{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T23:10:58Z","timestamp":1784848258179,"version":"3.55.0"},"reference-count":21,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,6,21]],"date-time":"2022-06-21T00:00:00Z","timestamp":1655769600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Pediatr."],"abstract":"<jats:p>Patients with continuous flow ventricular assist devices (CF-VAD's) in the systemic ventricle (left ventricle or single ventricle) often have no palpable pulses, unreliable pulse oximetry waveforms and non-pulsatile arterial waveforms despite hemodynamic stability. When circulatory decompensation occurs, standard indicators to begin cardiopulmonary resuscitation (CPR) which are used in other pediatric patients (i.e., significant bradycardia or loss of pulse) cannot be applied in the same fashion. In this population, there may already be pulselessness and development of bradycardia in and of itself would not trigger chest compressions. There are no universal guidelines to dictate when to consider chest compressions in this population. As such, there may be a delay in decision-making or in recognizing the need for chest compressions, even in patients hospitalized in intensive care units (ICU) and cared for by experienced staff who perform CPR regularly. We present four examples of pediatric cardiac ICU patients from a single center who underwent CPR between 2018 and 2019. Based on this case series, we propose a decision-making algorithm for chest compressions in pediatric patients with CF-VADs in the systemic ventricle.<\/jats:p>","DOI":"10.3389\/fped.2022.883320","type":"journal-article","created":{"date-parts":[[2022,6,21]],"date-time":"2022-06-21T06:00:37Z","timestamp":1655791237000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Chest Compressions in Pediatric Patients With Continuous-Flow Ventricular Assist Devices: Case Series and Proposed Algorithm"],"prefix":"10.3389","volume":"10","author":[{"given":"Ivie D.","family":"Esangbedo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priscilla","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,6,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1016\/j.athoracsur.2021.10.001","article-title":"Fifth annual pediatric interagency registry for mechanical circulatory support (Pedimacs) report","volume":"112","author":"Rossano","year":"2021","journal-title":"Ann Thorac Surg."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1819","DOI":"10.1016\/j.athoracsur.2020.09.003","article-title":"Fourth annual pediatric interagency registry for mechanical circulatory support (Pedimacs) report","volume":"110","author":"Morales","year":"2020","journal-title":"Ann Thorac Surg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1016\/j.athoracsur.2019.01.038","article-title":"Third annual pediatric interagency registry for mechanical circulatory support (Pedimacs) report: preimplant characteristics and outcomes","volume":"107","author":"Morales","year":"2019","journal-title":"Ann Thorac Surg."},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14194","article-title":"Children who stroke on VAD support: when is it safe to transplant and what are their outcomes?","author":"Thangappan","year":"2022","journal-title":"Artif Organs"},{"key":"B5","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1097\/MAT.0000000000001307","article-title":"Discharge and readmissions after ventricular assist device placement in the US pediatric hospitals: a collaboration in ACTION","volume":"67","author":"Bearl","year":"2021","journal-title":"ASAIO J Am Soc Artif Intern Organs 1992."},{"key":"B6","doi-asserted-by":"publisher","first-page":"329","DOI":"10.21037\/acs-2020-cfmcs-18","article-title":"Pediatric ventricular assist device registries: update and perspectives in the era of miniaturized continuous-flow pumps","volume":"10","author":"Lichtenstein","year":"2021","journal-title":"Ann Cardiothorac Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.resuscitation.2021.02.015","article-title":"European resuscitation council guidelines 2021: paediatric life support","volume":"161","author":"Van de Voorde","year":"2021","journal-title":"Resuscitation"},{"key":"B8","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1016\/j.cardfail.2014.10.007","article-title":"In-hospital cardiopulmonary arrests in patients with left ventricular assist devices","volume":"20","author":"Garg","year":"2014","journal-title":"J Card Fail."