{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T17:09:25Z","timestamp":1794330565030,"version":"4.9.0"},"reference-count":56,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100021171","name":"Basic and Applied Basic Research Foundation of Guangdong Province","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100021171","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012151","name":"Sanming Project of Medicine in Shenzhen","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012151","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Oncol."],"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>Our study aims to estimate intra-fraction six-dimensional (6D) tumor motion with rotational correction and the related correlations between motions of different degrees of freedom (DoF), as well as quantify sufficient anisotropic clinical target volume (CTV) to planning target volume (PTV) margins during stereotactic body radiotherapy (SBRT) of liver cancer with fiducial tracking technique.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A cohort of 12 patients who were implanted with 3 or 4 golden markers were included in this study, and 495 orthogonal kilovoltage (kV) pairs of images acquired during the first fraction were used to extract the spacial position of each golden marker. Translational and rotational motions of tumor were calculated based on the marker coordinates by using an iterative closest point (ICP) algorithm. Moreover, the Pearson product-moment correlation coefficients (<jats:italic>r<\/jats:italic>) were applied to quantify the correlations between motions with different degrees of freedom (DoFs). The population mean displacement (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" display=\"inline\" id=\"im1\"><mml:mrow><mml:mover accent=\"true\"><mml:mrow><mml:msub><mml:mi>M<\/mml:mi><mml:mi>P<\/mml:mi><\/mml:msub><\/mml:mrow><mml:mo stretchy=\"true\">\u00af<\/mml:mo><\/mml:mover><\/mml:mrow><\/mml:math><\/jats:inline-formula>), systematic error (\u03a3) and random error (<jats:italic>\u03c3<\/jats:italic>) were obtained to calculate PTV margins based on published recipes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean translational variability of tumors were 0.56, 1.24 and 3.38\u00a0mm in the left-right (LR, <jats:italic>X<\/jats:italic>), anterior-posterior (AP, <jats:italic>Y<\/jats:italic>), and superior-inferior (SI, <jats:italic>Z<\/jats:italic>) directions, respectively. The average rotational angles <jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>X<\/jats:italic><\/jats:sub> , <jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>Y<\/jats:italic><\/jats:sub> and <jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>Z<\/jats:italic><\/jats:sub> around the three coordinate axes were 0.88, 1.24 and 1.12, respectively. (|<jats:italic>r<\/jats:italic>|&amp;gt;0.4) was obtainted between <jats:italic>Y<\/jats:italic> -<jats:italic>Z<\/jats:italic> , <jats:italic>Y<\/jats:italic> - <jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>Z<\/jats:italic><\/jats:sub> , <jats:italic>Z<\/jats:italic> -<jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>Z<\/jats:italic><\/jats:sub> and <jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>X<\/jats:italic><\/jats:sub> - <jats:italic>\u03b8<\/jats:italic><jats:sub><jats:italic>Y<\/jats:italic><\/jats:sub> . The PTV margins calculated based on 13 published recipes in X, Y, and Z directions were 1.08, 2.26 and 5.42\u00a0mm, and the 95% confidence interval (CI) of them were (0.88,1.28), (1.99,2.53) and (4.78,6.05), respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The maximum translational motion was in SI direction, and the largest correlation coefficient of <jats:italic>Y<\/jats:italic>-<jats:italic>Z<\/jats:italic> was obtained. We recommend margins of 2, 3 and 7\u00a0mm in LR, AP and SI directions, respectively.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fonc.2022.1021119","type":"journal-article","created":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T06:15:42Z","timestamp":1668579342000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Quantifying 6D tumor motion and calculating PTV margins during liver stereotactic radiotherapy with fiducial tracking"],"prefix":"10.3389","volume":"12","author":[{"given":"Xingru","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhitao","family":"Dai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meiling","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xueling","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanfan","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,11,16]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.3322\/caac.21660","article-title":"Global cancer statistics 2020: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"71","author":"Sung","year":"2021","journal-title":"CA: A Cancer J Clin"},{"key":"B2","doi-asserted-by":"publisher","DOI":"10.3892\/mco.2014.304","article-title":"Stereotactic body radiotherapy combined with transarterial chemoembolization for huge (\u226510 cm) hepatocellular carcinomas: A clinical study","volume":"2","author":"Zhong","year":"2014","journal-title":"Mol Clin