{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T13:00:58Z","timestamp":1790168458125,"version":"4.1.0"},"reference-count":125,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:p>Endovascular neural interfaces (ENIs) have emerged as a minimally invasive alternative to traditional neural interfaces. These devices are implanted within blood vessels adjacent to neural tissue to record or stimulate neural activity across the vessel wall. This enables minimally invasive implantation through angiographic procedures and reduces the risk of neural tissue damage. As they are deployed in the intravascular space, ENIs have a similar technological evolution to cardiovascular devices and share many features and constraints. First-generation ENIs borrowed guide wires and catheters employed in cardiovascular procedures for endovascular neural recording but were limited to acute settings. Concurrently, the cardiovascular field explored the possibility of integrating electronics onto endovascular devices. Catheters have been used for endovascular stimulation as a treatment for cardiovascular conditions. Cardiovascular stents have been integrated with wireless sensors, enabling self-reporting stents to monitor implant health. In 2016, a breakthrough in the field of ENIs was achieved by leveraging the chronic stability of stents to support an electrode array. Exemplified by Synchron\u2019s Stentrode\u2122, stent electrode arrays have been successfully employed as a brain-computer interface for chronic motor cortex recording. Subsequent research in the field has focused on expanding applications and improving spatial resolution. Incorporating valuable lessons from the field of interventional cardiology will be key to accelerate ENI development, especially in the areas of device miniaturisation, enhancement of stimulation capabilities, and wireless communication. Addressing these limitations could revolutionise the treatment of neurological disorders, enabling high spatial resolution recording and stimulation possible through minimally invasive, accessible procedures.<\/jats:p>","DOI":"10.3389\/fnins.2026.1933040","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T12:04:31Z","timestamp":1790165071000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Endovascular approaches to neural interfacing: lessons from cardiovascular technologies"],"prefix":"10.3389","volume":"20","author":[{"given":"Leire","family":"Landeira-Suquia","sequence":"first","affiliation":[{"name":"Department of Bioengineering, Imperial College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Estelle A.","family":"Cuttaz","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Goding","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sam E.","family":"John","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Melbourne","place":["Parkville, VIC, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rylie A.","family":"Green","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"122","DOI":"10.31083\/J.RCM2504122","article-title":"Emerging role of renal sympathetic denervation as an adjunct therapy to atrial fibrillation ablation","volume":"25","author":"Akrawinthawong","year":"2024","journal-title":"Rev. Cardiovasc. Med."},{"key":"ref2","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1109\/JERM.2018.2833386","article-title":"Near-field wireless power transfer to stent-based biomedical implants","volume":"2","author":"Aldaoud","year":"2018","journal-title":"IEEE J. Electromagn. RF Microw. Med. Biol."},{"key":"ref3","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1159\/000500051","article-title":"Neuroendovascular cerebral sinus stenting in idiopathic intracranial hypertension","volume":"8","author":"Al-Mufti","year":"2019","journal-title":"Interv. Neurol."},{"key":"ref4","doi-asserted-by":"publisher","first-page":"446","DOI":"10.25259\/SNI_406_2025","article-title":"Safety and efficacy of phrenic nerve stimulation: a case series at the University of Oklahoma and review of the international literature","volume":"16","author":"Balasubramanian","year":"2025","journal-title":"Surg. Neurol. Int."