{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T10:17:52Z","timestamp":1788517072983,"version":"build-2803163510"},"reference-count":42,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Physiol."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The sit-to-stand (STS) task is a fundamental functional movement requiring substantial lower-limb joint torque and coordinated neuromuscular control. The knee joint plays a dominant role in generating extensor torque during the body elevation phase. However, existing exoskeleton assistive strategies often lack alignment with the temporal characteristics of joint mechanical demand, limiting their effectiveness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Thirteen healthy male participants performed STS tasks under both non-assisted and exoskeleton-assisted conditions. A pressure-based motion intention recognition method was developed using anterior thigh pressure signals to detect movement onset. Three assistive torque levels (3.0 Nm, 4.5 Nm, and 6.0 Nm) were applied to the knee joint. Kinematic and kinetic data were collected using a motion capture system and force plates, and knee joint moment, power, and mechanical work were calculated to evaluate biomechanical changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Recognition-performance analysis showed that the pressure-threshold algorithm identified the target pre-extension trigger in all six validation recordings, corresponding to a positive-event detection rate of 100% (6\/6). The detected trigger occurred at 0.49 \u00b1 0.05 of the pressure-rising phase, and the onset of assistive torque occurred within 0.072 s of knee-extension onset, advancing torque output by approximately 0.228 s compared with a kinematics-only trigger. Because the validation trials included intentional STS attempts only, specificity and overall classification accuracy against non-intention events were not estimated in the present study. Knee joint moment exhibited a clear phase-dependent pattern, characterized by a rapid increase following seat-off and a peak during the body elevation phase. Compared with the control condition, exoskeleton assistance significantly reduced mean and peak knee joint moment under the 4.5 Nm and 6.0 Nm conditions (p &amp;lt; 0.0167). Joint power and total mechanical work were also significantly reduced across assisted conditions. These reductions were observed in healthy young male participants performing a standardized laboratory STS task.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In healthy young male participants under controlled laboratory conditions, knee joint mechanical demand during STS was strongly phase-dependent, and assistance aligned with this temporal structure reduced knee joint loading. The pressure-based intention recognition method provided a practical approach for improving system responsiveness during this standardized task. However, these findings should be interpreted as preliminary biomechanical evidence obtained from healthy participants, rather than direct evidence of clinical efficacy. Further studies involving older adults, patients with functional impairments, and real-world testing conditions are required before clinical or rehabilitation applications can be inferred.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fphys.2026.1859056","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T10:02:34Z","timestamp":1788516154000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A pressure-based motion intention recognition strategy for phase-specific knee exoskeleton assistance during sit-to-stand"],"prefix":"10.3389","volume":"17","author":[{"given":"Feng","family":"Feng","sequence":"first","affiliation":[{"name":"Department of Physical Education, Capital Normal University","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Yu","sequence":"additional","affiliation":[{"name":"Sport Biomechanics Center, Capital University of Physical Education and Sports","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kui","family":"Du","sequence":"additional","affiliation":[{"name":"Sport Biomechanics Center, Capital University of Physical Education and Sports","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zihao","family":"Li","sequence":"additional","affiliation":[{"name":"Sport Biomechanics Center, Capital University of Physical Education and Sports","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuai","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Physical Education, Capital Normal University","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2024.106360","article-title":"Relative muscular effort in the older adults during the sit-to-stand task: monitoring neuromuscular reserve and movement limitations","volume":"120","author":"Ahn","year":"2024","journal-title":"Clin. Biomech."},{"key":"B2","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.exger.2018.08.006","article-title":"The sit-to-stand muscle power test: an easy, inexpensive and portable procedure to assess muscle power in older people","volume":"112","author":"Alcazar","year":"2018","journal-title":"Exp. Gerontol."