{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T16:38:34Z","timestamp":1790959114864,"version":"4.1.0"},"reference-count":38,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurol."],"abstract":"<jats:p>\n                    Quantitative measurement of cerebral hemodynamics is essential for the diagnosis, management, and prognostication of cerebrovascular diseases. Transcranial Doppler (TCD), though widely used for non-invasive blood flow velocity measurement, is inherently limited by inadequate acoustic windows and significant operator dependency and provides only localized velocity information without anatomical context. To address these limitations, Dr. NEAR flow (DNF) was developed to estimate key hemodynamic parameters, including blood flow rate, relative pressure, and velocity from routinely acquired time-of-flight magnetic resonance angiography (TOF-MRA). In this single-center retrospective study, the performance of DNF was evaluated in 113 patients by directly comparing DNF-calculated velocities with time-averaged mean velocities measured by TCD across seven major cerebral arteries. Patient-specific inflow boundary conditions were defined using TCD measurements to ensure physiologically consistent comparisons. Analysis of 700 arterial-level velocity pairs demonstrated a statistically significant positive correlation between the two modalities (Pearson\u2019s correlation coefficient,\n                    <jats:italic>r<\/jats:italic>\n                    \u202f=\u202f0.74,\n                    <jats:italic>p<\/jats:italic>\n                    \u202f&amp;lt;\u202f0.0001). These results indicate that DNF offers a robust, non-invasive alternative for comprehensive cerebrovascular assessment, overcoming the procedural burdens and technical limitations associated with conventional TCD.\n                  <\/jats:p>","DOI":"10.3389\/fneur.2026.1805658","type":"journal-article","created":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T04:24:53Z","timestamp":1782966293000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of cerebral hemodynamic assessment from time-of-flight magnetic resonance angiography using a topological network-based model with Transcranial Doppler measurements"],"prefix":"10.3389","volume":"17","author":[{"given":"Wheesung","family":"Lee","sequence":"first","affiliation":[{"name":"NEAR Brain Inc.","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Ho","family":"Ahn","sequence":"additional","affiliation":[{"name":"Department of Neurology, Pusan National University Yangsan Hospital","place":["Busan, Republic of Korea"]},{"name":"Research Institute for Convergence of Biomedical Science and Technology, Pusan National University School of Medicine","place":["Busan, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Do-Eun","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Neurology, Pusan National University Yangsan Hospital","place":["Busan, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tae-Rin","family":"Lee","sequence":"additional","affiliation":[{"name":"NEAR Brain Inc.","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,2]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1161\/01.STR.25.2.309","article-title":"Relation of cerebral blood flow to motor and cognitive functions in chronic stroke patients","volume":"25","author":"Mori","year":"1994","journal-title":"Stroke"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1159\/000016074","article-title":"Relationship between cerebral blood flow and clinical outcome in acute stroke","volume":"10","author":"Rubin","year":"2000","journal-title":"Cerebrovasc Dis"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"112165","DOI":"10.1016\/j.ejrad.2025.112165","article-title":"Effects and safety of the transradial artery approach for cerebral angiography: a comparative observational study","volume":"188","author":"Xia","year":"2025","journal-title":"Eur J Radiol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1186\/s12968-015-0174-5","article-title":"4D flow cardiovascular magnetic resonance consensus statement","author":"Dyverfeldt","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1002\/ird3.95","article-title":"Clinical applications, safety profiles, and future developments of contrast agents in modern radiology: a comprehensive review","volume":"2","author":"Najjar","year":"2024","journal-title":"iRADIOLOGY"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"H350","DOI":"10.1152\/ajpheart.00107.2022","article-title":"On the use and misuse of cerebral hemodynamics terminology using transcranial Doppler ultrasound: a call for standardization","volume":"323","author":"Skow","year":"2022","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1055\/s-0032-1331812","article-title":"Transcranial Doppler ultrasound: technique and application","volume":"32","author":"Purkayastha","year":"2012","journal-title":"Semin Neurol"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/S1052-3057(98)80135-3","article-title":"The evolving role of transcranial doppler in stroke prevention and treatment","volume":"7","author":"Alexandrov","year":"1998","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.1152\/japplphysiol.00285.2014","article-title":"Cerebral blood flow velocity underestimates cerebral blood flow during modest hypercapnia and hypocapnia","volume":"117","author":"Coverdale","year":"2014","journal-title":"J Appl Physiol"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1084","DOI":"10.1152\/japplphysiol.00651.2014","article-title":"Assessment of middle cerebral artery diameter during hypocapnia and hypercapnia in humans using ultra-high-field MRI","volume":"117","author":"Verbree","year":"2014","journal-title":"J Appl Physiol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s00701-022-05467-5","article-title":"Influence of blood viscosity models and boundary conditions on the computation of hemodynamic parameters in cerebral aneurysms using computational fluid dynamics","volume":"165","author":"Yang","year":"2023","journal-title":"Acta Neurochir"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1114\/1.1467679","article-title":"Image-based computational fluid dynamics modeling in realistic arterial geometries","volume":"30","author":"Steinman","year":"2002","journal-title":"Ann Biomed Eng"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1007\/s10237-023-01772-9","article-title":"Comparison of computational fluid dynamics