},{"key":"ref5","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/S12987-025-00640-1","article-title":"Is the ischemia found in normal pressure hydrocephalus secondary to venous compression or arterial constriction? A comment on Ohmura et al","volume":"22","author":"Bateman","year":"2025","journal-title":"Fluids Barriers CNS"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"42781","DOI":"10.1021\/acsami.5c08212","article-title":"Implantable membrane sensors and long-range wireless electronics for continuous monitoring of stent edge restenosis","volume":"17","author":"Bateman","year":"2025","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1126\/science.aaw9295","article-title":"How conducting polymer electrodes operate","volume":"364","author":"Berggren","year":"2019","journal-title":"Science (1979)"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1136\/JNNP.62.2.193","article-title":"Endovascular electroencephalography: the technique and its application during carotid amytal assessment","volume":"62","author":"Boniface","year":"1997","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/J.JNEUMETH.2012.12.027","article-title":"Intravenous recording of intracranial, broadband EEG","volume":"214","author":"Bower","year":"2013","journal-title":"J. Neurosci. Methods"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1353","DOI":"10.1136\/JNIS-2023-021434","article-title":"Superior cortical venous anatomy for endovascular device implantation: a systematic review","volume":"16","author":"Brannigan","year":"2024","journal-title":"J. Neurointerv. Surg."},{"key":"ref11","doi-asserted-by":"publisher","first-page":"E1150","DOI":"10.21037\/JTD.2016.10.93","article-title":"Understanding and managing in-stent restenosis: a review of clinical data, from pathogenesis to treatment","volume":"8","author":"Buccheri","year":"2016","journal-title":"J. Thorac. Dis."},{"key":"ref12","doi-asserted-by":"publisher","first-page":"100353","DOI":"10.1016\/J.MEDNTD.2025.100353","article-title":"The history, current state and future possibilities of the non-invasive brain computer interfaces","volume":"25","author":"Caiado","year":"2025","journal-title":"Med. Nov. Technol. Devices"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"430","DOI":"10.3390\/MI9090430","article-title":"Chronically implanted intracranial electrodes: tissue reaction and electrical changes","volume":"9","author":"Campbell","year":"2018","journal-title":"Micromachines (Basel)."},{"key":"ref14","doi-asserted-by":"publisher","first-page":"1700560","DOI":"10.1002\/ADVS.201700560","article-title":"Enabling angioplasty-ready \u201csmart\u201d stents to detect in-stent restenosis and occlusion","volume":"5","author":"Chen","year":"2018","journal-title":"Adv. Sci."},{"key":"ref15","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1038\/s41551-024-01281-9","article-title":"Endocisternal interfaces for minimally invasive neural stimulation and recording of the brain and spinal cord","volume":"9","author":"Chen","year":"2024","journal-title":"Nat Biomed Eng"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1038\/S41551-022-00873-7","article-title":"A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves","volume":"6","author":"Chen","year":"2022","journal-title":"Nat. Biomed. Eng."},{"key":"ref17","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1152\/JAPPLPHYSIOL.00264.2013","article-title":"Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress","volume":"115","author":"Chen","year":"2013","journal-title":"J. Appl. Physiol."},{"key":"ref18","doi-asserted-by":"publisher","first-page":"794","DOI":"10.3390\/MI12070794","article-title":"Biocompatibility of SU-8 and its biomedical device applications","volume":"12","author":"Chen","year":"2021","journal-title":"Micromachines (Basel)."},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1101\/2025.09.19.25335897","article-title":"Signal properties and stability of a chronically implanted endovascular brain computer interface","author":"Chetty","year":"2025","journal-title":"medRxiv"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1109\/TBME.2010.2041058","article-title":"Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent","volume":"57","author":"Chow","year":"2010","journal-title":"I.E.E.E. Trans. Biomed. Eng."},{"key":"ref21","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1146\/ANNUREV.BIOENG.10.061807.160518\/CITE\/REFWORKS","article-title":"Neural stimulation and recording electrodes","volume":"10","author":"Cogan","year":"2008","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref22","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1111\/JCMM.13936","article-title":"The effects of stenting on coronary endothelium from a molecular biological view: time for improvement?","volume":"23","author":"Cornelissen","year":"2018","journal-title":"J. Cell. Mol. Med."},{"key":"ref23","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1161\/01.CIR.0000140721.27004.4B","article-title":"Beyond restenosis: five-year clinical outcomes from second-generation coronary stent trials","volume":"110","author":"Cutlip","year":"2004","journal-title":"Circulation"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.1039\/C8BM01235K","article-title":"Conductive elastomer composites for fully polymeric, flexible bioelectronics","volume":"7","author":"Cuttaz","year":"2019","journal-title":"Biomater. Sci."