{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T16:21:26Z","timestamp":1788452486641,"version":"build-2803163510"},"reference-count":44,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      Direct Saturation Dynamic Glucose Enhanced (DS-DGE) MRI is a novel technique that utilizes low B\n                      <jats:sub>1<\/jats:sub>\n                      strength and short saturation pulse duration to measure the effect of enhanced T\n                      <jats:sub>2<\/jats:sub>\n                      relaxation caused by the infusion of D-glucose, resulting in linewidth broadening of the direct water saturation (DS) signal in the water saturation spectrum (Z-spectrum). In this simulation-supported protocol optimization study, we investigated this approach for brain tumor applications, with particular emphasis on the design of the radiofrequency (RF) saturation pulses. Artifacts related to the bandwidth of the RF saturation pulses, affecting the linewidth derived from Lorentzian fitting of the DS resonance, were investigated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      <jats:italic>In vivo<\/jats:italic>\n                      DS-DGE MRI Z-spectra were analyzed using Lorentzian line-shape fitting. To support experimental findings, simulated Z-spectra were generated using Bloch-McConnell simulations implemented in Pulseq-CEST, covering a wide range of T\n                      <jats:sub>1<\/jats:sub>\n                      and T\n                      <jats:sub>2<\/jats:sub>\n                      relaxation times. Diverse RF saturation schemes were employed, varying in saturation duration, number of pulses, and pulse shape. The accuracy of Lorentzian fitting was assessed across these RF pulse configurations.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>RF pulses for a fixed total duration of 500 ms, with maximized individual pulse length, resulted in less sideband artifacts compared to using more pulses of shorter individual length. Choosing fewer than 5 pulses yielded Lorentzian linewidth estimates with a root-mean-square-error (RMSE) below 1 %.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      The use of longer RF pulses, within the 500 ms total saturation duration, improved estimation accuracy when employing a Lorentzian fit. This approach can be readily implemented without major modifications to the acquisition or post-processing protocol. These findings therefore provide a practical basis for future\n                      <jats:italic>in vivo<\/jats:italic>\n                      DS-DGE studies, as well as for other applications employing linewidth-sensitive Z-spectra approaches.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fnins.2026.1888576","type":"journal-article","created":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T15:47:53Z","timestamp":1788450473000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Radiofrequency bandwidth effects in direct saturation dynamic glucose enhanced MRI at 3T"],"prefix":"10.3389","volume":"20","author":[{"given":"Patrick Michael","family":"Lehmann","sequence":"first","affiliation":[{"name":"Department of Medical Radiation Physics, Lund University","place":["Lund, Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sajad","family":"Mohammed Ali","sequence":"additional","affiliation":[{"name":"Department of Medical Radiation Physics, Lund University","place":["Lund, Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nirbhay N.","family":"Yadav","sequence":"additional","affiliation":[{"name":"Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine","place":["Baltimore, MD, United States"]},{"name":"F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute","place":["Baltimore, MD, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anina","family":"Seidemo","sequence":"additional","affiliation":[{"name":"Institution of Clinical Sciences\/Radiology, Lund University","place":["Lund, Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronnie","family":"Wirestam","sequence":"additional","affiliation":[{"name":"Department of Medical Radiation Physics, Lund University","place":["Lund, Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pia Charlotte","family":"Sundgren","sequence":"additional","affiliation":[{"name":"Institution of Clinical Sciences\/Radiology, Lund University","place":["Lund, Sweden"]},{"name":"Lund University Bioimaging Centre, Lund University","place":["Lund, Sweden"]},{"name":"Department of