{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T07:09:54Z","timestamp":1771571394117,"version":"3.50.1"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T00:00:00Z","timestamp":1771545600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005847","name":"Health and Medical Research Fund","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005847","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Oral Health"],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>During autologous osteocutaneous free flap transfer, the traditional process of manually contouring harvested bone segments to match the virtually planned jaw morphology is often imprecise and time-consuming. Consequently, the use of virtual surgical planning (VSP) and patient-specific surgical plates (PSPs) has gained substantial popularity in overcoming such challenges. However, the high costs and complex equipment required for manufacturing PSPs may render this technology inaccessible.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      <jats:sans-serif>This study aimed to investigate the feasibility of developing a resin-made temporary patient-specific plate (TPSP) as an adjunct to improve the surgical efficiency and accuracy of reconstructive surgeries.<\/jats:sans-serif>\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design, setting, and sample<\/jats:title>\n                    <jats:p>A prospective, single-centre study was performed. Patients indicated for computer-assisted free osteocutaneous flap reconstruction were recruited between December 2020 and October 2021.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcome variables<\/jats:title>\n                    <jats:p>Patient demographics, intraoperative characteristics, and postoperative outcomes were reviewed. Reconstruction accuracy was evaluated by comparing preoperative plans and postoperative models; the deviations and angulations of the reconstructed jaw, bone segments, and dental implants were measured.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Analyses<\/jats:title>\n                    <jats:p>\n                      <jats:sans-serif>Descriptive analysis was carried out.<\/jats:sans-serif>\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Ten patients (seven men, three women) with a mean age of 52.9\u2009\u00b1\u200918.8 years were included in the study. In terms of surgical efficiency, the mean operative time was 492\u2009\u00b1\u200984.2\u2005min, while the mean plating and reconstructive times were 58.7\u2009\u00b1\u200919.4 and 131.7\u2009\u00b1\u200926.4\u2005min, respectively. A total of 26 simultaneous dental implants were placed in eight patients. One (3.8%) implant was abandoned due to intra-operative fenestration of the fibula bone, and one implant was explanted 12 months postoperatively. In terms of accuracy, the mean absolute distance deviation was 0.621\u2009\u00b1\u20090.548 (range: 0.0047\u20131.6277). The mean distance and deviation of the reconstructed segments were 5.16\u2009\u00b1\u20092.25\u2005mm and 9.67\u00b0\u2009\u00b1\u20096.84\u00b0, respectively. The mean distance deviations at the implant platform and apex were 3.94\u2009\u00b1\u20092.20 and 3.95\u2009\u00b1\u20092.97\u2005mm, respectively, with a mean implant deviation of 12.8\u00b0\u2009\u00b1\u20099.94\u00b0.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and relevance<\/jats:title>\n                    <jats:p>\n                      <jats:sans-serif>The use of TPSP proved to be a more affordable intraoperative alternative to PSP for aligning and stabilizing bony segments during flap inset while achieving surgical efficiency and accuracy comparable to those of PSP.<\/jats:sans-serif>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/froh.2026.1692401","type":"journal-article","created":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T06:42:21Z","timestamp":1771569741000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Application of temporary patient-specific plate in head and neck osteocutaneous free flap reconstruction: a prospective pilot study"],"prefix":"10.3389","volume":"7","author":[{"given":"Yui Yin","family":"Ko","sequence":"first","affiliation":[{"name":"Division of Oral and Maxillofacial Surgery, The University of Hong Kong","place":["Sai Ying Pun, Hong Kong SAR, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu-xiong","family":"Su","sequence":"additional","affiliation":[{"name":"Division of Oral and Maxillofacial Surgery, The University of Hong Kong","place":["Sai Ying Pun, Hong Kong SAR, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingya Jane","family":"Pu","sequence":"additional","affiliation":[{"name":"Division of Oral and Maxillofacial Surgery, The University of Hong Kong","place":["Sai Ying Pun, Hong Kong SAR, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,2,20]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1016\/j.otc.2023.04.002","article-title":"Oral cavity reconstruction","volume":"56","author":"Quadri","year":"2023","journal-title":"Otolaryngol Clin North Am"},{"key":"B2","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/j.coms.2019.07.011","article-title":"Virtual surgical planning in oral and maxillofacial surgery","volume":"31","author":"Hua","year":"2019","journal-title":"Oral Maxillofac Surg Clin North Am"},{"key":"B3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1097\/01.GOX.0000842548.12853.1d","article-title":"55. Virtual surgical planning flattens the learning curve for free fibula flaps: a comparative analysis between junior and senior attendings in 561 cases","volume":"10","author":"Smith","year":"2022","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"B4","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.joms.2014.07.038","article-title":"Are virtual planning and guided surgery for head and neck reconstruction economically viable?","volume":"73","author":"Zweifel","year":"2015","journal-title":"J Oral Maxillofac Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1016\/j.acra.2019.08.011","article-title":"Medical 3D printing cost-savings in orthopedic and maxillofacial surgery: cost analysis of operating room time saved with 3D printed anatomic models and surgical guides","volume":"27","author":"Ballard","year":"2020","journal-title":"Acad Radiol"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1016\/j.joms.2025.05.008","article-title":"Patient-specific titanium implants reduce hardware-related complications compared to stock reconstruction plates for virtually guided fibular free aps in head and neck reconstruction","volume":"83","author":"Mohamed","year":"2025","journal-title":"J Oral Maxillofac Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1322","DOI":"10.1002\/hed.27759","article-title":"Evaluating the benefit of virtual surgical planning on bony union rates in head and neck reconstructive surgery","volume":"46","author":"Sabiq","year":"2024","journal-title":"Head Neck"},{"key":"B8","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1515\/iss-2021-0045\/html","article-title":"Virtual planning for mandible resection and reconstruction","volume":"8","author":"Probst","year":"2023","journal-title":"Innov Surg Sci"},{"key":"B9","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.jot.2023.08.004","article-title":"3D printing metal implants in orthopedic surgery: methods, applications and future prospects","volume":"42","author":"Meng","year":"2023","journal-title":"J Orthop Translat"},{"key":"B10","volume-title":"PA 2200: Material Data Sheet","author":"ReportGmbH","year":"2025"},{"key":"B11","doi-asserted-by":"publisher","first-page":"746952","DOI":"10.3389\/fonc.2022.746952","article-title":"Unexpected change of surgical plans and contingency strategies in computer-assisted free flap jaw reconstruction: lessons learned from 98 consecutive cases","volume":"12","author":"Pu","year":"2022","journal-title":"Front Oncol"},{"key":"B12","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1245\/s10434-020-08732-y","article-title":"Three-dimensionally printed patient specific surgical plates increase accuracy of oncologic head and neck reconstruction versus conventional surgical plates: a comparative study","volume":"28","author":"Yang","year":"2021","journal-title":"Ann Surg Oncol"},{"key":"B13","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.ijom.2019.05.005","article-title":"A novel \u2019surgeon-dominated\u2019 approach to the design of 3D-printed patient-specific surgical plates in mandibular reconstruction: a proof-of-concept study","volume":"49","author":"Yang","year":"2020","journal-title":"Int J Oral Maxillofac Surg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"743389","DOI":"10.3389\/fonc.2021.743389","article-title":"A comparative study on a novel fibula malleolus cap to increase the accuracy of oncologic jaw reconstruction","volume":"11","author":"Pu","year":"2021","journal-title":"Front Oncol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1016\/j.bjoms.2020.08.088","article-title":"Printed titanium implants in UK craniomaxillofacial surgery. Part II: perceived performance (outcomes, logistics, and costs)","volume":"59","author":"Goodson","year":"2021","journal-title":"Br J Oral