{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T17:00:18Z","timestamp":1790960418883,"version":"4.1.0"},"reference-count":95,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2020,10,16]],"date-time":"2020-10-16T00:00:00Z","timestamp":1602806400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100008530","name":"European Regional Development Fund","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Physiol."],"DOI":"10.3389\/fphys.2020.568886","type":"journal-article","created":{"date-parts":[[2020,10,16]],"date-time":"2020-10-16T02:31:20Z","timestamp":1602815480000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":52,"title":["Hearables: New Perspectives and Pitfalls of In-Ear Devices for Physiological Monitoring. A Scoping Review"],"prefix":"10.3389","volume":"11","author":[{"given":"Michela","family":"Mas\u00e8","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Micarelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Strapazzon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2020,10,16]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1249\/MSS.0b013e31802fa199","article-title":"American College of sports medicine position stand. Exertional heat illness during training and competition","volume":"39","author":"Armstrong","year":"2007","journal-title":"Med. Sci. Sports Exerc."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.3357\/ASEM.3102.2011","article-title":"Validity of field expedient devices to assess core temperature during exercise in the cold","volume":"82","author":"Bagley","year":"2011","journal-title":"Aviat. Space Environ. Med."},{"key":"B3","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1111\/ijn.12097","article-title":"Comparison of three different thermometers in evaluating the body temperature of healthy young adult individuals","volume":"19","author":"Basak","year":"2013","journal-title":"Int. J. Nurs. Pract."},{"key":"B4","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1088\/0967-3334\/32\/4\/001","article-title":"The effect of lower body cooling on the changes in three core temperature indices","volume":"32","author":"Basset","year":"2011","journal-title":"Physiol. Meas."},{"key":"B5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41746-020-0226-6","article-title":"Investigating sources of inaccuracy in wearable optical heart rate sensors","volume":"3","author":"Bent","year":"2020","journal-title":"NPJ Digital Med."},{"key":"B6","first-page":"111","article-title":"\u201cCranial measurements of internal temperature in man,\u201d","volume-title":"Temperature - Its Measurement and Control in Science and Industry","author":"Benzinger","year":"1963"},{"key":"B7","first-page":"649","article-title":"\u201cExternal and middle ear.\u201d","volume-title":"Gray's Anatomy. The Anatomical Basis of Clinical Practice","author":"Berkovitz","year":"2005"},{"key":"B8","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.wem.2009.12.003","article-title":"Detection and management of hypothermia at a large outdoor endurance event in the United kingdom","volume":"21","author":"Bhangu","year":"2010","journal-title":"Wilderness Environ. Med."},{"key":"B9","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1249\/MSS.0000000000001471","article-title":"Validity of wearable activity monitors during cycling and resistance exercise","volume":"50","author":"Boudreaux","year":"2018","journal-title":"Med. Sci. Sports Exerc."},{"key":"B10","doi-asserted-by":"publisher","first-page":"94","DOI":"10.4037\/ccn2009132","article-title":"Noninvasive measurement of body temperature in critically ill patients","volume":"29","author":"Bridges","year":"2009","journal-title":"Crit. Care Nurse"},{"key":"B11","doi-asserted-by":"publisher","first-page":"73","DOI":"10.3389\/fphys.2014.00073","article-title":"Monitoring training status with HR measures: do all roads lead to Rome?","volume":"5","author":"Buchheit","year":"2014","journal-title":"Front. Physiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1088\/0967-3334\/35\/2\/111","article-title":"The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation","volume":"35","author":"Budidha","year":"2014","journal-title":"Physiol. Meas."},{"key":"B13","doi-asserted-by":"publisher","first-page":"7954","DOI":"10.1109\/EMBC.2015.7320237","article-title":"Investigation of photoplethysmography and arterial blood oxygen saturation from the ear-canal and the finger under conditions of artificially induced hypothermia","volume":"2015","author":"Budidha","year":"2015","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"B14","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10877-017-9975-4","article-title":"In vivo investigation of ear canal pulse oximetry during hypothermia","volume":"32","author":"Budidha","year":"2018","journal-title":"J. Clin. Monit. Comput."