},{"key":"ref25","first-page":"453","author":"Diao","year":"2025"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1055\/S-0038-1651501","article-title":"Skull Base Dural thickness and relationship to demographic features: a postmortem study and literature review","volume":"79","author":"Fam","year":"2018","journal-title":"J. Neurol. Surg. B Skull Base"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"522685","DOI":"10.3389\/FNINS.2020.00432\/TEXT","article-title":"Over the horizon: the present and future of endovascular neural recording and stimulation","volume":"14","author":"Fan","year":"2020","journal-title":"Front. Neurosci."},{"key":"ref28","doi-asserted-by":"publisher","first-page":"2100176","DOI":"10.1002\/ADMT.202100176","article-title":"Transient neurovascular Interface for minimally invasive neural recording and stimulation","volume":"7","author":"Fanelli","year":"2022","journal-title":"Adv. Mater. Technol."},{"key":"ref29","doi-asserted-by":"crossref","DOI":"10.4199\/C00031ED1V01Y201105ISP019","volume-title":"The Endothelium: part 1: Multiple Functions of the Endothelial Cells\u2014Focus on Endothelium-Derived Vasoactive Mediators","author":"F\u00e9l\u00e9tou","year":"2011"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/S1051-0443(94)71593-1","article-title":"Stent-induced intimal hyperplasia: are there fundamental differences between flexible and rigid stent designs?","volume":"5","author":"Fontaine","year":"1994","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref31","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1056\/NEJM195911052611904","article-title":"An intracardiac pacemaker for stokes-Adams seizures","volume":"261","author":"Furman","year":"1959","journal-title":"N. Engl. J. Med."},{"key":"ref32","first-page":"373","article-title":"Novel techniques in epilepsy management: venous pacing and capture of electrical activity in the primate cortex","volume-title":"J. Neurol. Neurophysiol.","author":"Gaba","year":"2016"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1080\/17581869.2025.2488244","article-title":"Peripheral nerve stimulation: recent advances and future directions","volume":"15","author":"Ganji-Angirekula","year":"2025","journal-title":"Pain Manag."},{"key":"ref34","first-page":"3088","author":"Gerboni","year":"2018"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"1601177","DOI":"10.1002\/ADHM.201601177","article-title":"Interpenetrating conducting hydrogel materials for neural interfacing electrodes","volume":"6","author":"Goding","year":"2017","journal-title":"Adv. Healthc. Mater."},{"key":"ref36","doi-asserted-by":"publisher","first-page":"204","DOI":"10.4330\/WJC.V7.I4.204","article-title":"Autonomic and endocrine control of cardiovascular function","volume":"7","author":"Gordan","year":"2015","journal-title":"World J. Cardiol."},{"key":"ref37","doi-asserted-by":"publisher","first-page":"7620","DOI":"10.1002\/ADMA.201501810","article-title":"Conducting polymers for neural prosthetic and neural Interface applications","volume":"27","author":"Green","year":"2015","journal-title":"Adv. Mater."},{"key":"ref38","doi-asserted-by":"publisher","first-page":"5875","DOI":"10.1016\/J.BIOMATERIALS.2012.05.017","article-title":"Substrate dependent stability of conducting polymer coatings on medical electrodes","volume":"33","author":"Green","year":"2012","journal-title":"Biomaterials"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"3393","DOI":"10.1016\/J.BIOMATERIALS.2008.04.047","article-title":"Conducting polymers for neural interfaces: challenges in developing an effective long-term implant","volume":"29","author":"Green","year":"2008","journal-title":"Biomaterials"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"056017","DOI":"10.1088\/1741-2560\/11\/5\/056017","article-title":"Laser patterning of platinum electrodes for safe neurostimulation","volume":"11","author":"Green","year":"2014","journal-title":"J. Neural Eng."},{"key":"ref41","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1002\/J.2040-4603.2016.TB00700.X","article-title":"Hemodynamics","volume":"6","author":"Guyton","year":"2016","journal-title":"Compr. Physiol."},{"key":"ref42","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1111\/AOR.14049","article-title":"Synchron receives FDA approval to begin early feasibility study of their endovascular, brain-computer interface device","volume":"45","author":"Han","year":"2021","journal-title":"Artif. Organs"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"9676","DOI":"10.1038\/s41598-025-93941-2","article-title":"Endovascular neural stimulation with platinum and platinum black modified electrodes","volume":"15","author":"Harris","year":"2025","journal-title":"Sci. Rep."