},{"key":"B9","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1177\/2048872615574107","article-title":"Advanced cardiovascular life support algorithm for the management of the hospitalized unresponsive patient on continuous flow left ventricular assist device support outside the intensive care unit","volume":"5","author":"Yuzefpolskaya","year":"2016","journal-title":"Eur Heart J Acute Cardiovasc Care."},{"key":"B10","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1097\/MAJ.0000000000000219","article-title":"Is a palpable pulse always restored during cardiopulmonary resuscitation in a patient with a left ventricular assist device?","volume":"347","author":"Haglund","year":"2014","journal-title":"Am J Med Sci."},{"key":"B11","doi-asserted-by":"publisher","first-page":"S469","DOI":"10.1542\/peds.2020-038505D","article-title":"Part 4: pediatric basic and advanced life support: 2020 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care","volume":"142","author":"Topjian","year":"2020","journal-title":"Circulation."},{"key":"B12","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.healun.2019.11.016","article-title":"Outcomes based on blood pressure in patients on continuous flow left ventricular assist device support: an interagency registry for mechanically assisted circulatory support analysis","volume":"39","author":"Cowger","year":"2020","journal-title":"J Heart Lung Transplant."},{"key":"B13","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1002\/ehf2.12456","article-title":"Accuracy of Doppler blood pressure measurement in continuous-flow left ventricular assist device patients","volume":"6","author":"Li","year":"2019","journal-title":"ESC Heart Fail."},{"key":"B14","doi-asserted-by":"publisher","first-page":"e1115","DOI":"10.1161\/CIR.0000000000000504","article-title":"Cardiopulmonary resuscitation in adults and children with mechanical circulatory support: a scientific statement from the American Heart Association","volume":"135","author":"Peberdy","year":"2017","journal-title":"Circulation."},{"key":"B15","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.resuscitation.2014.01.003","article-title":"Chest compressions may be safe in arresting patients with left ventricular assist devices (LVADs)","volume":"85","author":"Shinar","year":"2014","journal-title":"Resuscitation."},{"key":"B16","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1093\/icvts\/ivu117","article-title":"External cardiac compression during cardiopulmonary resuscitation of patients with left ventricular assist devices","volume":"19","author":"Mabvuure","year":"2014","journal-title":"Interact Cardiovasc Thorac Surg."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1412","DOI":"10.1213\/ANE.0000000000001851","article-title":"Perioperative care of the patient with the total artificial heart","volume":"124","author":"Yaung","year":"2017","journal-title":"Anesth Analg."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1438","DOI":"10.1016\/j.athoracsur.2013.06.120","article-title":"Successful use of the total artificial heart in the failing fontan circulation","volume":"97","author":"Rossano","year":"2014","journal-title":"Ann Thorac Surg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.hlc.2021.05.096","article-title":"Outcomes of cardiac arrest and cardiopulmonary resuscitation in patients with left ventricular assist device; an insight from a national inpatient sample","volume":"31","author":"Barssoum","year":"2022","journal-title":"Heart Lung Circ."},{"key":"B20","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.bja.2019.11.005","article-title":"Why chest compressions should start when systolic arterial blood pressure is below 50 mm Hg in the anaesthetised patient","volume":"124","author":"Harper","year":"2020","journal-title":"Br J Anaesth."},{"key":"B21","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1161\/CIR.0b013e31829d8654","article-title":"Cardiopulmonary resuscitation quality: improving cardiac resuscitation outcomes both inside and outside the hospital: a consensus statement from the American Heart Association","volume":"128","author":"Meaney","year":"2013","journal-title":"Circulation."}],"container-title":["Frontiers in Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2022.883320\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,21]],"date-time":"2022-06-21T06:00:39Z","timestamp":1655791239000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2022.883320\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,21]]},"references-count":21,"alternative-id":["10.3389\/fped.2022.883320"],"URL":"https:\/\/doi.org\/10.3389\/fped.2022.883320","relation":{},"ISSN":["2296-2360"],"issn-type":[{"value":"2296-2360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,21]]},"article-number":"883320"}}