{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T20:13:09Z","timestamp":1775851989874,"version":"3.50.1"},"reference-count":24,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Oral Health"],"abstract":"<jats:p>Intraoral scanners generate accurate optical impressions for dentate areas, but wide edentulous spans remain challenging due to limited stable landmarks and mobile mucosa. This article describes a single-visit, chairside workflow that combines an intraoral scan with a digitized irreversible hydrocolloid impression to obtain an optimized three-dimensional model of a partially edentulous mandible suitable for computer aided design-based removable partial denture fabrication other prosthetically driven procedures. The workflow includes intraoral scanning, conventional alginate impression taking followed by chairside digitization with the same scanner, mesh trimming and inversion to generate a positive mucosal surface, and integration of both datasets through sectioned areas and targeted best-fit alignment. The resulting composite model preserves the dentate part from the impression scan. The composite model accuracy should be validated intraorally a three-dimensional printed try-in. This fully chairside protocol provides a practical approach to producing a working mandibular model for digital prosthodontic applications for patients who require a minimal clinical appointment.<\/jats:p>","DOI":"10.3389\/froh.2025.1712600","type":"journal-article","created":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T06:37:44Z","timestamp":1767595064000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Chairside digital workflow to obtain an optimized 3D model of a partially edentulous mandible"],"prefix":"10.3389","volume":"6","author":[{"given":"Alexandru E.","family":"Petre","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergiu","family":"Drafta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrei","family":"Macris","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,1,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1111\/jopr.12218","article-title":"Intraoral digital impression technique: a review","volume":"24","author":"Ting-Shu","year":"2015","journal-title":"J Prosthodont"},{"key":"B2","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.jdent.2017.12.006","article-title":"Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: a novel in vivo analysis method","volume":"69","author":"Nedelcu","year":"2018","journal-title":"J Dent"},{"key":"B3","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.prosdent.2015.09.011","article-title":"In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions","volume":"115","author":"Ender","year":"2016","journal-title":"J Prosthet Dent"},{"key":"B4","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/s12903-019-0733-5","article-title":"Intraoral scanning to fabricate complete dentures with functional borders: a proof-of-concept case report","volume":"19","author":"Unkovskiy","year":"2019","journal-title":"BMC Oral Health"},{"key":"B5","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.jpor.2017.05.005","article-title":"Development of complete dentures based on digital intraoral impressions-case report","volume":"62","author":"Fang","year":"2018","journal-title":"J Prosthodont Res"},{"key":"B6","doi-asserted-by":"publisher","first-page":"377","DOI":"10.11607\/ijp.5741","article-title":"Using intraoral scanning to capture complete denture impressions, tooth positions, and centric relation records","volume":"31","author":"Goodacre","year":"2018","journal-title":"Int J Prosthodont"},{"key":"B7","doi-asserted-by":"publisher","first-page":"166","DOI":"10.11607\/ijp.5624","article-title":"Using intraoral scanning to fabricate complete dentures: first experiences","volume":"31","author":"Goodacre","year":"2018","journal-title":"Int J Prosthodont"},{"key":"B8","doi-asserted-by":"publisher","first-page":"316","DOI":"10.4047\/jap.2021.13.5.316","article-title":"Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans","volume":"13","author":"Kontis","year":"2021","journal-title":"J Adv Prosthodont"},{"key":"B9","doi-asserted-by":"publisher","first-page":"914","DOI":"10.14219\/jada.archive.2013.0209","article-title":"Assessing the feasibility and accuracy of digitizing edentulous jaws","volume":"144","author":"Patzelt","year":"2013","journal-title":"J Am Dent Assoc"},{"key":"B10","doi-asserted-by":"publisher","first-page":"104636","DOI":"10.1016\/j.jdent.2023.104636","article-title":"Evaluation of the accuracy of intraoral scanners for complete-arch scanning: a systematic review and network meta-analysis","volume":"137","author":"Vitai","year":"2023","journal-title":"J Dent"},{"key":"B11","doi-asserted-by":"publisher","first-page":"71","DOI":"10.3390\/jcm14010071","article-title":"Accuracy