},{"key":"ref44","volume-title":"StatPearls.","author":"Hasan","year":"2023"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1536\/jhj.44.417","article-title":"Endovascular stimulation of autonomic neural elements in the superior vena cava using a flexible loop catheter experimental studies","volume":"44","author":"Hasdemir","year":"2003","journal-title":"Jpn Heart J"},{"key":"ref46","doi-asserted-by":"publisher","first-page":"eabm1175","DOI":"10.1126\/SCIADV.ABM1175","article-title":"Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics","volume":"8","author":"Herbert","year":"2022","journal-title":"Sci. Adv."},{"key":"ref47","doi-asserted-by":"publisher","first-page":"2007","DOI":"10.1053\/euhj.2001.2606","article-title":"Stent design related neointimal tissue proliferation in human coronary arteries an intravascular ultrasound study","volume":"22","author":"Hoffmann","year":"2001","journal-title":"Eur. Heart J."},{"key":"ref48","doi-asserted-by":"publisher","first-page":"8706","DOI":"10.1021\/ACSNANO.8B04689\/SUPPL_FILE\/NN8B04689_SI_001.PDF","article-title":"Stretchable, implantable, nanostructured flow-diverter system for quantification of intra-aneurysmal hemodynamics","volume":"12","author":"Howe","year":"2018","journal-title":"ACS Nano"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1101\/2024.08.29.610418","article-title":"A microendovascular system can record precise neural signals from cortical and deep vessels with minimal invasiveness","author":"Iwata","year":"2024","journal-title":"bioRxiv"},{"key":"ref50","doi-asserted-by":"publisher","first-page":"056043","DOI":"10.1088\/1741-2552\/AC9A77","article-title":"Vascular remodeling in sheep implanted with endovascular neural interface","volume":"19","author":"John","year":"2022","journal-title":"J. Neural Eng."},{"key":"ref51","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/J.NEUBIOREV.2017.06.002","article-title":"The ovine motor cortex: a review of functional mapping and cytoarchitecture","volume":"80","author":"John","year":"2017","journal-title":"Neurosci. Biobehav. Rev."},{"key":"ref52","doi-asserted-by":"publisher","first-page":"8427","DOI":"10.1038\/s41598-018-26457-7","article-title":"Signal quality of simultaneously recorded endovascular, subdural and epidural signals are comparable","volume":"8","author":"John","year":"2018","journal-title":"Sci. Rep."},{"key":"ref53","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1227\/ONS.0000000000001226","article-title":"Feasibility of endovascular deep brain stimulation of anterior nucleus of the thalamus for refractory epilepsy","volume":"28","author":"Kashyap","year":"2025","journal-title":"Oper. Neurosurg. (Hagerstown)"},{"key":"ref54","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1016\/J.ANCLIN.2022.08.008","article-title":"Surgical decision-making and outcomes in open versus endovascular repair for various vascular diseases","volume":"40","author":"Keegan","year":"2022","journal-title":"Anesthesiol. Clin."},{"key":"ref55","doi-asserted-by":"publisher","first-page":"20210020","DOI":"10.1098\/RSTA.2021.0020\/112153","article-title":"Wireless interfaces for brain neurotechnologies","volume":"380","author":"Kim","year":"2022","journal-title":"Philos. Trans. R. Soc. A Math. Phys. Eng. Sci."},{"key":"ref56","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1007\/S00392-002-1317-X\/METRICS","article-title":"Influence of stent design and deployment technique on neointima formation and vascular remodeling","volume":"91","author":"K\u00f6nig","year":"2002","journal-title":"Z. Kardiol."},{"key":"ref57","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1016\/S0140-6736(09)60566-3","article-title":"Catheter-based renal sympathetic denervation for resistant hypertension: a multicentre safety and proof-of-principle cohort study","volume":"373","author":"Krum","year":"2009","journal-title":"Lancet"},{"key":"ref58","doi-asserted-by":"publisher","first-page":"215","DOI":"10.3390\/BIOENGINEERING8120215","article-title":"Control of blood coagulation by Hemocompatible material surfaces\u2014a review","volume":"8","author":"Kuchinka","year":"2021","journal-title":"Bioengineering"},{"key":"ref59","doi-asserted-by":"publisher","first-page":"108523","DOI":"10.1016\/J.JNEUMETH.2019.108523","article-title":"A review for the peripheral nerve interface designer","volume":"332","author":"Larson","year":"2020","journal-title":"J. Neurosci. Methods"},{"key":"ref60","doi-asserted-by":"publisher","first-page":"e2404680","DOI":"10.1002\/ADHM.202404680","article-title":"Non-surgical, in-stent membrane bioelectronics for long-term intracranial pressure monitoring","volume":"14","author":"Lee","year":"2025","journal-title":"Adv. Healthc. Mater."