{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T06:56:13Z","timestamp":1790751373104,"version":"4.1.0"},"reference-count":32,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Neurosci."],"abstract":"<jats:p>Intraoperative visual evoked potential (VEP) monitoring has a reputation for being unreliable, and much of that belongs to P100 amplitude. Amplitude shifts with electrode position, anesthetic depth, and dipole geometry. Practice has nonetheless tended to lean on amplitude, and to treat latency as the weaker of the two. Neuroendovascular procedures give reason to shift that emphasis. During open surgery there can be a mixture of direct and ischemic neural injury, whereas in an endovascular procedure the brain is not dissected and the monitored pathway is threatened almost exclusively through perfusion. Oligodendrocytes are more vulnerable to ischemia than neurons, so myelinated conduction may slow before neurons are lost, and latency may prolong before amplitude falls. We first asked whether latency can be measured reliably enough. In a retrospective series of 49 eyes from 28 patients, the median spatial variability index across O1, Oz, and O2 was 2.10% for P100 latency and 40.9% for amplitude. Amplitude varied more than latency in 47 of 49 eyes and in all 28 patients. Latency behaves as a stable temporal measure of signal arrival, amplitude as a spatially sampled field measure. Some evidence for this exists in intraprocedural somatosensory monitoring. In an exploratory analysis of successfully reperfused thrombectomy patients, tree-based models separated 90-day functional outcome more consistently and efficiently by latency than by amplitude. If VEP latency behaves the same way, monitoring need not depend on the parameter that is hardest to trust, and VEP could be used actively in these procedures. We therefore propose that reproducible P100 latency prolongation may mark evolving visual pathway ischemia, and specify three studies that would test it. The first measures the temporal variability of intraoperative P100 latency and reports the smallest change it can resolve. That number sets the floor for any alarm threshold, including one below the conventional 10%. The second follows retrochiasmal perfusion-risk procedures with concurrent electroretinography, asking whether latency prolongation tracks angiographic events and precedes major amplitude loss. The third separates retinal from central contributions in ophthalmic-territory procedures. The present data establish spatial robustness only. Temporal stability and ischemia detection are the endpoints of those studies.<\/jats:p>","DOI":"10.3389\/fnins.2026.1956999","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T06:05:46Z","timestamp":1790748346000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Spatial robustness of P100 latency compared with amplitude: a data-driven rationale for visual pathway monitoring during neuroendovascular procedures"],"prefix":"10.3389","volume":"20","author":[{"given":"Su Ji","family":"Lee","sequence":"first","affiliation":[{"name":"Department and Research Institute of Rehabilitation Medicine, Yonsei University College of Medicine","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Chul","family":"Jin","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Inje University Haeundae Paik Hospital","place":["Busan, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Tae","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Inje University Haeundae Paik Hospital","place":["Busan, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hee-Eun","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Rehabilitation Medicine, Inje University Haeundae Paik Hospital","place":["Busan, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang-Ku","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Konkuk University Medical Center","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minjae","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Seoul National University Bundang Hospital (SNUBH)","place":["Seongnam-si, Gyeonggi-do, Republic of Korea"]},{"name":"Department of Neurosurgery, Daegu Good Morning Hospital","place":["Daegu, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"eadr4661","DOI":"10.1126\/science.adr4661","article-title":"Myelin sheaths in the central nervous system can withstand damage and dynamically remodel","volume":"391","author":"Arafa","year":"2026","journal-title":"Science"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1161\/01.str.12.6.723","article-title":"Thresholds in cerebral ischemia - the ischemic penumbra","volume":"12","author":"Astrup","year":"1981","journal-title":"Stroke"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1523\/JNEUROSCI.22-02-00455.2002","article-title":"Selective vulnerability of late oligodendrocyte progenitors to hypoxia-ischemia","volume":"22","author":"Back","year":"2002","journal-title":"J. Neurosci."