{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T23:45:47Z","timestamp":1773186347804,"version":"3.50.1"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:00:00Z","timestamp":1749081600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Pediatr."],"abstract":"<jats:p>Central venous catheters (CVCs) are essential in neonatal care units to ensure prolonged venous access. Despite experienced CVC placement, managing fragile and small newborn vessels involves the risk of traumatic and iatrogenic complications. The most common include phlebitis, thrombosis, sepsis, and catheter displacement. Rarely, catheter displacement may lead to fluid accumulation around serous membranes and adjacent organs, which, if not identified early, can even result in neonatal death. We report two cases: one of neonatal hydrothorax with subsequent lung cystic formation after a parenteral nutrition leakage caused by the displacement of an Epicutaneo-Caval Catheter in the basilic vein of the left arm; the second involves a peritoneal collection of parenteral nutrition from the umbilical venous catheter.<\/jats:p>","DOI":"10.3389\/fped.2025.1602098","type":"journal-article","created":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T05:29:20Z","timestamp":1749101360000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Case Report: Uncommon complications of central catheters in newborns: two cases of parenteral nutrition extravasation"],"prefix":"10.3389","volume":"13","author":[{"given":"Carolina","family":"Coramusi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica F.","family":"Toro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ram\u00f3n G.","family":"Pab\u00f3n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Barreto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Di Nardo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pasquale","family":"Parisi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudia C. M.","family":"Mar\u00edn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2025,6,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1177\/0148607116644714","article-title":"Percutaneously inserted central catheter-related pleural effusion in a level III neonatal intensive care unit: a 5-year review (2008\u20132012)","volume":"41","author":"Bashir","year":"2017","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"B2","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1038\/s41372-019-0579-3","article-title":"Umbilical catheter-associated complications in a level IV neonatal intensive care unit","volume":"40","author":"Levit","year":"2020","journal-title":"J Perinatol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.clp.2007.11.007","article-title":"Complications of vascular catheters in the neonatal intensive care unit","volume":"35","author":"Ramasethu","year":"2008","journal-title":"Clin Perinatol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1177\/1129729820928182","article-title":"Effect of implementing an epicutaneo-caval catheter team in neonatal intensive care unit","volume":"22","author":"Bayoumi","year":"2021","journal-title":"J Vasc Access"},{"key":"B5","doi-asserted-by":"publisher","first-page":"11297298241239699","DOI":"10.1177\/11297298241239699","article-title":"The SIECC protocol: a novel insertion bundle to minimize the complications related to epicutaneo-cava catheters in neonates","author":"D'Andrea","year":"2024","journal-title":"J Vasc Access"},{"key":"B6","doi-asserted-by":"publisher","first-page":"890","DOI":"10.1177\/0148607115574000","article-title":"Peripherally inserted central catheters complicated by vascular erosion in neonates","volume":"40","author":"Blackwood","year":"2016","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"B7","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1177\/1129729819891546","article-title":"Epicutaneo-caval catheters in neonates: new insights and new suggestions from the recent literature","volume":"21","author":"Barone","year":"2020","journal-title":"J Vasc Access"},{"key":"B8","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.anpedi.2015.10.011","article-title":"Complicaciones mec\u00e1nicas asociadas a la localizaci\u00f3n de la punta de cat\u00e9teres centrales en una unidad neonatal [Catheter tip position and risk of mechanical complications in a neonatal unit]","volume":"85","author":"Lloreda-Garc\u00eda","year":"2016","journal-title":"An Pediatr (Barc)"},{"key":"B9","doi-asserted-by":"publisher","first-page":"209","DOI":"10.2147\/IMCRJ.S405684","article-title":"Neonatal COVID-19 with atypical lung cystic lesions mimicking congenital pulmonary airway malformation - a diagnostic dilemma","volume":"16","author":"Ghazwani","year":"2023","journal-title":"Int Med Case Rep J"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.3390\/healthcare9081015","article-title":"Lung ultrasound in pediatrics and neonatology: an update","volume":"9","author":"Ammirabile","year":"2021","journal-title":"Healthcare (Basel)"},{"key":"B11","doi-asserted-by":"publisher","first-page":"77","DOI":"10.18270\/rce.v11i12.1689","article-title":"Secondary hydropneumothorax due to extravasations for parenteral nutrition in the pleural spaces: case report","volume":"12","author":"Agudelo","year":"2016","journal-title":"Rev Colomb Enferm"},{"key":"B12","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1038\/s41572-023-00470-1","article-title":"Congenital