},{"key":"ref61","doi-asserted-by":"publisher","first-page":"036034","DOI":"10.1088\/1741-2552\/AD4F16","article-title":"Feasibility of endovascular stimulation of the femoral nerve using a stent-mounted electrode array","volume":"21","author":"Liu","year":"2024","journal-title":"J. Neural Eng."},{"key":"ref62","doi-asserted-by":"publisher","first-page":"111180","DOI":"10.1016\/J.JOCN.2025.111180","article-title":"Trans-arterial approach for neural recording and stimulation: present and future","volume":"135","author":"Liu","year":"2025","journal-title":"J. Clin. Neurosci."},{"key":"ref63","doi-asserted-by":"publisher","first-page":"4958","DOI":"10.1039\/D3MA01105D","article-title":"The past, present, and future of in vivo -implantable recording microelectrodes: the neural interfaces","volume":"5","author":"Liu","year":"2024","journal-title":"Mater. Adv."},{"key":"ref64","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/S11051-005-3134-4\/METRICS","article-title":"Neuro-vascular central nervous recording\/stimulating system: using nanotechnology probes","volume":"7","author":"Llin\u00e1s","year":"2005","journal-title":"J. Nanopart. Res."},{"key":"ref65","first-page":"185","volume-title":"Annu. Rev. Biomed. Eng.","author":"Luan","year":"2023"},{"key":"ref66","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1111\/JCE.12466","article-title":"Transvenous stimulation of the renal sympathetic nerves increases systemic blood pressure: a potential new treatment option for Neurocardiogenic Syncope","volume":"25","author":"Madhavan","year":"2014","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref67","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1016\/J.JACC.2019.11.058","article-title":"Stent-related adverse events >1 year after percutaneous coronary intervention","volume":"75","author":"Madhavan","year":"2020","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref68","doi-asserted-by":"publisher","first-page":"51","DOI":"10.15420\/ICR.2015:17:2","article-title":"Dual antiplatelet therapy after drug-eluting stent implantation","volume":"11","author":"Magnani","year":"2016","journal-title":"Interventional Cardiology Review"},{"key":"ref69","doi-asserted-by":"publisher","first-page":"982185","DOI":"10.3389\/FPHAR.2022.982185\/XML","article-title":"Biofunctionalization of cardiovascular stents to induce endothelialization: implications for in- stent thrombosis in diabetes","volume":"13","author":"Marei","year":"2022","journal-title":"Front. Pharmacol."},{"key":"ref70","doi-asserted-by":"publisher","first-page":"100748","DOI":"10.1016\/J.EBR.2025.100748","article-title":"First experiences with multiple bilateral insertions of a newly developed microcatheter-compatible endovascular electroencephalogram electrode for humans with epilepsy","volume":"29","author":"Masuda","year":"2025","journal-title":"Epilepsy Behav. Rep."},{"key":"ref71","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/J.PROGPOLYMSCI.2018.05.002","article-title":"Bio-resorbable polymer stents: a review of material progress and prospects","volume":"83","author":"McMahon","year":"2018","journal-title":"Prog. Polym. Sci."},{"key":"ref72","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/J.1528-1157.1997.TB01738.X","article-title":"\u201cCavernous sinus EEG\u201d: a new method for the preoperative evaluation of temporal lobe epilepsy","volume":"38","author":"Mikuni","year":"1997","journal-title":"Epilepsia"},{"key":"ref73","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1001\/JAMANEUROL.2022.4847","article-title":"Assessment of safety of a fully implanted endovascular brain-computer Interface for severe paralysis in 4 patients: the Stentrode with thought-controlled digital SWITCH (SWITCH) study","volume":"80","author":"Mitchell","year":"2023","journal-title":"JAMA Neurol."},{"key":"ref74","doi-asserted-by":"publisher","first-page":"2301692","DOI":"10.1002\/ADMT.202301692","article-title":"Electrocorticogram (ECoG): engineering approaches and clinical challenges for translational medicine","volume":"9","author":"Moon","year":"2024","journal-title":"Adv. Mater. Technol."},{"key":"ref75","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/0002-8703(95)90055-1","article-title":"The history of interventional cardiology: cardiac catheterization, angioplasty, and related interventions","volume":"129","author":"Mueller","year":"1995","journal-title":"Am. Heart J."},{"key":"ref76","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3390\/JCRM2020007","article-title":"Renal denervation: from historical roots to the modern therapeutic paradigm","volume":"2","author":"Mul\u00e8","year":"2026","journal-title":"J. CardioRenal Med."