},{"key":"ref4","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1136\/pn-2024-004179","article-title":"Somatosensory evoked potentials: technique, interpretation and clinical applications","volume":"25","author":"Calma","year":"2025","journal-title":"Pract. Neurol."},{"key":"ref5","doi-asserted-by":"publisher","first-page":"405","DOI":"10.3389\/fneur.2017.00405","article-title":"Molecular disorganization of axons adjacent to human cortical microinfarcts","volume":"8","author":"Coban","year":"2017","journal-title":"Front. Neurol."},{"key":"ref6","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1523\/JNEUROSCI.20-01-00034.2000","article-title":"Rapid ischemic cell death in immature oligodendrocytes: a fatal glutamate release feedback loop","volume":"20","author":"Fern","year":"2000","journal-title":"J. Neurosci."},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.3174\/ajnr.A8024","article-title":"DWI-detected ischemic lesions after endovascular treatment for cerebral aneurysms: an updated systematic review and meta-analysis","volume":"44","author":"Habtezghi","year":"2023","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref8","doi-asserted-by":"publisher","first-page":"292","DOI":"10.4132\/jptm.2017.02.17","article-title":"An experimental infarct targeting the internal capsule: histopathological and ultrastructural changes","volume":"51","author":"Han","year":"2017","journal-title":"J. Pathol. Transl. Med."},{"key":"ref9","doi-asserted-by":"publisher","first-page":"127","DOI":"10.4097\/kjae.2017.70.2.127","article-title":"Intraoperative monitoring of flash visual evoked potential under general anesthesia","volume":"70","author":"Hayashi","year":"2017","journal-title":"Korean J. Anesthesiol."},{"key":"ref10","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1097\/WCO.0000000000000149","article-title":"The back and forth of axonal injury and repair after stroke","volume":"27","author":"Hinman","year":"2014","journal-title":"Curr. Opin. Neurol."},{"key":"ref11","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1093\/brain\/awu398","article-title":"Molecular disorganization of axons adjacent to human lacunar infarcts","volume":"138","author":"Hinman","year":"2015","journal-title":"Brain"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1161\/STROKEAHA.111.632943","article-title":"Ischemic cerebral damage: an appraisal of synaptic failure","volume":"43","author":"Hofmeijer","year":"2012","journal-title":"Stroke"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1186\/s12883-021-02315-4","article-title":"Intraoperative monitoring of visual evoked potentials in patients undergoing transsphenoidal surgery for pituitary adenoma: a systematic review","volume":"21","author":"Jashek-Ahmed","year":"2021","journal-title":"BMC Neurol."},{"key":"ref14","doi-asserted-by":"publisher","first-page":"3087","DOI":"10.3969\/j.issn.1673-5374.2013.33.002","article-title":"Monitoring somatosensory evoked potentials in spinal cord ischemia-reperfusion injury","volume":"8","author":"Ji","year":"2013","journal-title":"Neural Regen. Res."},{"key":"ref15","doi-asserted-by":"crossref","DOI":"10.1016\/B978-0-12-815000-9.00004-6","article-title":"Neurophysiology of the Visual System: Basics and Intraoperative Neurophysiology Techniques","author":"Kodama","year":"2020"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"jnis-2026-025774","DOI":"10.1136\/jnis-2026-025774","article-title":"Intra-procedural SSEP latency stratifies functional outcome after successful endovascular thrombectomy","author":"Lee","year":"2026","journal-title":"J. Neurointerv. Surg."},{"key":"ref17","doi-asserted-by":"publisher","first-page":"490","DOI":"10.3171\/jns.1984.60.3.0490","article-title":"Alteration of somatosensory evoked potentials in response to global ischemia","volume":"60","author":"Lesnick","year":"1984","journal-title":"J. Neurosurg."},{"key":"ref18","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1038\/s41593-023-01558-3","article-title":"Oligodendrocyte-axon metabolic coupling is mediated by extracellular K+ and maintains axonal health","volume":"27","author":"Looser","year":"2024","journal-title":"Nat. Neurosci."