},{"key":"B15","first-page":"374","article-title":"Evaluation of earbud and wristwatch heart rate monitors during aerobic and resistance training","volume":"12","author":"Bunn","year":"2019","journal-title":"Int. J. Exerc. Sci."},{"key":"B16","doi-asserted-by":"publisher","first-page":"5780","DOI":"10.1109\/IEMBS.2010.5627835","article-title":"New ear sensor for mobile, continuous and long term pulse oximetry","volume":"2010","author":"Buschmann","year":"2010","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"B17","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1097\/01.CSMR.0000306292.64954.da","article-title":"Exertional heat stroke in competitive athletes","volume":"4","author":"Casa","year":"2005","journal-title":"Curr. Sports Med. Rep."},{"key":"B18","doi-asserted-by":"publisher","first-page":"3315","DOI":"10.3390\/s18103315","article-title":"Measurement of core body temperature using graphene-inked infrared thermopile sensor","volume":"18","author":"Chaglla","year":"2018","journal-title":"Sensors"},{"key":"B19","doi-asserted-by":"publisher","first-page":"i40","DOI":"10.1136\/bjsports-2013-092837","article-title":"The individual response to training and competition at altitude","volume":"47","author":"Chapman","year":"2013","journal-title":"Br. J. Sports Med."},{"key":"B20","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s13534-019-00102-2","article-title":"Thermometry and interpretation of body temperature","volume":"9","author":"Chen","year":"2019","journal-title":"Biomed. Eng. Lett"},{"key":"B21","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1111\/j.1365-2044.1991.tb11492.x","article-title":"Pulse oximeter probes. A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion","volume":"46","author":"Clayton","year":"1991","journal-title":"Anaesthesia"},{"key":"B22","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1089\/ham.2019.0092","article-title":"Effects of normobaric hypoxia on oxygen saturation variability","volume":"21","author":"Costello","year":"2020","journal-title":"High Alt. Med. Biol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1756","DOI":"10.1056\/NEJM199412293312607","article-title":"Accidental hypothermia","volume":"331","author":"Danzl","year":"1994","journal-title":"N. Engl. J. Med"},{"key":"B24","unstructured":"DaviesH. J. WilliamsI. PetersN. S. MandicD. P. In-Ear Measurement of Blood Oxygen Saturation: An Ambulatory Tool Needed To Detect The Delayed Life-Threatening Hypoxaemia in COVID-19. arXiv:2006.04231 [eess]2020"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1109\/TBCAS.2019.2930312","article-title":"Heart rate extraction in a headphone using infrared thermometry","volume":"13","author":"de Graaf","year":"2019","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"B26","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s00421-009-1302-4","article-title":"Thermometry and calorimetry assessment of sweat response during exercise in the heat","volume":"108","author":"Flouris","year":"","journal-title":"Eur. J. Appl. Physiol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"N35","DOI":"10.1088\/0967-3334\/31\/5\/N01","article-title":"The validity of tympanic and exhaled breath temperatures for core temperature measurement","volume":"31","author":"Flouris","year":"","journal-title":"Physiol. Meas."},{"key":"B28","first-page":"225","article-title":"Non-invasive measures of core temperature versus ingestible thermistor during exercise in the heat","volume":"10","author":"Fogt","year":"2017","journal-title":"Int. J. Exerc. Sci."},{"key":"B29","doi-asserted-by":"publisher","first-page":"388","DOI":"10.3109\/03091902.2013.816380","article-title":"Clinical applications and issues of oxygen saturation level measurements obtained from peripheral sites","volume":"37","author":"Foo","year":"2013","journal-title":"J. Med. Eng. Technol."},{"key":"B30","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1089\/ther.2019.0009","article-title":"Cerebral autoregulation is impaired during deep Hypothermia-A porcine multimodal neuromonitoring study","volume":"10","author":"Gaasch","year":"2020","journal-title":"Ther. Hypothermia Temp. Manag."},{"key":"B31","doi-asserted-by":"publisher","first-page":"157","DOI":"10.4085\/1062-6050-45.2.157","article-title":"Aural canal, esophageal, and rectal temperatures during exertional heat stress and the subsequent recovery period","volume":"45","author":"Gagnon","year":"2010","journal-title":"J. Athl. Train"},{"key":"B32","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/S0001-6519(04)78492-7","article-title":"Otologic determining factors on infra-red tympanic thermometry in children","volume":"55","author":"Garc\u00eda Callejo","year":"2004","journal-title":"Acta Otorrinolaringol. Esp."