with transcranial Doppler ultrasound in response to physiological stimuli","volume":"23","author":"Caddy","year":"2024","journal-title":"Biomech Model Mechanobiol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"721","DOI":"10.3389\/fphys.2018.00721","article-title":"Validation of patient-specific cerebral blood flow simulation using transcranial Doppler measurements","volume":"9","author":"Groen","year":"2018","journal-title":"Front Physiol"},{"key":"ref15","volume-title":"Arterial Pulse Wave Haemodynamics","author":"Alastruey","year":"2012"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"H208","DOI":"10.1152\/ajpheart.00037.2009","article-title":"Validation of a one-dimensional model of the systemic arterial tree","volume":"297","author":"Reymond","year":"2009","journal-title":"Am J Physiol-Heart Circ Physiol"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1023\/B:ENGI.0000007980.01347.29","article-title":"One-dimensional models for blood flow in arteries","volume":"47","author":"Formaggia","year":"2003","journal-title":"J Eng Math"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1023\/B:ENGI.0000007979.32871.e2","article-title":"One-dimensional modelling of a vascular network in space-time variables","volume":"47","author":"Sherwin","year":"2003","journal-title":"J Eng Math"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1109\/TBME.2014.2364522","article-title":"An anatomically detailed arterial network model for one-dimensional computational hemodynamics","volume":"62","author":"Blanco","year":"2015","journal-title":"IEEE Trans Biomed Eng"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1002\/cnm.2622","article-title":"A global multiscale mathematical model for the human circulation with emphasis on the venous system","volume":"30","author":"M\u00fcller","year":"2014","journal-title":"Int J Numer Methods Biomed Eng"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"1794","DOI":"10.1016\/j.jbiomech.2006.07.008","article-title":"Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows","volume":"40","author":"Alastruey","year":"2007","journal-title":"J Biomech"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"e02732","DOI":"10.1002\/cnm.2732","article-title":"A benchmark study of numerical schemes for one-dimensional arterial blood flow modelling","volume":"31","author":"Boileau","year":"2015","journal-title":"Int J Numer Methods Biomed Eng"},{"key":"ref23","author":"Weber","year":"2009"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"e1006549","DOI":"10.1371\/journal.pcbi.1006549","article-title":"Simulations of blood as a suspension predicts a depth dependent hematocrit in the circulation throughout the cerebral cortex","volume":"14","author":"Hartung","year":"2018","journal-title":"PLoS Comput Biol"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"e453","DOI":"10.7717\/peerj.453","article-title":"Scikit-image: image processing in Python","volume":"2","author":"van der Walt","year":"2014","journal-title":"PeerJ"},{"key":"ref26","first-page":"226","article-title":"A density-based algorithm for discovering clusters in large spatial databases with noise","volume-title":"AAI Knowledge Discovery in Databases","author":"Ester","year":"1996"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"11","DOI":"10.25080\/TCWV9851","article-title":"Exploring network structure, dynamics, and function using NetworkX [paper 2]","volume-title":"Proceedings of the 7th Python in Science Conference","author":"Hagberg","year":"2008"},{"key":"ref28","author":"Berg","year":"2013"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1111\/jon19944129","article-title":"Angle correction in transcranial Doppler sonography","volume":"4","author":"Eicke","year":"1994","journal-title":"J Neuroimaging"},{"key":"ref30","first-page":"1743","article-title":"Importance of angle correction in the measurement of blood flow velocity with transcranial Doppler sonography","volume":"22","author":"Krejza","year":"2001","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"149","DOI":"10.3233\/BIR-1979-16303","article-title":"Rheological parameters for the viscosity viscoelasticity and thixotropy of blood1","volume":"16","author":"Thurston","year":"1979","journal-title":"Biorheology"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"073104","DOI":"10.1063\/1.4816369","article-title":"Shear thinning effects on blood flow in straight and curved tubes","volume":"25","author":"Cherry","year":"2013","journal-title":"Phys Fluids"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1016\/j.jbiomech.2004.02.030","article-title":"Numerical investigation of the non-Newtonian blood flow in a bifurcation model with a non-planar branch","volume":"37","author":"Chen","year":"2004","journal-title":"J Biomech"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s00348-015-2037-0","article-title":"Effect of non-Newtonian viscosity on the fluid-dynamic characteristics in stenotic vessels","volume":"56","author":"Huh","year":"2015","journal-title":"Exp Fluids"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1177\/0284185118824782","article-title":"Comparison of TOF-MRA and silent scan-MRA in depicting cerebral arteries in patients with Moyamoya disease","volume":"60","author":"Tomura","year":"2019","journal-title":"Acta Radiol"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding bland Altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem Med"},{"key":"ref37","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/978-1-61779-946-4_2","volume-title":"Handbook of Cerebrovascular Disease and Neurointerventional Technique","author":"Harrigan","year":"2013"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/BF00496981","article-title":"Complications of cerebral angiography","volume":"14","author":"Olivecrona","year":"1977","journal-title":"Neuroradiology"}],"container-title":["Frontiers in Neurology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2026.1805658\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T04:24:54Z","timestamp":1782966294000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fneur.2026.1805658\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,2]]},"references-count":38,"alternative-id":["10.3389\/fneur.2026.1805658"],"URL":"https:\/\/doi.org\/10.3389\/fneur.2026.1805658","relation":{},"ISSN":["1664-2295"],"issn-type":[{"value":"1664-2295","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,2]]},"article-number":"1805658"}}