{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T05:11:52Z","timestamp":1789708312570,"version":"4.0.1"},"reference-count":26,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T00:00:00Z","timestamp":1737072000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neuroimaging"],"abstract":"<jats:p>Low-field Magnetic Resonance Imaging (MRI) has the potential to provide autonomous accessible neuroimaging in remote communities, particularly in the Canadian north. Remoteness necessitates that these MRIs be built and maintained within the communities. This approach not only ensures that the MRIs remain operational but will also allow the youth from the communities to pursue technical careers at home. The first step in this vision is to establish that the technical resources needed for building MRIs are available in remote communities and to establish an educational program that will give students the required technical skills. Over the summer of 2024, a team of students working within an Aircraft Maintenance Engineering (AME) program built the hardware for a wrist-sized prototype MRI. The student team included a high school student, AME students, engineering students and a post doctoral fellow. The skills required to maintain aircraft, namely 3D printing, sheet metal work and electrical harness building, were sufficient to build a low-field MRI. The prototype built was a radio frequency (RF) encoding MRI, whose design was optimized for eventual use in space, but the techniques and procedures developed are applicable to other MRI designs. Furthermore the breadth of students from high school to the post doctoral fellow level facilitated an extremely rich learning environment for the students while they focused on the task of designing and building the prototype MRI. Educational programs around building low-field MRIs can be created at all levels.<\/jats:p>","DOI":"10.3389\/fnimg.2024.1521517","type":"journal-article","created":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T06:50:58Z","timestamp":1737096658000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Learning to build low-field MRIs for remote northern communities"],"prefix":"10.3389","volume":"3","author":[{"given":"Gordon E.","family":"Sarty","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Logi","family":"Vidarsson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keifer","family":"Corrigal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lionel","family":"Sutherland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Millie","family":"Jamieson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Micheal","family":"Hogue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haile","family":"Kassahun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Greyeyes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Teixeira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lawrence","family":"Goertzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"McEvoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Pollard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,1,17]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e4846","DOI":"10.1002\/nbm.4846","article-title":"A framework for advancing sustainable magnetic resonance imaging access in Africa","volume":"36","author":"Anazodo","year":"2023","journal-title":"NMR Biomed"},{"key":"B2","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.jmr.2019.06.005","article-title":"TRASE 1D sequence performance in imperfect B1 fields","volume":"305","author":"Bohidar","year":"2019","journal-title":"J. Magn. Reson"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.1161\/CIRCULATIONAHA.124.069187","article-title":"Clinical use of bedside portable ultra-low-field brain magnetic resonance imaging in patients on extracorporeal membrane oxygenation: results from the multicenter SAFE MRI ECMO study","volume":"150","author":"Cho","year":"2024","journal-title":"Circulation"},{"key":"B4","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1038\/s41551-020-00641-5","article-title":"A portable scanner for magnetic resonance imaging of the brain","volume":"5","author":"Cooley","year":"2021","journal-title":"Nat. Biomed. Eng"},{"key":"B5","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1016\/j.mri.2013.03.017","article-title":"B1 transmit phase gradient coil for single-axis TRASE RF encoding","volume":"31","author":"Deng","year":"2013","journal-title":"Magn. Reson. Imaging"},{"key":"B6","doi-asserted-by":"publisher","first-page":"e65","DOI":"10.1002\/jmri.26638","article-title":"Accessible magnetic resonance imaging: a review","volume":"49","author":"Geethanath","year":"2019","journal-title":"J. Magn. Reson. Imag"},{"key":"B7","doi-asserted-by":"publisher","first-page":"13147","DOI":"10.1038\/s41598-022-17472-w","article-title":"Portable magnetic resonance imaging of patients indoors, outdoors and at home","volume":"12","author":"Guallart-Naval","year":"2022","journal-title":"Sci. Rep"},{"key":"B8","doi-asserted-by":"publisher","first-page":"102896","DOI":"10.1016\/j.nicl.2021.102896","article-title":"Assessing the utility of low resolution brain imaging: