{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T16:08:13Z","timestamp":1753891693313,"version":"3.41.2"},"reference-count":20,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T00:00:00Z","timestamp":1628121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>This work aims to assess the effectiveness and safety of robotic assistance in ventriculoperitoneal shunting and to compare the results with data from traditional surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We retrospectively analyzed 60 patients who had undergone ventriculoperitoneal shunting, of which shunts were implanted using a robot in 20 patients and using traditional surgical methods in the other 40 patients. Data related to surgery were compared between the two groups, and the accuracy of the drainage tube in the robot-assisted group was assessed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In the robot-assisted surgery group, the operation duration was 29.75 \u00b1 6.38 min, intraoperative blood loss was 10.0 \u00b1 3.98 ml, the success rate of a single puncture was 100%, and the bone hole diameter was 4.0 \u00b1 0.3 mm. On the other hand, the operation duration was 48.63 \u00b1 6.60 min, intraoperative blood loss was 22.25 \u00b1 4.52 ml, the success rate of a single puncture was 77.5%, and the bone hole diameter was 11.0 \u00b1 0.2 mm in the traditional surgery group. The above are statistically different between the two groups (<jats:italic>P<\/jats:italic> &amp;lt; 0.05). Only one case of surgery-related complications occurred in the robot-assisted group, while 13 cases occurred in the traditional surgery group. There was no significant difference in the hospitalization time. In the robot-assisted surgery group, the average radial error was 2.4 \u00b1 1.5 mm and the average axial error was 1.9 \u00b1 2.1 mm.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>In summary, robot-assisted implantation is accurate, simple to operate, and practical; the duration of surgery is short; trauma to the patient is reduced; and fewer postoperative complications related to surgery are reported.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fnins.2021.685142","type":"journal-article","created":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T05:25:57Z","timestamp":1628141157000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["The Clinical Application of Robot-Assisted Ventriculoperitoneal Shunting in the Treatment of Hydrocephalus"],"prefix":"10.3389","volume":"15","author":[{"given":"De-feng","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huan-guang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fan-gang","family":"Meng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"An-chao","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian-guo","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2021,8,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.3171\/2013.7.Jns13390","article-title":"Hypertensive slit ventricle syndrome: pseudotumor cerebri with a malfunctioning shunt?","volume":"119","author":"Bateman","year":"2013","journal-title":"J. Neurosurg."},{"key":"B2","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/S1474-4422(08)70291-6","article-title":"Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson\u2019s disease.","volume":"8","author":"Benabid","year":"2009","journal-title":"Lancet Neurol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.oooo.2019.01.008","article-title":"Three-dimensional measurement and registration accuracy of a third-generation optical tracking system for navigational maxillary orthognathic surgery.","volume":"128","author":"Choi","year":"2019","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol."},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.2032","article-title":"Accuracy of the robot-assisted procedure in deep brain stimulation.","volume":"15","author":"Goia","year":"2019","journal-title":"Int. J. Med. Robot."},{"key":"B5","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/NRL.0b013e31816b73e4","article-title":"Brain injury due to ventricular shunt placement delineated by diffusion tensor imaging (DTI) tractography.","volume":"14","author":"Gold","year":"2008","journal-title":"Neurologistic"},{"key":"B6","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.wneu.2018.04.155","article-title":"Techniques for stereotactic neurosurgery: beyond the frame, toward the intraoperative magnetic resonance imaging-guided and robot-assisted approaches.","volume":"116","author":"Guo","year":"2018","journal-title":"World Neurosurg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.3171\/2010.3.JNS091237","article-title":"Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study.","volume":"113","author":"Hayhurst","year":"2010","journal-title":"J. Neurosurg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"284","DOI":"10.3171\/jns.2003.98.2.0284","article-title":"Lack of benefit of endoscopic ventriculoperitoneal shunt insertion: a multicenter randomized trial.","volume":"98","author":"Kestle","year":"2003","journal-title":"J. Neurosurg."},{"key":"B9","doi-asserted-by":"publisher","first-page":"22","DOI":"10.3171\/2011.4.PEDS10551","article-title":"A standardized protocol to reduce cerebrospinal fluid shunt infection: the hydrocephalus clinical research network quality improvement initiative.","volume":"8","author":"Kestle","year":"2011","journal-title":"J. Neurosurg. Pediatr."},{"key":"B10","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1159\/000065393","article-title":"Shunt dependency in shunted arachnoid cyst: a reason to avoid shunting.","volume":"37","author":"Kim","year":"2002","journal-title":"Pediatr. Neurosurg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1227\/NEU.0000000000000849","article-title":"Image guidance in ventricular cerebrospinal fluid shunt catheter placement: a systematic review and meta-analysis.","volume":"77","author":"Nesvick","year":"2015","journal-title":"Neurosurgery"},{"key":"B12","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1227\/00006123-199307000-00022","article-title":"Neuro-ophthalmic complications of intracranial catheters.","volume":"33","author":"Shults","year":"1993","journal-title":"Neurosurgery"},{"key":"B13","doi-asserted-by":"publisher","first-page":"479","DOI":"10.3171\/2009.6.JNS081161","article-title":"Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy.","volume":"112","author":"Starr","year":"2010","journal-title":"J. Neurosurg."},{"key":"B14","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.ncl.2020.09.008","article-title":"Update in the management of idiopathic intracranial hypertension.","volume":"39","author":"Thurtell","year":"2021","journal-title":"Neurol. Clin."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1227\/01.NEU.0000356973.39913.0B","article-title":"External ventricular drain insertion accuracy: is there a need for change in practice?","volume":"65","author":"Toma","year":"2009","journal-title":"Neurosurgery"},{"key":"B16","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1007\/s00381-009-0852-4","article-title":"Endoscopic management of brainstem injury due to ventriculoperitoneal shunt placement.","volume":"25","author":"Torrez-Corzo","year":"2009","journal-title":"Childs Nerv. Syst."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.1007\/s10439-019-02230-3","article-title":"Electrode placement accuracy in robot-assisted asleep deep brain stimulation.","volume":"47","author":"VanSickle","year":"2019","journal-title":"Ann. Biomed. Eng."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1691","DOI":"10.1007\/s00701-012-1329-x","article-title":"Evaluation of an institutional guideline for the treatment of cerebrospinal fluid shunt-associated infections.","volume":"154","author":"von der Brelie","year":"2012","journal-title":"Acta Neurochir."},{"key":"B19","doi-asserted-by":"publisher","first-page":"191","DOI":"10.3171\/2014.9.JNS14256","article-title":"In vivo measurement of the frame-based application accuracy of the Neuromate neurosurgical robot.","volume":"122","author":"von Langsdorff","year":"2015","journal-title":"J. Neurosurg."},{"key":"B20","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.jocn.2010.06.018","article-title":"Factors affecting the accuracy of ventricular catheter placement.","volume":"18","author":"Wan","year":"2011","journal-title":"J. Clin. Neurosci."}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2021.685142\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T05:25:59Z","timestamp":1628141159000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2021.685142\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,5]]},"references-count":20,"alternative-id":["10.3389\/fnins.2021.685142"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2021.685142","relation":{},"ISSN":["1662-453X"],"issn-type":[{"type":"electronic","value":"1662-453X"}],"subject":[],"published":{"date-parts":[[2021,8,5]]},"article-number":"685142"}}