{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T06:13:13Z","timestamp":1788415993065,"version":"build-2803163510"},"reference-count":34,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Physiol."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Critical flicker fusion frequency (cFFF) is a rapid, noninvasive index of cortical arousal and visual-cognitive performance that has gained renewed interest in diving and other extreme environments. However, the extent to which ambient illumination and water submersion affect cFFF remains insufficiently characterized.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Nineteen experienced divers (10 females; 24\u00a0\u00b1\u00a03 years) completed cFFF testing on land and at 5\u00a0m water depth under bright (land: 138\u00a0\u00b1\u00a02.4 lx; water: 75\u00a0\u00b1\u00a014.8 lx) and dark (0\u00a0lx) conditions using a manually operated flicker device. Heart rate (HR) and heart rate variability (HRV) were recorded continuously.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>For cFFF, mixed-effects ANOVAs revealed a significant main effect of submersion (p=0.0485) but not illumination (p=0.0754), with higher values in submersion compared to land (+1.4 Hz). Heart rate variability showed a main effect for submersion (p=0.004, +30 ms in submersion) and posthoc differences in dark illumination (p=0.004, +41 ms in submersion). No effects were observed for heart rate or respiration rate. Age showed a low negative correlation with cFFF (r = \u22120.22 to \u22120.40) but not with heart rate or heart rate variability. Sex effects were negligible (|r|&amp;lt;0.32).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Based on the current 10-minute exposure time, cFFF is robust between the applied illuminations, but small absolute effects were observed from submersion. For human performance and diving research, these findings highlight the importance of baseline measures under comparable environmental conditions to prevent obscuring genuine changes in alertness or cognitive performance. Exposure time and ambient illumination should be standardized or reported to improve comparability across studies and operational environments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fphys.2026.1824031","type":"journal-article","created":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T05:21:17Z","timestamp":1788412877000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Critical flicker fusion frequency assessment: robustness across photopic illumination in experienced divers"],"prefix":"10.3389","volume":"17","author":[{"given":"Jochen D.","family":"Schipke","sequence":"first","affiliation":[{"name":"Research Group Experimental Surgery, University Hospital Duesseldorf","place":["Duesseldorf, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Muth","sequence":"additional","affiliation":[{"name":"Institute of Occupational, Social and Environmental Medicine, Heinrich-Heine-University D\u00fcsseldorf, Medical Faculty and University Hospital D\u00fcsseldorf","place":["Frankfurt\/Main, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne-Kathrin","family":"Brebeck","sequence":"additional","affiliation":[{"name":"Artemis Medizinisches Versorgungszentrum (MVZ) Frankfurt","place":["Frankfurt\/Main, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominik","family":"von Hertlein","sequence":"additional","affiliation":[{"name":"Department of Psychology, German Sport University Cologne","place":["Cologne, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabian N.","family":"M\u00f6ller","sequence":"additional","affiliation":[{"name":"Department of Exercise Physiology, German Sport University Cologne","place":["Cologne, Germany"]},{"name":"Department of Aeronauticss and Astroanutics, Massachusetts Institute of Technology","place":["Cambridge, MA, United States"]},{"name":"Department of Human Physiology, University of Oregon","place":["Eugene, OR, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.3389\/fpsyg.2018.02391","article-title":"Editorial: Extreme environments in movement science and sport psychology","volume":"9","author":"Balestra","year":"2018","journal-title":"Front. Psychol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"4063","DOI":"10.1007\/s00421-012-2391-z","article-title":"Persistence of critical flicker fusion frequency impairment after a 33 mfw SCUBA dive: evidence of prolonged nitrogen narcosis","volume":"112","author":"Balestra","year":"2012","journal-title":"Eur. J. Appl. Physiol."