{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T06:22:13Z","timestamp":1787638933602,"version":"build-2736575974"},"reference-count":21,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:00:00Z","timestamp":1787616000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Public Health"],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Airborne transmission remains a challenge for infection prevention and control in healthcare environments, motivating compact air-disinfection technologies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A compact 266 nm multi-reflection laser-curtain module was developed, providing two effective curtain widths (96 mm and 200 mm). Aerosolised Staphylococcus albus (S. albus; a coagulase-negative staphylococcal bacterial surrogate) was tested in (i) a mixed-air 20 m\n                      <jats:sup>3<\/jats:sup>\n                      enclosure for time-dependent inactivation and (ii) a duct-flow single-pass rig using three curtains in series with paired upstream-downstream sampling. Matched no-UV controls were used for baseline correction, with first-order kinetics used for room-scale analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In the 20 m\n                      <jats:sup>3<\/jats:sup>\n                      enclosure, inactivation increased with operating time. The 96 mm curtain achieved ~66\u201369% at 5 min and exceeded 98% by 30 min, approaching \u226599.9% with extended operation. The 200 mm curtain exceeded 99.5% by 20 min and approached \u226599.99% at longer times, with a numerically higher apparent rate constant (0.190 vs. 0.127 min\n                      <jats:sup>\u22121<\/jats:sup>\n                      ). In the duct-flow system, three curtains maintained \u226599.0% single-pass inactivation across 1.2\u20139.6 m\/s.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The multi-reflection 266 nm laser-curtain achieved high inactivation in controlled room-scale and duct single-pass tests, supporting further engineering evaluation of this air-disinfection concept rather than immediate healthcare deployment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fpubh.2026.1809909","type":"journal-article","created":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T05:35:25Z","timestamp":1787636125000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A 266-nm multi-reflection laser curtain for airborne bacterial inactivation in a 20-m3 chamber and a single-pass duct testbed"],"prefix":"10.3389","volume":"14","author":[{"given":"Chenjie","family":"Guo","sequence":"first","affiliation":[{"name":"Department of Medical Equipment Management, Shanghai Pudong New Area Hospital of Traditional Chinese Medicine, Pudong New Area","place":["Shanghai, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,25]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.ajic.2007.07.012","article-title":"The ventilation of multiple-bed hospital wards: review and analysis","volume":"36","author":"Beggs","year":"2008","journal-title":"Am J Infect Control."},{"key":"B2","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1177\/003335491012500105","article-title":"The history of ultraviolet germicidal irradiation for air disinfection","volume":"125","author":"Reed","year":"2010","journal-title":"Public Health Rep."},{"key":"B3","doi-asserted-by":"publisher","first-page":"S13","DOI":"10.1016\/j.ajic.2010.04.208","article-title":"Applications of ultraviolet germicidal irradiation disinfection in health care facilities: effective adjunct, but not stand-alone technology","volume":"38","author":"Memarzadeh","year":"2010","journal-title":"Am J Infect Control"},{"key":"B4","doi-asserted-by":"publisher","first-page":"e1000043","DOI":"10.1371\/journal.pmed.1000043","article-title":"Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission","volume":"6","author":"Escombe","year":"2009","journal-title":"PLoS Med."},{"key":"B5","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1001\/jama.2020.7603","article-title":"Airborne spread of SARS-CoV-2 and a potential role for air disinfection","volume":"324","author":"Nardell","year":"2020","journal-title":"JAMA."},{"key":"B6","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.jhin.2020.12.022","article-title":"Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus (SARS-CoV-2)","volume":"110","author":"Tang","year":"2021","journal-title":"J Hosp Infect."},{"key":"B7","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.jhin.2022.12.009","article-title":"Shedding a light on ultraviolet-C technologies in the hospital environment","volume":"132","author":"Demeersseman","year":"2023","journal-title":"J Hosp Infect."