},{"key":"ref19","doi-asserted-by":"publisher","first-page":"3421","DOI":"10.1007\/s00701-023-05778-1","article-title":"Reliability of intraoperative visual evoked potentials (iVEPs) in monitoring visual function during endoscopic transsphenoidal surgery","volume":"165","author":"Mattogno","year":"2023","journal-title":"Acta Neurochir."},{"key":"ref20","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1038\/nm0398-291","article-title":"Oligodendrocytes from forebrain are highly vulnerable to AMPA\/kainate receptor-mediated excitotoxicity","volume":"4","author":"McDonald","year":"1998","journal-title":"Nat. Med."},{"key":"ref21","doi-asserted-by":"publisher","first-page":"761263","DOI":"10.3389\/fneur.2022.761263","article-title":"Diagnostic impact of monitoring visual evoked potentials to prevent visual complications during endovascular treatment for intracranial aneurysm","volume":"13","author":"Nakagawa","year":"2022","journal-title":"Front. Neurol."},{"key":"ref22","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1038\/nature09614","article-title":"Myelination and support of axonal integrity by glia","volume":"468","author":"Nave","year":"2010","journal-title":"Nature"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/j.wneu.2020.04.196","article-title":"Visual evoked potentials and intraoperative awakening in ophthalmic artery sacrifice during aneurysm clipping: 2 cases and literature review","volume":"139","author":"Nowicki","year":"2020","journal-title":"World Neurosurg."},{"key":"ref24","doi-asserted-by":"publisher","first-page":"388","DOI":"10.21037\/atm-22-4586","article-title":"New frontiers in intraoperative neurophysiologic monitoring: a narrative review","volume":"11","author":"Oliva","year":"2023","journal-title":"Ann. Transl. Med."},{"key":"ref25","doi-asserted-by":"publisher","first-page":"290","DOI":"10.3109\/02688697.2011.603854","article-title":"Detection of ophthalmic artery occlusion by visual evoked potential during carotid-ophthalmic artery aneurysm clipping","volume":"26","author":"Ota","year":"2012","journal-title":"Br. J. Neurosurg."},{"key":"ref26","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s10143-023-02160-8","article-title":"Brain retraction injury: systematic literature review","volume":"46","author":"Roca","year":"2023","journal-title":"Neurosurg. Rev."},{"key":"ref27","doi-asserted-by":"publisher","first-page":"720","DOI":"10.3171\/2024.1.JNS232118","article-title":"How should visual function monitoring be performed and interpreted in surgery for suprasellar tumors?","volume":"141","author":"Sato","year":"2024","journal-title":"J. Neurosurg."},{"key":"ref28","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10633-025-10042-1","article-title":"ISCEV standard for clinical visual evoked potentials (2025 update)","volume":"151","author":"\u0160u\u0161tar Habjan","year":"2025","journal-title":"Doc. Ophthalmol."},{"key":"ref29","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1042\/AN20130025","article-title":"Node of Ranvier disruption as a cause of neurological diseases","volume":"5","author":"Susuki","year":"2013","journal-title":"ASN Neuro"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.3171\/2023.9.JNS23457","article-title":"Efficacy of intraoperative visual evoked potential amplitude reduction in predicting visual outcome after extended endoscopic endonasal resection of craniopharyngiomas","volume":"140","author":"Tao","year":"2024","journal-title":"J. Neurosurg."},{"key":"ref31","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1097\/WNP.0b013e31823e954e","article-title":"Neurophysiologic intraoperative monitoring of olfactory and optic nerves","volume":"28","author":"Thirumala","year":"2011","journal-title":"J. Clin. Neurophysiol."},{"key":"ref32","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1007\/s10877-024-01201-x","article-title":"Intraoperative somatosensory evoked potential (SEP) monitoring: an updated position statement by the American Society of Neurophysiological Monitoring","volume":"38","author":"Toleikis","year":"2024","journal-title":"J. Clin. Monit. Comput."}],"container-title":["Frontiers in Neuroscience"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1956999\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T06:05:48Z","timestamp":1790748348000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2026.1956999\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":32,"alternative-id":["10.3389\/fnins.2026.1956999"],"URL":"https:\/\/doi.org\/10.3389\/fnins.2026.1956999","relation":{},"ISSN":["1662-453X"],"issn-type":[{"value":"1662-453X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"article-number":"1956999"}}