treatment of infant hydrocephalus","volume":"32","author":"Harper","year":"2021","journal-title":"NeuroImage Clin"},{"key":"B9","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.lssr.2024.05.004","article-title":"Musculoskeletal perturbations of deep space radiation: assessment using a gateway MRI","volume":"42","author":"Jullienne","year":"2024","journal-title":"Life Sci. Space Res"},{"key":"B10","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1038\/s44222-023-00086-w","article-title":"Brain imaging with portable low-field MRI","volume":"1","author":"Kimberly","year":"2023","journal-title":"Nat. Rev. Bioeng"},{"key":"B11","doi-asserted-by":"publisher","first-page":"2832","DOI":"10.1161\/STROKEAHA.123.043146","article-title":"Detection of intracerebral hemorrhage using low-field, portable magnetic resonance imaging in patients with stroke","volume":"54","author":"Mazurek","year":"2023","journal-title":"Stroke"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1946","DOI":"10.1002\/mrm.27861","article-title":"The MR Cap: a single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging","volume":"82","author":"McDaniel","year":"2019","journal-title":"Magn. Reson. Med"},{"key":"B13","doi-asserted-by":"publisher","first-page":"e4917","DOI":"10.1002\/nbm.4917","article-title":"On-site construction of a point-of-care low-field MRI system in Africa","volume":"36","author":"Obungoloch","year":"2023","journal-title":"NMR Biomed"},{"key":"B14","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1002\/mrm.28396","article-title":"In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array","volume":"85","author":"O'Reilly","year":"2021","journal-title":"Magn. Reson. Med"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1212\/WNL.0000000000207074","article-title":"Future of neurology &technology: neuroimaging made accessible using low-field, portable MRI","volume":"100","author":"Parasuram","year":"2023","journal-title":"Neurology"},{"key":"B16","volume-title":"1, 5D TRASE MRI, ISMRM 2024 2nd Workshop on Accessible MRI","author":"Sarty","year":"2024"},{"key":"B17","doi-asserted-by":"publisher","first-page":"60","DOI":"10.5589\/q12-005","article-title":"Magnetic resonance imaging of astronauts on the international space station and into the solar system","volume":"58","author":"Sarty","year":"2012","journal-title":"Canadian Aeron. Space J"},{"key":"B18","article-title":"\u201cA wrist MRI for the international space station,\u201d","volume-title":"International Astronautical Federation, 65rd International Astronautical Congress","author":"Sarty","year":"2014"},{"key":"B19","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.mri.2017.10.007","article-title":"Magnetic resonance imaging with RF encoding on curved natural slices","volume":"46","author":"Sarty","year":"2018","journal-title":"Magn. Reson. Imaging"},{"key":"B20","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1002\/mrm.22188","article-title":"MRI using radiofrequency magnetic field phase gradients","volume":"63","author":"Sharp","year":"2010","journal-title":"Magn. Reson. Med"},{"key":"B21","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1002\/mrm.28992","article-title":"External Dynamic InTerference Estimation and Removal (EDITER) for low field MRI","volume":"87","author":"Srinivas","year":"2022","journal-title":"Magn. Reson. Med"},{"key":"B22","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.jmr.2018.12.015","article-title":"The twisted solenoid RF phase gradient transmit coil for TRASE imaging","volume":"299","author":"Sun","year":"2019","journal-title":"J. Magn. Reson"},{"key":"B23","author":"Vidarsson","year":"2018","journal-title":"Magnetic Resonance Imaging System and Method, United States Patent"},{"key":"B24","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1038\/d41586-023-00759-x","article-title":"Five steps to make MRI scanners more affordable to the world","volume":"615","author":"Webb","year":"2023","journal-title":"Nature"},{"key":"B25","doi-asserted-by":"publisher","first-page":"eabm3952","DOI":"10.1126\/sciadv.abm3952","article-title":"Portable, low-field magnetic resonance imaging enables highly accessible and dynamic bedside evaluation of ischemic stroke","volume":"8","author":"Yuen","year":"2022","journal-title":"Sci. Adv"},{"key":"B26","doi-asserted-by":"publisher","first-page":"eadm7168","DOI":"10.1126\/science.adm7168","article-title":"Whole-body magnetic resonance imaging at 0.05 Tesla","volume":"384","author":"Zhao","year":"2024","journal-title":"Science"}],"container-title":["Frontiers in Neuroimaging"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnimg.2024.1521517\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T06:51:01Z","timestamp":1737096661000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnimg.2024.1521517\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,17]]},"references-count":26,"alternative-id":["10.3389\/fnimg.2024.1521517"],"URL":"https:\/\/doi.org\/10.3389\/fnimg.2024.1521517","relation":{},"ISSN":["2813-1193"],"issn-type":[{"value":"2813-1193","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,17]]},"article-number":"1521517"}}