{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T01:44:38Z","timestamp":1778291078672,"version":"3.51.4"},"reference-count":32,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T00:00:00Z","timestamp":1672963200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003399","name":"Science and Technology Commission of Shanghai Municipality","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003399","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Physiol."],"abstract":"<jats:p><jats:bold>Aims:<\/jats:bold> The study aimed to compare paravalvular leak (PVL) changes after a transcatheter aortic valve replacement (TAVR) with self-expandable prosthesis between different aortic valve morphologies and evaluate the impact of paravalvular leak regression on clinical prognosis.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Patients with aortic stenosis (AS) successfully treated with a self-expandable TAVR who were followed up for at least 1\u00a0year at our centre were consecutively enrolled from January 2016 to August 2019. Paired serial changes in paravalvular leak and other haemodynamic parameters by echocardiography were collected and compared between the bicuspid valve (BAV) and tricuspid aortic valve (TAV). A logistic regression model was used to explore the predictors of paravalvular leak regression (&amp;lt;1 grade) 1\u00a0year after transcatheter aortic valve replacement, while its impact on subsequent clinical outcomes (all-cause mortality and rehospitalisation for heart failure (HF)) was further evaluated using Kaplan\u2013Meier analysis.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> A total of 153 bicuspid valve and 114 tricuspid aortic valve patients were finally enrolled; haemodynamic parameters and paravalvular leak severity were comparable before the discharge between the two groups. The peak transaortic velocity, mean transvalvular gradient, and effective orifice area all significantly improved (<jats:italic>p<\/jats:italic> &amp;lt; 0.05) without intergroup differences at all follow-up timepoints. Significant paravalvular leak reduction was observed only in the TAV group (1.75% <jats:italic>vs.<\/jats:italic> 4.39%, <jats:italic>p<\/jats:italic> = 0.029), while moderate paravalular leak was still more prevalent in BAV (7.19% <jats:italic>vs.<\/jats:italic> 1.75%, <jats:italic>p<\/jats:italic> = 0.041) at the 1-year follow-up. Multivariable analyses identified the bicuspid valve, asymmetric calcification, and undersizing as independent predictors of failure of the 1-year paravalvular leak reduction in patients with mild or moderate paravalvular leak after discharge. Patients without a paravalvular leak reduction within 1 year showed a relatively higher 2-year all-cause mortality and HF (HR: 5.994, 95% CI: 1.691\u201321.240, and <jats:italic>p<\/jats:italic> = 0.053) rates thereafter.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> In AS patients after self-expandable transcatheter aortic valve replacement, paravalvular leak regression within 1\u00a0year was less prevalent in bicuspid valve morphology. The failure of paravalvular leak reduction might lead to an increased risk of poorer prognosis in the long run.<\/jats:p>","DOI":"10.3389\/fphys.2022.1088681","type":"journal-article","created":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T15:12:40Z","timestamp":1673017960000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Aortic valve morphology and paravalvular leak regression after a self-expandable transcatheter aortic valve replacement"],"prefix":"10.3389","volume":"13","author":[{"given":"Qinchun","family":"Jin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shasha","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingfei","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daxin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaochun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junbo","family":"Ge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,1,6]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1001\/jama.2014.3316","article-title":"Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial","volume":"311","author":"Abdel-Wahab","year":"2014","journal-title":"JAMA"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1016\/j.jcin.2019.12.026","article-title":"5-Year outcomes after TAVR with balloon-expandable versus self-expanding valves: Results from the CHOICE randomized clinical trial","volume":"13","author":"Abdel-Wahab","year":"2020","journal-title":"JACC. Cardiovasc. Interv."},{"key":"B3","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.pcad.2021.11.003","article-title":"Transcatheter aortic valve replacement (TAVR): Recent updates","volume":"69","author":"Avvedimento","year":"2021","journal-title":"Prog. Cardiovasc. Dis."},{"key":"B4","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/j.jacc.2018.10.078","article-title":"Long-term durability of transcatheter aortic valve prostheses","volume":"73","author":"Blackman","year":"2019","journal-title":"J. Am. Coll. Cardiol."},{"key":"B5","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.jcin.2021.10.027","article-title":"Propensity-matched 1-year outcomes following transcatheter aortic valve replacement in low-risk bicuspid and tricuspid patients","volume":"15","author":"Deeb","year":"2022","journal-title":"JACC. Cardiovasc. Interv."},{"key":"B6","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1161\/CIRCULATIONAHA.119.043971","article-title":"Impact of sapien 3 balloon-expandable versus evolut R self-expandable transcatheter aortic valve implantation in patients with aortic stenosis: data from a nationwide analysis","volume":"141","author":"Deharo","year":"2020","journal-title":"Circulation"},{"key":"B7","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1016\/j.athoracsur.2010.09.060","article-title":"Automated assessment of the aortic root dimensions with multidetector row computed tomography","volume":"91","author":"Delgado","year":"2011","journal-title":"Ann. Thorac. Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1093\/ehjci\/jex009","article-title":"Relation between calcium burden, echocardiographic stent frame eccentricity and paravalvular leakage after corevalve transcatheter aortic valve implantation","volume":"18","author":"Di Martino","year":"2017","journal-title":"Eur. Heart J. Cardiovasc. Imaging"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.1016\/j.jcin.2020.03.022","article-title":"Transcatheter aortic valve replacement in bicuspid versus tricuspid aortic valves from the STS\/ACC TVT registry","volume":"13","author":"Forrest","year":"2020","journal-title":"JACC. Cardiovasc. Interv."