{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T16:47:31Z","timestamp":1782751651189,"version":"3.54.5"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T00:00:00Z","timestamp":1643587200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To characterize the corneal and epithelial thickness at different stages of keratoconus (KC), using a deep learning based corneal segmentation algorithm for anterior segment optical coherence tomography (AS-OCT).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>An AS-OCT dataset was constructed in this study with 1,430 images from 715 eyes, which included 118 normal eyes, 134 mild KC, 239 moderate KC, 153 severe KC, and 71 scarring KC. A deep learning based corneal segmentation algorithm was applied to isolate the epithelial and corneal tissues from the background. Based on the segmentation results, the thickness of epithelial and corneal tissues was automatically measured in the center 6 mm area. One-way ANOVA and linear regression were performed in 20 equally divided zones to explore the trend of the thickness changes at different locations with the KC progression. The 95% confidence intervals (CI) of epithelial thickness and corneal thickness in a specific zone were calculated to reveal the difference of thickness distribution among different groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Our data showed that the deep learning based corneal segmentation algorithm can achieve accurate tissue segmentation and the error range of measured thickness was less than 4 \u03bcm between our method and the results from clinical experts, which is approximately one image pixel. Statistical analyses revealed significant corneal thickness differences in all the divided zones (<jats:italic>P<\/jats:italic> &amp;lt; 0.05). The entire corneal thickness grew gradually thinner with the progression of the KC, and their trends were more pronounced around the pupil center with a slight shift toward the temporal and inferior side. Especially the epithelial thicknesses were thinner gradually from a normal eye to severe KC. Due to the formation of the corneal scarring, epithelial thickness had irregular fluctuations in the scarring KC.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Our study demonstrates that our deep learning method based on AS-OCT images could accurately delineate the corneal tissues and further successfully characterize the epithelial and corneal thickness changes at different stages of the KC progression.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fnins.2021.804273","type":"journal-article","created":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T13:19:11Z","timestamp":1643635151000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Dissecting the Profile of Corneal Thickness With Keratoconus Progression Based on Anterior Segment Optical Coherence Tomography"],"prefix":"10.3389","volume":"15","author":[{"given":"Yanling","family":"Dong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongfang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ping","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuanfeng","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guotong","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lixin","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,1,31]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.preteyeres.2018.04.002","article-title":"Anterior segment optical coherence tomography.","volume":"66","author":"Ang","year":"2018","journal-title":"Prog. Retin. Eye Res."},{"key":"B2","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1111\/j.1755-3768.2010.01947.x","article-title":"Measurement of central corneal thickness by high-resolution scheimpflug imaging, fourier-domain optical coherence tomography and ultrasound pachymetry.","volume":"90","author":"Chen","year":"2012","journal-title":"Acta Ophthalmol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1752","DOI":"10.1167\/iovs.11-9033","article-title":"Precision of high definition spectral-domain optical coherence tomography for measuring central corneal thickness.","volume":"53","author":"Corre-Perez","year":"2012","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"B4","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1016\/j.ophtha.2012.08.036","article-title":"Corneal thickness in keratoconus: comparing optical, ultrasound, and optical coherence tomography pachymetry.","volume":"120","author":"Dutta","year":"2013","journal-title":"Ophthalmology"},{"key":"B5","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1167\/tvst.8.3.39","article-title":"Automatic segmentation of corneal microlayers on optical coherence tomography images.","volume":"8","author":"Elsawy","year":"2019","journal-title":"Transl. Vis. Sci. Technol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1097\/ICO.0000000000002150","article-title":"The prevalence and risk factors for keratoconus: a systematic review and meta-analysis.","volume":"39","author":"Hashemi","year":"2020","journal-title":"Cornea"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1951","DOI":"10.1016\/j.ophtha.2013.02.022","article-title":"A comparison between scheimpflug imaging and optical coherence tomography in measuring corneal thickness.","volume":"120","author":"Huang","year":"2013","journal-title":"Ophthalmology"},{"key":"B8","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.compbiomed.2019.04.024","article-title":"Computer aided diagnosis for suspect keratoconus detection.","volume":"109","author":"Issarti","year":"2019","journal-title":"Comput. Biol. Med."},{"key":"B9","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/0002-9394(86)90817-2","article-title":"A 48-Year clinical and epidemiologic study of keratoconus.","volume":"101","author":"Kennedy","year":"1986","journal-title":"Am. J. Ophthalmol."