10.1101\/2025.03.15.24320738","article-title":"Cortical lesion expansion in chronic traumatic brain injury","author":"Freeman","year":"2025","journal-title":"medRxiv"},{"key":"ref55","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.3233\/JAD-132786","article-title":"Utility of SPM8 plus DARTEL (VSRAD) combined with magnetic resonance spectroscopy as adjunct techniques for screening and predicting dementia due to Alzheimer's disease in clinical practice","volume":"41","author":"Waragai","year":"2014","journal-title":"J Alzheimer's Dis"},{"key":"ref56","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.6009\/jjrt.2021_JSRT_77.12.1411","article-title":"Accuracy of VSRAD analysis using scout images: comparison with conventional 3D-T1","volume":"77","author":"Katayama","year":"2021","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"ref57","doi-asserted-by":"publisher","first-page":"mp.2023-0093","DOI":"10.2463\/mrms.mp.2023-0093","article-title":"Voxel-based morphometry of Alzheimer's disease using a localizer image: a comparative study with magnetization prepared rapid acquisition with gradient echo","author":"Inui","year":"2024","journal-title":"Magn Reson Med Sci"},{"key":"ref58","doi-asserted-by":"publisher","first-page":"mp.2024-0003","DOI":"10.2463\/mrms.mp.2024-0003","article-title":"Voxel-based morphometry of progressive supranuclear palsy using a 3D fast low-angle shot localizer image: a comparison with magnetization-prepared rapid gradient echo","author":"Shang","year":"2024","journal-title":"Magn Reson Med Sci"}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2025.1645891\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T04:17:10Z","timestamp":1760588230000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2025.1645891\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,16]]},"references-count":58,"alternative-id":["10.3389\/fneur.2025.1645891"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2025.1645891","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,16]]},"article-number":"1645891"}}