{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T12:53:15Z","timestamp":1794660795524,"version":"4.9.1"},"reference-count":59,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T00:00:00Z","timestamp":1756944000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007707","name":"Istituto Nazionale per l'Assicurazione Contro Gli Infortuni sul Lavoro","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007707","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:p>Upper limb amputation significantly affects daily functioning and quality of life. Although myoelectric prostheses offer a promising avenue for restoring motor capabilities, high rates of device abandonment underscore challenges in control performance and user integration. Recent advances in high-density electromyography (HD-EMG) and machine learning (ML) algorithms have shown potential to enhance prosthetic dexterity. HD-EMG interfaces capture richer spatial and temporal muscle activation data, while ML algorithms exploit this information to improve intention detection and motion control. This mini-review explores advancements in HD-EMG acquisition systems, including both interface designs and recording technologies, as well as ML algorithms leveraging spatial information. In addition to summarizing the current state of the art, we discuss the challenges and the opportunities of embedding these technologies in prosthetic systems, with the objective of facilitating the translation of laboratory research into clinical applications.<\/jats:p>","DOI":"10.3389\/fnins.2025.1655257","type":"journal-article","created":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T05:34:37Z","timestamp":1756964077000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":16,"title":["Advances in HD-EMG interfaces and spatial algorithms for upper limb prosthetic control"],"prefix":"10.3389","volume":"19","author":[{"given":"Debora","family":"Quadrelli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"Canepa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dario","family":"Di Domenico","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicol\u00f2","family":"Boccardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michela","family":"Chiappalone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Laffranchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,9,4]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"2242","DOI":"10.1109\/TBME.2013.2252346","article-title":"Design of a portable, intrinsically safe multichannel acquisition system for high-resolution, real-time processing","volume":"60","year":"2013","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B2","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1007\/s12178-020-09656-6","article-title":"Technological advances in prosthesis design and rehabilitation following upper extremity limb loss","volume":"13","author":"Bates","year":"2020","journal-title":"Curr. Rev. Musculoskelet. Med"},{"key":"B3","doi-asserted-by":"publisher","first-page":"3371","DOI":"10.1109\/TBME.2019.2904398","article-title":"A modular, smart, and wearable system for high density","volume":"66","author":"Cerone","year":"2019","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1109\/TNSRE.2021.3086860","article-title":"Design and characterization of a textile electrode system for the detection of high-density","volume":"29","author":"Cerone","year":"2021","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng"},{"key":"B5","first-page":"1","article-title":"\u201cA wireless, minaturized multi-channel sEMG acquisition system for use in dynamic tasks,\u201d","volume-title":"2017 IEEE Biomedical Circuits and Systems Conference (BioCAS)","year":"2017"},{"key":"B6","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1109\/TBCAS.2023.3314053","article-title":"Novel wearable HD-EMG sensor with shift-robust gesture recognition using deep learning","volume":"17","author":"Chamberland","year":"2023","journal-title":"IEEE Transact. Biomed. Circuits Syst"},{"key":"B7","doi-asserted-by":"publisher","first-page":"13332","DOI":"10.3390\/app132413332","article-title":"Spatial feature integration in multidimensional electromyography analysis for hand gesture recognition","volume":"13","author":"Chen","year":"","journal-title":"Appl. Sci"},{"key":"B8","doi-asserted-by":"publisher","first-page":"328","DOI":"10.3390\/biomimetics8030328","article-title":"A review of