{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T11:14:04Z","timestamp":1788261244296,"version":"build-2803163510"},"reference-count":29,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Radiol."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the clinical utility of a wide-detector CT protocol with variable helical pitch (vHP) for one-stop cardiovascular and cerebrovascular CT angiography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective randomized study enrolled 61 patients (25 in the Group A and 36 in the Group B) with suspected cardiovascular and cerebrovascular diseases. Group A underwent the integrated one-stop CTA protocol (which incorporates vHP technology), whereas Group B underwent conventional separate scans (coronary CTA and head-neck CTA). Both groups used automated bolus-tracking triggering. Comparisons included effective scanning time, total operating time, contrast medium volume, radiation dose (dose-length product, DLP), and subjective and objective image quality. Normality was assessed using the Shapiro\u2013Wilk test; continuous variables were compared using independent samples t-test or Mann\u2013Whitney U test as appropriate. The false discovery rate method was applied to correct for multiple comparisons, and analysis of covariance was performed to adjust for potential confounders.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The integrated protocol group (Group A) demonstrated significantly higher contrast-to-noise ratio (CNR) in the coronary arteries and major aortic branches(all FDR-corrected\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001). In the neck region, Group A showed significantly higher SNR in the common carotid arteries (FDR-corrected\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001 for RCCA and\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.0044 for LCCA), whereas Group B demonstrated better CNR in the right internal carotid artery (FDR-corrected\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001) and lower image noise in several vessels (FDR-corrected\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05 for RICA SD and LVA SD). Notably, ANCOVA models for SNR exhibited poor fit with adjusted R\n                      <jats:sup>2<\/jats:sup>\n                      values frequently near zero or negative, warranting cautious interpretation; the primary evidence for protocol-related image quality improvement is therefore based on the robust CNR findings. ANCOVA confirmed that these intergroup differences remained significant after adjustment (all adjusted\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.05 for key CNR\/SNR comparisons), indicating protocol-related rather than baseline-driven advantages. Subjective image quality was excellent in both groups (median 4, IQR 4\u20134), with no significant intergroup differences. DLP was higher in Group A (909.00 vs. 694.50 mGy\u00b7cm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001), but effective scanning time was significantly shorter (8.00 vs. 19.00 s, 57.9% reduction,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001), and total operating time was markedly reduced (480.00 vs. 1020.00 s, 52.9% reduction,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001). Contrast medium volume was halved in Group A (50\u201360 vs. 100\u2013120 mL).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The integrated wide-detector CT protocol evaluated in this study (which incorporates variable helical pitch as a key enabling component) is technically feasible and offers workflow advantages over conventional scanning, including shorter scan time, reduced contrast volume, and maintained image quality, with a somewhat higher radiation dose. However, lacking an independent reference standard, its diagnostic accuracy for detecting significant stenosis remains unproven. Further validation with invasive angiography is needed before routine clinical use. However, because the integrated protocol differs from the conventional protocol in multiple parameters simultaneously (detector configuration, rotation speed, pitch, and trigger threshold), the individual contribution of variable helical pitch cannot be isolated from these combined hardware and protocol differences.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fradi.2026.1887780","type":"journal-article","created":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T10:18:06Z","timestamp":1788257886000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A wide-detector CT protocol for one-stop cardio-cerebrovascular angiography: a technical feasibility study comparing an integrated protocol with conventional two-scan approach"],"prefix":"10.3389","volume":"6","author":[{"given":"Jie","family":"Yan","sequence":"first","affiliation":[{"name":"Department of Radiology, Gejiu People\u2019s Hospital","place":["Gejiu, Yunnan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feiyan","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gejiu People\u2019s Hospital","place":["Gejiu, Yunnan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuixian","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gejiu People\u2019s