Maxillofac Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.joms.2020.07.216","article-title":"An in-house computer-aided design and computer-aided manufacturing workow for maxillofacial free ap reconstruction is associated with a low cost and high accuracy","volume":"79","author":"Moe","year":"2021","journal-title":"J Oral Maxillofac Surg"},{"key":"B17","doi-asserted-by":"publisher","first-page":"737769","DOI":"10.3389\/fonc.2021.737769","article-title":"The learning curve of computer-assisted free flap jaw reconstruction surgery using 3D-printed patient-specific plates: a cumulative sum analysis","volume":"11","author":"Zhu","year":"2021","journal-title":"Front Oncol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1097\/PRS.0000000000007077","article-title":"Dental implant survival in vascularized bone flaps: a systematic review and meta-analysis","volume":"146","author":"Panchal","year":"2020","journal-title":"Plast Reconstr Surg"},{"key":"B19","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.jcms.2015.03.015","article-title":"Accuracy of fibula reconstruction using patient-specific CAD\/CAM reconstruction plates and dental implants: a new modality for functional reconstruction of mandibular defects","volume":"43","author":"Schepers","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"key":"B20","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.oraloncology.2019.07.022","article-title":"Accuracy of computer-assisted mandibular reconstructions with free fibula ap: results of a single-center series","volume":"97","author":"Goormans","year":"2019","journal-title":"Oral Oncol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/s10006-005-0656-y","article-title":"Computer assisted chewing power in patients with segmental resection of the mandible","volume":"10","author":"Maurer","year":"2006","journal-title":"Mund Kiefer Gesichtschir"},{"key":"B22","doi-asserted-by":"publisher","first-page":"109843","DOI":"10.1016\/j.compbiomed.2025.109843","article-title":"Biomechanical assessment in virtual surgical planning for mandibular reconstruction","volume":"189","author":"Wan","year":"2025","journal-title":"Comput Biol Med"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1016\/j.ijom.2025.04.1141","article-title":"Fibula free ap reconstruction: improving the accuracy of virtual surgical planning using titanium inserts","volume":"54","author":"Coppen","year":"2025","journal-title":"Int J Oral Maxillofac Surg"},{"key":"B24","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1016\/j.joms.2018.12.025","article-title":"Precision of simultaneous guided dental implantation in microvascular fibular flap reconstructions with and without additional guiding splints","volume":"77","author":"Zweifel","year":"2019","journal-title":"J Oral Maxillofac Surg"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1645","DOI":"10.1016\/j.jcms.2018.05.047","article-title":"Three-dimensional accuracy of mandibular reconstruction by patient-specific pre-bent reconstruction plates using an \u201cin-house\u201d 3D-printer","volume":"46","author":"Naros","year":"2018","journal-title":"J Craniomaxillofac Surg"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1604","DOI":"10.1016\/j.jds.2023.02.006","article-title":"Application of digital guide plate with drill-hole sharing technique in the mandible reconstruction","volume":"18","author":"Wang","year":"2023","journal-title":"J Dent Sci"},{"key":"B27","doi-asserted-by":"publisher","first-page":"2211","DOI":"10.1016\/j.joms.2018.04.028","article-title":"Novel patient-specific 3-dimensional printed fixation tray for mandibular reconstruction with fibular free flaps","volume":"76","author":"Arce","year":"2018","journal-title":"J Oral Maxillofac Surg"},{"key":"B28","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.oraloncology.2017.11.011","article-title":"Utilization of a pre-bent plate-positioning surgical guide system in precise mandibular reconstruction with a free fibula ap","volume":"75","author":"Bao","year":"2017","journal-title":"Oral Oncol"}],"container-title":["Frontiers in Oral Health"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/froh.2026.1692401\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T06:42:21Z","timestamp":1771569741000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/froh.2026.1692401\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,20]]},"references-count":28,"alternative-id":["10.3389\/froh.2026.1692401"],"URL":"https:\/\/doi.org\/10.3389\/froh.2026.1692401","relation":{},"ISSN":["2673-4842"],"issn-type":[{"value":"2673-4842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,20]]},"article-number":"1692401"}}