{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T00:55:39Z","timestamp":1785891339588,"version":"3.56.0"},"reference-count":57,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,7,1]],"date-time":"2021-07-01T00:00:00Z","timestamp":1625097600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["1R01EB018302"],"award-info":[{"award-number":["1R01EB018302"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["CDS&amp;E \\#1508794"],"award-info":[{"award-number":["CDS&amp;E \\#1508794"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["NSF Big Data Science &amp; Engineering grant \\#1918692"],"award-info":[{"award-number":["NSF Big Data Science &amp; Engineering grant \\#1918692"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006785","name":"Google","doi-asserted-by":"publisher","award":["Google ATAP grant"],"award-info":[{"award-number":["Google ATAP grant"]}],"id":[{"id":"10.13039\/100006785","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Physiol."],"abstract":"<jats:p>\n                    Diastolic dysfunction is a common pathology occurring in about one third of patients affected by heart failure. This condition may not be associated with a marked decrease in cardiac output or systemic pressure and therefore is more difficult to diagnose than its systolic counterpart. Compromised relaxation or increased stiffness of the left ventricle induces an increase in the upstream pulmonary pressures, and is classified as secondary or group II pulmonary hypertension (2018 Nice classification). This may result in an increase in the right ventricular afterload leading to right ventricular failure. Elevated pulmonary pressures are therefore an important clinical indicator of diastolic heart failure (sometimes referred to as\n                    <jats:italic>heart failure with preserved ejection fraction<\/jats:italic>\n                    , HFpEF), showing significant correlation with associated mortality. However, accurate measurements of this quantity are typically obtained through invasive catheterization and after the onset of symptoms. In this study, we use the hemodynamic consistency of a differential-algebraic circulation model to predict pulmonary pressures in adult patients from other, possibly non-invasive, clinical data. We investigate several aspects of the problem, including the ability of model outputs to represent a sufficiently wide pathologic spectrum, the identifiability of the model's parameters, and the accuracy of the predicted pulmonary pressures. We also find that a classifier using the assimilated model parameters as features is free from the problem of missing data and is able to detect pulmonary hypertension with sufficiently high accuracy. For a cohort of 82 patients suffering from various degrees of heart failure severity, we show that systolic, diastolic, and wedge pulmonary pressures can be estimated on average within 8, 6, and 6 mmHg, respectively. We also show that, in general, increased data availability leads to improved predictions.\n                  <\/jats:p>","DOI":"10.3389\/fphys.2021.666915","type":"journal-article","created":{"date-parts":[[2021,7,1]],"date-time":"2021-07-01T12:07:59Z","timestamp":1625141279000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Predictive Modeling of Secondary Pulmonary Hypertension in Left Ventricular Diastolic Dysfunction"],"prefix":"10.3389","volume":"12","author":[{"given":"Karlyn K.","family":"Harrod","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey L.","family":"Rogers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey A.","family":"Feinstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison L.","family":"Marsden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniele E.","family":"Schiavazzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,7,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.jmbbm.2019.04.037","article-title":"Bayesian inference of constitutive model parameters from uncertain uniaxial experiments on murine tendons","volume":"96","author":"Akintunde","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater"},{"key":"B2","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1109\/10.148394","article-title":"Comparison of algorithms for tracking short-term changes in arterial circulation parameters","volume":"39","author":"Avanzolini","year":"1992","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B3","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/0020-7101(88)90006-2","article-title":"CADCS simulation of the closed-loop cardiovascular system","volume":"22","author":"Avanzolini","year":"1988","journal-title":"Int. J. Biomed. Comput"},{"key":"B4","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1109\/TBME.1985.325490","article-title":"Time-varying mechanical properties of the left ventricle-a computer simulation","volume":"32","author":"Avanzolini","year":"1985","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B5","doi-asserted-by":"publisher","first-page":"502","DOI":"10.7326\/0003-4819-117-6-502","article-title":"Left ventricular diastolic dysfunction