{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T05:35:56Z","timestamp":1768282556452,"version":"3.49.0"},"reference-count":34,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,2,10]],"date-time":"2022-02-10T00:00:00Z","timestamp":1644451200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Pediatr."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Locking plate (LP) is a good choice in the treatment of length-unstable femoral shaft fracture in children. Monolateral external fixator (EF) has been reported for this condition for decades. This study aims to compare the clinical outcomes of school-aged children with length-unstable femoral shaft fracture treated with LP <jats:italic>vs<\/jats:italic>. EF.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Patients aged 5\u201311 years old with length-unstable femoral shaft fractures treated at our institute from January 2014 to January 2018 were retrospectively reviewed and categorized into LP and EF groups. The preoperative data, including baseline information of the patients, radiographic parameters, and types of surgical procedure, were collected from the hospital database, and postoperative data, including complications, were collected during the follow-up visits.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Overall, 36 patients (average, 8.2 \u00b1 2.1 years; male, 20; female, 16) in the LP group and 35 patients (average, 8.3 \u00b1 2.3 years; male 20, female 15) in the EF group were included. There was significantly less operative time for EF (45.4 \u00b1 7.8 min) compared with LP (67.8 \u00b1 11.3 min) (<jats:italic>P<\/jats:italic> &amp;lt; 0.001). As for the frequency of fluoroscopy, there was a significant difference between the EF (13.9 \u00b1 2.4) and LP (16.5 \u00b1 3.2) groups (<jats:italic>p<\/jats:italic> &amp;lt; 0.001). The rate of major complications was not significantly different between these two groups. There was a significant difference between the EF group (11.2 \u00b1 5.8 mm) and the LP group (7.5 \u00b1 1.6 mm) group concerning limb length discrepancy (<jats:italic>P<\/jats:italic> &amp;lt; 0.001).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Both LP and EF produce satisfactory outcomes in school-aged children with length unstable femoral shaft fractures. External fixation remains a viable choice without the necessity of secondary surgery for hardware removal.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fped.2021.799487","type":"journal-article","created":{"date-parts":[[2022,2,10]],"date-time":"2022-02-10T05:26:25Z","timestamp":1644470785000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Operative Choice for Length-Unstable Femoral Shaft Fracture in School-Aged Children: Locking Plate vs. Monolateral External Fixator"],"prefix":"10.3389","volume":"9","author":[{"given":"Pan","family":"Hong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saroj","family":"Rai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruikang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,2,10]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.ocl.2017.11.008","article-title":"Pediatric orthopedic trauma: an evidence-based approach","volume":"49","author":"Hubbard","year":"2018","journal-title":"Orthop Clin North Am."},{"key":"B2","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1097\/BPO.0000000000000982","article-title":"Pediatric femoral shaft fractures: a multicenter review of the aaos clinical practice guidelines before and after 2009","volume":"39","author":"Roaten","year":"2019","journal-title":"J Pediatr Orthop."},{"key":"B3","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1007\/s00590-013-1234-x","article-title":"B\u00fclb\u00fcl M. Which treatment option for paediatric femoral fractures in school-aged children: elastic nail or spica casting?","volume":"24","author":"Say","year":"2014","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"e20796","DOI":"10.1097\/MD.0000000000020796","article-title":"The optimal choice for length unstable femoral shaft fracture in school-aged children: a comparative study of elastic stable intramedullary nail and submuscular plate","volume":"99","author":"Li","year":"2020","journal-title":"Medicine."},{"key":"B5","doi-asserted-by":"publisher","first-page":"S29","DOI":"10.1097\/BPO.0000000000000761","article-title":"Klingele KE. Bridge plating length-unstable pediatric femoral shaft fractures","volume":"36","author":"Sutphen","year":"2016","journal-title":"J Pediatr Orthop."},{"key":"B6","doi-asserted-by":"publisher","first-page":"3814","DOI":"10.1007\/s11999-014-3554-5","article-title":"External fixation for closed pediatric femoral shaft fractures: where are we now?","volume":"472","author":"Kong","year":"2014","journal-title":"Clin Orthop Relat Res."},{"key":"B7","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1097\/BPO.0b013e3181a53b59","article-title":"Antegrade intramedullary nailing of pediatric femoral fractures using an interlocking pediatric femoral nail and a lateral trochanteric entry point","volume":"29","author":"Keeler","year":"2009","journal-title":"J Pediatr Orthop."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1122","DOI":"10.2106\/JBJS.H.01735","article-title":"Femoral fractures in adolescents: a comparison of four methods of fixation","volume":"92","author":"Ramseier","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"B9","doi-asserted-by":"publisher","first-page":"353","DOI":"10.3928\/01477447-20160719-03","article-title":"Pediatric diaphyseal femur fractures: submuscular plating compared with intramedullary nailing","volume":"39","author":"Sutphen","year":"2016","journal-title":"Orthopedics."},{"key":"B10","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1097\/bpo.0b013e31815ff301","article-title":"Locking plate fixation for pediatric femur fractures","volume":"28","author":"Hedequist","year":"2008","journal-title":"J Pediatr Orthop."},{"key":"B11","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1097\/BPB.0000000000000336","article-title":"A meta-analysis of flexible intramedullary nailing versus external fixation for pediatric femoral shaft fractures","volume":"25","author":"Guo","year":"2016","journal-title":"J Pediatr Orthop B."},{"key":"B12","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s10195-021-00569-9","article-title":"Risk factors for refracture of the femoral shaft in children after removal of external fixation","volume":"22","author":"Guo","year":"2021","journal-title":"J Orthop Traumatol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1080\/17453674.2016.1258533","article-title":"The AO pediatric comprehensive classification of long bone fractures (PCCF)","volume":"88","author":"Joeris","year":"2017","journal-title":"Acta Orthop"},{"key":"B14","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1097\/01241398-200101000-00003","article-title":"Titanium elastic nails for pediatric femur fractures: a multicenter study of early results with analysis of complications","volume":"21","author":"Flynn","year":"2001","journal-title":"J Pediatr Orthop."