{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T05:12:53Z","timestamp":1784265173691,"version":"3.55.0"},"reference-count":43,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T00:00:00Z","timestamp":1759795200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Public Health"],"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>The technology employed in magnetic resonance imaging (MRI) systems has evolved continuously, resulting in MRI scanners with stronger static magnetic fields (SMF) B0, faster and stronger gradient magnetic fields, and more powerful radiofrequency transmission coils. The most well-known hazard associated with an MRI environment is the projectile effect due to Spatial Field Gradient (SFG). Furthermore, movement through the SFG generates a time-varying magnetic field, which in turn induces a voltage in body tissues. This has the potential to result in a range of physiological symptoms, including headache, nausea, vertigo, phosphenes, numbness, tingling, loss of proprioception, and balance disturbances.<\/jats:p><\/jats:sec><jats:sec><jats:title>Approach<\/jats:title><jats:p>The methodology outlined in this study provides a comprehensive and reliable approach to creating a 3D map of the SMF (fringe field) around a clinical MRI facility. The methodology involves measuring the unperturbed B field, including magnitude and axial components, in specific points and subsequently performing a mathematical procedure involving fitting and interpolation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Main results<\/jats:title><jats:p>Fringe field magnitude and axial components 3D maps are presented for a 3T whole-body MRI scanner for clinical application located in a hospital facility.<\/jats:p><\/jats:sec><jats:sec><jats:title>Significance<\/jats:title><jats:p>The map obtained could be used for a number of purposes, including the evaluation of hazard. This could be achieved by using digital tools to create a simulation of all types of MRI workers movements within the facility. The map could also be used for the training and education of MRI operators, with a view to establishing best practices. The estimation of magnetic field axial components represents a valuable enhancement, as these data can be used to calculate induced electric fields during rotational movements, such as those of the head or torso.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fpubh.2025.1625728","type":"journal-article","created":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T15:27:28Z","timestamp":1759850848000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["3D mapping of static magnetic field magnitude and axial-components around a total body 3T MRI clinical scanner"],"prefix":"10.3389","volume":"13","author":[{"given":"Francesco","family":"Girardello","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Antonietta","family":"D\u2019Avanzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimo","family":"Mattozzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victorian Michele","family":"Ferro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Acri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valentina","family":"Hartwig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,10,7]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1002\/jmri.26880","article-title":"ACR guidance document on MR safe practices: updates and critical information 2019","volume":"51","author":"Greenberg","year":"2020","journal-title":"J Magn Reson Imaging"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1002\/jmri.27319","article-title":"7T MR safety","volume":"53","author":"Fagan","year":"2021","journal-title":"J Magn Reson Imaging"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1007\/s11517-017-1779-7","article-title":"Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches","volume":"56","author":"Hartwig","year":"2018","journal-title":"Med Biol Eng Comput"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/s11517-021-02435-6","article-title":"Occupational exposure to electromagnetic fields in magnetic resonance environment: an update on regulation, exposure assessment techniques, health risk evaluation, and surveillance","volume":"60","author":"Hartwig","year":"2022","journal-title":"Med Biol Eng Comput"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.ejrad.2017.01.010","article-title":"Safety issues and updates under MR environments","volume":"89","author":"Kim","year":"2017","journal-title":"Eur J Radiol"},{"key":"ref6","doi-asserted-by":"crossref","DOI":"10.1017\/9781107706958","volume-title":"MRI from picture to proton","author":"McRobbie","year":"2017"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/environments6110119","article-title":"Workers with active implantable medical devices exposed to emf: in vitro test for the risk assessment","volume":"6","author":"Mattei","year":"2019","journal-title":"Environments"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.1002\/mrm.30153","article-title":"Transitioning from 