myoelectric control for prosthetic hand manipulation","volume":"8","author":"Chen","year":"","journal-title":"Biomimetics"},{"key":"B9","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3389\/fnins.2016.00209","article-title":"Literature review on needs of upper limb prosthesis users","volume":"10","author":"Cordella","year":"2016","journal-title":"Front. Neurosci"},{"key":"B10","doi-asserted-by":"publisher","first-page":"9938","DOI":"10.1109\/LRA.2024.3451388","article-title":"Long-term upper-limb prosthesis myocontrol via high-density sEMG and incremental learning","volume":"9","author":"Di Domenico","year":"2024","journal-title":"IEEE Robot. Automat. Lett"},{"key":"B11","first-page":"913","article-title":"\u201cUsing image processing techniques and HD-EMG for upper limb prosthesis gesture recognition,\u201d","volume-title":"Iberoamerican Congress on Pattern Recognition","author":"D\u00edaz-Amador","year":"2018"},{"key":"B12","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1016\/j.jelekin.2006.09.005","article-title":"Clinical applications of high-density surface EMG: a systematic review","volume":"16","author":"Drost","year":"2006","journal-title":"J. Electromyog. Kinesiol"},{"key":"B13","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1002\/mus.28304","article-title":"Electrical interference in clinical practice: a conceptual and practical approach","volume":"71","author":"Dumitru","year":"2025","journal-title":"Muscle Nerve"},{"key":"B14","doi-asserted-by":"publisher","first-page":"6863","DOI":"10.3390\/s21206863","article-title":"Biosignal-based human\u2013machine interfaces for assistance and rehabilitation: a survey","volume":"21","author":"Esposito","year":"2021","journal-title":"Sensors"},{"key":"B15","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1109\/RBME.2022.3164797","article-title":"A review of techniques for surface electromyography signal quality analysis","volume":"16","author":"Farago","year":"2023","journal-title":"IEEE Rev. Biomed. Eng"},{"key":"B16","doi-asserted-by":"publisher","first-page":"095816","DOI":"10.1146\/annurev-bioeng-110222-095816","article-title":"Integrating upper-limb prostheses with the human body: technology advances, readiness, and roles in human\u2013prosthesis interaction","volume":"26","author":"Huang","year":"2024","journal-title":"Annu. Rev. Biomed. Eng"},{"key":"B17","unstructured":"Intan Recording System RHD2000 Series\n          \n          2012"},{"key":"B18","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s40998-020-00353-1","article-title":"Adaptive myoelectric pattern recognition based on hybrid spatial features of HD-sEMG signals","volume":"45","author":"Jaber","year":"","journal-title":"Iran. J. Sci. Technol. Trans. Elect. Eng"},{"key":"B19","doi-asserted-by":"publisher","first-page":"102482","DOI":"10.1016\/j.bspc.2021.102482","article-title":"Online myoelectric pattern recognition based on hybrid spatial features","volume":"66","author":"Jaber","year":"","journal-title":"Biomed. Signal Process Control"},{"key":"B20","doi-asserted-by":"publisher","first-page":"3389","DOI":"10.1109\/TBME.2022.3170025","article-title":"Myolink: A 128-channel, 18 nV\/Hz, embedded recording system, optimized for high-density surface electromyogram acquisition","volume":"69","author":"Koutsoftidis","year":"2022","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B21","doi-asserted-by":"publisher","first-page":"58","DOI":"10.3389\/fnbot.2018.00058","article-title":"Causes of performance degradation in non-invasive electromyographic pattern recognition in upper limb prostheses","volume":"12","author":"Kyranou","year":"2018","journal-title":"Front. Neurorobot"},{"key":"B22","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1109\/TNSRE.2024.3523943","article-title":"Decoding gestures in electromyography: Spatiotemporal graph neural networks for generalizable and interpretable classification","volume":"33","author":"Lee","year":"2025","journal-title":"IEEE Trans. Neural. Syst. Rehabil. Eng"},{"key":"B23","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1038\/s41528-023-00246-3","article-title":"Stretchable array electromyography sensor with graph neural network for static and dynamic gestures recognition system","volume":"7","author":"Lee","year":"2023","journal-title":"NPJ Flexible Elect"},{"key":"B24","doi-asserted-by":"publisher","first-page":"68410","DOI":"10.1109\/ACCESS.2023.3291108","article-title":"An