},{"key":"B15","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/s43465-020-00281-6","article-title":"Pediatric femoral shaft fracture: an age-based treatment algorithm","volume":"55","author":"Liau","year":"2020","journal-title":"Indian J Orthop."},{"key":"B16","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1111\/os.12514","article-title":"Elastic stable titanium flexible intramedullary nails versus plates in treating low grade comminuted femur shaft fractures in children","volume":"11","author":"Luo","year":"2019","journal-title":"Orthop Surg."},{"key":"B17","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1097\/BPO.0000000000001474","article-title":"Titanium elastic nails are a safe and effective treatment for length unstable pediatric femur fractures","volume":"40","author":"Siddiqui","year":"2020","journal-title":"J Pediatr Orthop."},{"key":"B18","doi-asserted-by":"publisher","first-page":"110","DOI":"10.23750\/abm.v90i1-S.8109","article-title":"Locking plate fixation in pediatric femur fracture: evaluation of the outcomes in our experience","volume":"90","author":"Vitiello","year":"2019","journal-title":"Acta Biomed"},{"key":"B19","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1097\/BPB.0000000000000342","article-title":"Comparison between external fixation and elastic stable intramedullary nailing for the treatment of femoral shaft fractures in children younger than 8 years of age","volume":"25","author":"Andreacchio","year":"2016","journal-title":"J Pediatr Orthop B."},{"key":"B20","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1097\/BPO.0b013e3181efb89d","article-title":"Decreased complications of pediatric femur fractures with a change in management","volume":"30","author":"Sink","year":"2010","journal-title":"J Pediatr Orthop"},{"key":"B21","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1097\/01.bpo.0000164872.44195.4f","article-title":"Complications of pediatric femur fractures treated with titanium elastic nails: a comparison of fracture types","volume":"25","author":"Sink","year":"2005","journal-title":"J Pediatr Orthop"},{"key":"B22","doi-asserted-by":"publisher","first-page":"e19","DOI":"10.2106\/JBJS.ST.N.00009","article-title":"Rigid intramedullary nailing of femoral shaft fractures in skeletally immature patients using a lateral trochanteric entry portal","volume":"4","author":"Kim","year":"2014","journal-title":"JBJS Essent Surg Tech."},{"key":"B23","first-page":"673","article-title":"Meta-analysis of external fixation and flexible intramedullary nails for femoral fractures in children","volume":"82","author":"Zhang","year":"2016","journal-title":"Acta Orthop Belg."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1007\/s00590-018-2201-3","article-title":"TEN versus external fixator in the management of pediatric diaphyseal femoral fractures: evaluation of the outcomes","volume":"28","author":"Rollo","year":"2018","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1097\/BPO.0b013e318287056d","article-title":"Comparison of submuscular and open plating of pediatric femur fractures: a retrospective review","volume":"33","author":"Abbott","year":"2013","journal-title":"J Pediatr Orthop."},{"key":"B26","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/s00402-001-0383-2","article-title":"The use of external fixators in the immobilization of pediatric fractures","volume":"122","author":"Norman","year":"2002","journal-title":"Arch Orthop Trauma Surg."},{"key":"B27","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1097\/01241398-199909000-00006","article-title":"External fixation of femoral shaft fractures in children: enhanced stability with the use of an auxiliary pin","volume":"19","author":"Sola","year":"1999","journal-title":"J Pediatr Orthop."},{"key":"B28","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1097\/01202412-199707000-00009","article-title":"External fixation of children's fractures: use of the orthofix dynamic axial fixator","volume":"6","author":"Hull","year":"1997","journal-title":"J Pediatr Orthop B."},{"key":"B29","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.injury.2019.03.044","article-title":"Pin tract infection prophylaxis and treatment","volume":"50","author":"Guerado","year":"2019","journal-title":"Injury."},{"key":"B30","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/01241398-199203000-00003","article-title":"External fixation of femur fractures in children","volume":"12","author":"Aronson","year":"1992","journal-title":"J Pediatr Orthop."},{"key":"B31","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1097\/BPO.0b013e3181b769ea","article-title":"Implant removal after submuscular plating for pediatric femur fractures","volume":"29","author":"Pate","year":"2009","journal-title":"J Pediatr Orthop."},{"key":"B32","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00402-008-0769-5","article-title":"Technical difficulties of removal of locking screw after locking compression plating","volume":"129","author":"Bae","year":"2009","journal-title":"Arch Orthop Trauma Surg."},{"key":"B33","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1097\/BOT.0000000000001652","article-title":"Overgrowth of the femur after internal fixation in children with femoral shaft fracture-a multicenter study","volume":"34","author":"Park","year":"2020","journal-title":"J Orthop Trauma."},{"key":"B34","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1302\/1863-2548.15.200252","article-title":"Leg-length discrepancy and associated risk factors after paediatric femur shaft fracture: a multicentre study","volume":"15","author":"Kim","year":"2021","journal-title":"J Child Orthop."}],"container-title":["Frontiers in Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2021.799487\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,10]],"date-time":"2022-02-10T05:26:31Z","timestamp":1644470791000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2021.799487\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,10]]},"references-count":34,"alternative-id":["10.3389\/fped.2021.799487"],"URL":"https:\/\/doi.org\/10.3389\/fped.2021.799487","relation":{},"ISSN":["2296-2360"],"issn-type":[{"value":"2296-2360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,10]]},"article-number":"799487"}}