},{"key":"B8","doi-asserted-by":"publisher","first-page":"107852","DOI":"10.1016\/j.buildenv.2021.107852","article-title":"Ultraviolet germicidal irradiation (UVGI) for in-duct airborne bioaerosol disinfection: review and analysis of design factors","volume":"197","author":"Luo","year":"2021","journal-title":"Build Environ."},{"key":"B9","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1177\/003335490812300108","article-title":"Safety of upper-room ultraviolet germicidal air disinfection for room occupants: results from the Tuberculosis Ultraviolet Shelter Study","volume":"123","author":"Nardell","year":"2008","journal-title":"Public Health Rep."},{"key":"B10","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1080\/15459620701271693","article-title":"Fundamental factors affecting upper-room ultraviolet germicidal irradiation\u2014Part I","volume":"4","author":"First","year":"2007","journal-title":"Experimental J Occup Environ Hyg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"419","DOI":"10.3390\/pathogens12030419","article-title":"UVC-based air disinfection systems for rapid inactivation of SARS-CoV-2 present in the air","volume":"12","author":"Garg","year":"2023","journal-title":"Pathogens."},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1177\/09544089241242616","article-title":"Design and optical simulation of heating, ventilation, and air conditioning duct incorporating ultraviolet-C channels based on Bunimovich stadium","author":"Kumar","year":"2024","journal-title":"Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering."},{"key":"B13","doi-asserted-by":"publisher","first-page":"6652","DOI":"10.1364\/AO.498255","article-title":"Modeling a UVC irradiation standalone system for inactivating Mycobacterium tuberculosis from indoor spaces","volume":"62","author":"Kumar","year":"2023","journal-title":"Appl Opt."},{"key":"B14","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1140\/epjp\/s13360-021-02240-y","article-title":"Effectiveness of a UVC air disinfection system for the HVAC of an ICU","volume":"137","author":"de Souza","year":"2022","journal-title":"Eur Physic J Plus."},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.2139\/ssrn.5397727","article-title":"Quantitative evaluation of UVC disinfection efficiency in air duct: effects of relative humidity and lamp arrangement on bioaerosol inactivation","author":"He","year":"2026","journal-title":"Environ Technol Innov."},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jobe.2026.115719","article-title":"Synergistic effects of ceiling fan coupling with upper-room UVGI on the bioaerosol dispersion and inactivation efficacy in an isolation ward","author":"Huang","year":"2026","journal-title":"J Build Eng."},{"key":"B17","volume-title":"Radiation in Disinfection and Infection Management: Established Practices and Emerging Applications","author":"Santos","year":"2026"},{"key":"B18","doi-asserted-by":"publisher","first-page":"10285","DOI":"10.1038\/s41598-020-67211-2","article-title":"Far-UVC (222 nm) efficiently and safely inactivates airborne human coronaviruses","volume":"10","author":"Buonanno","year":"2020","journal-title":"Sci Rep."},{"key":"B19","doi-asserted-by":"publisher","first-page":"2752","DOI":"10.1038\/s41598-018-21058-w","article-title":"Far-UVC light: A new tool to control the spread of airborne-mediated microbial diseases","volume":"8","author":"Welch","year":"2018","journal-title":"Sci Rep."},{"key":"B20","doi-asserted-by":"publisher","first-page":"4373","DOI":"10.1038\/s41598-022-08462-z","article-title":"Far-UVC (222 nm) efficiently inactivates an airborne pathogen in a room-sized chamber","volume":"12","author":"Eadie","year":"2022","journal-title":"Sci Rep."},{"key":"B21","doi-asserted-by":"publisher","first-page":"19930","DOI":"10.1038\/s41598-021-99204-0","article-title":"Improved estimates of 222 nm far-UVC susceptibility for aerosolized human coronavirus via a validated high-fidelity coupled radiation-CFD code","volume":"11","author":"Buchan","year":"2021","journal-title":"Sci Rep."}],"container-title":["Frontiers in Public Health"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fpubh.2026.1809909\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T05:35:26Z","timestamp":1787636126000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fpubh.2026.1809909\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,25]]},"references-count":21,"alternative-id":["10.3389\/fpubh.2026.1809909"],"URL":"https:\/\/doi.org\/10.3389\/fpubh.2026.1809909","relation":{},"ISSN":["2296-2565"],"issn-type":[{"value":"2296-2565","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,25]]},"article-number":"1809909"}}