improved feature extraction method for surface electromyography based on muscle activity regions","volume":"11","author":"Ma","year":"2023","journal-title":"IEEE Access"},{"key":"B25","doi-asserted-by":"publisher","first-page":"acac57","DOI":"10.1088\/2516-1091\/acac57","article-title":"Active upper limb prostheses: a review on current state and upcoming breakthroughs","volume":"5","author":"Marinelli","year":"2023","journal-title":"Prog Biomed. Eng"},{"key":"B26","volume-title":"Graph Neural Networks for HD EMG-Based Movement Intention Recognition: An Initial Investigation","author":"Massa","year":"2022"},{"key":"B27","doi-asserted-by":"crossref","first-page":"4499","DOI":"10.1109\/TCE.2023.3333421","article-title":"Explainable AI-powered graph neural networks for HD EMG-based gesture intention recognition","volume":"70","author":"Massa","year":"2023","journal-title":"IEEE Trans. Consum. Electron"},{"key":"B28","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.clinbiomech.2008.08.006","article-title":"Technology and instrumentation for detection and conditioning of the surface electromyographic signal: state of the art","volume":"24","author":"Merletti","year":"2009","journal-title":"Clin. Biomech"},{"key":"B29","doi-asserted-by":"publisher","first-page":"102440","DOI":"10.1016\/j.jelekin.2020.102440","article-title":"Tutorial. surface EMG detection, conditioning and pre-processing: best practices","volume":"54","year":"2020","journal-title":"J. Electromyogr. Kinesiol"},{"key":"B30","volume-title":"Surface Electromyography: Physiology, Engineering, and Applications","year":"2016"},{"key":"B31","doi-asserted-by":"publisher","first-page":"102363","DOI":"10.1016\/j.jelekin.2019.102363","article-title":"Tutorial surface EMG detection in space and time: best practices","volume":"49","year":"2019","journal-title":"J. Electromyogr. Kinesiol"},{"key":"B32","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1038\/s41928-020-00510-8","article-title":"A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition","volume":"4","author":"Moin","year":"2021","journal-title":"Nat. Elect"},{"key":"B33","unstructured":"2023"},{"key":"B34","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.3390\/s23031113","article-title":"A novel screen-printed textile interface for high-density electromyography recording","volume":"23","author":"Murciego","year":"2023","journal-title":"Sensors"},{"key":"B35","doi-asserted-by":"publisher","first-page":"ac2a","DOI":"10.1088\/1741-2552\/ac2a8d","article-title":"A portable, self-contained neuroprosthetic hand with deep learning-based finger control","volume":"18","author":"Nguyen","year":"2021","journal-title":"J. Neural Eng"},{"key":"B36","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.bspc.2019.04.027","article-title":"Pattern recognition based on HD-sEMG spatial features extraction for an efficient proportional control of a robotic arm","volume":"53","author":"Nougarou","year":"2019","journal-title":"Biomed. Signal Proc. Cont"},{"key":"B37","doi-asserted-by":"publisher","first-page":"101881","DOI":"10.1016\/j.bspc.2020.101881","article-title":"Phasor represented EMG feature extraction against varying contraction level of prosthetic control","volume":"59","year":"2020","journal-title":"Biomed. Signal Proc. Cont"},{"key":"B38","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1007\/BF02350986","article-title":"Sixty-four channel wearable acquisition system for long-term surface electromyogram recording with electrode arrays","volume":"42","author":"Pozzo","year":"2004","journal-title":"Med. Biol. Eng. Comput"},{"key":"B39","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s40137-013-0044-8","article-title":"Prosthetic myoelectric control strategies: a clinical perspective","volume":"2","author":"Roche","year":"2014","journal-title":"Curr. Surg. Reports"},{"key":"B40","doi-asserted-by":"publisher","first-page":"4004","DOI":"10.1109\/TNSRE.2024.3490796","article-title":"HDE-array: development and validation of a new dry electrode array design to acquire HD-sEMG for hand position estimation","volume":"32","author":"Rolandino","year":"2024","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng"},{"key":"B41","unstructured":""},{"key":"B42","doi-asserted-by":"publisher","first-page":"3708","DOI":"10.1080\/09638288.2020.1866684","article-title":"Current rates of prosthetic usage in upper-limb amputees - have innovations had an impact on device acceptance?","volume":"44","author":"Salminger","year":"2022","journal-title":"Disabil Rehabil"},{"key":"B43","unstructured":"Sessantaquattro\n          \n          2024"},{"key":"B44","article-title":"High-performance hand kinematics estimation requires full bandwidth high-density EMG recordings","author":"S\u00eempetru","year":"2023","journal-title":"techrxiv [Preprint]"},{"key":"B45","doi-asserted-by":"publisher","first-page":"3118","DOI":"10.1109\/TNSRE.2023.3295060","article-title":"Proportional and simultaneous real-time control of the full human hand from high-density electromyography","volume":"31","author":"S\u00eempetru","year":"2023","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng"},{"key":"B46","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1080\/17483107.2020.1738567","article-title":"Comfort and function remain key factors in upper limb prosthetic abandonment: findings of a scoping review","volume":"16","author":"Smail","year":"2021","journal-title":"Disabil. Rehabil. Assist. Technol"},{"key":"B47","first-page":"6040","volume-title":"A Wearable Wireless Armband Sensor for High-Density Surface Electromyography Recording","author":"Tam","year":""},{"key":"B48","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1109\/TBCAS.2019.2955641","article-title":"A fully embedded adaptive real-time hand gesture classifier leveraging HD-sEMG and deep learning","volume":"14","author":"Tam","year":"","journal-title":"IEEE Trans. Biomed. Circuits Syst"},{"key":"B49","first-page":"722","volume-title":"Forearm High-Density Electromyography Data Visualization and Classification with Machine Learning for Hand Prosthesis Control","author":"Tam","year":"2020"},{"key":"B50","article-title":"Towards robust and interpretable EMG-based hand gesture recognition using deep metric meta learning","author":"Tam","year":"2024","journal-title":"arXiv [Preprint]"},{"key":"B51","unstructured":""},{"key":"B52","unstructured":""},{"key":"B53","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jelekin.2016.01.001","article-title":"iEMG: imaging electromyography","volume":"27","year":"2016","journal-title":"J. Electromyogr. Kinesiol"},{"key":"B54","doi-asserted-by":"publisher","first-page":"1810","DOI":"10.3390\/s24061810","article-title":"Design, fabrication and evaluation of a stretchable high-density electromyography array","volume":"24","author":"Varghese","year":"2024","journal-title":"Sensors"},{"key":"B55","doi-asserted-by":"publisher","first-page":"1729","DOI":"10.1007\/s13042-021-01482-7","article-title":"sEMG based hand gesture recognition with deformable convolutional network","volume":"13","author":"Wang","year":"2022","journal-title":"Int. J. Mach. Learn, Cybern"},{"key":"B56","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1109\/TNSRE.2023.3342050","article-title":"Cross-user electromyography pattern recognition based on a novel spatial-temporal graph convolutional network","volume":"32","author":"Xu","year":"2024","journal-title":"IEEE Trans. Neural Syst. Rehab. Eng"},{"key":"B57","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1109\/TBCAS.2019.2959160","article-title":"Robust real-time embedded EMG recognition framework using temporal convolutional networks on a multicore IoT processor","volume":"14","author":"Zanghieri","year":"2019","journal-title":"IEEE Trans. Biomed. Circuits Syst"},{"key":"B58","first-page":"233","author":"Zhao","year":"2021","journal-title":"A System for Capturing of Electro-Muscular Signals to Control a Prosthesis"},{"key":"B59","first-page":"1","volume-title":"A Spatio-Temporal Graph Convolutional Network for Gesture Recognition from High-Density Electromyography","author":"Zhong","year":"2023"}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2025.1655257\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T05:34:42Z","timestamp":1756964082000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2025.1655257\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,4]]},"references-count":59,"alternative-id":["10.3389\/fnins.2025.1655257"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2025.1655257","relation":{"has-part":[{"id-type":"doi","id":"https:\/\/doi.org\/10.3389\/fnins.2025.1655257.s001","asserted-by":"subject"}]},"ISSN":["1662-453X"],"issn-type":[{"value":"1662-453X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,4]]},"article-number":"1655257"}}