{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:52:28Z","timestamp":1786121548510,"version":"build-2736575974"},"reference-count":19,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Pediatr."],"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To compare the measurement reliability, procedural efficiency, and infant stress responses between device-assisted and manual restraint approaches in Graf hip ultrasonography for developmental dysplasia of the hip (DDH) screening.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      In this retrospective cohort study, 238 infants (aged 0\u20136 months) underwent consecutive hip ultrasound examinations using both a Graf stabilization device and manual restraint during the same visit. Each examination included triple measurements of\n                      <jats:italic>\u03b1<\/jats:italic>\n                      and\n                      <jats:italic>\u03b2<\/jats:italic>\n                      angles by a single experienced sonographer. Primary outcomes included angle measurements and Graf classification. Examination time and infant crying incidence were also recorded. Intra-observer reliability for repeated measurements within each technique and inter-technique agreement between the two methods were evaluated separately using intraclass correlation coefficients (ICC) and Cohen's kappa.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No significant differences were observed in\n                      <jats:italic>\u03b1<\/jats:italic>\n                      angle (67.00\u00b0 vs. 67.50\u00b0,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.313),\n                      <jats:italic>\u03b2<\/jats:italic>\n                      angle (71.00\u00b0 vs. 69.00\u00b0,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.179), or Graf classification distribution (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.832) between device-assisted and manual methods. However, the device-assisted approach showed significantly shorter examination time (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001) and a 13.5-fold reduction in crying incidence (0.84% vs. 11.34%,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001). Intra-observer reliability was excellent with device assistance (\n                      <jats:italic>\u03b1<\/jats:italic>\n                      angle: ICC\u2009=\u20090.95,\n                      <jats:italic>\u03b2<\/jats:italic>\n                      angle: ICC\u2009=\u20090.90) but poor with manual restraint (\n                      <jats:italic>\u03b1<\/jats:italic>\n                      angle: ICC\u2009=\u20090.49,\n                      <jats:italic>\u03b2<\/jats:italic>\n                      angle: ICC\u2009=\u20090.23). Inter-technique agreement was moderate for\n                      <jats:italic>\u03b1<\/jats:italic>\n                      angle (ICC\u2009=\u20090.71) and substantial for Graf classification (\n                      <jats:italic>\u03ba<\/jats:italic>\n                      \u2009=\u20090.66), but poor with\n                      <jats:italic>\u03b2<\/jats:italic>\n                      angle (ICC\u2009=\u20090.36).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The use of a stabilization device in Graf hip ultrasonography significantly improves measurement reliability and may enhance examination efficiency and infant comfort without altering diagnostic outcomes, supporting its integration into high-volume DDH screening programs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fped.2026.1902579","type":"journal-article","created":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T05:29:37Z","timestamp":1786080577000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A stabilization device significantly improves measurement reliability and efficiency of Graf ultrasonography for developmental dysplasia of the hip: a retrospective cohort study"],"prefix":"10.3389","volume":"14","author":[{"given":"Yehui","family":"Lan","sequence":"first","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liyu","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miao","family":"Jin","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Du","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianfei","family":"Yan","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Quanzhou","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenying","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanhua","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihui","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University","place":["Lishui, Zhejiang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1302\/1863-2548.15.200084","article-title":"Paediatric hip ultrasound: uncertainties in examination and choice of treatment","volume":"15","author":"Bucher","year":"2021","journal-title":"J Child Orthop"},{"key":"B2","doi-asserted-by":"publisher","first-page":"235","DOI":"10.2106\/JBJS.20.00562","article-title":"Secondary surgery and residual dysplasia following late closed or open reduction of developmental dysplasia of the hip","volume":"103","author":"Morris","year":"2021","journal-title":"J Bone Joint Surg Am"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1521","DOI":"10.1007\/s00247-022-05334-6","article-title":"Use of ultrasonography to evaluate early outcomes of reduction in developmental dysplasia of the hip","volume":"52","author":"Luan","year":"2022","journal-title":"Pediatr