{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T17:27:49Z","timestamp":1793899669364,"version":"4.8.0"},"reference-count":34,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100016275","name":"Seoul National University Bundang Hospital","doi-asserted-by":"publisher","award":["02-2024-0032"],"award-info":[{"award-number":["02-2024-0032"]}],"id":[{"id":"10.13039\/100016275","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:sec>\n                    <jats:title>Background and purpose<\/jats:title>\n                    <jats:p>To evaluate the effect of artificial intelligence (AI) assistance on the diagnostic performance of human readers for detecting challenging acute ischemic stroke (AIS) lesions on diffusion-weighted MRI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective, single-center, randomized crossover study included 3,986 patients (mean age, 68 \u00b1 14 years; 2,383 men) who underwent initial and follow-up diffusion-weighted imaging (DWI) between February 2017 and November 2021. From this cohort, 250 cases (130 challenging AIS, 120 controls) were selected for a multi-reader performance study. Five readers interpreted cases with and without AI assistance. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and Dice similarity coefficient (DSC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      AI achieved a sensitivity of 96.0% and identified 79.6% (43 of 54) of false-negative stroke cases from clinical reports. AI-assisted reading significantly improved AUC from 0.85 (95% CI: 0.82\u20130.90) to 0.93 (95% CI: 0.90\u20130.95;\n                      <jats:italic>p<\/jats:italic>\n                      &amp;lt; 0.01), pooled sensitivity from 74.6% (95% CI: 69.8\u201379.4) to 90.6% (95% CI: 87.4\u201393.7;\n                      <jats:italic>p<\/jats:italic>\n                      &amp;lt; 0.01), and lesion segmentation accuracy (DSC) from 0.523 to 0.742 (\n                      <jats:italic>p<\/jats:italic>\n                      &amp;lt; 0.01). Specificity slightly decreased from 88.8% (95% CI: 85.1\u201392.3) to 84.0% (95% CI: 78.5\u201389.5;\n                      <jats:italic>p<\/jats:italic>\n                      = 0.05). Reader confidence also improved with AI support, especially in challenging cases.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>AI assistance significantly improved diagnostic performance and lesion segmentation accuracy in detecting small and hyperacute AIS lesions on DWI.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fneur.2026.1766199","type":"journal-article","created":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T04:44:04Z","timestamp":1779338644000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Artificial intelligence\u2013assisted detection of challenging ischemic stroke on diffusion-weighted imaging: a reader study"],"prefix":"10.3389","volume":"17","author":[{"given":"Younbeom","family":"Jeong","sequence":"first","affiliation":[{"name":"Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine","place":["Seongnam, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wi-Sun","family":"Ryu","sequence":"additional","affiliation":[{"name":"Artificial Intelligence Research Center, JLK Inc.","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beom Joon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Neurology, Seoul National University Bundang Hospital, Seoul National University College of Medicine","place":["Seongnam, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung Se","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine","place":["Seongnam, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae Hyoung","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine","place":["Seongnam, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonard","family":"Sunwoo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine","place":["Seongnam, Republic of Korea"]},{"name":"Center for Artificial Intelligence in Healthcare, Seoul National University Bundang Hospital","place":["Seongnam, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,5,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1148\/radiology.210.1.r99ja02155","article-title":"Diffusion-weighted MR imaging: diagnostic accuracy in patients imaged within 6 hours of stroke symptom onset","volume":"210","author":"Gonz\u00e1lez","year":"1999","journal-title":"Radiology."},{"key":"B2","doi-asserted-by":"publisher","first-page":"2206","DOI":"10.1161\/01.STR.0000026864.20339.CB","article-title":"CT and diffusion-weighted MR imaging in randomized order: diffusion-weighted imaging results in higher accuracy and lower interrater variability in the diagnosis of hyperacute ischemic stroke","volume":"33","author":"Fiebach","year":"2002","journal-title":"Stroke."