{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T06:45:39Z","timestamp":1785739539460,"version":"3.56.0"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:p>Reliable bonding between polyimide layers is critical for the long-term performance of thin-film neural interfaces, yet the long-term durability of common adhesion methods under physiologically relevant conditions remains unclear. This study uses reactive-accelerated-aging (RAA) soak testing at 87\u00b0C to compare the ability of surface treatments based on oxygen plasma and KOH\/HCl soaks to enhance polyimide-to-polyimide adhesion. Peel testing was performed as a function of soak time and strip width to quantify degradation behavior. Oxygen plasma-treated samples exhibited high initial adhesion (~262 mN\/mm) but degraded rapidly in RAA, with bond strength decreasing linearly and failing within 3 to 6 days depending on width. The width dependence indicates edge-driven degradation, for which a predictive model of adhesion loss was developed. In contrast, KOH\/HCl-treated samples showed lower initial adhesion strength (~150 mN\/mm) but minimal degradation over the test duration and corresponded to an estimated minimum 40-fold improvement in bond lifetime. These overall results from this study demonstrate that plasma-based bonding of polyimide films is highly susceptible to oxidative degradation, while chemically reconstituted interfaces provide significantly improved stability that could be beneficial for chronic neural-implant applications.<\/jats:p>","DOI":"10.3389\/fnins.2026.1834110","type":"journal-article","created":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T06:02:57Z","timestamp":1785736977000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Reactive-accelerated-aging soak testing of thin-film polyimide layers treated with an oxygen plasma and chemical soaking"],"prefix":"10.3389","volume":"20","author":[{"suffix":"Jr.","given":"Kenneth A.","family":"Fluker","sequence":"first","affiliation":[{"name":"Nanoscience Institute for Medical and Engineering Technology, University of Florida","place":["Gainesville, FL, United States"]},{"name":"Electrical and Computer Engineering Department, University of Florida","place":["Gainesville, FL, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jack W.","family":"Judy","sequence":"additional","affiliation":[{"name":"Nanoscience Institute for Medical and Engineering Technology, University of Florida","place":["Gainesville, FL, United States"]},{"name":"Electrical and Computer Engineering Department, University of Florida","place":["Gainesville, FL, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"119731","DOI":"10.1016\/j.biomaterials.2019.119731","article-title":"Characterization of parylene-c degradation mechanisms: in vitro reactive accelerated aging model compared to multiyear in vivo implantation","volume":"232","author":"Caldwell","year":"2020","journal-title":"Biomaterials"},{"key":"B2","doi-asserted-by":"publisher","first-page":"3166","DOI":"10.3390\/ma12193166","article-title":"Biocompatibility of polyimides: a mini-review","volume":"12","author":"Constantin","year":"2019","journal-title":"Materials"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/Transducers61432.2025.11110719","article-title":"\u201cFabrication process for ultra-reliable polyimide-based neural-interface technology,\u201d","author":"Fluker","year":"2025","journal-title":"2025 23rd International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)"},{"key":"B4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1002\/polb.22169","article-title":"Polymers for neural implants","volume":"49","author":"Hassler","year":"2011","journal-title":"J. Polymer Sci. Part B"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1016\/j.medengphy.2008.06.001","article-title":"Accelerated aging for testing polymeric biomaterials and medical devices","volume":"30","author":"Hukins","year":"2008","journal-title":"Med. Eng. Phys"},{"key":"B6","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1109\/TDMR.2019.2907080","article-title":"On thermal acceleration of medical device polymer aging","volume":"19","author":"Janting","year":"2019","journal-title":"IEEE Trans. Device Mater. Reliab"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC40787.2023.10340337","article-title":"\u201cReactive-accelerated-aging testing of thinned tissue-engineered electronic nerve interfaces,\u201d","author":"Jiracek-Sapieha","year":"2023","journal-title":"45th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)"},{"key":"B8","doi-asserted-by":"publisher","first-page":"5061","DOI":"10.1109\/EMBC.2018.8513458","article-title":"\u201cin vitro reactive-accelerated-aging (RAA) assessment of tissue-engineered electronic nerve interfaces (teeni),\u201d","author":"Kuliasha","year":"2018","journal-title":"40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)"},{"key":"B9","doi-asserted-by":"publisher","first-page":"2100149","DOI":"10.1002\/admt.202100149","article-title":"The materials science foundation supportingthe microfabrication of reliable polyimide\u2013metalneuroelectronic interfaces","volume":"6","author":"Kuliasha","year":"2021","journal-title":"Adv. Mater. Technol"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2450","DOI":"10.1021\/la00059a009","article-title":"Surface modification of bpda-pda polyimide","volume":"7","author":"Lee","year":"1991","journal-title":"Langmuir"},{"key":"B11","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1007\/BF02477445","article-title":"A prototype flexible microelectrode array for implant-prosthesis applications","volume":"12","author":"Sonn","year":"1974","journal-title":"Med. Biol. Eng"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1021\/cm950317b","article-title":"Surface modification studies of polyimide films using rutherford backscattering and forward recoil spectrometry","volume":"8","author":"Stoffel","year":"1996","journal-title":"Chem. Mater"},{"key":"B13","doi-asserted-by":"publisher","first-page":"026003","DOI":"10.1088\/1741-2560\/12\/2\/026003","article-title":"Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species","volume":"12","author":"Takmakov","year":"2015","journal-title":"J. Neural Eng"},{"key":"B14","volume-title":"A Multielectrode Microprobe for Biopotential Recording","author":"Wise","year":"1969"}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1834110\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T06:02:58Z","timestamp":1785736978000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1834110\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":14,"alternative-id":["10.3389\/fnins.2026.1834110"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2026.1834110","relation":{},"ISSN":["1662-453X"],"issn-type":[{"value":"1662-453X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"article-number":"1834110"}}