Radiol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"202","DOI":"10.5435\/JAAOS-D-15-00006","article-title":"Detection and nonoperative management of pediatric developmental dysplasia of the hip in infants up to six months of age","volume":"23","author":"Mulpuri","year":"2015","journal-title":"J Am Acad Orthop Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1002696","DOI":"10.3389\/fped.2022.1002696","article-title":"Four decades of the Graf method in screening for developmental dysplasia of the hip (part I): rightly the gold standard or of dubious benefit?","volume":"10","author":"Ossendorff","year":"2022","journal-title":"Front Pediatr"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.21037\/tp-21-137","article-title":"The feasibility of ultrasound Graf method in screening infants and young children with congenital hip dysplasia and follow-up of treatment effect","volume":"10","author":"Liu","year":"2021","journal-title":"Transl Pediatr"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1007\/s00247-016-3552-8","article-title":"An index for diagnosing infant hip dysplasia using 3-D ultrasound: the acetabular contact angle","volume":"46","author":"Mabee","year":"2016","journal-title":"Pediatr Radiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1051\/sicotj\/2025016","article-title":"Impact of probe tilt on Graf ultrasonography accuracy for neonatal hip dysplasia screening","volume":"11","author":"Sioutis","year":"2025","journal-title":"SICOT J"},{"key":"B9","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/BF00450934","article-title":"The diagnosis of congenital hip-joint dislocation by the ultrasonic combound treatment","volume":"97","author":"Graf","year":"1980","journal-title":"Arch Orthop Trauma Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s12887-019-1392-z","article-title":"Ultrasound of the infant hip: manual fixation is equivalent to Graf\u2019s technique regarding image quality-a randomized trial","volume":"19","author":"Voitl","year":"2019","journal-title":"BMC Pediatr"},{"key":"B11","doi-asserted-by":"publisher","first-page":"97","DOI":"10.3390\/children11010097","article-title":"Screening of developmental dysplasia of the hip in Europe: a systematic review","volume":"11","author":"Krysta","year":"2024","journal-title":"Children"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1007\/s00431-026-06849-y","article-title":"Learning curves and training thresholds for paediatricians performing neonatal hip ultrasound using the Graf method in a universal screening program","volume":"185","author":"Aguilar","year":"2026","journal-title":"Eur J Pediatr"},{"key":"B13","doi-asserted-by":"publisher","first-page":"299","DOI":"10.11152\/mu.2013.2066.154.rg2","article-title":"Hip sonography update. Quality-management, catastrophes - tips and tricks","volume":"15","author":"Graf","year":"2013","journal-title":"Med Ultrason"},{"key":"B14","doi-asserted-by":"publisher","first-page":"e26291","DOI":"10.1097\/MD.0000000000026291","article-title":"Interobserver agreement and clinical disparity between the Graf method and femoral head coverage measurement in developmental dysplasia of the hip screening: a prospective observational study of 198 newborns","volume":"100","author":"Chang","year":"2021","journal-title":"Medicine"},{"key":"B15","doi-asserted-by":"publisher","first-page":"990806","DOI":"10.3389\/fped.2022.990806","article-title":"Four decades of developmental dysplastic hip screening according to Graf: what have we learned?","volume":"10","author":"Walter","year":"2022","journal-title":"Front Pediatr"},{"key":"B16","doi-asserted-by":"publisher","first-page":"e305","DOI":"10.1097\/BPO.0000000000001179","article-title":"A systematic review and meta-analysis on the reproducibility of ultrasound-based metrics for assessing developmental dysplasia of the hip","volume":"38","author":"Quader","year":"2018","journal-title":"J Pediatr Orthop"},{"key":"B17","doi-asserted-by":"publisher","first-page":"e440","DOI":"10.1097\/BPO.0000000000001421","article-title":"Coronal flexion versus coronal neutral sonographic views in infantile DDH: an important source of variability","volume":"40","author":"Meza","year":"2020","journal-title":"J Pediatr Orthop"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.1302\/0301-620X.105B10.BJJ-2023-0143.R1","article-title":"Paediatric hip ultrasound","author":"Donnan","year":"2023","journal-title":"Bone Joint J"},{"key":"B19","doi-asserted-by":"publisher","first-page":"e0300753","DOI":"10.1371\/journal.pone.0300753","article-title":"Comparison of quality and interpretation of newborn ultrasound screening examinations for developmental dysplasia of the hip by basically trained nurses and junior physicians with no previous ultrasound experience","volume":"19","author":"Ulziibat","year":"2024","journal-title":"PLoS One"}],"container-title":["Frontiers in Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2026.1902579\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T05:29:38Z","timestamp":1786080578000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2026.1902579\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,7]]},"references-count":19,"alternative-id":["10.3389\/fped.2026.1902579"],"URL":"https:\/\/doi.org\/10.3389\/fped.2026.1902579","relation":{},"ISSN":["2296-2360"],"issn-type":[{"value":"2296-2360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,7]]},"article-number":"1902579"}}