lung malformations","volume":"9","author":"Pederiva","year":"2023","journal-title":"Nat Rev Dis Primers"},{"key":"B13","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1016\/j.clp.2022.08.003","article-title":"Management of congenital lung malformations","volume":"49","author":"Hegde","year":"2022","journal-title":"Clin Perinatol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1055\/s-0031-1295649","article-title":"The use of targeted neonatal echocardiography to confirm placement of peripherally inserted central catheters in neonates","volume":"29","author":"Jain","year":"2012","journal-title":"Am J Perinatol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.1007\/s00431-017-3032-7","article-title":"Congenital pulmonary airway malformations: state-of-the-art review for pediatrician\u2019s use","volume":"176","author":"Leblanc","year":"2017","journal-title":"Eur J Pediatr"},{"key":"B16","doi-asserted-by":"publisher","first-page":"2505","DOI":"10.1038\/s41372-021-01147-x","article-title":"Adverse events associated with umbilical catheters: a systematic review and meta-analysis","volume":"41","author":"Gibson","year":"2021","journal-title":"J Perinatol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1055\/a-2295-5110","article-title":"Umbilical catheter extravasation mimicking necrotizing enterocolitis in a preterm neonate: a diagnostic challenge","volume":"228","author":"Arma\u011fan","year":"2024","journal-title":"Z Geburtshilfe Neonatol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1007\/s10354-022-00952-z","article-title":"Umbilical venous catheter- and peripherally inserted central catheter-associated complications in preterm infants with birth weight <1250\u2005g: results from a survey in Austria and Germany","volume":"173","author":"Hess","year":"2023","journal-title":"Wien Med Wochenschr"},{"key":"B19","doi-asserted-by":"publisher","first-page":"2850","DOI":"10.3390\/diagnostics13172850","article-title":"The role of ultrasound in epicutaneo-caval catheter insertion in neonates: systematic review, meta-analysis and future perspectives","volume":"13","author":"D'Andrea","year":"2023","journal-title":"Diagnostics (Basel)"},{"key":"B20","doi-asserted-by":"publisher","first-page":"e1183","DOI":"10.1055\/s-0043-1760744","article-title":"Real-time ultrasound tip location reduces malposition and radiation exposure during epicutaneo-caval catheter placement in neonates","volume":"41","author":"D'Andrea","year":"2024","journal-title":"Am J Perinatol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1007\/s00431-023-05378-2","article-title":"Point-of-care ultrasound for vascular access in neonates and children","volume":"183","author":"Pittiruti","year":"2024","journal-title":"Eur J Pediatr"},{"key":"B22","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1177\/11297298211054637","article-title":"Modified Seldinger technique for neonatal epicutaneo-caval catheter insertion: a non-randomised retrospective study","volume":"24","author":"Gibb","year":"2023","journal-title":"J Vasc Access"},{"key":"B23","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1111\/apa.12245","article-title":"Echocardiography allows more accurate placement of peripherally inserted central catheters in low birthweight infants","volume":"102","author":"Tauzin","year":"2013","journal-title":"Acta Paediatr"},{"key":"B24","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1038\/sj.jp.7210851","article-title":"Echocardiographic evaluation of umbilical venous catheter placement","volume":"23","author":"Ades","year":"2003","journal-title":"J Perinatol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1022796","DOI":"10.3389\/fped.2022.1022796","article-title":"Ultrasound to guided epicutaneo-caval catheter insertion in newborn infants","volume":"10","author":"Ren","year":"2022","journal-title":"Front Pediatr"},{"key":"B26","doi-asserted-by":"publisher","first-page":"395","DOI":"10.3390\/children11040395","article-title":"Ultrasound-guided centrally inserted central catheter (CICC) placement in newborns: a safe clinical training program in a neonatal intensive care unit","volume":"11","author":"Zini","year":"2024","journal-title":"Children (Basel)"},{"key":"B27","doi-asserted-by":"publisher","first-page":"3385","DOI":"10.1007\/s00431-023-04984-4","article-title":"The neonatal DAV-expert algorithm: a GAVeCeLT\/GAVePed consensus for the choice of the most appropriate venous access in newborns","volume":"182","author":"Barone","year":"2023","journal-title":"Eur J Pediatr"},{"key":"B28","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3390\/children11010026","article-title":"Central lines and their complications in neonates: a case report and literature review","volume":"11","author":"Perme","year":"2023","journal-title":"Children (Basel)"}],"container-title":["Frontiers in Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2025.1602098\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T05:29:20Z","timestamp":1749101360000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2025.1602098\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,5]]},"references-count":28,"alternative-id":["10.3389\/fped.2025.1602098"],"URL":"https:\/\/doi.org\/10.3389\/fped.2025.1602098","relation":{},"ISSN":["2296-2360"],"issn-type":[{"value":"2296-2360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,5]]},"article-number":"1602098"}}