},{"key":"B3","doi-asserted-by":"publisher","DOI":"10.3389\/fpsyg.2018.00072","article-title":"Environmental physiology and diving medicine","volume":"9","author":"Bosco","year":"2018","journal-title":"Front. Psychol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1037\/h0064646","article-title":"Beitrag zur Lehre des intermittierenden Lichtreizes der gesunden und kranken Retina","author":"Braunstein","year":"1903","journal-title":"Z. Fr. Psychol. und Physiologie der Sinnesorgane"},{"key":"B5","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1002\/(SICI)1099-1077(200003)15:2<103::AID-HUP149>3.0.CO;2-7","article-title":"Critical flicker fusion threshold: a potentially useful measure for the early detection of Alzheimer\u2019s disease","volume":"15","author":"Curran","year":"2000","journal-title":"Hum. Psychopharmacol. - Clin. Exp."},{"key":"B6","doi-asserted-by":"publisher","first-page":"654","DOI":"10.2307\/1418795","article-title":"Auditory and visual flicker-fusion as measures of fatigue","volume":"68","author":"Davis","year":"1955","journal-title":"Am. J. Psychol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"186","DOI":"10.28920\/dhm49.3.186-191","article-title":"Assessment of sensory sensitivity through critical flicker fusion frequency thresholds after a maximum voluntary apnoea","volume":"49","author":"de As\u00eds Fern\u00e1ndez","year":"2019","journal-title":"Diving Hyperb Med."},{"key":"B8","doi-asserted-by":"publisher","first-page":"3323","DOI":"10.1007\/s00421-021-04798-y","article-title":"Physiological effects of mixed-gas deep sea dives using a closed-circuit rebreather: a field pilot study","volume":"121","author":"Dugrenot","year":"2021","journal-title":"Eur. J. Appl. Physiol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"375","DOI":"10.2307\/1418759","article-title":"The Effect of Intensity, Light-Dark Ratio, and Age on the Flicker-Fusion Threshold","volume":"65","author":"Erlick","year":"1952","journal-title":"Am. J. Psychol"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","article-title":"Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses","volume":"41","author":"Faul","year":"2009","journal-title":"Behav. Res. Methods"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.3390\/vision7010026","article-title":"Peripheral flicker fusion at high luminance: Beyond the Ferry-Porter law","volume":"7","author":"Fernandez-Alonso","year":"2023","journal-title":"Vision (Basel)"},{"key":"B12","doi-asserted-by":"publisher","first-page":"192","DOI":"10.2475\/ajs.s3-44.261.192","article-title":"Persistence of vision","author":"Ferry","year":"1892","journal-title":"Am. J. Sci."},{"key":"B13","doi-asserted-by":"publisher","first-page":"100011","DOI":"10.1016\/j.aopr.2021.100011","article-title":"The clinical application of critical flicker fusion frequency in demyelinating optic neuritis","volume":"1","author":"Fu","year":"2021","journal-title":"Adv Ophthalmol. Pract. Res."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1126","DOI":"10.1055\/s-0043-124001","article-title":"Standards for ethics in sport and exercise science research: 2018 update","volume":"38","author":"Harriss","year":"2017","journal-title":"Int. J. Sports Med."},{"key":"B15","first-page":"138","article-title":"Functional comparison between critical flicker fusion frequency and simple cognitive tests in subjects breathing air or oxygen in normobaria","volume":"43","author":"Hemelryck","year":"2013","journal-title":"Diving Hyperb Med."},{"key":"B16","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1080\/001401397187720","article-title":"Basic study of the portable fatigue meter: effects of illumination, distance from eyes and age","volume":"40","author":"Hosokawa","year":"1997","journal-title":"Ergonomics"},{"key":"B17","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1038\/nn1879","article-title":"Human visual cortex responds to invisible chromatic flicker","volume":"10","author":"Jiang","year":"2007","journal-title":"Nat. Neurosci."},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1364\/josa.51.000422","article-title":"Visual responses to time-dependent stimuli; amplitude sensitivity measurements","volume":"51","author":"Kelly","year":"1961","journal-title":"J. Opt. Soc Am."},{"key":"B19","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1080\/13803395.2015.1007118","article-title":"Effect of oxygen on neuronal excitability measured by critical flicker fusion frequency is dose dependent","volume":"37","author":"Kot","year":"2015","journal-title":"J.