Medical Imaging and Physiology, Sk\u00e5ne University Hospital","place":["Lund, Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emil","family":"Langensee Ljungberg","sequence":"additional","affiliation":[{"name":"Department of Medical Radiation Physics, Lund University","place":["Lund, Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linda","family":"Knutsson","sequence":"additional","affiliation":[{"name":"Department of Medical Radiation Physics, Lund University","place":["Lund, Sweden"]},{"name":"F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute","place":["Baltimore, MD, United States"]},{"name":"Department of Neurology, Johns Hopkins University School of Medicine","place":["Baltimore, MD, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1002\/mrm.28112","article-title":"Dynamic glucose-enhanced (DGE) MRI in the human brain at 7 T with reduced motion-induced artifacts based on quantitative R(1rho) mapping","volume":"84","author":"Boyd","year":"2020","journal-title":"Magn. Reson. Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"115966","DOI":"10.1016\/j.watres.2020.115966","article-title":"Anthropogenic gadolinium in freshwater and drinking water systems","volume":"182","author":"Br\u00fcnjes","year":"2020","journal-title":"Water Res"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1002\/mrm.24520","article-title":"Natural D -glucose as a biodegradable MRI contrast agent for detecting cancer","volume":"68","author":"Chan","year":"2012","journal-title":"Magn. Reson. Med"},{"key":"B4","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1002\/mrm.1910030312","article-title":"Influence of glycogen on water proton relaxation times","volume":"3","author":"Gore","year":"1986","journal-title":"Magn. Reson. Med"},{"key":"B5","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1002\/nbm.683","article-title":"Magnetization transfer in MRI: a review","volume":"14","author":"Henkelman","year":"2001","journal-title":"NMR Biomed"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1832","DOI":"10.1002\/mrm.27857","article-title":"T1\u03c1-based dynamic glucose-enhanced (DGE\u03c1) MRI at 3 T: method development and early clinical experience in the human brain","volume":"82","author":"Herz","year":"2019","journal-title":"Magn. Reson. Med"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1845","DOI":"10.1002\/mrm.28825","article-title":"Pulseq-CEST: towards multi-site multi-vendor compatibility and reproducibility of CEST experiments using an open-source sequence standard","volume":"86","author":"Herz","year":"2021","journal-title":"Magn. Reson. Med"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1448","DOI":"10.1002\/mrm.22721","article-title":"Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons","volume":"65","author":"Jin","year":"2011","journal-title":"Magn. Reson. Med"},{"key":"B9","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1002\/mrm.27183","article-title":"Chemical exchange\u2013sensitive spin-lock (CESL) MRI of glucose and analogs in brain tumors","volume":"80","author":"Jin","year":"2018","journal-title":"Magn. Reson. Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.1002\/mrm.23141","article-title":"In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T","volume":"67","author":"Jones","year":"2012","journal-title":"Magn. Reson. Med"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1002\/mrm.21873","article-title":"Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments","volume":"61","author":"Kim","year":"2009","journal-title":"Magn. Reson. Med"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10334-009-0190-2","article-title":"Absolute quantification of perfusion using dynamic susceptibility contrast MRI: Pitfalls and possibilities","volume":"23","author":"Knutsson","year":"2010","journal-title":"Magn. Reson. Mater. Phy. Biol. Med"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1002\/mrm.27341","article-title":"CEST, ASL, and magnetization transfer contrast: how similar pulse sequences detect di?erent phenomena","volume":"80","author":"Knutsson","year":"2018","journal-title":"Magn. Reson. Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"e4784","DOI":"10.1002\/nbm.4784","article-title":"Imaging of sugar-based contrast agents using their hydroxyl proton exchange properties","volume":"36","author":"Knutsson","year":"2023","journal-title":"NMR Biomed"},{"key":"B15","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1002\/mrm.30447","article-title":"Dynamic glucose enhanced imaging using direct water saturation","volume":"94","author":"Knutsson","year":"2025","journal-title":"Magn. Reson. Med"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1871","DOI":"10.1002\/mrm.29563","article-title":"A numerical human brain phantom for dynamic glucose-enhanced (DGE) MRI: on the influence of head motion at 3T","volume":"89","author":"Lehmann","year":"2023","journal-title":"Magn. Reson. Med."},{"key":"B17","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.neuroimage.2013.09.072","article-title":"Quantitative magnetic susceptibility mapping without phase unwrapping using WASSR","volume":"86","author":"Lim","year":"2014","journal-title":"Neuroimage"},{"key":"B18","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1002\/nbm.2899","article-title":"Nuts and bolts of chemical exchange saturation transfer MRI","volume":"26","author":"Liu","year":"2013","journal-title":"NMR Biomed."},{"key":"B19","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1080\/02841850500539033","article-title":"Glioma assessment using quantitative blood volume maps generated by T1-weighted dynamic contrast-enhanced magnetic resonance imaging: a receiver operating characteristic study","volume":"47","author":"L\u00fcdemann","year":"2006","journal-title":"Acta Radiol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"549","DOI":"10.3174\/ajnr.A1844","article-title":"Candidate biomarkers of extravascular extracellular space: a direct comparison of apparent diffusion coefficient and dynamic contrast-enhanced MR imaging\u2014derived measurement of the volume of the extravascular extracellular space in glioblastoma multiforme","volume":"31","author":"Mills","year":"2010","journal-title":"Am. J. Neuroradiol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"e5265","DOI":"10.1002\/nbm.5265","article-title":"Dynamic glucose-enhanced MRI of gliomas: a preliminary clinical application","volume":"38","author":"Mo","year":"2025","journal-title":"NMR Biomed"},{"key":"B22","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1002\/mrm.30460","article-title":"Machine learning-based multi-pool Voigt fitting of CEST, rNOE, and MTC in Z-spectra","volume":"94","author":"Mohammed Ali","year":"2025","journal-title":"Magn. Reson. Med"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1610","DOI":"10.1002\/mrm.29718","article-title":"Deep learning-based Lorentzian fitting of water saturation shift referencing spectra in MRI","volume":"90","author":"Mohammed Ali","year":"2023","journal-title":"Magn. Reson. Med."},{"key":"B24","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1118\/1.597063","article-title":"The general solution to the Bloch equation with constant rf and relaxation terms: application to saturation and slice selection","volume":"20","author":"Mulkern","year":"1993","journal-title":"Med. Phys"},{"key":"B25","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1148\/radiol.2017162351","article-title":"T1rho-weighted dynamic glucose-enhanced MR imaging in the human Brain","volume":"285","author":"Paech","year":"2017","journal-title":"Radiology"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1620","DOI":"10.1002\/mrm.22750","article-title":"Optimization of pulse train presaturation for CEST imaging in clinical scanners","volume":"65","author":"Schmitt","year":"2011","journal-title":"Magn. Reson. Med"},{"key":"B27","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.1002\/mrm.30011","article-title":"Sidebands in CEST MR-how to recognize and avoid them","volume":"91","author":"Schure","year":"2024","journal-title":"Magn. Reson. Med."},{"key":"B28","doi-asserted-by":"publisher","first-page":"e4863","DOI":"10.1002\/nbm.4863","article-title":"Tissue response curve-shape analysis of dynamic glucose-enhanced and dynamic contrast-enhanced magnetic resonance imaging in patients with brain tumor","volume":"36","author":"Seidemo","year":"2023","journal-title":"NMR Biomed"},{"key":"B29","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1002\/mrm.1278","article-title":"Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI","volume":"46","author":"Sled","year":"2001","journal-title":"Magn. Reson. Med"},{"key":"B30","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1002\/mrm.21980","article-title":"Direct saturation MRI: theory and application to imaging brain