{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T05:09:56Z","timestamp":1788930596381,"version":"build-2803163510"},"reference-count":17,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Robot. AI"],"abstract":"<jats:p>This work presents a laboratory-scale track-based robotic colonoscope incorporating a force-differential steering mechanism. A syringe-driven hydraulic system selectively retracts individual tracks to generate asymmetric track-wall contact forces for steering. A theoretical model was developed to describe the relationships between hydraulic input, normal-force modulation, and steering torque and to provide a first-order framework for the mechanism. The prototype, was tested with force sensing and an IMU, was evaluated for straight propulsion and steering in single- and multi-bend flexible pipes. Hydraulic actuation tests showed a near-linear increase in track-wall normal force with increasing syringe input, although the measured force was substantially lower than the theoretical prediction. Steering experiments showed that motion without active steering produced approximately 35\u00b0 of yaw before traction loss, whereas force-differential steering increased the yaw angle to approximately 45\u00b0 and enabled negotiation of a 120\u00b0 bend. Tests under different friction conditions further showed that reduced wall friction impaired steering performance. In a continuous S-shaped pipe, two of three independent trials successfully completed both bends, while one trial exhibited incomplete yaw recovery, indicating trial-to-trial variability and sensitivity to traction conditions. Overall, these results provide proof-of-concept evidence for force-differential steering in a tracked robotic colonoscope and demonstrate that straight propulsion and active planar steering can be achieved within a common tracked locomotion architecture. Further miniaturisation, improved hydraulic control, and evaluation in more physiologically representative environments are required before clinical applicability can be assessed.<\/jats:p>","DOI":"10.3389\/frobt.2026.1904532","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T04:40:40Z","timestamp":1788928840000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Force-differential steering of a track-based robotic colonoscope: experimental evaluation in single and multi-bend pipes"],"prefix":"10.3389","volume":"13","author":[{"given":"Jiayang","family":"Du","sequence":"first","affiliation":[{"name":"School of Electrical and Electronic Engineering, The University of Sheffield","place":["Sheffield, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Cao","sequence":"additional","affiliation":[{"name":"School of Electrical and Electronic Engineering, The University of Sheffield","place":["Sheffield, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanja","family":"Dogramazi","sequence":"additional","affiliation":[{"name":"School of Electrical and Electronic Engineering, The University of Sheffield","place":["Sheffield, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.medengphy.2015.11.018","article-title":"Quantitative assessment of colorectal morphology: implications for robotic colonoscopy","volume":"38","author":"Alazmani","year":"2016","journal-title":"Med. Engineering & Physics"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1109\/tro.2015.2489500","article-title":"Continuum robots for medical applications: a survey","volume":"31","author":"Burgner-Kahrs","year":"2015","journal-title":"IEEE Transactions Robotics"},{"key":"B3","doi-asserted-by":"publisher","first-page":"635","DOI":"10.3390\/mi13040635","article-title":"A novel inchworm-inspired soft robotic colonoscope based on a rubber bellows","volume":"13","author":"Chen","year":"2022","journal-title":"Micromachines"},{"key":"B4","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1080\/03091902.2016.1275853","article-title":"Design and preliminary evaluation of a self-steering, pneumatically driven colonoscopy robot","volume":"41","author":"Dehghani","year":"2017","journal-title":"J. Medical Engineering & Technology"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.48550\/arXiv.2409.09557","article-title":"Adaptable, shape-conforming robotic endoscope","author":"Du","year":"2024","journal-title":"arXiv Preprint arXiv:2409.09557"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1580692","DOI":"10.3389\/frobt.2025.1580692","article-title":"Design and preliminary evaluation of a track-based robotic colonoscope with a shape-adaptable tip for propulsion","volume":"12","author":"Du","year":"2025","journal-title":"Front. Robotics AI"},{"key":"B7","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/j.dld.2009.04.022","article-title":"Colon anatomy based on CT colonography and fluoroscopy: impact on looping, straightening and ancillary manoeuvres in colonoscopy","volume":"42","author":"Eickhoff","year":"2010","journal-title":"Dig. Liver Dis."},{"key":"B8","doi-asserted-by":"publisher","first-page":"745","DOI":"10.18178\/ijmerr.11.10.745-754","article-title":"A review on wheeled type in-pipe inspection robot","volume":"11","author":"Elankavi","year":"2022","journal-title":"Int. Journal Mechanical Engineering Robotics Research"},{"key":"B9","doi-asserted-by":"crossref","first-page":"2954","DOI":"10.1109\/ICRA55743.2025.11128805","article-title":"Robotic colonoscopy: can high fidelity simulation optimize robot design and validation?","volume-title":"2025 IEEE International Conference on Robotics and Automation (ICRA)","author":"Evans","year":"2025"},{"key":"B10","doi-asserted-by":"publisher","first-page":"6870","DOI":"10.1109\/TMECH.2025.3535876","article-title":"InchIGRAB: an inchworm-inspired guided retraction and bending device for Vine robots during colonoscopy","author":"Giri","year":"2025","journal-title":"IEEE\/ASME Trans. Mechatronics"},{"key":"B11","doi-asserted-by":"publisher","first-page":"103785","DOI":"10.1016\/j.robot.2021.103785","article-title":"Review of snake robots in constrained environments","volume":"141","author":"Liu","year":"2021","journal-title":"Robotics Aut. Syst."},{"key":"B12","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1163\/1568553054255646","article-title":"Development of a steerable, wheel-type, in-pipe robot and its path planning","volume":"19","author":"Oya","year":"2005","journal-title":"Adv. Robot."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/tro.2004.838000","article-title":"Differential-drive in-pipe robot for moving inside urban gas pipelines","volume":"21","author":"Roh","year":"2005","journal-title":"IEEE Transactions Robotics"},{"key":"B14","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1111\/apt.17900","article-title":"Physiology of lower gastrointestinal tract","volume":"60","author":"Santucci","year":"2024","journal-title":"Alimentary Pharmacol. & Ther."},{"key":"B15","doi-asserted-by":"publisher","first-page":"2485","DOI":"10.3390\/cancers12092485","article-title":"Robotic-assisted colonoscopy platform with a magnetically-actuated soft-tethered capsule","volume":"12","author":"Verra","year":"2020","journal-title":"Cancers"},{"key":"B16","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1053\/j.gastro.2005.12.018","article-title":"The aer-o-scope: proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope","volume":"130","author":"Vucelic","year":"2006","journal-title":"Gastroenterology"},{"key":"B17","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1109\/tro.2008.915418","article-title":"A wireless robotic endoscope for gastrointestine","volume":"24","author":"Wang","year":"2008","journal-title":"IEEE Trans. Robotics"}],"container-title":["Frontiers in Robotics and AI"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frobt.2026.1904532\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T04:40:49Z","timestamp":1788928849000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frobt.2026.1904532\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,9]]},"references-count":17,"alternative-id":["10.3389\/frobt.2026.1904532"],"URL":"https:\/\/doi.org\/10.3389\/frobt.2026.1904532","relation":{},"ISSN":["2296-9144"],"issn-type":[{"value":"2296-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,9]]},"article-number":"1904532"}}