{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:23:30Z","timestamp":1787027010356,"version":"build-2736575974"},"reference-count":18,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Pediatr."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Transanastomotic feeding tubes (TATs) are placed to allow early feeding following esophageal atresia\/tracheoesophageal fistula (EA\/TEF) repair. However, recently these tubes were linked to increased rates of postoperative complications. The aim of this study is to report our single center experience with and without the use of TATs in patients with EA\/TEF.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and methods<\/jats:title>\n                    <jats:p>The data of 152 patients operated for EA and distal TEF in our hospital from January 2014 to September 2024 were retrospectively reviewed. Patients were divided into two groups; those who did not have TATs (NOTAT group) and those who have their TATs left in-place until deliberately removed according to postoperative care protocol (TAT group). Both groups were compared regarding baseline characteristics, operative findings, postoperative care and postoperative complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The TAT group included 130 patients while the NOTAT group included 22 patients. There were no statistically significant differences between the two groups in terms of birth weight, gestational age, the rate of prematurity or the associated anomalies. The time of commencing enteral feeding was significantly earlier in the TAT group (median POD #3 vs. POD# 13 in the NOTAT group) and the duration of TPN was significantly shorter (mean of 6.6 vs. 16.2 days in the NOTAT group). There were no statistically significant differences between the two groups regarding the rate of postoperative anastomotic leaks (23.0% in the TAT group vs. 18.1% in the NOTAT group;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.700) or strictures.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Trans anastomotic feeding tubes (TATs) offer benefits in terms of early enteral feeding, and shorter duration of parenteral nutrition for patients with EA\/TEF undergoing surgical repair. At the same time, they don't seem to add a risk of anastomotic leaks or strictures. Large prospective randomized studies are required to further evaluate any possible relationships between TATs and the postoperative complications following repair of EA\/TEF.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fped.2025.1685089","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T06:29:51Z","timestamp":1763015391000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Surgical repair of esophageal atresia: do trans-anastomotic feeding tubes have an impact on the outcome?"],"prefix":"10.3389","volume":"13","author":[{"given":"Mohamed Yousef","family":"Batikhe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mostafa","family":"Redwan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Gafar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Ramadan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1089\/lap.2020.0099","article-title":"Early management of esophageal leak in esophageal atresia: changing paradigms","volume":"30","author":"Godoy","year":"2020","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"B2","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1016\/j.jpedsurg.2017.05.024","article-title":"Challenging surgical dogma in the management of proximal esophageal atresia with distal tracheoesophageal fistula: outcomes from the Midwest pediatric surgery consortium","volume":"53","author":"Lal","year":"2018","journal-title":"J Pediatr Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.jpedsurg.2021.09.014","article-title":"Effect of transanastomotic feeding tubes on anastomotic strictures in patients with esophageal atresia and tracheoesophageal fistula: the Quebec experience","volume":"57","author":"LaRusso","year":"2022","journal-title":"J Pediatr Surg"},{"key":"B4","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1002\/bdra.23493","article-title":"Prevalence, characteristics, and survival of children with esophageal atresia: a 32-year population-based study including 1,417,724 consecutive newborns","volume":"106","author":"Cassina","year":"2016","journal-title":"Birth Defects Res A Clin Mol Teratol"},{"key":"B5","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/S0140-6736(21)00767-4","article-title":"Mortality from gastrointestinal congenital anomalies at 264 hospitals in 74 low-income, middle-income, and high-income countries: a multicentre, international, prospective cohort study","volume":"398","author":"Wright","year":"2021","journal-title":"Lancet"},{"key":"B6","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.surg.2014.03.016","article-title":"Morbidity and mortality in patients with esophageal atresia","volume":"156","author":"Sulkowski","year":"2014","journal-title":"Surgery"},{"key":"B7","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.jpedsurg.2023.09.026","article-title":"A minimally interventional approach to oesophageal atresia repair with early enteral feeding is safe, optimises neonatal outcomes, and reduces resource use","volume":"59","author":"Hall","year":"2024","journal-title":"J Pediatr Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1001\/archsurg.1989.01410100090015","article-title":"Primary repair without routine gastrostomy is the treatment of choice for neonates with esophageal atresia and tracheoesophageal fistula","volume":"124","author":"Shaul","year":"1989","journal-title":"Arch Surg"},{"key":"B9","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1016\/0022-3468(92)90469-N","article-title":"Insertion of a soft silastic nasogastric tube at operation for esophageal atresia: a new technical method","volume":"27","author":"Sweed","year":"1992","journal-title":"J Pediatr Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/S0022-3468(96)90318-8","article-title":"Transanastomotic feeding tubes in repair of esophageal atresia","volume":"31","author":"Moriarty","year":"1996","journal-title":"J Pediatr Surg"},{"key":"B11","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/j.jpedsurg.2009.01.027","article-title":"Use of transanastomotic feeding tubes during esophageal atresia repair","volume":"44","author":"Alabbad","year":"2009","journal-title":"J Pediatr Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/S0022-3468(84)80025-1","article-title":"Esophageal anastomosis-an experimental model to study the anastomotic lumen and the influence of a transanastomotic tube","volume":"19","author":"Carachi","year":"1984","journal-title":"J Pediatr Surg"},{"key":"B13","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.ijporl.2011.10.012","article-title":"Surgical management with or without a nasogastric tube in esophageal repairs","volume":"76","author":"Yurt\u00e7u","year":"2012","journal-title":"Int J Pediatr Otorhinolaryngol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1007\/s12519-017-0047-0","article-title":"Is routine use of transanastomotic tube justified in the repair of esophageal atresia?","volume":"13","author":"Narayanan","year":"2017","journal-title":"World J Pediatr"},{"key":"B15","doi-asserted-by":"publisher","first-page":"728","DOI":"10.4103\/jiaps.jiaps_61_22","article-title":"Technical innovations to reduce complication rates in esophageal atresia with particular reference to long-term outcomes: a single surgeon\u2019s experience of 22 years","volume":"27","author":"Morsi","year":"2022","journal-title":"J Indian Assoc Pediatr Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1186\/s12887-018-1359-5","article-title":"What is the impact of the use of transanastomotic feeding tube on patients with esophageal atresia: a systematic review and meta-analysis","volume":"18","author":"Wang","year":"2018","journal-title":"BMC Pediatr"},{"key":"B17","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.jpedsurg.2017.10.026","article-title":"A large single-institution review of tracheoesophageal fistulae with evaluation of the use of transanastomotic feeding tubes","volume":"53","author":"Fusco","year":"2018","journal-title":"J Pediatr Surg"},{"key":"B18","year":""}],"container-title":["Frontiers in Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2025.1685089\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T06:29:52Z","timestamp":1763015392000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2025.1685089\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":18,"alternative-id":["10.3389\/fped.2025.1685089"],"URL":"https:\/\/doi.org\/10.3389\/fped.2025.1685089","relation":{},"ISSN":["2296-2360"],"issn-type":[{"value":"2296-2360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,13]]},"article-number":"1685089"}}