},{"key":"B10","doi-asserted-by":"publisher","first-page":"6181405","DOI":"10.1155\/2017\/6181405","article-title":"Repeatability and agreement of central corneal thickness and keratometry measurements between four different devices.","volume":"2017","author":"Kiraly","year":"2017","journal-title":"J. Ophthalmol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/s0886-3350(98)80284-8","article-title":"Live-epikeratophakia for keratoconus.","volume":"24","author":"Krumeich","year":"1998","journal-title":"J. Cataract Refract. Surg."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1524","DOI":"10.1364\/BOE.2.001524","article-title":"Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming.","volume":"2","author":"Larocca","year":"2011","journal-title":"Biomed. Opt. Express"},{"key":"B13","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","article-title":"Corneal epithelial thickness mapping by fourier-domain optical coherence tomography in normal and keratoconic eyes.","volume":"119","author":"Li","year":"2012","journal-title":"Ophthalmology"},{"key":"B14","first-page":"1579","author":"Liu","year":"2020","journal-title":"Hierarchy-Constrained Network for Corneal Tissue Segmentation Based on Anterior Segment OCT Images."},{"key":"B15","doi-asserted-by":"publisher","first-page":"23482","DOI":"10.1038\/srep23482","article-title":"Corneal epithelium thickness profile in 614 normal Chinese children aged 7\u201315 years old.","volume":"6","author":"Ma","year":"2016","journal-title":"Sci. Rep."},{"key":"B16","first-page":"1432","author":"Mathai","year":"2019","journal-title":"Learning to Segment Corneal Tissue Interfaces in OCT Images."},{"key":"B17","doi-asserted-by":"publisher","first-page":"3794","DOI":"10.1167\/iovs.19-27619","article-title":"Relations among corneal curvature, thickness, and volume in keratoconus as evaluated by anterior segment optical coherence tomography.","volume":"60","author":"Morishige","year":"2019","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"B18","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1109\/MCSE.2007.58","article-title":"Python for scientific computing.","volume":"9","author":"Oliphant","year":"2007","journal-title":"Comput. Sci. Eng."},{"key":"B19","doi-asserted-by":"publisher","first-page":"5291","DOI":"10.1364\/BOE.10.005291","article-title":"Accurate tissue interface segmentation via adversarial pre-segmentation of anterior segment OCT images.","volume":"10","author":"Ouyang","year":"2019","journal-title":"Biomed. Opt. Express"},{"key":"B20","article-title":"\u201cU-Net: Convolutional Networks for Biomedical Image Segmentation.\u201d in Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2015. MICCAI 2015","author":"Ronneberger","year":"2015"},{"key":"B21","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1364\/BOE.10.000622","article-title":"CorneaNet: fast segmentation of cornea OCT scans of healthy and keratoconic eyes using deep learning.","volume":"10","author":"Santos","year":"2019","journal-title":"Biomed. Opt. Express"},{"key":"B22","doi-asserted-by":"publisher","first-page":"146","DOI":"10.22608\/APO.201910","article-title":"Anterior segment optical coherence tomography: applications for clinical care and scientific research.","volume":"8","author":"Shan","year":"2019","journal-title":"Asia Pac. J. Ophthalmol."},{"key":"B23","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/ICO.0000000000002435","article-title":"Diagnostic value of corneal epithelial and stromal thickness distribution profiles in forme fruste keratoconus and subclinical keratoconus.","volume":"40","author":"Toprak","year":"2021","journal-title":"Cornea"},{"key":"B24","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1159\/000500313","article-title":"Comparison of corneal epithelial and stromal thickness between keratoconic and normal eyes in an Asian population.","volume":"62","author":"Wang","year":"2019","journal-title":"Ophthalmic Res."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40662-015-0011-9","article-title":"Fast segmentation of anterior segment optical coherence tomography images using graph cut.","volume":"2","author":"Williams","year":"2015","journal-title":"Eye Vis."},{"key":"B26","doi-asserted-by":"publisher","first-page":"e97962","DOI":"10.1371\/journal.pone.0097962","article-title":"Vertical and horizontal corneal epithelial thickness profile using ultra-high resolution and long scan depth optical coherence tomography.","volume":"9","author":"Wu","year":"2014","journal-title":"PLoS One"},{"key":"B27","doi-asserted-by":"publisher","first-page":"31550","DOI":"10.1038\/srep31550","article-title":"Value of corneal epithelial and Bowman\u2019s layer vertical thickness profiles generated by UHR-OCT for sub-clinical keratoconus diagnosis.","volume":"6","author":"Xu","year":"2016","journal-title":"Sci. Rep."},{"key":"B28","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1097\/j.jcrs.0000000000000498","article-title":"Keratoconus detection using OCT corneal and epithelial thickness map parameters and patterns.","volume":"47","author":"Yang","year":"2020","journal-title":"J. Cataract Refract. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1111\/cxo.12874","article-title":"Optical coherence tomography imaging in keratoconus.","volume":"102","author":"Yip","year":"2019","journal-title":"Clin. Exp. Optom."},{"key":"B30","doi-asserted-by":"publisher","first-page":"2537","DOI":"10.1097\/00004397-199803810-00020","article-title":"Baseline findings in the collaborative longitudinal evaluation of keratoconus (CLEK) study.","volume":"39","author":"Zadnik","year":"1998","journal-title":"Invest. Ophthalmol. Vis. Sci."}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2021.804273\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T13:19:17Z","timestamp":1643635157000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2021.804273\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,31]]},"references-count":30,"alternative-id":["10.3389\/fnins.2021.804273"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2021.804273","relation":{},"ISSN":["1662-453X"],"issn-type":[{"value":"1662-453X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,31]]},"article-number":"804273"}}