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/j.jacc.2012.08.1039","article-title":"Paravalvular leak after transcatheter aortic valve replacement: the new achilles' heel? A comprehensive review of the literature","volume":"61","author":"Genereux","year":"2013","journal-title":"J. Am. Coll. Cardiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1038\/s41569-018-0147-0","article-title":"Percutaneous management of paravalvular leaks","volume":"16","author":"Giblett","year":"2019","journal-title":"Nat. Rev. Cardiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1136\/heartjnl-2021-319159","article-title":"Percutaneous management of paravalvular leaks","volume":"108","author":"Giblett","year":"2022","journal-title":"Heart"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1093\/ehjci\/jeu162","article-title":"A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation","volume":"15","author":"Jilaihawi","year":"2014","journal-title":"Eur. Heart J. Cardiovasc. Imaging"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1007\/s10554-016-0924-y","article-title":"Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre","volume":"32","author":"Kaya","year":"2016","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"B15","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1016\/j.jcin.2014.03.007","article-title":"Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement","volume":"7","author":"Khalique","year":"2014","journal-title":"JACC. Cardiovasc. Interv."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.1016\/S0140-6736(19)32220-2","article-title":"Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial","volume":"394","author":"Lanz","year":"2019","journal-title":"Lancet"},{"key":"B17","doi-asserted-by":"publisher","first-page":"104501","DOI":"10.1115\/1.4054332","article-title":"Comparison of balloon-expandable valve and self-expandable valve in transcatheter aortic valve replacement: A patient-specific numerical study","volume":"144","author":"Li","year":"2022","journal-title":"J. Biomech. Eng."},{"key":"B18","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.ijcard.2017.12.013","article-title":"Comparison of procedural, clinical and valve performance results of transcatheter aortic valve replacement in patients with bicuspid versus tricuspid aortic stenosis","volume":"254","author":"Liao","year":"2018","journal-title":"Int. J. Cardiol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"e008714","DOI":"10.1161\/CIRCINTERVENTIONS.119.008714","article-title":"Balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis: Insights from the BEAT international collaborative registrys","volume":"13","author":"Mangieri","year":"2020","journal-title":"Circ. Cardiovasc. Interv."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1016\/j.jcmg.2015.07.012","article-title":"Regression of paravalvular aortic regurgitation and remodeling of self-expanding transcatheter aortic valve: an observation from the CoreValve U.S. Pivotal trial","volume":"8","author":"Oh","year":"2015","journal-title":"JACC. Cardiovasc. Imaging"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","article-title":"Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients","volume":"380","author":"Popma","year":"2019","journal-title":"N. Engl. J. Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"104621","DOI":"10.1016\/j.jmbbm.2021.104621","article-title":"Transcatheter aortic valve replacement in bicuspid valves: The synergistic effects of eccentric and incomplete stent deployment","volume":"121","author":"Qiu","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mat."},{"key":"B23","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/s0002-8703(99)70124-9","article-title":"Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up","volume":"138","author":"Rallidis","year":"1999","journal-title":"Am. Heart J."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1674","DOI":"10.1007\/s00380-019-01414-0","article-title":"Hemodynamic comparison of CoreValve and SAPIEN-XT TAVI valves in Japanese patients","volume":"34","author":"Shishido","year":"2019","journal-title":"Heart Vessels"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1016\/j.jtcvs.2007.01.039","article-title":"A classification system for the bicuspid aortic valve from 304 surgical specimens","volume":"133","author":"Sievers","year":"2007","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"B26","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1002\/ccd.28999","article-title":"Mid- to long-term clinical and echocardiographic outcomes after transcatheter aortic valve replacement with a new-generation, self-expandable system","volume":"97","author":"Siqueira","year":"2021","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"B27","doi-asserted-by":"publisher","first-page":"2859","DOI":"10.1016\/j.jacc.2018.09.014","article-title":"Transcatheter aortic valve replacement with a repositionable self-expanding prosthesis: the PORTICO-I trial 1-year outcomes","volume":"72","author":"Sondergaard","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"444","DOI":"10.21037\/acs.2017.09.15","article-title":"Pros and cons of transcatheter aortic valve implantation (TAVI)","volume":"6","author":"Terre","year":"2017","journal-title":"Ann. Cardiothorac. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"2717","DOI":"10.1016\/j.jacc.2021.02.038","article-title":"Valve academic research consortium 3: Updated endpoint definitions for aortic valve clinical research","volume":"77","author":"Varc-3 Writing","year":"2021","journal-title":"J. Am. Coll. Cardiol."},{"key":"B30","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1161\/CIRCULATIONAHA.120.048048","article-title":"Transcatheter aortic valve replacement in bicuspid aortic valve stenosis","volume":"143","author":"Vincent","year":"2021","journal-title":"Circulation"},{"key":"B31","doi-asserted-by":"publisher","DOI":"10.1038\/s41569-022-00734-5","article-title":"Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization","author":"Xiong","year":"2022","journal-title":"Nat. Rev. Cardiol."},{"key":"B32","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1002\/ccd.28226","article-title":"VitaFlow transcatheter valve system in the treatment of severe aortic stenosis: One-year results of a multicenter study","volume":"95","author":"Zhou","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."}],"container-title":["Frontiers in Physiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2022.1088681\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T15:12:44Z","timestamp":1673017964000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2022.1088681\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,6]]},"references-count":32,"alternative-id":["10.3389\/fphys.2022.1088681"],"URL":"https:\/\/doi.org\/10.3389\/fphys.2022.1088681","relation":{},"ISSN":["1664-042X"],"issn-type":[{"value":"1664-042X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,6]]},"article-number":"1088681"}}