{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T11:40:11Z","timestamp":1787226011128,"version":"build-2736575974"},"reference-count":44,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T00:00:00Z","timestamp":1699488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Physiol."],"abstract":"<jats:p>Relaxometry is a field with a glorious and controversial history, and no review will ever do it justice. It is full of egos and inventions, patents and lawsuits, high expectations and deep disillusionments. Rather than a paragraph dedicated to each of these, we want to give it an impressionistic overview, painted over with a coat of personal opinions and ruminations about the future of the field. For those unfamiliar with the Gartner hype cycle, here\u2019s a brief recap. The cycle starts with a technology trigger and goes through a phase of unrealistically inflated expectations. Eventually the hype dies down as implementations fail to deliver on their promise, and disillusionment sets in. Technologies that manage to live through the trough reach the slope of enlightenment, when there is a flurry of second and third generation products that make the initial promise feel feasible again. Finally, we reach the slope of productivity, where mainstream adoption takes off, and more incremental progress is made, eventually reaching steady state in terms of the technology\u2019s visibility. The entire interactive timeline can be viewed at <jats:ext-link>https:\/\/qmrlab.org\/relaxometry\/<\/jats:ext-link>.<\/jats:p>","DOI":"10.3389\/fphys.2023.1281147","type":"journal-article","created":{"date-parts":[[2023,11,13]],"date-time":"2023-11-13T06:30:06Z","timestamp":1699857006000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["The relaxometry hype cycle"],"prefix":"10.3389","volume":"14","author":[{"given":"Nikola","family":"Stikov","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ag\u00e2h","family":"Karakuzu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,11,9]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.neuroimage.2016.05.024","article-title":"High-resolution characterisation of the aging brain using simultaneous quantitative susceptibility mapping (QSM) and R2* measurements at 7 T","volume":"138","author":"Betts","year":"2016","journal-title":"Neuroimage"},{"key":"B2","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.mri.2016.08.021","article-title":"What are normal relaxation times of tissues at 3 T?","volume":"35","author":"Bojorquez","year":"2017","journal-title":"Magn. Reson Imaging"},{"key":"B3","doi-asserted-by":"crossref","DOI":"10.55458\/neurolibre.00014","article-title":"Results of the ISMRM 2020 joint reproducible research and quantitative MR study groups reproducibility challenge on phantom and human brain T1 mapping","volume-title":"NeuroLibre Reproducible Preprints","author":"Boudreau","year":"2023"},{"key":"B4","volume-title":"Quantitative MRI of the brain: principles of physical measurement","author":"Cercignani","year":"2018"},{"key":"B5","doi-asserted-by":"publisher","first-page":"2082","DOI":"10.1002\/mrm.24878","article-title":"Saturation recovery single\u2010shot acquisition (SASHA) for myocardial T1 mapping","volume":"71","author":"Chow","year":"2014","journal-title":"Magnetic Reson. Med."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1002\/mrm.28020","article-title":"Portable and platform\u2010independent MR pulse sequence programs","volume":"83","author":"Cordes","year":"2020","journal-title":"Magnetic Reson. Med."},{"key":"B7","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1002\/mrm.1910040105","article-title":"Errors in T2 estimation using multislice multiple\u2010echo imaging","volume":"4","author":"Crawley","year":"1987","journal-title":"Magnetic Reson. Med."},{"key":"B8","volume-title":"Apparatus and method for detecting cancer in tissue","author":"Damadian","year":"1974"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1126\/science.171.3976.1151","article-title":"Tumor detection by nuclear magnetic resonance","volume":"171","author":"Damadian","year":"1971","journal-title":"Science"},{"key":"B10","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1002\/mrm.20314","article-title":"High\u2010resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2","volume":"53","author":"Deoni","year":"2005","journal-title":"Magnetic Reson. Med. Official J. Int. Soc. Magnetic Reson. Med."