Hospital","place":["Gejiu, Yunnan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunhui","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gejiu People\u2019s Hospital","place":["Gejiu, Yunnan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Long","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gejiu People\u2019s Hospital","place":["Gejiu, Yunnan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Ge","sequence":"additional","affiliation":[{"name":"Canon Medical Systems (CHINA) Co., LTD","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"He","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gejiu People\u2019s Hospital","place":["Gejiu, Yunnan, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"2361","DOI":"10.1016\/j.jacc.2022.11.005","article-title":"The global burden of cardiovascular diseases and risk: a compass for future health","volume":"80","author":"Vaduganathan","year":"2022","journal-title":"JACC"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1307927","DOI":"10.3389\/fpubh.2024.1307927","article-title":"Influence of loneliness burden on cardio-cerebral vascular disease among the Chinese older adult: a national cohort study","volume":"12","author":"Wu","year":"2024","journal-title":"Front Public Health"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1830","DOI":"10.1016\/j.scib.2022.08.013","article-title":"From cerebrovascular diseases to neuro-co-cardiological diseases: a challenge in the new epoch","volume":"67","author":"Liu","year":"2022","journal-title":"Sci Bull (Beijing)"},{"key":"B4","doi-asserted-by":"publisher","first-page":"e031237","DOI":"10.1161\/JAHA.123.031237","article-title":"Advancing cardiovascular health equity globally through digital technologies","volume":"13","author":"Ogungbe","year":"2024","journal-title":"J Am Heart Assoc"},{"key":"B5","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1177\/23969873241231702","article-title":"Asymptomatic coronary artery disease in ischaemic stroke survivors: a systematic review and meta-analysis","volume":"9","author":"Muthalaly","year":"2024","journal-title":"Eur Stroke J"},{"key":"B6","doi-asserted-by":"publisher","first-page":"120492","DOI":"10.1016\/j.jns.2022.120492","article-title":"Prevalence of carotid artery stenosis with coronary artery disease in Japanese patients: a single-center study","volume":"443","author":"Suzuki","year":"2022","journal-title":"J Neurol Sci"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1161\/STROKEAHA.121.037316","article-title":"Stroke-heart syndrome: incidence and clinical outcomes of cardiac complications following stroke","volume":"53","author":"Buckley","year":"2022","journal-title":"Stroke"},{"key":"B8","doi-asserted-by":"publisher","first-page":"e0264390","DOI":"10.1371\/journal.pone.0264390","article-title":"Associations among cardiovascular and cerebrovascular diseases: analysis of the nationwide claims-based JROAD-DpC dataset","volume":"17","author":"Nakai","year":"2022","journal-title":"PLoS One"},{"key":"B9","doi-asserted-by":"publisher","first-page":"4167","DOI":"10.3892\/etm.2019.7420","article-title":"Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: a feasibility study","volume":"17","author":"Zhao","year":"2019","journal-title":"Exp Ther Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2007.10.003","article-title":"The 2007 recommendations of the international commission on radiological protection. ICRP publication 103","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"B11","doi-asserted-by":"publisher","first-page":"404","DOI":"10.3390\/jcdd10090404","article-title":"Evaluation of image quality for high heart rates for coronary computed tomographic angiography with advancement in CT technology: the CONVERGE registry","volume":"10","author":"Abdelkarim","year":"2023","journal-title":"J Cardiovasc Dev Dis"},{"key":"B12","doi-asserted-by":"publisher","first-page":"e30583","DOI":"10.1097\/MD.0000000000030583","article-title":"Radiation dose and image quality of CT coronary angiography in patients with high heart rate or irregular heart rhythm using a 16-cm wide detector CT scanner","volume":"101","author":"Ondrejkovic","year":"2022","journal-title":"Medicine (Baltimore)"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1730","DOI":"10.3390\/tomography10110127","article-title":"A review of factors affecting radiation dose and image quality in coronary CTA performed with wide-detector CT","volume":"10","author":"Fan","year":"2024","journal-title":"Tomography"},{"key":"B14","doi-asserted-by":"publisher","first-page":"e187","DOI":"10.1016\/j.jacc.2021.07.053","article-title":"2021 AHA\/ACC\/ASE\/CHEST\/SAEM\/SCCT\/SCMR guideline for the evaluation and diagnosis of chest pain: a report of the American College of Cardiology\/American Heart Association joint committee on clinical practice guidelines","volume":"78","author":"Gulati","year":"2021","journal-title":"J Am Coll Cardiol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jcct.2022.09.003","article-title":"2022 Use of coronary computed tomographic angiography for patients presenting with acute chest pain to the emergency department: an expert consensus document of the society of cardiovascular computed tomography (SCCT): endorsed by the American college of radiology (ACR) and north American society for