},{"key":"ref77","doi-asserted-by":"publisher","first-page":"S215","DOI":"10.1111\/J.1540-8159.2007.00641.X","article-title":"Lead design and initial applications of a new Lead for long-term endovascular vagal stimulation","volume":"30","author":"Nabutovsky","year":"2007","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref78","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/BF01411445\/METRICS","article-title":"An intra-arterial electrode for intracranial electro-encephalogram recordings","volume":"136","author":"Nakase","year":"1995","journal-title":"Acta Neurochir."},{"key":"ref79","doi-asserted-by":"publisher","first-page":"1078","DOI":"10.1111\/JCE.13018","article-title":"Blood pressure responses to endovascular stimulation: a potential therapy for autonomic disorders with vasodilatation","volume":"27","author":"Naksuk","year":"2016","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref80","doi-asserted-by":"publisher","first-page":"1668","DOI":"10.1016\/J.BRS.2020.09.016","article-title":"Endovascular deep brain stimulation: investigating the relationship between vascular structures and deep brain stimulation targets","volume":"13","author":"Neudorfer","year":"2020","journal-title":"Brain Stimul."},{"key":"ref81","doi-asserted-by":"publisher","first-page":"046008","DOI":"10.1088\/1741-2552\/acdb9b","article-title":"Vagus nerve stimulation using an endovascular electrode array","volume":"20","author":"Nicolai","year":"2023","journal-title":"J. Neural Eng."},{"key":"ref82","doi-asserted-by":"publisher","first-page":"110471","DOI":"10.1016\/J.JNEUMETH.2025.110471","article-title":"Advances in endovascular brain computer interface: systematic review and future implications","volume":"420","author":"Ognard","year":"2025","journal-title":"J. Neurosci. Methods"},{"key":"ref83","volume-title":"Raynaud\u2019s Phenomenon: From Pathogenesis to Management, Second Edition","author":"Omeh","year":"2023"},{"key":"ref84","doi-asserted-by":"publisher","first-page":"046020","DOI":"10.1088\/1741-2560\/13\/4\/046020","article-title":"Chronic impedance spectroscopy of an endovascular stent-electrode array","volume":"13","author":"Opie","year":"2016","journal-title":"J. Neural Eng."},{"key":"ref85","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1038\/s41551-018-0321-z","article-title":"Focal stimulation of the sheep motor cortex with a chronically implanted minimally invasive electrode array mounted on an endovascular stent","volume":"2","author":"Opie","year":"2018","journal-title":"Nat Biomed Eng"},{"key":"ref86","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1111\/AOR.14007","article-title":"The potential of closed-loop endovascular neurostimulation as a viable therapeutic approach for drug-resistant epilepsy: a critical review","volume":"46","author":"Opie","year":"2022","journal-title":"Artif. Organs"},{"key":"ref87","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1109\/TBME.2016.2552226","article-title":"Micro-CT and histological evaluation of an neural Interface implanted within a blood vessel","volume":"64","author":"Opie","year":"2017","journal-title":"I.E.E.E. Trans. Biomed. Eng."},{"key":"ref88","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1038\/NBT.3428","article-title":"Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity","volume":"34","author":"Oxley","year":"2016","journal-title":"Nat. Biotechnol."},{"key":"ref89","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.3171\/2016.11.JNS161754","article-title":"An ovine model of cerebral catheter venography for implantation of an endovascular neural interface","volume":"128","author":"Oxley","year":"2017","journal-title":"J. Neurosurg."},{"key":"ref90","doi-asserted-by":"publisher","first-page":"4542","DOI":"10.1021\/acssensors.3c01313","article-title":"Implantable self-reporting stents for detecting in-stent restenosis and cardiac functional dynamics","volume":"8","author":"Oyunbaatar","year":"2023","journal-title":"ACS Sens."},{"key":"ref91","doi-asserted-by":"publisher","first-page":"014001","DOI":"10.1088\/1741-2552\/ACAB86","article-title":"Utah Array characterization and histological analysis of a multi-year implant in non-human primate motor and sensory cortices","volume":"20","author":"Patel","year":"2023","journal-title":"J. Neural Eng."},{"key":"ref92","doi-asserted-by":"publisher","first-page":"239","DOI":"10.3171\/JNS.1973.38.2.0239","article-title":"Intravascular intracranial EEG recording: Technical note","volume":"38","author":"Penn","year":"1973","journal-title":"J. Neurosurg."