},{"key":"B33","doi-asserted-by":"publisher","first-page":"6948","DOI":"10.1038\/s41598-017-06925-2","article-title":"Hearables: multimodal physiological in-ear sensing","volume":"7","author":"Goverdovsky","year":"2017","journal-title":"Sci. Rep."},{"key":"B34","doi-asserted-by":"publisher","first-page":"S63","DOI":"10.1016\/j.resp.2009.04.005","article-title":"The double sensor-a non-invasive device to continuously monitor core temperature in humans on earth and in space","volume":"169","author":"Gunga","year":"2009","journal-title":"Respir. Physiol. Neurobiol."},{"key":"B35","doi-asserted-by":"publisher","first-page":"164","DOI":"10.23736\/S0025-7826.18.02824-7","article-title":"Comparison of two methods for determination of core temperature during running velocity at maximal lactate steady state","volume":"71","author":"Harmanci","year":"2018","journal-title":"Med. Dello Sport."},{"key":"B36","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1080\/03091900600711324","article-title":"The effect of factors such as handedness, sex and age on body temperature measured by an infrared \u201ctympanic\u201d thermometer","volume":"30","author":"Heusch","year":"2006","journal-title":"J. Med. Eng. Technol."},{"key":"B37","doi-asserted-by":"publisher","first-page":"530","DOI":"10.14198\/jhse.2018.133.05","article-title":"Comparisons in heart rate readings between the bioconnected wireless exercise earpiece and a Polar T31-coded chest strap during a GXT","volume":"13","author":"Higgins","year":"2018","journal-title":"J. Hum. Sport Exerc."},{"key":"B38","doi-asserted-by":"publisher","first-page":"R398","DOI":"10.1152\/ajpregu.00270.2015","article-title":"Hypoxemia, oxygen content, and the regulation of cerebral blood flow","volume":"310","author":"Hoiland","year":"2016","journal-title":"Am. J. Physiol. Regul. Integr. Comp. Physiol"},{"key":"B39","unstructured":"Medical Electrical Equipment \u2014 Part 2-56: Particular Requirements for Basic Safety and Essential Performance of Clinical Thermometers for Body Temperature Measurement. ISO2017"},{"key":"B40","unstructured":"Medical Electrical Equipment \u2014 Part 2-61: Particular Requirements for Basic Safety and Essential Performance of Pulse Oximeter Equipment. ISO2017"},{"key":"B41","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1080\/110241500447218","article-title":"Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers","volume":"166","author":"Jensen","year":"2000","journal-title":"Eur. J. Surg."},{"key":"B42","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1159\/000329376","article-title":"Local head and neck cooling leads to hypothermia in healthy volunteers","volume":"32","author":"Kallm\u00fcnzer","year":"2011","journal-title":"Cerebrovasc. Dis"},{"key":"B43","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1017\/S1049023X15005038","article-title":"Accuracy of tympanic temperature measurement in firefighters completing a simulated structural firefighting task","volume":"30","author":"Keene","year":"2015","journal-title":"Prehosp. Disaster Med."},{"key":"B44","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1080\/03091900600711381","article-title":"Reliability of an infrared forehead skin thermometer for core temperature measurements","volume":"30","author":"Kistemaker","year":"2006","journal-title":"J. Med. Eng. Technol."},{"key":"B45","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0967-3334\/27\/1\/R01","article-title":"Pulse oximetry in the oesophagus","volume":"27","author":"Kyriacou","year":"2006","journal-title":"Physiol. Meas"},{"key":"B46","doi-asserted-by":"publisher","first-page":"1046","DOI":"10.1249\/MSS.0000000000000183","article-title":"Earbud-based sensor for the assessment of energy expenditure, HR, and VO2max","volume":"46","author":"Leboeuf","year":"2014","journal-title":"Med. Sci. Sports Exerc."},{"key":"B47","doi-asserted-by":"publisher","first-page":"714","DOI":"10.2486\/indhealth.MS1291","article-title":"Validity of infrared tympanic temperature for the evaluation of heat strain while wearing impermeable protective clothing in hot environments","volume":"49","author":"Lee","year":"2011","journal-title":"Ind. Health"},{"key":"B48","doi-asserted-by":"publisher","first-page":"939","DOI":"10.2486\/indhealth.ms1291","article-title":"Core temperature measurement during supine exercise: esophageal, rectal, and intestinal temperatures","volume":"71","author":"Lee","year":"2000","journal-title":"Aviat. Space Environ. Med."