0.5 to 0.9 mT: protecting against inadvertent activation of magnet mode in active implants","volume":"92","author":"Steckner","year":"2024","journal-title":"Magn Reson Med"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"795","DOI":"10.13075\/ijomeh.1896.00783","article-title":"Evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of exposure to electromagnetic fields\u2014practical approach to the requirements of European directive 2013\/35\/EU","volume":"31","author":"Zradzi\u0144ski","year":"2018","journal-title":"Int J Occup Med Environ Health"},{"key":"ref10","doi-asserted-by":"crossref","DOI":"10.1002\/9781394322169","volume-title":"Essentials of MRI safety","author":"McRobbie","year":"2020"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s00261-016-0680-4","article-title":"Magnetic resonance safety","volume":"41","author":"Simmons","year":"2016","journal-title":"Abdom Radiol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1097\/HP.0b013e31829e5580","article-title":"Guidelines for limiting exposure to electric fields induced by and by time-varying magnetic fields below 1 Hz","volume":"106","year":"2014","journal-title":"Health Phys"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1055\/a-2296-3860","article-title":"Health risks for medical personnel due to magnetic fields in magnetic resonance imaging","volume":"197","author":"K\u00f6nig","year":"2024","journal-title":"R\u00f6Fo"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fpubh.2021.699675","article-title":"Subjective symptoms in magnetic resonance imaging personnel: a multi-center study in Italy","volume":"9","author":"Bravo","year":"2021","journal-title":"Front Public Health"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"2718","DOI":"10.1007\/s00330-015-3629-z","article-title":"Transient health symptoms of MRI staff working with 1.5 and 3.0 tesla scanners in the UK","volume":"25","author":"De Vocht","year":"2015","journal-title":"Eur Radiol"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1002\/jmri.20510","article-title":"Acute neurobehavioral effects of exposure to static magnetic fields? Analyses of exposure-response relations","volume":"23","author":"De Vocht","year":"2006","journal-title":"J Magn Reson Imaging"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1080\/15368378.2022.2031212","article-title":"Subjective symptoms of SMFs and RF energy, and risk perception among staff working with MR scanners within two public hospitals in South Africa","volume":"41","author":"Rathebe","year":"2022","journal-title":"Electromagn Biol Med"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"2141","DOI":"10.1002\/mrm.25720","article-title":"Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners","volume":"75","author":"Schaap","year":"2016","journal-title":"Magn Reson Med"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1002\/mrm.25443","article-title":"Simultaneous exposure to MRI-related static and magnetic fields affects neurocognitive performance: a double-blind randomized crossover study","volume":"849","author":"van Nierop","year":"2015","journal-title":"Magn Reson Med"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1016\/j.envres.2018.03.008","article-title":"Development of hypertension after long-term exposure to static magnetic fields among workers from a magnetic resonance imaging device manufacturing facility","volume":"164","author":"Bongers","year":"2018","journal-title":"Environ Res"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"113636","DOI":"10.1016\/j.ijheh.2020.113636","article-title":"Occupational exposure to MRI-related magnetic stray fields and sleep quality among MRI\u2014technicians\u2014a cross-sectional study in the Netherlands","volume":"231","author":"Huss","year":"2021","journal-title":"Int J Hyg Environ Health"},{"key":"ref22","article-title":"Directive 2013\/35\/EC on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields)","year":"2013","journal-title":"Off J Eur Union"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1097\/HP.0b013e3181aff9db","article-title":"Statement on the \u201cguidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)\u201d","volume":"97","year":"2009","journal-title":"Health Phys"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1097\/HP.0b013e3181f06c86","article-title":"Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz)","volume":"99","year":"2010","journal-title":"Health Phys"},{"key":"ref25","volume-title":"Potential health effects of exposure to electromagnetic fields (EMF). Luxembourg: European Commission, Directorate-General for Health and Food Safety.","year":"2015"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.measurement.2011.03.001","article-title":"Experimental investigation on workers\u2019 exposure to electromagnetic fields in proximity of magnetic resonance imaging systems","volume":"45","author":"Betta","year":"2012","journal-title":"Measurement"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1007\/s10669-007-9064-1","article-title":"Occupational