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1161\/STROKEAHA.111.000527","article-title":"Accuracy of diffusion-weighted imaging in the diagnosis of stroke in patients with suspected cerebral infarct","volume":"44","author":"Brunser","year":"2013","journal-title":"Stroke."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1715","DOI":"10.1161\/01.STR.29.8.1715","article-title":"A new method to improve in-bore middle cerebral artery occlusion in rats: demonstration with diffusion- and perfusion-weighted imaging","volume":"29","author":"Li","year":"1998","journal-title":"Stroke."},{"key":"B5","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1212\/WNL.45.1.172","article-title":"Multislice diffusion mapping for 3-D evolution of cerebral ischemia in a rat stroke model","volume":"45","author":"Reith","year":"1995","journal-title":"Neurology."},{"key":"B6","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1097\/RCT.0000000000000095","article-title":"False-negative diffusion-weighted imaging in acute stroke and its frequency in anterior and posterior circulation ischemia","volume":"38","author":"Bulut","year":"2014","journal-title":"J Comput Assist Tomogr."},{"key":"B7","first-page":"1434","article-title":"False-negative diffusion-weighted MR findings in acute ischemic stroke","volume":"21","author":"Oppenheim","year":"2000","journal-title":"AJNR Am J Neuroradiol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1161\/STROKEAHA.114.007107","article-title":"Sensitivity of diffusion- and perfusion-weighted imaging for diagnosing acute ischemic stroke is 975%","volume":"46","author":"Simonsen","year":"2015","journal-title":"Stroke"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1898","DOI":"10.1161\/STROKEAHA.107.497453","article-title":"When to expect negative diffusion-weighted images in stroke and transient ischemic attack","volume":"39","author":"Sylaja","year":"2008","journal-title":"Stroke."},{"key":"B10","doi-asserted-by":"publisher","first-page":"3142","DOI":"10.1161\/STROKEAHA.115.010665","article-title":"Clinically confirmed stroke with negative diffusion-weighted imaging magnetic resonance imaging: longitudinal study of clinical outcomes, stroke recurrence, and systematic review","volume":"46","author":"Makin","year":"2015","journal-title":"Stroke."},{"key":"B11","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1177\/23969873231219416","article-title":"European Stroke Organisation (ESO) guideline on cerebral small vessel disease, part 2: lacunar ischaemic stroke","volume":"9","author":"Wardlaw","year":"2024","journal-title":"Eur Stroke J."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1468","DOI":"10.1212\/WNL.0000000000003814","article-title":"Misdiagnosis of cerebrovascular events in the era of modern neuroimaging: a meta-analysis","volume":"88","author":"Tarnutzer","year":"2017","journal-title":"Neurology."},{"key":"B13","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1197\/j.aem.2006.06.060","article-title":"Pitfalls in the diagnosis of cerebellar infarction","volume":"14","author":"Savitz","year":"2007","journal-title":"Acad Emerg Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1161\/STROKEAHA.113.004411","article-title":"Poor long-term functional outcome after stroke among adults aged 18 to 50 years: follow-up of transient ischemic attack and stroke patients and unelucidated risk factor evaluation (FUTURE) study","volume":"45","author":"Synhaeve","year":"2014","journal-title":"Stroke."},{"key":"B15","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1002\/ana.24532","article-title":"Missed stroke in acute vertigo and dizziness: it is time for action, not debate","volume":"79","author":"Newman-Toker","year":"2015","journal-title":"Ann Neurol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"425","DOI":"10.5853\/jos.2023.02145","article-title":"Acute infarct segmentation on diffusion-weighted imaging using deep learning algorithm and RAPID MRI","volume":"25","author":"Ryu","year":"2023","journal-title":"J Stroke."},{"key":"B17","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.neurad.2020.03.002","article-title":"Diffusion-weighted imaging infarct volume measurement tools show discrepancies leading to diverging thrombectomy decisions","volume":"48","author":"Khoury","year":"2021","journal-title":"J Neuroradiol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1038\/s41746-021-00385-9","article-title":"Do as AI say: susceptibility in deployment of clinical decision-aids","volume":"4","author":"Gaube","year":"2021","journal-title":"NPJ Digit Med."},{"key":"B19","doi-asserted-by":"publisher","first-page":"e222976","DOI":"10.1148\/radiol.222976","article-title":"Effect of human-AI interaction on detection of malignant lung nodules on chest radiographs","volume":"307","author":"Lee","year":"2023","journal-title":"Radiology."