Oncol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"399","DOI":"10.3109\/0284186x.2013.820342","article-title":"Stereotactic body radiotherapy for small hepatocellular carcinoma: A retrospective outcome analysis in 185 patients","volume":"53","author":"Sanuki","year":"2013","journal-title":"Acta Oncol"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717x-9-120","article-title":"The efficacy of stereotactic body radiation therapy on huge hepatocellular carcinoma unsuitable for other local modalities","volume":"9","author":"Que","year":"2014","journal-title":"Radiat Oncol"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2015.02.007","article-title":"Treatment variables related to liver toxicity in patients with hepatocellular carcinoma, child-pugh class a and b enrolled in a phase 1-2 trial of stereotactic body radiation therapy","volume":"5","author":"Lasley","year":"2015","journal-title":"Pract Radiat Oncol"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2014.05.002","article-title":"Outcomes following definitive stereotactic body radiotherapy for patients with child-pugh b or c hepatocellular carcinoma","volume":"111","author":"Culleton","year":"2014","journal-title":"Radiother Oncol"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.06.063","article-title":"Prostate planning treatment volume margin calculation based on the ExacTrac x-ray 6d image-guided system: Margins for various clinical implementations","volume":"69","author":"Alonso-Arrizabalaga","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B8","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1186\/s12885-016-2512-x","article-title":"Clinical outcomes and prognostic factors of cyberknife stereotactic body radiation therapy for unresectable hepatocellular carcinoma","volume":"16","author":"Que","year":"2016","journal-title":"BMC Cancer"},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.09.008","article-title":"Interfraction and intrafraction changes in amplitude of breathing motion in stereotactic liver radiotherapy","volume":"77","author":"Case","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v3i3.2561","article-title":"Ptv margin determination in conformal srt of intracranial lesions","volume":"3","author":"Parker","year":"2002","journal-title":"J Appl Clin Med Phys"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2012.12.017","article-title":"Three-dimensional, time-resolved, intrafraction motion monitoring throughout stereotactic liver radiation therapy on a conventional linear accelerator","volume":"86","author":"Worm","year":"2013","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B12","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.ijrobp.2014.05.007","article-title":"Quantifying rigid and nonrigid motion of liver tumors during stereotactic body radiation therapy","volume":"90","author":"Xu","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B13","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(03)00082-8","article-title":"Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system","volume":"56","author":"Kitamura","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(98)00468-4","article-title":"Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability","volume":"43","author":"Stroom","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B15","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1053\/j.semradonc.2003.10.003","article-title":"Error and margins in radiotherapy","volume":"14","author":"Herk","year":"2004","journal-title":"Semin Radiat Oncol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1038\/nrclinonc.2009.188","article-title":"Stereotactic body radiation therapy: a novel treatment modality","volume":"7","author":"Lo","year":"2010","journal-title":"Nat Rev Clin Oncol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/j.rpor.2014.12.004","article-title":"Dependence of the safe rectum dose on the CTV-PTV margin size and treatment technique","volume":"20","author":"Kuko\u0142owicz","year":"2015","journal-title":"Rep Pract Oncol Radiother"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20140459","article-title":"Image-guided radiotherapy of the prostate using daily CBCT: the feasibility and likely benefit of implementing a margin reduction","volume":"87","author":"Maund","year":"2014","journal-title":"Br J Radiol"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/58\/21\/7733","article-title":"An assessment of PTV margin based on actual accumulated dose for prostate cancer radiotherapy","volume":"58","author":"Wen","year":"2013","journal-title":"Phys Med Biol"},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2005.03.072","article-title":"Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control","volume":"62","author":"Dawson","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.03.026","article-title":"Assessment of residual error in liver position using kv cone-beam computed tomography for liver cancer high-precision radiation therapy","volume":"66","author":"Hawkins","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B22","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1002\/acm2.12220","article-title":"Intra- and inter-fractional liver and lung tumor motions