\u00a0Clin. Exp. Neuropsychol."},{"key":"B20","first-page":"114","article-title":"Evaluation of critical flicker fusion frequency and perceived fatigue in divers after air and enriched air nitrox diving","volume":"40","author":"Lafere","year":"2010","journal-title":"Diving Hyperb Med."},{"key":"B21","doi-asserted-by":"publisher","first-page":"119","DOI":"10.28920\/dhm49.2.119-126","article-title":"Early detection of diving-related cognitive impairment of different nitrogen-oxygen gas mixtures using critical flicker fusion frequency","volume":"49","author":"Laf\u00e8re","year":"2019","journal-title":"Diving Hyperb Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.3390\/medicina57101096","article-title":"Critical flicker fusion frequency: a narrative review","volume":"57","author":"Mankowska","year":"2021","journal-title":"Med. (Kaunas)"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59040800","article-title":"Assessing critical flicker fusion frequency: Which confounders? A narrative review","volume":"59","author":"Muth","year":"2023","journal-title":"Medicina"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1002\/cphy.c140018","article-title":"Human physiology in an aquatic environment","volume":"5","author":"Pendergast","year":"2015","journal-title":"Compr. Physiol."},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.722915","article-title":"Assessment of alertness and cognitive performance of closed circuit rebreather divers with the critical flicker fusion frequency test in arctic diving conditions","volume":"12","author":"Piispanen","year":"2021","journal-title":"Front. Physiol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00421-018-4020-y","article-title":"Inert gas narcosis in scuba diving, different gases different reactions","volume":"119","author":"Rocco","year":"2019","journal-title":"Eur. J. Appl. Physiol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/0042-6989(88)90025-9","article-title":"Critical flicker frequency as a function of stimulus area and luminance at various eccentricities in human cone vision: a revision of granit-harper and ferry-porter laws","volume":"28","author":"Rovamo","year":"1988","journal-title":"Vision Res."},{"key":"B28","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1136\/bjsm.35.3.174","article-title":"Effect of immersion, submersion, and scuba diving on heart rate variability","volume":"35","author":"Schipke","year":"2001","journal-title":"Br. J. Sports Med."},{"key":"B29","doi-asserted-by":"crossref","DOI":"10.1002\/0471214426.pas0104","article-title":"Perception of visual motion","volume-title":"Steven\u2019s Handbook of Experimental Psychology","author":"Sekuler","year":"2002"},{"key":"B30","first-page":"142","article-title":"Effects of fatigue on critical flicker fusion and subjective sleepiness","volume":"47","author":"Shirane","year":"2005","journal-title":"J. Occup. Health"},{"key":"B31","first-page":"7477","article-title":"The effects of different states of arousal on the critical flicker fusion threshold","volume":"43","author":"Smith","year":"1976","journal-title":"Perceptual Motor Skills"},{"key":"B32","first-page":"82","article-title":"A comparison of simple reaction time, visual discrimination and critical flicker fusion frequency in professional divers at elevated pressure","volume":"46","author":"Tikkinen","year":"2016","journal-title":"Diving Hyperb Med."},{"key":"B33","doi-asserted-by":"publisher","first-page":"377","DOI":"10.28920\/dhm50.4.377-385","article-title":"Investigating critical flicker fusion frequency for monitoring gas narcosis in divers","volume":"50","author":"Vrijdag","year":"2020","journal-title":"Diving Hyperb Med."},{"key":"B34","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1001\/archopht.1964.00970020834020","article-title":"Relationship between critical flicker frequency and age in flicker perimetry","volume":"72","author":"Wolf","year":"1964","journal-title":"Arch. Ophthalmol."}],"container-title":["Frontiers in Physiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2026.1824031\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T05:21:18Z","timestamp":1788412878000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2026.1824031\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":34,"alternative-id":["10.3389\/fphys.2026.1824031"],"URL":"https:\/\/doi.org\/10.3389\/fphys.2026.1824031","relation":{},"ISSN":["1664-042X"],"issn-type":[{"value":"1664-042X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]},"article-number":"1824031"}}