},{"key":"ref93","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1093\/EURHEARTJ\/EHR298","article-title":"Transvenous phrenic nerve stimulation for the treatment of central sleep apnoea in heart failure","volume":"33","author":"Ponikowski","year":"2011","journal-title":"Eur. Heart J."},{"key":"ref94","doi-asserted-by":"publisher","first-page":"3071","DOI":"10.1109\/TBME.2025.3645257","article-title":"Wall shear stress predicts venous tissue growth in endovascular neural interfaces","volume":"73","author":"Qi","year":"2025","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref95","doi-asserted-by":"publisher","first-page":"7212","DOI":"10.1038\/s41598-024-57460-w","article-title":"Haemodynamics of stent-mounted neural interfaces in tapered and deformed blood vessels","volume":"14","author":"Qi","year":"2024","journal-title":"Sci. Rep."},{"key":"ref96","doi-asserted-by":"publisher","first-page":"E19","DOI":"10.3171\/2018.4.FOCUS18130","article-title":"Endovascular delivery of leads and stentrodes and their applications to deep brain stimulation and neuromodulation: a review","volume":"45","author":"Rajah","year":"2018","journal-title":"Neurosurg. Focus"},{"key":"ref97","doi-asserted-by":"publisher","first-page":"522852","DOI":"10.3389\/FNEUR.2020.00351\/TEXT","article-title":"Endovascular neuromodulation: safety profile and future directions","volume":"11","author":"Raza","year":"2020","journal-title":"Front. Neurol."},{"key":"ref98","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1161\/CIRCINTERVENTIONS.110.960872","article-title":"Stent: the man and word behind the coronary metal prosthesis","volume":"4","author":"Roguin","year":"2011","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref99","doi-asserted-by":"publisher","first-page":"FSO30","DOI":"10.4155\/FSO.15.28","article-title":"The impact of blood shear rate on arterial thrombus formation","volume":"1","author":"Sakariassen","year":"2015","journal-title":"Future Sci. OA"},{"key":"ref100","doi-asserted-by":"publisher","first-page":"2498","DOI":"10.3390\/MA14102498","article-title":"Cardiovascular stents: a review of past, current, and emerging devices","volume":"14","author":"Scafa Udri\u0219te","year":"2021","journal-title":"Materials"},{"key":"ref101","doi-asserted-by":"publisher","first-page":"2430","DOI":"10.1161\/hc4501.099307","article-title":"Catheter stimulation of cardiac parasympathetic nerves in humans. A novel approach to the cardiac autonomic nervous system","volume":"104","author":"Schauerte","year":"2001","journal-title":"Circulation"},{"key":"ref102","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.1111\/J.1540-8167.1999.TB00210.X","article-title":"Transvenous parasympathetic cardiac nerve stimulation: an approach for stable sinus rate control","volume":"10","author":"Schauerte","year":"1999","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref103","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1111\/J.1540-8159.1986.TB06612.X","article-title":"Catheter ablation for patients with cardiac arrhythmias","volume":"9","author":"Scheinman","year":"1986","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref104","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2016.3.FOCUS15635","article-title":"The evolution of endovascular electroencephalography: historical perspective and future applications","volume":"40","author":"Sefcik","year":"2016","journal-title":"Neurosurg. Focus"},{"key":"ref105","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1161\/CIRCULATIONAHA.106.666826","article-title":"Late stent thrombosis: a nuisance in both bare metal and drug-eluting stents","volume":"115","author":"Serruys","year":"2007","journal-title":"Circulation"},{"key":"ref106","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/J.BIOS.2010.06.073","article-title":"Towards a self-reporting coronary artery stent\u2014measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques","volume":"26","author":"Shedden","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref107","doi-asserted-by":"publisher","first-page":"121","DOI":"10.3390\/NEUROSCI6040121","article-title":"Stroke Management in the Intensive Care Unit: ischemic and hemorrhagic stroke care","volume":"6","author":"Si\u010d","year":"2025","journal-title":"NeuroSci"},{"key":"ref108","doi-asserted-by":"publisher","first-page":"E3","DOI":"10.3171\/2020.4.FOCUS20186","article-title":"A systematic review of endovascular stent-electrode arrays, a minimally invasive approach to brain-machine interfaces","volume":"49","author":"Soldozy","year":"2020","journal-title":"Neurosurg. Focus"},{"key":"ref109","doi-asserted-by":"publisher","first-page":"e70149","DOI":"10.1111\/ENE.70149","article-title":"Raised intracranial pressure in seizures induced by electroconvulsive therapy","volume":"32","author":"Spoor","year":"2025","journal-title":"Eur. J. Neurol."