iron","volume":"62","author":"Smith","year":"2009","journal-title":"Magn. Reson. Med"},{"key":"B31","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1002\/(SICI)1522-2594(199912)42:6<1128::AID-MRM18>3.0.CO;2-9","article-title":"Characterizing white matter with magnetization transfer andT2","volume":"42","author":"Stanisz","year":"1999","journal-title":"Magn. Reson. Med"},{"key":"B32","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1002\/(SICI)1522-2586(199909)10:3<223::AID-JMRI2>3.0.CO;2-S","article-title":"Estimating kinetic parameters from dynamic contrast-enhanced t1-weighted MRI of a diffusable tracer: standardized quantities and symbols","volume":"10","author":"Tofts","year":"1999","journal-title":"J. Magn. Reson. Imag"},{"key":"B33","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.neuroimage.2015.12.032","article-title":"Effects of magnetization transfer on T1 contrast in human brain white matter","volume":"128","author":"van Gelderen","year":"2016","journal-title":"Neuroimage"},{"key":"B34","doi-asserted-by":"publisher","first-page":"4788","DOI":"10.1007\/s00330-025-12306-5","article-title":"ESR essentials: perfusion MRI\u2014practice recommendations by the European society for magnetic resonance in medicine and biology","volume":"36","author":"van Houdt","year":"2026","journal-title":"Eur. Radiol"},{"key":"B35","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1002\/mrm.22761","article-title":"Chemical exchange saturation transfer (CEST): What is in a name and what isn't?","volume":"65","author":"Van Zijl","year":"2011","journal-title":"Magn. Reson. Med"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1038\/nm.3252","article-title":"In vivo imaging of glucose uptake and metabolism in tumors","volume":"19","author":"Walker-Samuel","year":"2013","journal-title":"Nat. Med"},{"key":"B37","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1006\/jmre.1999.1956","article-title":"New class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)","volume":"143","author":"Ward","year":"2000","journal-title":"J. Magn. Reson"},{"key":"B38","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1186\/s41747-023-00390-5","article-title":"Improved postprocessing of dynamic glucose-enhanced CEST MRI for imaging brain metastases at 3 T","volume":"7","author":"Wu","year":"2023","journal-title":"Eur. Radiol. Exp"},{"key":"B39","doi-asserted-by":"publisher","first-page":"1556","DOI":"10.1002\/mrm.25995","article-title":"Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer","volume":"74","author":"Xu","year":"2015","journal-title":"Magn. Reson. Med"},{"key":"B40","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1002\/mrm.28124","article-title":"d-glucose weighted chemical exchange saturation transfer (glucoCEST)-based dynamic glucose enhanced (DGE) MRI at 3T: early experience in healthy volunteers and brain tumor patients","volume":"84","author":"Xu","year":"2020","journal-title":"Magn. Reson. Med"},{"key":"B41","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1002\/mrm.25329","article-title":"Natural D-glucose as a biodegradable MRI relaxation agent","volume":"72","author":"Yadav","year":"2014","journal-title":"Magn. Reson. Med"},{"key":"B42","doi-asserted-by":"publisher","first-page":"e4113","DOI":"10.1002\/nbm.4113","article-title":"Quantification of hydroxyl exchange of D-Glucose at physiological conditions for optimization of glucoCEST MRI at 3, 7 and 9.4 Tesla","volume":"32","author":"Zaiss","year":"","journal-title":"NMR Biomed."},{"key":"B43","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.jmr.2018.11.002","article-title":"Possible artifacts in dynamic CEST MRI due to motion and field alterations","volume":"298","author":"Zaiss","year":"","journal-title":"J. Magn. Reson"},{"key":"B44","doi-asserted-by":"publisher","first-page":"e4789","DOI":"10.1002\/nbm.4789","article-title":"Theory of chemical exchange saturation transfer MRI in the context of different magnetic fields","volume":"35","author":"Zaiss","year":"2022","journal-title":"NMR Biomed"}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1888576\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T15:47:54Z","timestamp":1788450474000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1888576\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":44,"alternative-id":["10.3389\/fnins.2026.1888576"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2026.1888576","relation":{},"ISSN":["1662-453X"],"issn-type":[{"value":"1662-453X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]},"article-number":"1888576"}}