},{"key":"B11","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/0730-725x(87)90021-x","article-title":"Rapid calculation of T1 using variable flip angle gradient refocused imaging","volume":"5","author":"Fram","year":"1987","journal-title":"Magn. Reson Imaging"},{"key":"B12","doi-asserted-by":"publisher","first-page":"343","DOI":"10.2214\/ajr.183.2.1830343","article-title":"Musculoskeletal MRI at 3.0 T: relaxation times and image contrast","volume":"183","author":"Gold","year":"2004","journal-title":"Am. J. Roentgenol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.radonc.2020.01.026","article-title":"Quantitative imaging for radiotherapy purposes","volume":"146","author":"Gurney-Champion","year":"2020","journal-title":"Radiotherapy Oncol."},{"key":"B14","unstructured":"Let\u2019s talk about cardiac T1 mapping\n            HafyaneT.\n            KarakuzuA.\n            DuquetteC.\n            MongeonF. P.\n            Cohen-AdadJ.\n            Jerosch-HeroldM.\n          2018"},{"key":"B15","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1097\/RLI.0000000000000365","article-title":"SyMRI of the brain: rapid quantification of relaxation rates and proton density, with synthetic MRI, automatic brain segmentation, and myelin measurement","volume":"52","author":"Hagiwara","year":"2017","journal-title":"Invest Radiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1002\/jmri.27440","article-title":"Synthetic MRI: technologies and applications in neuroradiology","volume":"55","author":"Ji","year":"2022","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B17","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1038\/s41597-022-01571-4","article-title":"qMRI-BIDS: an extension to the brain imaging data structure for quantitative magnetic resonance imaging data","volume":"9","author":"Karakuzu","year":"","journal-title":"Sci. data"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.1002\/mrm.29292","article-title":"Vendor\u2010neutral sequences and fully transparent workflows improve inter\u2010vendor reproducibility of quantitative MRI","volume":"88","author":"Karakuzu","year":"","journal-title":"Magnetic Reson. Med."},{"key":"B19","doi-asserted-by":"publisher","first-page":"2343","DOI":"10.21105\/joss.02343","article-title":"qMRLab: quantitative MRI analysis, under one umbrella","volume":"5","author":"Karakuzu","year":"2020","journal-title":"J. Open Source Softw."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1002\/jmri.26785","article-title":"Assessing effects of scanner upgrades for clinical studies","volume":"50","author":"Keenan","year":"2019","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1544","DOI":"10.1002\/mrm.26235","article-title":"Pulseq: a rapid and hardware\u2010independent pulse sequence prototyping framework","volume":"77","author":"Layton","year":"2017","journal-title":"Magnetic Reson. Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1002\/mrm.27421","article-title":"Establishing intra\u2010and inter\u2010vendor reproducibility of T1 relaxation time measurements with 3T MRI","volume":"81","author":"Lee","year":"2019","journal-title":"Magnetic Reson. Med."},{"key":"B23","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/0022-2364(81)90082-2","article-title":"Compensation for pulse imperfections in NMR spin-echo experiments","volume":"43","author":"Levitt","year":"1981","journal-title":"J. Magnetic Reson. (1969)"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1002\/mrm.21918","article-title":"Rapid water and lipid imaging with T2 mapping using a radial IDEAL\u2010GRASE technique","volume":"61","author":"Li","year":"2009","journal-title":"Magnetic Reson. Med. Official J. Int. Soc. Magnetic Reson. Med."},{"key":"B25","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1063\/1.1684482","article-title":"Time saving in measurement of NMR and EPR relaxation times","volume":"41","author":"Look","year":"1970","journal-title":"Rev. Sci. Instrum."},{"key":"B26","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1038\/nature11971","article-title":"Magnetic resonance fingerprinting","volume":"495","author":"Ma","year":"2013","journal-title":"Nature"},{"key":"B27","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1002\/mrm.1910310614","article-title":"In vivo visualization of myelin water in brain by magnetic resonance","volume":"31","author":"Mackay","year":"1994","journal-title":"Magnetic Reson. Med."