as a cause of congestive heart failure: mechanisms and management","volume":"117","author":"Bonow","year":"1992","journal-title":"Ann. Intern. Med"},{"key":"B6","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/0141-5425(87)90094-X","article-title":"Model selection for ventricular mechanics: a sensitivity analysis approach","volume":"9","author":"Cappello","year":"1987","journal-title":"J. Biomed. Eng"},{"key":"B7","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1613\/jair.953","article-title":"Smote: synthetic minority over-sampling technique","volume":"16","author":"Chawla","year":"2002","journal-title":"J. Artif. Intell. Res"},{"key":"B8","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1109\/TBME.1980.326687","article-title":"A two-stage identification scheme for the determination of the parameters of a model of left heart and systemic circulation","volume":"27","author":"Clark","year":"1980","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B9","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1109\/PGEC.1965.264137","article-title":"Geometrical and statistical properties of systems of linear inequalities with applications in pattern recognition","volume":"14","author":"Cover","year":"1965","journal-title":"IEEE Trans. Electron. Comput"},{"key":"B10","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1111\/j.1467-9868.2006.00553.x","article-title":"Sequential Monte Carlo samplers","volume":"68","author":"Del Moral","year":"2006","journal-title":"J. R. Stat. Soc. B Stat. Methodol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1109\/TBME.1977.326205","article-title":"Parameter estimation of a simple model of the left ventricle and of the systemic vascular bed, with particular attention to the physical meaning of the left ventricular parameters","volume":"24","author":"Deswysen","year":"1977","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B12","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/BF02443290","article-title":"Quantitative evaluation of the systemic arterial bed by parameter estimation of a simple model","volume":"18","author":"Deswysen","year":"1980","journal-title":"Med. Biol. Eng. Comput"},{"key":"B13","unstructured":"Normal Hemodynamic Parameters and Laboratory Values2009"},{"key":"B14","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1164\/rccm.200811-1691OC","article-title":"Accuracy of doppler echocardiography in the hemodynamic assessment of pulmonary hypertension","volume":"179","author":"Fisher","year":"2009","journal-title":"Am. J. Respir. Crit. Care Med"},{"key":"B15","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.1093\/eurheartj\/ehp297","article-title":"Guidelines for the diagnosis and treatment of pulmonary hypertension","volume":"30","author":"Gali\u00e8","year":"2009","journal-title":"Eur. Heart J"},{"key":"B16","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1214\/ss\/1177011136","article-title":"Inference from iterative simulation using multiple sequences","volume":"7","author":"Gelman","year":"1992","journal-title":"Statist. Sci"},{"key":"B17","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1016\/S0735-1097(83)80278-2","article-title":"Reproducibility of left ventricular volumes by two-dimensional echocardiography","volume":"2","author":"Gordon","year":"1983","journal-title":"J. Am. Coll. Cardiol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1214\/aoms\/1177729694","article-title":"On information and sufficiency","volume":"22","author":"Kullback","year":"1951","journal-title":"Ann. Math. Stat"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1016\/j.jacc.2008.11.051","article-title":"Pulmonary hypertension in heart failure with preserved ejection fraction: a community-based study","volume":"53","author":"Lam","year":"2009","journal-title":"J. Am. Coll. Cardiol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1038\/nature14539","article-title":"Deep learning","volume":"521","author":"LeCun","year":"2015","journal-title":"Nature"},{"key":"B21","first-page":"4","article-title":"Naive (Bayes) at forty: the independence assumption in information retrieval,","volume-title":"European Conference on Machine Learning","author":"Lewis","year":"1998"},{"key":"B22","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.ins.2017.05.008","article-title":"Clustering-based undersampling in class-imbalanced data","volume":"409","author":"Lin","year":"2017","journal-title":"Inform. Sci"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1742-4682-8-14","article-title":"Modeling left ventricular diastolic dysfunction: classification and key indicators","volume":"8","author":"Luo","year":"2011","journal-title":"Theor. Biol. Med. Modell"},{"key":"B24","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1080\/10976640600572889","article-title":"Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance","volume":"8","author":"Maceira","year":"2006","journal-title":"J. Cardiovasc. Magn. Reson"},{"key":"B25","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1109\/TAC.1985.1103950","article-title":"Adaptive control