},{"key":"B49","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/B978-0-12-418662-0.00023-4","article-title":"\u201cApplication of optical heart rate monitoring,\u201d","volume-title":"Werable Sensors: Fundamentals, Implementation and Applications","author":"Lemay","year":"2014"},{"key":"B50","doi-asserted-by":"crossref","first-page":"347","DOI":"10.47102\/annals-acadmedsg.V37N4p347","article-title":"Human thermoregulation and measurement of body temperature in exercise and clinical settings","volume":"37","author":"Lim","year":"2008","journal-title":"Ann. Acad. Med. Singap"},{"key":"B51","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1080\/03091900600711415","article-title":"The vagaries of ear temperature assessment","volume":"30","author":"McCarthy","year":"2006","journal-title":"J. Med. Eng. Technol."},{"key":"B52","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/s10439-018-02115-x","article-title":"Validity of skin, oral and tympanic temperatures during exercise in the heat: effects of wind and sweat","volume":"47","author":"Mor\u00e1n-Navarro","year":"2019","journal-title":"Ann. Biomed. Eng."},{"key":"B53","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1080\/00140130110068933","article-title":"Prediction of rectal temperature from ear canal temperature","volume":"44","author":"Muir","year":"2001","journal-title":"Ergonomics."},{"key":"B54","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1186\/s12874-018-0611-x","article-title":"Systematic review or scoping review? Guidance for authors when choosing between a systematic or scoping review approach","volume":"18","author":"Munn","year":"2018","journal-title":"BMC Med. Res. Methodol."},{"key":"B55","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1016\/j.jemermed.2007.10.061","article-title":"Infrared ear thermometry in water-related accidents-not a good choice","volume":"38","author":"Muth","year":"2010","journal-title":"J. Emerg. Med."},{"key":"B56","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1539\/joh.L9160","article-title":"Technique for continuously monitoring core body temperatures to prevent heat stress disorders in workers engaged in physical labor","volume":"52","author":"Nagano","year":"2010","journal-title":"J. Occup. Health"},{"key":"B57","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1007\/s00484-017-1333-1","article-title":"Development of a method for estimating oesophageal temperature by multi-locational temperature measurement inside the external auditory canal","volume":"61","author":"Nakada","year":"2017","journal-title":"Int. J. Biometeorol."},{"key":"B58","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1021\/acssensors.7b00247","article-title":"3D printed \u201cEarable\u201d smart devices for real-time detection of core body temperature","volume":"2","author":"Ota","year":"2017","journal-title":"ACS Sens."},{"key":"B59","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1186\/s13643-016-0384-4","article-title":"Rayyan\u2014a web and mobile app for systematic reviews","volume":"5","author":"Ouzzani","year":"2016","journal-title":"Syst. Rev."},{"key":"B60","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1016\/B978-0-444-64074-1.00033-1","article-title":"Accidental hypothermia","volume":"157","author":"Paal","year":"2018","journal-title":"Handb. Clin. Neurol."},{"key":"B61","volume-title":"Evaluation of Wearable Optical Heart Rate Monitoring Sensors","author":"Parak","year":"2018"},{"key":"B62","doi-asserted-by":"publisher","first-page":"23402","DOI":"10.3390\/s150923402","article-title":"Wearable sensing of in-ear pressure for heart rate monitoring with a piezoelectric sensor","volume":"15","author":"Park","year":"2015","journal-title":"Sensors"},{"key":"B63","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.resuscitation.2019.03.017","article-title":"Hypothermia outcome prediction after extracorporeal life support for hypothermic cardiac arrest patients: an external validation of the HOPE score","volume":"139","author":"Pasquier","year":"2019","journal-title":"Resuscitation"},{"key":"B64","doi-asserted-by":"publisher","first-page":"3641","DOI":"10.3390\/s19173641","article-title":"In-ear pulse rate measurement: a valid alternative to heart rate derived from electrocardiography?","volume":"19","author":"Passler","year":"2019","journal-title":"Sensors"},{"key":"B65","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/0952-8180(96)00103-1","article-title":"Comparison of esophageal, tympanic, and forehead skin temperatures in adult patients","volume":"8","author":"Patel","year":"1996","journal-title":"J. Clin. Anesth."