treated with sbrt under active breathing control","volume":"19","author":"Lu","year":"2017","journal-title":"J Appl Clin Med Phys"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.09.045","article-title":"Accumulated dose in liver stereotactic body radiotherapy: Positioning, breathing, and deformation effects","volume":"83","author":"Velec","year":"2011","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B24","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.ijrobp.2012.09.014","article-title":"Planning 4-dimensional computed tomography (4dct) cannot adequately represent daily intrafractional motion of abdominal tumors","volume":"85","author":"Ge","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2017.09.001","article-title":"The long- and short-term variability of breathing induced tumor motion in lung and liver over the course of a radiotherapy treatment","volume":"126","author":"Dhont","year":"2017","journal-title":"Radioth Oncol"},{"key":"B26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.03.010","article-title":"Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver","volume":"71","author":"Wunderink","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B27","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2014.05.007","article-title":"Kilovoltage intrafraction motion monitoring and target dose reconstruction for stereotactic volumetric modulated arc therapy of tumors in the liver","volume":"111","author":"Poulsen","year":"2014","journal-title":"Radioth Oncol"},{"key":"B28","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2016.07.007","article-title":"Evaluation of reproducibility of tumor repositioning during multiple breathing cycles for liver stereotactic body radiotherapy treatment","volume":"22","author":"Bedos","year":"2016","journal-title":"Rep Pract Oncol Radiother"},{"key":"B29","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1088\/1361-6560\/aacdda","article-title":"Geometric and dosimetric comparison of four intrafraction motion adaptation strategies for stereotactic liver radiotherapy","volume":"63","author":"Nankali","year":"2018","journal-title":"Phys Med Biol"},{"key":"B30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2018.02.010","article-title":"A prospective cohort study on gated stereotactic liver radiotherapy based on continuous internal electromagnetic motion monitoring","volume":"101","author":"Worm","year":"2018","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B31","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1002\/acm2.12292","article-title":"Evaluation of the intra- and interfractional tumor motion and variability by fiducial-based real-time tracking in liver stereotactic body radiation therapy","volume":"19","author":"Liang","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"B32","doi-asserted-by":"publisher","DOI":"10.1111\/1754-9485.13020","article-title":"Factors affecting target motion in stereotactic body radiotherapy of liver cancer using cyberknife","volume":"64","author":"Lo","year":"2020","journal-title":"J Med Imaging Radiat Oncol"},{"key":"B33","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2019.06.001","article-title":"Retrospective assessment of a single fiducial marker tracking regimen with robotic stereotactic body radiation therapy for liver tumours","volume":"24","author":"Nakayama","year":"2019","journal-title":"Rep Pract Oncol Radiother"},{"key":"B34","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1186\/s13014-019-1401-2","article-title":"Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm","volume":"14","author":"Li","year":"2019","journal-title":"Radiat Oncol"},{"key":"B35","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2020.11.036","article-title":"Quantification of intrafraction and interfraction tumor motion amplitude and prediction error for different liver tumor trajectories in cyberknife synchrony tracking","volume":"109","author":"Zhang","year":"2020","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2012.08.016","article-title":"Active breathing control in combination with ultrasound imaging: A feasibility study of image guidance in stereotactic body radiation therapy of liver lesions","volume":"85","author":"Bloemen-van Gurp","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B37","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.ejmp.2019.08.003","article-title":"Ultrasound-based repositioning and real-time monitoring for abdominal sbrt in dibh","volume":"65","author":"Boda-Heggemann","year":"2019","journal-title":"Phys Med"},{"key":"B38","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2020.573279","article-title":"Feasibility of optical surface-guidance for position verification and monitoring of stereotactic body radiotherapy in deep-inspiration breath-hold","volume":"10","author":"Naumann","year":"2020","journal-title":"Front Oncol"},{"key":"B39","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1186\/s13014-022-02079-2","article-title":"Effect of intrafraction adaptation on ptv margins for mri guided online adaptive radiotherapy for rectal cancer","volume":"17","author":"Kensen","year":"2022","journal-title":"Radiat