risk from static magnetic fields of MRI scanners","volume":"27","author":"Karpowicz","year":"2007","journal-title":"Environmetalist"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"5988","DOI":"10.1002\/mp.12537","article-title":"Occupational exposure in MR facilities due to movements in the static magnetic field","volume":"44","author":"Andreuccetti","year":"2017","journal-title":"Med Phys"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.ejmp.2018.11.004","article-title":"Moving across the static magnetic field of a 1.5 T MRI scanner: analysing compliance with directive 2013\/35\/EU","volume":"57","author":"Gurrera","year":"2019","journal-title":"Phys Med"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1080\/10803548.2020.1738114","article-title":"Analysis, comparison and representation of occupational exposure to a static magnetic field in a 3-T MRI site","volume":"28","author":"Hartwig","year":"2022","journal-title":"Int J Occup Saf Ergon"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/ijerph15071298","article-title":"dB\/dt evaluation in MRI sites: is ICNIRP threshold limit (for workers) exceeded?","volume":"15","author":"Acri","year":"2018","journal-title":"Int J Environ Res Public Health"},{"key":"ref32","first-page":"741","article-title":"Personal time-varying magnetic fields evaluation during activities in MRI sites","author":"Acri","year":"2015"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1002\/bem.22145","article-title":"Evaluation of occupational exposure to static magnetic field in MRI sites based on body pose estimation and SMF analytical computation","volume":"39","author":"Belguerras","year":"2018","journal-title":"Bioelectromagnetics"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"344","DOI":"10.3389\/fpubh.2017.00344","article-title":"Exposure assessment and biomonitoring of workers in magnetic resonance environment: an exploratory study","volume":"5","author":"Sannino","year":"2017","journal-title":"Front Public Health"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1002\/cmr.b.21270","article-title":"Estimation of occupational exposure to static magnetic fields due to usual movements in magnetic resonance units","volume":"44","author":"Hartwig","year":"2014","journal-title":"Concepts Magn Reson Part B: Magn Reson Eng"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1007\/s10334-011-0279-2","article-title":"A novel tool for estimation of magnetic resonance occupational exposure to spatially varying magnetic fields","volume":"24","author":"Hartwig","year":"2011","journal-title":"MAGMA"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"613616","DOI":"10.3389\/fbioe.2021.613616","article-title":"Experimental and modeling analyses of human motion across the static magnetic field of an MRI scanner","volume":"9","author":"Gurrera","year":"2021","journal-title":"Front Bioeng Biotechnol"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"11492","DOI":"10.1109\/ACCESS.2024.3355191","article-title":"Assessment of exposure to spatially varying magnetic fields in MRI environments: modeling analysis for simulation tools","volume":"12","author":"Hartwig","year":"2024","journal-title":"IEEE Access"},{"key":"ref39","volume-title":"The concise encyclopedia of statistics","author":"Dodge","year":"2008"},{"key":"ref40","article-title":"An investigation into occupational exposure to electromagnetic fields for personnel working with and around medical magnetic resonance imaging equipment.","author":"Capstick","year":"2008"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1080\/10803548.2006.11076679","article-title":"Health risk assessment of occupational exposure to a magnetic field from magnetic resonance imaging devices","volume":"12","author":"Karpowicz","year":"2006","journal-title":"Int J Occup Saf Ergon"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1080\/10803548.2009.11076785","article-title":"Exposure of workers to electromagnetic fields. A review of open questions on exposure assessment techniques","volume":"15","author":"Mild","year":"2009","journal-title":"Int J Occup Saf Ergon"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"4739","DOI":"10.1088\/0031-9155\/57\/15\/4739","article-title":"Calculation of the electric field resulting from human body rotation in a magnetic field","volume":"57","author":"Cobos S\u00e1nchez","year":"2012","journal-title":"Phys Med Biol"}],"container-title":["Frontiers in Public Health"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fpubh.2025.1625728\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T15:27:37Z","timestamp":1759850857000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fpubh.2025.1625728\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,7]]},"references-count":43,"alternative-id":["10.3389\/fpubh.2025.1625728"],"URL":"https:\/\/doi.org\/10.3389\/fpubh.2025.1625728","relation":{},"ISSN":["2296-2565"],"issn-type":[{"value":"2296-2565","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,7]]},"article-number":"1625728"}}