},{"key":"B66","doi-asserted-by":"publisher","first-page":"1","DOI":"10.11124\/jbisrir-2016-2838","article-title":"In no uncertain terms: the importance of a defined objective in scoping reviews","volume":"14","author":"Peters","year":"2016","journal-title":"JBI Database Syst. Rev. Implement Rep."},{"key":"B67","doi-asserted-by":"publisher","first-page":"855","DOI":"10.3390\/s20030855","article-title":"Wearable sensor system to monitor physical activity and the physiological effects of heat exposure","volume":"20","author":"Pham","year":"2020","journal-title":"Sensors"},{"key":"B68","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1109\/MPRV.2010.91","article-title":"Cardiovascular monitoring using earphones and a mobile device","volume":"11","author":"Poh","year":"2012","journal-title":"IEEE Pervas. Comp."},{"key":"B69","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1109\/TITB.2010.2042607","article-title":"Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography","volume":"14","author":"Poh","year":"2010","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"B70","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1109\/TPAMI.2011.102","article-title":"A unified framework for biometric expert fusion incorporating quality measures","volume":"34","author":"Poh","year":"2012","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"B71","doi-asserted-by":"publisher","first-page":"2464","DOI":"10.1111\/sms.13294","article-title":"Accidental hypothermia in recreational activities in the mountains: a narrative review","volume":"28","author":"Procter","year":"2018","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"B72","doi-asserted-by":"publisher","first-page":"136","DOI":"10.3109\/10903127.2011.614047","article-title":"Estimating core temperature with external devices after exertional heat stress in thermal protective clothing","volume":"16","author":"Pryor","year":"2012","journal-title":"Prehosp. Emerg. Care"},{"key":"B73","doi-asserted-by":"publisher","first-page":"249","DOI":"10.3109\/03091901003663836","article-title":"New standards for devices used for the measurement of human body temperature","volume":"34","author":"Ring","year":"2010","journal-title":"J. Med. Eng. Technol."},{"key":"B74","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1111\/j.1365-2044.1990.tb14892.x","article-title":"Nasal pulse oximetry overestimates oxygen saturation","volume":"45","author":"Rosenberg","year":"1990","journal-title":"Anaesthesia"},{"key":"B75","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s00405-005-0966-6","article-title":"Effect of the status after ear surgery and ear pathology on the results of infrared tympanic thermometry","volume":"263","author":"Schm\u00e4l","year":"2006","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"B76","doi-asserted-by":"publisher","first-page":"639","DOI":"10.3389\/fphys.2018.00639","article-title":"Heart rate monitoring in team sports-a conceptual framework for contextualizing heart rate measures for training and recovery prescription","volume":"9","author":"Schneider","year":"2018","journal-title":"Front. Physiol."},{"key":"B77","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/s13049-015-0148-5","article-title":"The impact of environmental factors in pre-hospital thermistor-based tympanic temperature measurement: a pilot field study","volume":"23","author":"Skaiaa","year":"2015","journal-title":"Scand. J. Trauma Resusc. Emerg. Med."},{"key":"B78","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1111\/sms.13651","article-title":"Lung function and oxygen saturation after participation in Norseman Xtreme Triathlon","volume":"30","author":"Stensrud","year":"2020","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"B79","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.resuscitation.2019.05.041","article-title":"The integration of prehospital standard operating procedures and in-hospital HOPE score for management of hypothermic patients in cardiac arrest","volume":"141","author":"Strapazzon","year":"2019","journal-title":"Resuscitation"},{"key":"B80","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1089\/ham.2014.1008","article-title":"Pre-hospital core temperature measurement in accidental and therapeutic hypothermia","volume":"15","author":"Strapazzon","year":"2014","journal-title":"High Alt. Med. Biol"},{"key":"B81","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/s13049-015-0172-5","article-title":"Influence of low ambient temperature on epitympanic temperature measurement: a prospective randomized clinical study","volume":"23","author":"Strapazzon","year":"2015","journal-title":"Scand. J. Trauma Resusc. Emerg. Med."