cardiovascular imaging (NASCI)","volume":"17","author":"Maroules","year":"2023","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"B16","doi-asserted-by":"publisher","first-page":"7034","DOI":"10.1007\/s00330-023-09528-w","article-title":"One-stop combined CT angiography of coronary and craniocervical arteries: recommended as the first examination for patients suspected of coronary or craniocervical artery disease","volume":"33","author":"Guo","year":"2023","journal-title":"Eur Radiol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"3808","DOI":"10.1007\/s00330-021-08505-5","article-title":"Clinical effectiveness of contrast medium injection protocols for 80-kV coronary and craniocervical CT angiography-a prospective multicenter observational study","volume":"32","author":"Wang","year":"2022","journal-title":"Eur Radiol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1186\/s12872-023-03343-3","article-title":"One-step integrated coronary-carotid-cerebral computed tomography angiography to evaluate cardiovascular and cerebrovascular atherosclerosis","volume":"23","author":"Liu","year":"2023","journal-title":"BMC Cardiovasc Disord"},{"key":"B19","doi-asserted-by":"publisher","first-page":"9545","DOI":"10.21037\/qims-2024-2579","article-title":"The application value of deep learning-based reconstruction combined with segmented contrast injection in \u201cone-stop\u201d cardio-cerebrovascular computed tomography angiography","volume":"15","author":"Zhang","year":"2025","journal-title":"Quant Imaging Med Surg"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"ICRP Publication 135: diagnostic reference levels in medical imaging","volume":"46","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann ICRP"},{"key":"B21","doi-asserted-by":"publisher","first-page":"205","DOI":"10.4274\/dir.2023.232265","article-title":"Establishment of local diagnostic reference levels for computed tomography with cloud-based automated dose-tracking software in t\u00fcrkiye","volume":"30","author":"Kahraman","year":"2024","journal-title":"Diagn Interv Radiol"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1963","DOI":"10.1007\/s00330-016-4547-4","article-title":"CT Imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease","volume":"27","author":"Matsumoto","year":"2017","journal-title":"Eur Radiol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"111792","DOI":"10.1016\/j.ejrad.2024.111792","article-title":"CT Imaging using variable helical pitch scanning for lower extremity arterial disease: reduced contrast medium dose, improved image quality and diagnostic accuracy","volume":"181","author":"Li","year":"2024","journal-title":"Eur J Radiol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"101576","DOI":"10.1016\/j.jmir.2024.101576","article-title":"Application and value of vHP technology in \u201cone-stop\u201d CTA scanning of carotid and coronary arteries","volume":"55","author":"Xing","year":"2024","journal-title":"J Med Imaging Radiat Sci"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1935","DOI":"10.1007\/s10554-019-01640-7","article-title":"Protocol using wide-detector CT with single contrast injection for the aorta and coronary artery: variable helical pitch versus volume scan following helical scan","volume":"35","author":"Shin","year":"2019","journal-title":"Int J Cardiovasc Imaging"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1898","DOI":"10.21037\/qims-24-824","article-title":"Comparison of \u201cone-stop\u201d coronary and head-and-neck computed tomography angiography with different scan sequences using a wide-detector system: heart-to-cranial vs. Cranial-to-heart","volume":"15","author":"Zhao","year":"2025","journal-title":"Quant Imaging Med Surg"},{"key":"B27","doi-asserted-by":"publisher","first-page":"100637","DOI":"10.1016\/j.ejro.2025.100637","article-title":"Low KV-low contrast medium dose one-stop dual source CT high pitch integrated coronary-carotid-cerebral-aortic CTA improves image quality and reduces both radiation and contrast medium doses","volume":"14","author":"Wang","year":"2025","journal-title":"Eur J Radiol Open"},{"key":"B28","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1016\/j.ejrad.2014.11.009","article-title":"Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries","volume":"84","author":"Sun","year":"2015","journal-title":"Eur J Radiol"},{"key":"B29","doi-asserted-by":"publisher","first-page":"616964","DOI":"10.3389\/fneur.2022.616964","article-title":"Free-Breathing, non-gated heart-to-brain CTA in acute ischemic stroke: a feasibility study on dual-source CT","volume":"13","author":"Liu","year":"2022","journal-title":"Front Neurol"}],"container-title":["Frontiers in Radiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fradi.2026.1887780\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T10:18:07Z","timestamp":1788257887000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fradi.2026.1887780\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":29,"alternative-id":["10.3389\/fradi.2026.1887780"],"URL":"https:\/\/doi.org\/10.3389\/fradi.2026.1887780","relation":{},"ISSN":["2673-8740"],"issn-type":[{"value":"2673-8740","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,1]]},"article-number":"1887780"}}