Oncol"},{"key":"B40","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2016.06.004","article-title":"Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. concerns about technique and preliminary clinical results","volume":"22","author":"Llacer-Moscardo","year":"2017","journal-title":"Rep Pract Oncol Radiother"},{"key":"B41","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2012.03.006","article-title":"Intrafraction verification of gated RapidArc by using beam-level kilovoltage x-ray images","volume":"83","author":"Li","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B42","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2015.02.055","article-title":"Verification of accuracy of CyberKnife tumor-tracking radiation therapy using patient-specific lung phantoms","volume":"92","author":"Jung","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B43","doi-asserted-by":"publisher","DOI":"10.1118\/1.4907956","article-title":"Comparison between target margins derived from 4dct scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery","volume":"42","author":"Descovich","year":"2015","journal-title":"Med Phys"},{"key":"B44","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-11","article-title":"Adequacy of inhale\/exhale breathhold CT based ITV margins and image-guided registration for free-breathing pancreas and liver SBRT","volume":"9","author":"Yang","year":"2014","journal-title":"Radiat Oncol"},{"key":"B45","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-014-0229-z","article-title":"PTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers","volume":"9","author":"Oehler","year":"2014","journal-title":"Radiat Oncol"},{"key":"B46","doi-asserted-by":"publisher","DOI":"10.1118\/1.597745","article-title":"Target margins for random geometrical treatment uncertainties in conformal radiotherapy","volume":"23","author":"Bel","year":"1996","journal-title":"Med Phys"},{"key":"B47","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(99)00117-0","article-title":"Planning target volumes for radiotherapy: how much margin is needed","volume":"44","author":"Antolak","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B48","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/11\/315","article-title":"The width of margins in radiotherapy treatment plans","volume":"45","author":"McKenzie","year":"2000","journal-title":"Phys Med Biol"},{"key":"B49","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(00)00518-6","article-title":"The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy","volume":"47","author":"van Herk","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B50","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(01)02805-X","article-title":"Inclusion of geometric uncertainties in treatment plan evaluation","volume":"52","author":"van Herk","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B51","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.08.004","article-title":"Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance","volume":"74","author":"Sonke","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B52","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1186\/s13014-017-0859-z","article-title":"A novel cbct-based method for derivation of ctv-ptv margins for prostate and pelvic lymph nodes treated with stereotactic ablative radiotherapy","volume":"12","author":"Lyons","year":"2017","journal-title":"Radiat Oncol"},{"key":"B53","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.02.048","article-title":"Incidence of changes in respiration-induced tumor motion and its relationship with respiratory surrogates during individual treatment fractions","volume":"82","author":"Malinowski","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"B54","doi-asserted-by":"publisher","DOI":"10.1017\/s0020268100013068","article-title":"Karl Pearson's early statistical papers","volume":"75","author":"WP","year":"1949","journal-title":"J Inst Actuar"},{"key":"B55","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.radonc.2021.11.022","article-title":"A systematic review and meta-analysis of liver tumor position variability during SBRT using various motion management and IGRT strategies","volume":"166","author":"Sharma","year":"2022","journal-title":"Radiother Oncol"},{"key":"B56","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/10.1186\/s13014-017-0799-7","article-title":"Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers","volume":"12","author":"Shimohigashi","year":"2017","journal-title":"Radiat Oncol"}],"container-title":["Frontiers in Oncology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fonc.2022.1021119\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T06:15:45Z","timestamp":1668579345000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fonc.2022.1021119\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,16]]},"references-count":56,"alternative-id":["10.3389\/fonc.2022.1021119"],"URL":"https:\/\/doi.org\/10.3389\/fonc.2022.1021119","relation":{"has-part":[{"id-type":"doi","id":"https:\/\/doi.org\/10.3389\/fonc.2022.1021119.s001","asserted-by":"subject"}]},"ISSN":["2234-943X"],"issn-type":[{"value":"2234-943X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,16]]},"article-number":"1021119"}}