of full-arch intraoral scans versus conventional impression: a systematic review with a meta-analysis and a proposal to standardise the analysis of the accuracy","volume":"14","author":"Pesce","year":"2024","journal-title":"J Clin Med"},{"key":"B12","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.prosdent.2023.09.029","article-title":"Assessment of distortion of intraoral scans of edentulous mandibular arch made with a 2-step scanning strategy: a clinical study","volume":"134","author":"Lo Russo","year":"2025","journal-title":"J Prosthet Dent"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1016\/j.prosdent.2023.01.027","article-title":"Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: an in vitro study","volume":"131","author":"Jamjoom","year":"2024","journal-title":"J Prosthet Dent"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2024.105310","article-title":"Influence of scanning pattern on accuracy, time, and number of photograms of complete-arch implant scans: a clinical study","author":"G\u00f3mez-Polo","year":"2024","journal-title":"J Dent"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/jopr.13891","article-title":"In vitro evaluation of the impact of intraoral scanner, scanning aids, and the scanned arch on the scan accuracy of edentulous arches","author":"Jamjoom","year":"2024","journal-title":"J Prosthodont"},{"key":"B16","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1016\/j.prosdent.2022.08.011","article-title":"Influence of artificial landmarks on the accuracy of complete arch scans in the partially edentulous maxilla: an in vitro study","volume":"132","author":"Waldecker","year":"2024","journal-title":"J Prosthet Dent"},{"key":"B17","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.prosdent.2022.11.024","article-title":"Integration of an intraoral scan and a conventional impression for fabricating complete dentures for a patient with flabby tissues","volume":"132","author":"Park","year":"2024","journal-title":"J Prosthet Dent"},{"key":"B18","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1111\/jopr.13060","article-title":"Combining conventional impressions and intraoral scans: a technique for the treatment of complete denture patients with flabby tissue","volume":"28","author":"Hong","year":"2019","journal-title":"J Prosthodont"},{"key":"B19","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.prosdent.2020.09.038","article-title":"Accuracy of impression-making methods in edentulous arches: an in vitro study encompassing conventional and digital methods","volume":"128","author":"Li","year":"2022","journal-title":"J Prosthet Dent"},{"key":"B20","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.prosdent.2015.04.019","article-title":"Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners","volume":"114","author":"Jeon","year":"2015","journal-title":"J Prosthet Dent"},{"key":"B21","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.prosdent.2018.10.013","article-title":"Evaluation of removable partial denture frameworks fabricated using 3 different techniques","volume":"122","author":"Tregerman","year":"2019","journal-title":"J Prosthet Dent"},{"key":"B22","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1007\/s00784-025-06336-y","article-title":"Fit accuracy assessment of removable partial denture frameworks produced by direct metal laser sintering\u2014a clinical trial","volume":"29","author":"Concei\u00e7\u00e3o","year":"2025","journal-title":"Clin Oral Investig"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1186\/s12903-024-05262-x","article-title":"Evaluation of the methods for determining accuracy of fit and precision of RPD framework in digital (3D printed, milled) and conventional RPDs - a systematic review","volume":"24","author":"Chaturvedi","year":"2024","journal-title":"BMC Oral Health"},{"key":"B24","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1111\/jopr.13786","article-title":"Patient reported outcomes and framework fit accuracy of removable partial dentures fabricated using digital techniques: a systematic review and meta-analysis","volume":"33","author":"Almufleh","year":"2024","journal-title":"J Prosthodont"}],"container-title":["Frontiers in Oral Health"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/froh.2025.1712600\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T06:37:45Z","timestamp":1767595065000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/froh.2025.1712600\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,5]]},"references-count":24,"alternative-id":["10.3389\/froh.2025.1712600"],"URL":"https:\/\/doi.org\/10.3389\/froh.2025.1712600","relation":{},"ISSN":["2673-4842"],"issn-type":[{"value":"2673-4842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,5]]},"article-number":"1712600"}}