},{"key":"B82","doi-asserted-by":"publisher","first-page":"944","DOI":"10.12968\/bjon.2013.22.16.942","article-title":"Assessment of body temperature measurement options","volume":"942","author":"Sund-Levander","year":"2013","journal-title":"Br. J. Nurs. 22"},{"key":"B83","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1620\/tjem.222.89","article-title":"The validity of mass body temperature screening with ear thermometers in a warm thermal environment","volume":"222","author":"Suzuki","year":"2010","journal-title":"Tohoku J. Exp. Med"},{"key":"B84","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.joto.2018.09.001","article-title":"Does central tympanic membrane perforation affect infrared tympanic thermometer measurements in adults?","volume":"13","author":"Tasli","year":"2018","journal-title":"J. Otol."},{"key":"B85","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1088\/0967-3334\/32\/9\/004","article-title":"Limitations of temperature measurement in the aural canal with an ear mould integrated sensor","volume":"32","author":"Teunissen","year":"2011","journal-title":"Physiol. Measure."},{"key":"B86","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1109\/EMBC.2016.7590689","article-title":"Asynchronous noise removal for earbud-based PPG sensors","volume":"2016","author":"Tomita","year":"2016","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"B87","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/ecj.12019","article-title":"An earbud-based photoplethysmography and its application","volume":"101","author":"Tomita","year":"2018","journal-title":"Electron. Commun. Japn."},{"key":"B88","doi-asserted-by":"publisher","first-page":"467","DOI":"10.7326\/M18-0850","article-title":"PRISMA Extension for Scoping Reviews (PRISMA-ScR): checklist and explanation","volume":"169","author":"Tricco","year":"2018","journal-title":"Ann. Intern. Med"},{"key":"B89","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1109\/TBME.2012.2196276","article-title":"Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: results of a human hypoxia study","volume":"59","author":"Venema","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B90","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1109\/TITB.2009.2033268","article-title":"In-ear vital signs monitoring using a novel microoptic reflective sensor","volume":"13","author":"Vogel","year":"2009","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"B91","doi-asserted-by":"publisher","first-page":"171214","DOI":"10.1098\/rsos.171214","article-title":"Hearables: feasibility of recording cardiac rhythms from head and in-ear locations","volume":"4","author":"von Rosenberg","year":"2017","journal-title":"R Soc. Open Sci."},{"key":"B92","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1249\/MSS.0b013e31815cc43e","article-title":"The effect of cool water ingestion on gastrointestinal pill temperature","volume":"40","author":"Wilkinson","year":"2008","journal-title":"Med. Sci. Sports Exerc."},{"key":"B93","doi-asserted-by":"publisher","first-page":"1384","DOI":"10.1113\/EP087647","article-title":"Cognitive performance is associated with cerebral oxygenation and peripheral oxygen saturation, but not plasma catecholamines, during graded normobaric hypoxia","volume":"104","author":"Williams","year":"2019","journal-title":"Exp. Physiol"},{"key":"B94","doi-asserted-by":"publisher","first-page":"692","DOI":"10.3357\/ASEM.3542.2013","article-title":"A novel method to detect heat illness under severe conditions by monitoring tympanic temperature","volume":"84","author":"Yamakoshi","year":"2013","journal-title":"Aviat. Space Environ. Med."},{"key":"B95","doi-asserted-by":"publisher","first-page":"494","DOI":"10.11239\/jsmbe.48.494","article-title":"Development of a core body thermometer with built-in earphone for continuous monitoring in GT car racing athletes","volume":"48","author":"Yamakoshi","year":"2010","journal-title":"Transac. Japan. Soc. Med. Biol. Eng."}],"container-title":["Frontiers in Physiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/article\/10.3389\/fphys.2020.568886\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T17:57:15Z","timestamp":1696874235000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/article\/10.3389\/fphys.2020.568886\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,16]]},"references-count":95,"alternative-id":["10.3389\/fphys.2020.568886"],"URL":"https:\/\/doi.org\/10.3389\/fphys.2020.568886","relation":{},"ISSN":["1664-042X"],"issn-type":[{"value":"1664-042X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,16]]},"article-number":"568886"}}