},{"key":"B3","article-title":"Influence of joint kinematics and joint moment on the design of an active exoskeleton to assist elderly with sit-to-stand movement","author":"Balasubramaniam","year":"2016"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1016\/j.isci.2023.107047","article-title":"Toward countering muscle and bone loss with spaceflight: GSK3 as a potential target","volume":"26","author":"Baranowski","year":"2023","journal-title":"iScience"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2022.111132","article-title":"Inter-joint coordination variability during a sit-to-stand fatiguing protocol","volume":"138","author":"Chen","year":"2022","journal-title":"J. Biomech."},{"key":"B6","first-page":"4879","article-title":"Effect of assistance timing in knee extensor muscle activation during sit-to-stand using a bilateral robotic knee exoskeleton","author":"Choi","year":"2021"},{"key":"B7","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1038\/nature14288","article-title":"Reducing the energy cost of human walking using an unpowered exoskeleton","volume":"522","author":"Collins","year":"2015","journal-title":"Nature"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1804","DOI":"10.1152\/jappl.2000.88.5.1804","article-title":"Age causes a redistribution of joint torques and powers during gait","volume":"88","author":"DeVita","year":"2000","journal-title":"J. Appl. Physiol."},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1109\/TCYB.2022.3224895","article-title":"Human-in-the-loop optimization of wearable robotic devices to improve human\u2013robot interaction: a systematic review","volume":"53","author":"D\u00edaz","year":"2023","journal-title":"IEEE Trans. Cybern."},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.aar5438","article-title":"Human-in-the-loop optimization of hip assistance with a soft exosuit during walking","volume":"3","author":"Ding","year":"2018","journal-title":"Sci. Robot."},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-017-0235-0","article-title":"Reducing the metabolic cost of walking with an ankle exoskeleton: interaction between actuation timing and power","volume":"14","author":"Galle","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"key":"B12","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.gaitpost.2007.10.003","article-title":"Quantitative analysis of sit to stand movement: experimental set-up definition and application to healthy and hemiplegic adults","volume":"28","author":"Galli","year":"2008","journal-title":"Gait Posture"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1016\/s1388-2457(99)00109-1","article-title":"Patterned electromyographic activity in the sit-to-stand movement","volume":"110","author":"Goulart","year":"1999","journal-title":"Clin. Neurophysiol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1038\/s44172-025-00440-3","article-title":"Powered knee exoskeleton improves sit-to-stand transitions in stroke patients using electromyographic control","volume":"4","author":"Gunnell","year":"2025","journal-title":"Commun. Eng."},{"key":"B15","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.jelekin.2017.08.004","article-title":"Muscle synergies underlying sit-to-stand tasks in elderly people and their relationship with kinetic characteristics","volume":"37","author":"Hanawa","year":"2017","journal-title":"J. Electromyogr. Kinesiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1186\/s13102-023-00716-1","article-title":"Analysis of inter-joint coordination during the sit-to-stand and stand-to-sit tasks in stroke patients with hemiplegia","volume":"15","author":"He","year":"2023","journal-title":"BMC Sports Sci. Med. Rehabil."},{"key":"B17","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1093\/geront\/34.1.16","article-title":"Preventing falls among community-dwelling older persons: results from a randomized trial","volume":"34","author":"Hornbrook","year":"1994","journal-title":"Gerontologist"},{"key":"B18","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.clinbiomech.2004.08.004","article-title":"Altered hamstring-quadriceps muscle balance in patients with knee osteoarthritis","volume":"20","author":"Hortob\u00e1gyi","year":"2005","journal-title":"Clin. Biomech."},{"key":"B19","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1093\/ptj\/82.9.866","article-title":"Determinants of the sit-to-stand movement: a review","volume":"82","author":"Janssen","year":"2002","journal-title":"Phys. Ther."},{"key":"B20","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.jbiomech.2009.09.030","article-title":"Invariant ankle moment patterns when walking with and without a robotic ankle exoskeleton","volume":"43","author":"Kao","year":"2010","journal-title":"J. Biomech."},{"key":"B21","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/S0268-0033(96)00077-0","article-title":"Analysis of the sit-stand-sit movement cycle in normal subjects","volume":"12","author":"Kerr","year":"1997","journal-title":"Clin. Biomech."},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.3389\/fnbot.2024.1348029","article-title":"Can lower-limb exoskeletons support sit-to-stand motions in frail elderly without crutches? A study combining optimal control and motion capture","volume":"18","author":"Lau","year":"2024","journal-title":"Front. Neurorob."},{"key":"B23","doi-asserted-by":"publisher","first-page":"2180","DOI":"10.1109\/TBME.2012.2198821","article-title":"Intention-based EMG control for powered exoskeletons","volume":"59","author":"Lenzi","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.1016\/j.arrct.2022.100181","article-title":"Comparison of the lower extremity kinematics and center of mass variations in sit-to-stand and stand-to-sit movements of older fallers and nonfallers","volume":"4","author":"Lin","year":"2022","journal-title":"Arch. Rehabil. Res. Clin. Translation"},{"key":"B25","first-page":"767","article-title":"Calculation method for human joint angles in 3D photogrammetry","author":"Liu","year":"2004","journal-title":"J. Beijing Sport Univ."