of left ventricular bypass assist devices","volume":"30","author":"McInnis","year":"1985","journal-title":"IEEE Trans. Autom. Control"},{"key":"B26","doi-asserted-by":"publisher","first-page":"H2076","DOI":"10.1152\/ajpheart.2001.280.5.H2076","article-title":"Modeling of the norwood circulation: effects of shunt size, vascular resistances, and heart rate","volume":"280","author":"Migliavacca","year":"2001","journal-title":"Am. J. Physiol. Heart Circ. Physiol"},{"key":"B27","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/0033-0620(76)90023-2","article-title":"Assessment of passive elastic stiffness of cardiac muscle: mathematical concepts, physiologic and clinical considerations, directions of future research","volume":"18","author":"Mirsky","year":"1976","journal-title":"Prog. Cardiovas. Dis."},{"key":"B28","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1161\/CIR.0000000000000366","article-title":"Executive summary: heart disease and stroke statistics-2016 update: a report from the american heart association","volume":"133","author":"Mozaffarian","year":"2016","journal-title":"Circulation"},{"key":"B29","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1093\/comjnl\/7.4.308","article-title":"A simplex method for function minimization","volume":"7","author":"Nelder","year":"1965","journal-title":"Comput. J"},{"key":"B30","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/j.jcmg.2018.12.034","article-title":"Diastolic dysfunction and heart failure with preserved ejection fraction: understanding mechanisms by using noninvasive methods","volume":"13","author":"Obokata","year":"2020","journal-title":"JACC Cardiovasc. Imaging"},{"key":"B31","doi-asserted-by":"publisher","first-page":"2162","DOI":"10.1016\/j.jbiomech.2015.11.030","article-title":"Data assimilation and modelling of patient-specific single-ventricle physiology with and without valve regurgitation","volume":"49","author":"Pant","year":"2016","journal-title":"J. Biomech"},{"key":"B32","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.ppedcard.2010.09.004","article-title":"Modeling of systemic-to-pulmonary shunts in newborns with a univentricular circulation: state of the art and future directions","volume":"30","author":"Pennati","year":"2010","journal-title":"Prog. Pediatr. Cardiol"},{"key":"B33","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/S1350-4533(96)00071-9","article-title":"A mathematical model of circulation in the presence of the bidirectional cavopulmonary anastomosis in children with a univentricular heart","volume":"19","author":"Pennati","year":"1997","journal-title":"Med. Eng. Phys"},{"key":"B34","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.cmpb.2011.10.013","article-title":"Validation of subject-specific cardiovascular system models from porcine measurements","volume":"109","author":"Revie","year":"2013","journal-title":"Comput. Methods Prog. Biomed"},{"key":"B35","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1109\/TBME.1967.4502495","article-title":"Difference-differential equations for fluid flow in distensible tubes","volume":"14","author":"Rideout","year":"1967","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B36","doi-asserted-by":"publisher","first-page":"577","DOI":"10.2307\/1913267","article-title":"Identification in parametric models","volume":"39","author":"Rothenberg","year":"1971","journal-title":"Econometrica"},{"key":"B37","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/BF02368178","article-title":"Identification algorithm for systemic arterial parameters with application to total artificial heart control","volume":"21","author":"Ruchti","year":"1993","journal-title":"Ann. Biomed. Eng"},{"key":"B38","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1177\/096228029900800102","article-title":"Multiple imputation: a primer","volume":"8","author":"Schafer","year":"1999","journal-title":"Statist. Methods Med. Res"},{"key":"B39","doi-asserted-by":"publisher","first-page":"e02799","DOI":"10.1002\/cnm.2799","article-title":"Patient-specific parameter estimation in single-ventricle lumped circulation models under uncertainty","volume":"33","author":"Schiavazzi","year":"2016","journal-title":"Int. J. Numer. Methods Biomed. Eng"},{"key":"B40","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1161\/CIRCULATIONAHA.114.010637","article-title":"Phenomapping for novel classification of heart failure with preserved ejection fraction","volume":"131","author":"Shah","year":"2015","journal-title":"Circulation"},{"key":"B41","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1111\/j.1525-1594.1991.tb00769.x","article-title":"Investigation of parameter estimator and adaptive controller for assist pump by computer simulation","volume":"15","author":"Shimooka","year":"1991","journal-title":"Artif. Organs"},{"key":"B42","doi-asserted-by":"publisher","first-page":"D34","DOI":"10.1016\/j.jacc.2013.10.029","article-title":"Updated clinical classification of pulmonary