},{"key":"B20","doi-asserted-by":"publisher","first-page":"2976","DOI":"10.1161\/STROKEAHA.122.039212","article-title":"CRCS-K Investigators","volume":"53","author":"Bae","year":"2022"},{"key":"B21","doi-asserted-by":"publisher","first-page":"113160K","DOI":"10.1117\/12.2549075","article-title":"Multi-reader multi-case analysis of variance software for diagnostic performance comparison of imaging modalities","volume":"11316","author":"Smith","year":"2020","journal-title":"Proc SPIE Int Soc Opt Eng."},{"key":"B22","doi-asserted-by":"publisher","first-page":"e271","DOI":"10.1016\/S2589-7500(19)30123-2","article-title":"A comparison of deep learning performance against health-care professionals in detecting diseases from medical imaging: a systematic review and meta-analysis","volume":"1","author":"Liu","year":"2019","journal-title":"Lancet Digit Health."},{"key":"B23","doi-asserted-by":"publisher","first-page":"163","DOI":"10.2214\/AJR.11.7444","article-title":"T2 hyperintensity of medial lemniscus is an indicator of small-vessel disease","volume":"199","author":"Erbay","year":"2012","journal-title":"AJR Am J Roentgenol."},{"key":"B24","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1186\/s40644-023-00643-x","article-title":"Breast cancer detection accuracy of AI in an entire screening population: a retrospective, multicentre study","volume":"23","author":"Elhakim","year":"2023","journal-title":"Cancer Imaging."},{"key":"B25","doi-asserted-by":"publisher","first-page":"2003061","DOI":"10.1183\/13993003.03061-2020","article-title":"Development and validation of a deep learning algorithm detecting 10 common abnormalities on chest radiographs","volume":"57","author":"Nam","year":"2021","journal-title":"Eur Respir J."},{"key":"B26","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1002\/ana.410370214","article-title":"Acute human stroke studied by whole brain echo planar diffusion-weighted magnetic resonance imaging","volume":"37","author":"Warach","year":"1995","journal-title":"Ann Neurol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1161\/01.STR.29.9.1778","article-title":"Time course of ADCw changes in ischemic stroke: beyond the human eye! Stroke","volume":"29","author":"Nagesh","year":"1998"},{"key":"B28","doi-asserted-by":"publisher","first-page":"e82","DOI":"10.1161\/01.STR.0000078659.43423.0A","article-title":"Metabolic counterpart of decreased apparent diffusion coefficient during hyperacute ischemic stroke: a brain proton magnetic resonance spectroscopic imaging study","volume":"34","author":"Nicoli","year":"2003","journal-title":"Stroke."},{"key":"B29","doi-asserted-by":"publisher","first-page":"1946","DOI":"10.1212\/WNL.0b013e3181e396d1","article-title":"Diffusion-weighted MRI in acute stroke within the first 6 hours: 15 or 30 Tesla?","volume":"74","author":"Rosso","year":"2010","journal-title":"Neurology"},{"key":"B30","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1002\/ana.410420206","article-title":"Ischemic lesion volumes in acute stroke by diffusion-weighted magnetic resonance imaging correlate with clinical outcome","volume":"42","author":"Baird","year":"1997","journal-title":"Ann Neurol."},{"key":"B31","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1038\/s41591-018-0300-7","article-title":"High-performance medicine: the convergence of human and artificial intelligence","volume":"25","author":"Topol","year":"2019","journal-title":"Nat Med."},{"key":"B32","doi-asserted-by":"publisher","first-page":"e250106","DOI":"10.1001\/jamahealthforum.2025.0106","article-title":"Calibrating AI reliance\u2014a physician's superhuman dilemma","volume":"6","author":"Patil","year":"2025","journal-title":"JAMA Health Forum."},{"key":"B33","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1186\/s13244-024-01723-7","article-title":"Artificial intelligence for MRI stroke detection: a systematic review and meta-analysis","volume":"15","author":"Bojsen","year":"2024","journal-title":"Insights Imaging."},{"key":"B34","doi-asserted-by":"publisher","first-page":"113913","DOI":"10.1016\/j.asoc.2025.113913","article-title":"Heterogeneous feature selection with group structure mining in fuzzy decision systems for medical diagnosis","volume":"185","author":"Wan","year":"2025","journal-title":"Appl Soft Comput."}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2026.1766199\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T17:00:16Z","timestamp":1793898016000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2026.1766199\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,21]]},"references-count":34,"alternative-id":["10.3389\/fneur.2026.1766199"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2026.1766199","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,21]]},"article-number":"1766199"}}