{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T06:24:19Z","timestamp":1787293459300,"version":"build-2736575974"},"reference-count":10,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T00:00:00Z","timestamp":1787270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Pediatr."],"abstract":"<jats:p>We present data of a preterm infant at 28 4\/7 weeks gestation with inadequate response to non-invasive ventilation after birth who was intubated five minutes after delivery. During non-invasive stabilization, we noted a discrepancy between the displayed tidal volumes on the respiratory function monitor (RFM) and the real-time electrical impedance tomography (EIT) measurements. While expiratory tidal volumes on the RFM were in the recommended target of 4\u20136 mL\/kg, EIT showed only minimal tidal volumes (corresponding to approximately 1\u20133 mL\/kg), which was more consistent with the clinical impression of the neonate. After intubation, tidal volumes shown on RFM and EIT were similar, suggesting that RFM may be unreliable during non-invasive ventilation, possibly due to the large compliance of the nasopharyngeal space. EIT may be a helpful additional clinical tool in selective cases in the delivery room.<\/jats:p>","DOI":"10.3389\/fped.2026.1918821","type":"journal-article","created":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T05:37:33Z","timestamp":1787290653000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Discrepancy in applied tidal volumes between t-piece and lung level during delivery room stabilization \u2013 a case report"],"prefix":"10.3389","volume":"14","author":[{"given":"Alexia","family":"Zanghi","sequence":"first","affiliation":[{"name":"Division Neonatology Department of Pediatrics, Dr. von Hauner Children\u2019s Hospital, LMU Medizin, LMU University Hospital, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen","place":["Munich, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Wall","sequence":"additional","affiliation":[{"name":"Division Neonatology Department of Pediatrics, Dr. von Hauner Children\u2019s Hospital, LMU Medizin, LMU University Hospital, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen","place":["Munich, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David G.","family":"Tingay","sequence":"additional","affiliation":[{"name":"Neonatal Research, Murdoch Children\u2019s Research Institute","place":["Melbourne, VIC, Australia"]},{"name":"Department of Paediatrics, University of Melbourne","place":["Melbourne, VIC, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas W.","family":"Flemmer","sequence":"additional","affiliation":[{"name":"Division Neonatology Department of Pediatrics, Dr. von Hauner Children\u2019s Hospital, LMU Medizin, LMU University Hospital, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen","place":["Munich, Germany"]},{"name":"Member of the German Center for Lung Research (DZL), Comprehensive Pneumology Center Munich","place":["Munich, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent D.","family":"Gaertner","sequence":"additional","affiliation":[{"name":"Division Neonatology Department of Pediatrics, Dr. von Hauner Children\u2019s Hospital, LMU Medizin, LMU University Hospital, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen","place":["Munich, Germany"]},{"name":"Member of the German Center for Lung Research (DZL), Comprehensive Pneumology Center Munich","place":["Munich, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"110766","DOI":"10.1016\/j.resuscitation.2025.110766","article-title":"European Resuscitation Council Guidelines 2025 newborn resuscitation and support of transition of infants at birth","volume":"215","author":"Hogeveen","year":"2025","journal-title":"Resuscitation"},{"key":"B2","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1164\/ajrccm.154.4.8887585","article-title":"The accuracy of pneumotachograph measurements during mechanical ventilation","volume":"154","author":"Kreit","year":"1996","journal-title":"Am J Respir Crit Care Med"},{"key":"B3","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1186\/s12887-022-03600-y","article-title":"Tidal volumes during delivery room stabilization of (near) term infants","volume":"22","author":"Thomann","year":"2022","journal-title":"BMC Pediatr"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1513\/AnnalsATS.202505-478FR","article-title":"Noninvasive imaging of the neonatal lung using electrical impedance tomography: a narrative review","volume":"22","author":"Gaertner","year":"2025","journal-title":"Ann Am Thorac Soc"},{"key":"B5","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1093\/ajrccm\/aamag008","article-title":"The first breaths after birth\u2014early lung function in healthy term infants","volume":"212","author":"Gaertner","year":"2026","journal-title":"Am J Respir Crit Care Med"},{"key":"B6","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","article-title":"Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group","volume":"72","author":"Frerichs","year":"2017","journal-title":"Thorax"},{"key":"B7","doi-asserted-by":"publisher","first-page":"979763","DOI":"10.3389\/fped.2022.979763","article-title":"Case report: intrapulmonary tidal volumes in a preterm infant with chest wall rigidity","volume":"10","author":"Gaertner","year":"2022","journal-title":"Front Pediatr"},{"key":"B8","doi-asserted-by":"publisher","first-page":"101288","DOI":"10.1016\/j.resplu.2026.101288","article-title":"Corrective steps during neonatal mask ventilation \u2013 a narrative review of the evidence behind the MR SOPA acronym","volume":"29","author":"Gaertner","year":"2026","journal-title":"Resus Plus"},{"key":"B9","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1097\/01.PCC.0000059334.04333.1B","article-title":"Correction factors for oxygen and flow-rate effects on neonatal Fleisch and Lilly pneumotachometers","volume":"4","author":"Snepvangers","year":"2003","journal-title":"Pediatr Crit Care Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1111\/aas.12143","article-title":"Electrical impedance tomography for verification of correct endotracheal tube placement in paediatric patients: a feasibility study","volume":"57","author":"Steinmann","year":"2013","journal-title":"Acta Anaesthesiol Scand"}],"container-title":["Frontiers in Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2026.1918821\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T05:37:34Z","timestamp":1787290654000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fped.2026.1918821\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,21]]},"references-count":10,"alternative-id":["10.3389\/fped.2026.1918821"],"URL":"https:\/\/doi.org\/10.3389\/fped.2026.1918821","relation":{},"ISSN":["2296-2360"],"issn-type":[{"value":"2296-2360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,21]]},"article-number":"1918821"}}