hypertension","volume":"62","author":"Simonneau","year":"2013","journal-title":"J. Am. Coll. Cardiol"},{"key":"B43","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1109\/TBME.1969.4502663","article-title":"Computer simulation studies of the venous circulation","volume":"16","author":"Snyder","year":"1969","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"B44","doi-asserted-by":"publisher","first-page":"2635","DOI":"10.1007\/s10439-010-0011-9","article-title":"Tuning multidomain hemodynamic simulations to match physiological measurements","volume":"38","author":"Spilker","year":"2010","journal-title":"Ann. Biomed. Eng"},{"key":"B45","doi-asserted-by":"publisher","first-page":"1367","DOI":"10.1016\/j.jtcvs.2012.07.029","article-title":"Assessment of cardiovascular function by combining clinical data with a computational model of the cardiovascular system","volume":"145","author":"Sughimoto","year":"2013","journal-title":"J. Thorac. Cardiovasc. Surg"},{"key":"B46","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1142\/S0218001409007326","article-title":"Classification of imbalanced data: a review","volume":"23","author":"Sun","year":"2009","journal-title":"Int. J. Pattern Recogn. Artif. Intell"},{"key":"B47","doi-asserted-by":"publisher","first-page":"355","DOI":"10.3389\/fphys.2013.00355","article-title":"Analysis of cardiovascular dynamics in pulmonary hypertensive C57BL6\/J mice","volume":"4","author":"Tewari","year":"2013","journal-title":"Front. Physiol"},{"key":"B48","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/0003-4975(90)90095-N","article-title":"Reversibility of pulmonary artery hypertension in aortic stenosis after aortic valve replacement","volume":"50","author":"Tracy","year":"1990","journal-title":"Ann. Thorac. Surg"},{"key":"B49","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.compfluid.2016.05.015","article-title":"Automated tuning for parameter identification and uncertainty quantification in multi-scale coronary simulations","volume":"142","author":"Tran","year":"2017","journal-title":"Comput. Fluids"},{"key":"B50","doi-asserted-by":"publisher","first-page":"H1733","DOI":"10.1152\/ajpheart.1998.275.5.H1733","article-title":"Interaction between carotid baroregulation and the pulsating heart: a mathematical model","volume":"275","author":"Ursino","year":"1998","journal-title":"Am. J. Physiol. Heart Circ. Physiol"},{"key":"B51","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.envsoft.2015.08.013","article-title":"Markov chain Monte Carlo simulation using the DREAM software package: theory, concepts, and MATLAB implementation","volume":"75","author":"Vrugt","year":"2016","journal-title":"Environ. Model. Softw"},{"key":"B52","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1515\/IJNSNS.2009.10.3.273","article-title":"Accelerating Markov chain Monte Carlo simulation by differential evolution with self-adaptive randomized subspace sampling","volume":"10","author":"Vrugt","year":"2009","journal-title":"Int. J. Nonlin. Sci. Numer. Simul"},{"key":"B53","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s12265-018-9793-1","article-title":"Predicting the time course of ventricular dilation and thickening using a rapid compartmental model","volume":"11","author":"Witzenburg","year":"2018","journal-title":"J. Cardiovasc. Transl. Res"},{"key":"B54","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.echo.2011.03.008","article-title":"Pulmonary artery acceleration time provides an accurate estimate of systolic pulmonary arterial pressure during transthoracic echocardiography","volume":"24","author":"Yared","year":"2011","journal-title":"J. Am. Soc. Echocardiogr"},{"key":"B55","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1114\/1.1380420","article-title":"Minimally invasive estimation of systemic vascular parameters","volume":"29","author":"Yu","year":"2001","journal-title":"Ann. Biomed. Eng"},{"key":"B56","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1109\/9.679017","article-title":"Estimation of systemic vascular bed parameters for artificial heart control","volume":"43","author":"Yu","year":"1998","journal-title":"IEEE Trans. Autom. Control"},{"key":"B57","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1161\/hc1102.105289","article-title":"New concepts in diastolic dysfunction and diastolic heart failure: part I diagnosis, prognosis, and measurements of diastolic function","volume":"105","author":"Zile","year":"2002","journal-title":"Circulation"}],"container-title":["Frontiers in Physiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2021.666915\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,16]],"date-time":"2021-07-16T08:11:41Z","timestamp":1626423101000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2021.666915\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,1]]},"references-count":57,"alternative-id":["10.3389\/fphys.2021.666915"],"URL":"https:\/\/doi.org\/10.3389\/fphys.2021.666915","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2020.04.23.20073601","asserted-by":"object"}]},"ISSN":["1664-042X"],"issn-type":[{"value":"1664-042X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,1]]},"article-number":"666915"}}