},{"key":"B28","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1002\/jmri.23718","article-title":"Practical medical applications of quantitative MR relaxometry","volume":"36","author":"Margaret Cheng","year":"2012","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1016\/j.neuroimage.2009.10.002","article-title":"MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field","volume":"49","author":"Marques","year":"2010","journal-title":"Neuroimage"},{"key":"B30","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1186\/s12968-017-0389-8","article-title":"Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: a consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI)","volume":"19","author":"Messroghli","year":"2017","journal-title":"J. Cardiovasc. magnetic Reson."},{"key":"B31","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/mrm.20110","article-title":"Modified Look\u2010Locker inversion recovery (MOLLI) for high\u2010resolution T1 mapping of the heart","volume":"52","author":"Messroghli","year":"2004","journal-title":"Magnetic Reson. Med. Official J. Int. Soc. Magnetic Reson. Med."},{"key":"B32","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1186\/1532-429X-12-69","article-title":"Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold","volume":"12","author":"Piechnik","year":"2010","journal-title":"J. Cardiovasc. magnetic Reson."},{"key":"B33","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1002\/jmri.1880020512","article-title":"Practical T2 quantitation for clinical applications","volume":"2","author":"Poon","year":"1992","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B34","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1088\/0031-9155\/23\/5\/012","article-title":"A line scan image study of a tumorous rat leg by NMR","volume":"23","author":"Pykett","year":"1978","journal-title":"Phys. Med. Biol."},{"key":"B35","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1038\/nrneurol.2016.166","article-title":"The central vein sign and its clinical evaluation for the diagnosis of multiple sclerosis: a consensus statement from the North American Imaging in Multiple Sclerosis Cooperative","volume":"12","author":"Sati","year":"2016","journal-title":"Nat. Rev. Neurol."},{"key":"B36","doi-asserted-by":"publisher","first-page":"20180926","DOI":"10.1259\/bjr.20180926","article-title":"Towards a standard MRI protocol for multiple sclerosis across the UK","volume":"92","author":"Schmierer","year":"2019","journal-title":"Br. J. Radiology"},{"key":"B37","volume-title":"Quantitative magnetic resonance imaging","author":"Seiberlich","year":"2020"},{"key":"B38","doi-asserted-by":"publisher","first-page":"e2117203119","DOI":"10.1073\/pnas.2117203119","article-title":"Implicit data crimes: machine learning bias arising from misuse of public data","volume":"119","author":"Shimron","year":"2022","journal-title":"Proc. Natl. Acad. Sci."},{"key":"B39","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1002\/mrm.20605","article-title":"T1, T2 relaxation and magnetization transfer in tissue at 3T","volume":"54","author":"Stanisz","year":"2005","journal-title":"Magnetic Reson. Med. Official J. Int. Soc. Magnetic Reson. Med."},{"key":"B40","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1002\/mrm.25135","article-title":"On the accuracy of T1 mapping: searching for common ground","volume":"73","author":"Stikov","year":"2015","journal-title":"Magnetic Reson. Med."},{"key":"B41","doi-asserted-by":"publisher","first-page":"1981","DOI":"10.1002\/mrm.27939","article-title":"Reproducibility and the future of MRI research","volume":"82","author":"Stikov","year":"2019","journal-title":"Magn. Reson Med."},{"key":"B42","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1002\/jmri.28127","article-title":"Bias, repeatability and reproducibility of liver T1 mapping with variable flip angles","volume":"56","author":"Tadimalla","year":"2022","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B43","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s12968-016-0286-6","article-title":"Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T","volume":"18","author":"Teixeira","year":"2016","journal-title":"J. Cardiovasc. magnetic Reson."},{"key":"B44","volume-title":"Quantitative MRI of the brain: measuring changes caused by disease","author":"Tofts","year":"2005"}],"container-title":["Frontiers in Physiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2023.1281147\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,13]],"date-time":"2023-11-13T06:30:11Z","timestamp":1699857011000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2023.1281147\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,9]]},"references-count":44,"alternative-id":["10.3389\/fphys.2023.1281147"],"URL":"https:\/\/doi.org\/10.3389\/fphys.2023.1281147","relation":{},"ISSN":["1664-042X"],"issn-type":[{"value":"1664-042X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,9]]},"article-number":"1281147"}}