},{"key":"B26","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1109\/mcs.2018.2866605","article-title":"On the design and control of highly backdrivable lower-limb exoskeletons","volume":"38","author":"Lv","year":"2018","journal-title":"IEEE Control Syst. Mag."},{"key":"B27","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.gaitpost.2009.04.002","article-title":"Muscles limiting the sit-to-stand movement: an experimental simulation of muscle weakness","volume":"30","author":"Van der Heijden","year":"2009","journal-title":"Gait Posture"},{"key":"B28","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s43154-020-00015-4","article-title":"Human-robot interaction in rehabilitation and assistance: a review","volume":"1","author":"Mohebbi","year":"2020","journal-title":"Curr. Rob. Rep."},{"key":"B29","first-page":"3065","article-title":"Autonomous exoskeleton reduces metabolic cost of walking","author":"Mooney","year":"2014"},{"key":"B30","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1093\/ageing\/27.2.137","article-title":"A kinematic comparison between elderly and young subjects standing up from and sitting down in a chair","volume":"27","author":"Mourey","year":"1998","journal-title":"Age Ageing"},{"key":"B31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2020.110046","article-title":"Comprehensive description of sit-to-stand motions using force and angle data","volume":"112","author":"Norman-Gerum","year":"2020","journal-title":"J. Biomech."},{"key":"B32","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1249\/00005768-199006000-00015","article-title":"Control of body mass transfer as a function of speed of ascent in sit-to-stand","volume":"22","author":"Pai","year":"1990","journal-title":"Med. Sci. Sports Exercise"},{"key":"B33","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1016\/s0021-9290(00)00046-4","article-title":"Sit-to-stand motor strategies investigated in able-bodied young and elderly subjects","volume":"33","author":"Papa","year":"2000","journal-title":"J. Biomech."},{"key":"B34","doi-asserted-by":"publisher","first-page":"4202","DOI":"10.3390\/s19194202","article-title":"Fatigue detection during sit-to-stand test based on surface electromyography and acceleration: a case study","volume":"19","author":"Rold\u00e1n Jim\u00e9nez","year":"2019","journal-title":"Sensors"},{"key":"B35","first-page":"1","article-title":"Knee exoskeleton reduces muscle effort and improves balance during sit-to-stand transitions after stroke: a case study","author":"Sarkisian","year":"2022"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1402","DOI":"10.1242\/jeb.009241","article-title":"Mechanics and energetics of level walking with powered ankle exoskeletons","volume":"211","author":"Sawicki","year":"2008","journal-title":"J. Exp. Biol."},{"key":"B37","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1093\/ptj\/70.10.638","article-title":"Whole-body movements during rising to standing from sitting","volume":"70","author":"Schenkman","year":"1990","journal-title":"Phys. Ther."},{"key":"B38","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1109\/tmech.2017.2704521","article-title":"Design and validation of a torque-controllable knee exoskeleton for sit-to-stand assistance","volume":"22","author":"Shepherd","year":"2017","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"B39","doi-asserted-by":"publisher","first-page":"1998","DOI":"10.1097\/01.brs.0000176195.16128.27","article-title":"Effect of low back pain on the kinematics and joint coordination of the lumbar spine and hip during sit-to-stand and stand-to-sit","volume":"30","author":"Shum","year":"2005","journal-title":"Spine"},{"key":"B40","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925X-6-26","article-title":"Computation of the kinematics and the minimum peak joint moments of sit-to-stand movements","volume":"6","author":"Yoshioka","year":"2007","journal-title":"Biomed. Eng. Online"},{"key":"B41","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925X-13-27","article-title":"Peak hip and knee joint moments during a sit-to-stand movement are invariant to the change of seat height within the range of low to normal seat height","volume":"13","author":"Yoshioka","year":"2014","journal-title":"Biomed. Eng. Online"},{"key":"B42","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1126\/science.aal5054","article-title":"Human-in-the-loop optimization of exoskeleton assistance during walking","volume":"356","author":"Zhang","year":"2017","journal-title":"Science"}],"container-title":["Frontiers in Physiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2026.1859056\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T10:02:36Z","timestamp":1788516156000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fphys.2026.1859056\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":42,"alternative-id":["10.3389\/fphys.2026.1859056"],"URL":"https:\/\/doi.org\/10.3389\/fphys.2026.1859056","relation":{},"ISSN":["1664-042X"],"issn-type":[{"value":"1664-042X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"article-number":"1859056"}}