},{"key":"ref110","volume-title":"StatPearls","author":"Stauffer","year":"2023"},{"key":"ref111","first-page":"1214","article-title":"Intracranial electroencephalographic and evoked-potential recording from intravascular guide wires","volume":"16","author":"Stoeter","year":"1995","journal-title":"Am. J. Neuroradiol."},{"key":"ref112","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/J.ACTBIO.2023.01.026","article-title":"Flexible IrOx neural electrode for mouse vagus nerve stimulation","volume":"159","author":"Sun","year":"2023","journal-title":"Acta Biomater."},{"key":"ref113","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1109\/JMEMS.2006.880229","article-title":"Micromachined antenna stents and cuffs for monitoring intraluminal pressure and flow","volume":"15","author":"Takahata","year":"2006","journal-title":"J. Microelectromech. Syst."},{"key":"ref114","doi-asserted-by":"publisher","first-page":"026011","DOI":"10.1088\/1741-2560\/11\/2\/026011","article-title":"Computational modeling of an endovascular approach to deep brain stimulation","volume":"11","author":"Teplitzky","year":"2014","journal-title":"J. Neural Eng."},{"key":"ref115","doi-asserted-by":"publisher","first-page":"011001","DOI":"10.1088\/1741-2552\/ACB086","article-title":"Making a case for endovascular approaches for neural recording and stimulation","volume":"20","author":"Thielen","year":"2023","journal-title":"J. Neural Eng."},{"key":"ref116","volume-title":"StatPearls","author":"Tucker","year":"2023"},{"key":"ref117","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1093\/med\/9780198755777.003.0001","volume-title":"The ESC Textbook of Vascular Biology","author":"van Thiel","year":"2017"},{"key":"ref118","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.4244\/EIJY14M12_02","article-title":"Twelve-month results of the rapid renal sympathetic denervation for resistant hypertension using the OneShot\u2122 ablation system (RAPID) study","volume":"10","author":"Verheye","year":"2015","journal-title":"EuroIntervention"},{"key":"ref119","doi-asserted-by":"publisher","first-page":"e10116","DOI":"10.1002\/MDS3.10116","article-title":"Perspectives on smart stents with sensors: from conventional permanent to novel bioabsorbable smart stent technologies","volume":"3","author":"Vishnu","year":"2020","journal-title":"Med. Devices Sens."},{"key":"ref120","doi-asserted-by":"publisher","first-page":"9442","DOI":"10.1038\/s41467-024-53720-5","article-title":"Intravascular delivery of an ultraflexible neural electrode array for recordings of cortical spiking activity","volume":"15","author":"Wang","year":"2024","journal-title":"Nat. Commun."},{"key":"ref121","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1016\/j.jcin.2019.02.050","article-title":"Renal denervation for treating hypertension: current scientific and clinical evidence","volume":"12","author":"Weber","year":"2019","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref122","doi-asserted-by":"publisher","first-page":"035010","DOI":"10.1088\/2057-1976\/ADC266","article-title":"Fabrication of micro-wire stent electrode as a minimally invasive endovascular neural interface for vascular electrocorticography using laser ablation method","volume":"11","author":"Wen","year":"2025","journal-title":"Biomed. Phys. Eng. Express"},{"key":"ref123","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/J.CHEST.2016.01.023","article-title":"Risk of procedural hemorrhage","volume":"150","author":"Wolfe","year":"2016","journal-title":"Chest"},{"key":"ref124","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1038\/s44172-026-00617-4","article-title":"A wireless power transfer system for leadless endovascular electrocorticography","volume":"5","author":"Xu","year":"2026","journal-title":"Communications Engineering"},{"key":"ref125","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1126\/SCIENCE.ADH3916","article-title":"Ultraflexible endovascular probes for brain recording through micrometer-scale vasculature","volume":"381","author":"Zhang","year":"2023","journal-title":"Science (1979)"}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1933040\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T12:04:34Z","timestamp":1790165074000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1933040\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":125,"alternative-id":["10.3389\/fnins.2026.1933040"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2026.1933040","relation":{},"ISSN":["1662-453X"],"issn-type":[{"value":"1662-453X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]},"article-number":"1933040"}}